VDVaishnavi Dhawan

Vaishnavi Dhawan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Vaishnavi Dhawan has a total of 17 co-authors. Here are the top co-authors by number of shared publications:

  • Xinyan Tracy Cui

    University of Pittsburgh

    7 shared publications
  • Delin Shi

    University of Pittsburgh, Department of Bioengineering, 4200 Fifth Avenue, Pittsburgh, PA, 15260, USA; Center for the Neural Basis of Cognition, 4400 Fifth Avenue, Suite 115, Pittsburgh, PA, 15213, USA

    2 shared publications
  • Delin Shi

    Department of Bioengineering, University of Pittsburgh, Pittsburgh, USA

    2 shared publications
  • Kevin Woeppel

    University of Pittsburgh, Department of Bioengineering, 4200 Fifth Avenue, Pittsburgh, PA, 15260, USA; Center for the Neural Basis of Cognition, 4400 Fifth Avenue, Suite 115, Pittsburgh, PA, 15213, USA

    2 shared publications
  • Sharada Narayanan

    Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States; Center for Neural Basis of Cognition, Pittsburgh, PA, United States

    2 shared publications
  • Abdul Hoque

    Department of Chemistry, University of Cincinnati, Cincinnati, Ohio 45221, United States

    1 shared publication

Latest Publications

  • Open Access

    Impact of ClockΔ19 Mutation on Neural Recording Performance and Neural Inflammatory Responses

    by Vaishnavi Dhawan, Sharada Narayanan, Cort H. Thompson, Delin Shi, Yugma Patel, Colleen A. McClung, Xinyan T. Cui

    Chronically implanted neural electrodes for neural recording, stimulation, and chemical sensing are essential tools in studying and treating neurological disorders. However, their performances are limited by implant-induced inflammation, causing a loss in signal quality over time. Because disease states can alter inflammatory processes, it is critical to characterize tissue response to neural implants within relevant disease models. Circadian rhythm disruption is a hallmark of many psychiatric and neurodegenerative disorders, yet its influence on neural implant performance remains poorly understood. The Circadian Locomotor Output Cycles Kaput (Clock) gene is a core regulator of circadian rhythms and a key modulator of inflammatory pathways, including NF-κB signaling. ClockΔ19 mutant mouse is a well-established model of circadian disruption with documented immunological abnormalities. Here, we evaluated striatal electrophysiological recording performance and quantified the host tissue response to microelectrode implants in ClockΔ19 (MU) and wild-type (WT) mice over four weeks. Silicon microelectrode arrays (MEAs) were implanted into the striatum, followed by weekly electrochemical impedance spectroscopy and neuronal recording measurements. Electrodes implanted in MU mice exhibited significantly lower impedance, noise, and peak-to-peak amplitude compared to WT mice, while signal-to-noise ratio and channel yield were comparable between groups. Endpoint immunohistological analyses revealed significantly reduced microglia and astrocyte activity, as indicated by lower Iba-1 and GFAP intensities around the implant site in MU mice. Additionally, ClockΔ19 tissue showed elevated 4- hydroxynonenal(HNE) levels and reduced nuclear NF-κB expression following implantation. Morphological analysis further identified baseline and injury-induced differences in microglia phenotypes between MU and WT animals. Notably, reduced neuronal density and neurofilament expression surrounding the implant in MU suggest compromised neuronal integrity. Together, these findings demonstrate that circadian disruption alters both neural and immune response to chronic neural implants, resulting in heightened oxidative stress and an impaired reparative inflammatory response. This work highlights the importance of circadian regulation in neuroimmune responses, providing insights into how circadian dysfunction may impact long-term neural interface performance with implications for both basic research and clinical neurotechnology development.

