Full‐arch prostheses supported by implants with different macrostructures: A multicenter randomized controlled trial
Authors:
- Ana Carolina Monachini MarcantonioAMAna Carolina Monachini Marcantonio
- Guilherme José Pimentel Lopes de OliveiraGOGuilherme José Pimentel Lopes de Oliveira
- Paulo Afonso TassiPTPaulo Afonso Tassi
- João Paulo Lavagnoli ManfrinatoJMJoão Paulo Lavagnoli Manfrinato
- Bruno SegniniBSBruno Segnini
- Raphael Ferreira de Souza Bezerra AraújoRARaphael Ferreira de Souza Bezerra Araújo
- Larissa Carvalho TrojanLTLarissa Carvalho Trojan
- Flávia Noemy Gasparini Kiatake FontãoFFFlávia Noemy Gasparini Kiatake Fontão
- Ivete Aparecida de Mattias SartoriISIvete Aparecida de Mattias Sartori
- Elisa Mattias SartoriESElisa Mattias Sartori
- Luis Eduardo Marques PadovanLPLuis Eduardo Marques Padovan
- Daniela Leal Zandim‐BarcelosDZDaniela Leal Zandim‐Barcelos
- 3 October 2024
- journal article
- research article
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 27 (1)
Abstract
Objectives: This study evaluates the clinical performance of implants with hydrophilic surface and two different macrostructures: cylindrical with perforating triangular threads (CT) and cylindrical‐tapered with the association of square and condensing and perforating triangular threads (TST).Materials and methods: This was a multicenter split‐mouth, simple‐blinded, randomized, and controlled trial. Thirty patients with edentulous mandible received two CT and two TST implants. Primary stability was determined by insertion torque and resonance frequency analysis (RFA). Implants were loaded with full fixed‐arch prostheses within 24 h after insertion. Clinical parameters (visible plaque index, marginal bleeding index; bleeding on probing; probing depth; and clinical attachment level) and the RFA were assessed at 2, 6, 12, and 24 months after implant loading. Marginal bone level changes were measured by comparison of standardized radiographs taken on the day of implant placement and 6, 12, and 24 months thereafter.Results: Twenty‐eight patients completed the 2‐year follow‐up. The survival rates were 99.16% for CT implants and 100% for TST implants. One CT implant was lost until the 2 months follow‐up. No significant differences were found between the two implant types for marginal bone level changes (CT 0.34 [0.24; 0.55 mm]; 0.33 [0.18; 0.55 mm]; 0.41 [0.12; 0.7 mm] vs TST 0.36 [0.14; 0.74 mm]; 0.33 [0.23; 0.63 mm]; 0.30 [0.20; 0.64 mm] at 6, 12, and 24 months, respectively) and other clinical parameters.Conclusion: The macrostructure of the implants had no influence on survival rate, primary and secondary stability, marginal bone level changes, and peri‐implant clinical parameters outcomes. Both implants can be predictably used for immediate loading of full‐arch mandibular prostheses.Keywords
This publication has 30 references indexed in Scilit:
- The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysisJournal of Dental Sciences, 2020
- Hydrophilic modification of sandblasted and acid-etched implants improves stability during early healing: a human double-blind randomized controlled trialInternational Journal of Oral and Maxillofacial Surgery, 2019
- Resonance Frequency Analysis of Dental Implants With 2 Types of Surface Treatment Submitted to Immediate LoadingImplant Dentistry, 2018
- A randomized controlled clinical trial to assess crestal bone remodeling of four different implant designsClinical Implant Dentistry and Related Research, 2018
- Influence of thread shape and inclination on the biomechanical behaviour of plateau implant systemsDental Materials, 2018
- Comparison between tapered and cylindrical implants in the posterior regions of the mandible: A prospective, randomized, split‐mouth clinical trial focusing on implant stability changes during early healingClinical Implant Dentistry and Related Research, 2017
- Primary Stability of Cylindrical and Conical Dental Implants in Relation to Insertion Torque—A Comparative Ex Vivo EvaluationImplant Dentistry, 2017
- Effects of Surface Treatment Modification and Implant Design in Implants Placed Crestal and Subcrestally Applying Delayed Loading ProtocolJournal of Craniofacial Surgery, 2017
- Peri-implant bone loss around platform-switched Morse taper connection implants: a prospective 60-month follow-up studyInternational Journal of Oral and Maxillofacial Surgery, 2016
- Bone Remodeling Around Implants with External Hexagon and Morse‐Taper Connections: A Randomized, Controlled, Split‐Mouth, Clinical TrialClinical Implant Dentistry and Related Research, 2016