  • Open Access

    A comparative study assessing neural recording quality and inflammatory tissue response between stiff and flexible microelectrode arrays

    by Vaishnavi Dhawan, Bingchen Wu, Sharada Narayanan, Delin Shi, Yugma Patel, Xinyan Tracy Cui


  • Open Access

    Investigation of a chondroitin sulfate-based bioactive coating for neural interface applications

    by Vaishnavi Dhawan, Paige Nicole Martin, Xiaoming Hu, Xinyan Tracy Cui

    Invasive neural implants allow for high-resolution bidirectional communication with the nervous tissue and have demonstrated the ability to record neural activity, stimulate neurons, and sense neurochemical species with high spatial selectivity and resolution. However, upon implantation, they are exposed to a foreign body response which can disrupt the seamless integration of the device with the native tissue and lead to deterioration in device functionality for chronic implantation. Modifying the device surface by incorporating bioactive coatings has been a promising approach to camouflage the device and improve integration while maintaining device performance. In this work, we explored the novel application of a chondroitin sulfate (CS) based hydrophilic coating, with anti-fouling and neurite-growth promoting properties for neural recording electrodes. CS-coated samples exhibited significantly reduced protein-fouling in vitro which was maintained for up to 4-weeks. Cell culture studies revealed a significant increase in neurite attachment and outgrowth and a significant decrease in microglia attachment and activation for the CS group as compared to the control. After 1-week of in vivo implantation in the mouse cortex, the coated probes demonstrated significantly lower biofouling as compared to uncoated controls. Like the in vitro results, increased neuronal population (neuronal nuclei and neurofilament) and decreased microglial activation were observed. To assess the coating's effect on the recording performance of silicon microelectrodes, we implanted coated and uncoated electrodes in the mouse striatum for 1 week and performed impedance and recording measurements. We observed significantly lower impedance in the coated group, likely due to the increased wettability of the coated surface. The peak-to-peak amplitude and the noise floor levels were both lower in the CS group compared to the controls, which led to a comparable signal-to-noise ratio between the two groups. The overall single unit yield (% channels recording a single unit) was 74% for the CS and 67% for the control group on day 1. Taken together, this study demonstrates the effectiveness of the polysaccharide-based coating in reducing biofouling and improving biocompatibility for neural electrode devices.


  • Open Access

    Evaluation of Polymer-Coated Carbon Nanotube Flexible Microelectrodes for Biomedical Applications

    by Chethani Ruhunage, Vaishnavi Dhawan, Chaminda P. Nawarathne, Abdul Hoque, Xinyan Tracy Cui, Noe T. Alvarez

    The demand for electrically insulated microwires and microfibers in biomedical applications is rapidly increasing. Polymer protective coatings with high electrical resistivity, good chemical resistance, and a long shelf-life are critical to ensure continuous device operation during chronic applications. As soft and flexible electrodes can minimize mechanical mismatch between tissues and electronics, designs based on flexible conductive microfibers, such as carbon nanotube (CNT) fibers, and soft polymer insulation have been proposed. In this study, a continuous dip-coating approach was adopted to insulate meters-long CNT fibers with hydrogenated nitrile butadiene rubber (HNBR), a soft and rubbery insulating polymer. Using this method, 4.8 m long CNT fibers with diameters of 25–66 µm were continuously coated with HNBR without defects or interruptions. The coated CNT fibers were found to be uniform, pinhole free, and biocompatible. Furthermore, the HNBR coating had better high-temperature tolerance than conventional insulating materials. Microelectrodes prepared using the HNBR-coated CNT fibers exhibited stable electrochemical properties, with a specific impedance of 27.0 ± 9.4 MΩ µm2 at 1.0 kHz and a cathodal charge storage capacity of 487.6 ± 49.8 mC cm−2. Thus, the developed electrodes express characteristics that made them suitable for use in implantable medical devices for chronic in vivo applications.


  • Effects of neuronal cell adhesion molecule L1 and nanoparticle surface modification on microglia

    by Neetu Kushwah, Kevin Woeppel, Vaishnavi Dhawan, Delin Shi, Xinyan Tracy Cui


  • Carbohydrate based biomaterials for neural interface applications

    by Vaishnavi Dhawan, Xinyan Tracy Cui

    Due to their specific bioactivities and hydrophilic properties, carbohydrates offer potential solutions for addressing some of the limitations of the existing biomolecular approaches for neural interfacing applications.