Shuangshuang Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shuangshuang Li has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Shuang Jiang
Dalian Minzu University
2 shared publications - Shugang Wang
Faculty of Infrastructure Engineering, Dalian University of Technology, Dalian 116024, China
2 shared publications - He Wang
College of Civil Engineering and Architecture, Dalian University, Dalian 116622, China
1 shared publication - Hu Chen
School of Civil Engineering, Chongqing University, Chongqing 400045, China
1 shared publication - M. Hasanuzzaman
UM Power Energy Dedicated Advanced Center, Level 4, Wisma R&D University of Malaya Kuala Lumpur Malaysia
1 shared publication - Xiaozhou Wu
Dalian University of Technology
1 shared publication
Latest Publications
- Open Access
Field Measurement and Data-Driven Modeling of a Photovoltaic/Thermal and Air-Source Dual-Source Heat Pump System in Dalian, China
Dual-source heat pump systems combining photovoltaic-thermal (PVT) and air-source technologies have attracted considerable research interest due to their energy complementarity. Based on the climatic characteristics of the Dalian region, this study conducted field measurements and data analysis on a developed dual-source heat pump system incorporating three adaptive operational modes: (1) PVT mode, (2) PVT/air dual-source mode, and (3) photovoltaic (PV)/air-source mode. Compared to Mode (3), Mode (1) achieves a 5.76% higher heating capacity and an 11.56% greater electrical efficiency. Meanwhile, Mode (2) demonstrates a 12.23% increase in heating capacity, and a 9.14% improvement in electrical efficiency relative to Mode (3). A data-driven methodology is provided to quantify the system’s evaporation temperature, the thermal efficiency of PVT mode, and the coefficient of performance (COP) of the PVT heat pump. The economic assessment demonstrates that the proposed dual-source heat pump system achieves a heating cost as low as RMB 0.1125/kWh and a payback period of 6.4 years, indicating favorable economic benefits. This study provides fundamental data and computational methods for the optimized operation of the PVT/air dual-source heat pump.
Open AccessField Measurement and Data-Driven Modeling of a Photovoltaic/Thermal and Air-Source Dual-Source Heat Pump System in Dalian, China
Dual-source heat pump systems combining photovoltaic-thermal (PVT) and air-source technologies have attracted considerable research interest due to their energy complementarity. Based on the climatic characteristics of the Dalian region, this study conducted field measurements and data analysis on a developed dual-source heat pump system incorporating three adaptive operational modes: (1) PVT mode, (2) PVT/air dual-source mode, and (3) photovoltaic (PV)/air-source mode. Compared to Mode (3), Mode (1) achieves a 5.76% higher heating capacity and an 11.56% greater electrical efficiency. Meanwhile, Mode (2) demonstrates a 12.23% increase in heating capacity, and a 9.14% improvement in electrical efficiency relative to Mode (3). A data-driven methodology is provided to quantify the system’s evaporation temperature, the thermal efficiency of PVT mode, and the coefficient of performance (COP) of the PVT heat pump. The economic assessment demonstrates that the proposed dual-source heat pump system achieves a heating cost as low as RMB 0.1125/kWh and a payback period of 6.4 years, indicating favorable economic benefits. This study provides fundamental data and computational methods for the optimized operation of the PVT/air dual-source heat pump.
- Open Access
Analysis of the Air-Reversed Brayton Heat Pump with Different Layouts of Turbochargers for Space Heating
The air-reversed Brayton cycle produces charming, environmentally friendly effects by using air as its refrigerant and has potential energy efficiency in applications related to space heating and building heating. However, there exist several types of cycle that need to be discussed. In this paper, six types of air-reversed Brayton heat pump with a turbocharger, applicable under different heating conditions, are developed. The expressions of the heating coefficient of performance (COP) and the corresponding turbine pressure ratio are derived based on thermodynamic analysis. By using these expressions, the effects of turbine pressure ratio on the COP under different working conditions are theoretically analyzed, and the optimal COPs of different cycles under specific working conditions are determined. It is observed that Cycles A and C have the highest heating COPs, and there is an optimal pressure ratio for each cycle. The corresponding pressure ratio of the optimal COP is different, concentrated in the range of 1.5–1.9. When the pressure ratio reaches the optimal value, increasing the pressure ratio does not significantly improve the heating COP. Take Cycle F as an example: the maximum error between the calculated results and experimental observation is lower than 5.6%. These results will enable further study of the air-reversed Brayton heat pump with a turbocharger from a different perspective.
Open AccessAnalysis of the Air-Reversed Brayton Heat Pump with Different Layouts of Turbochargers for Space Heating
The air-reversed Brayton cycle produces charming, environmentally friendly effects by using air as its refrigerant and has potential energy efficiency in applications related to space heating and building heating. However, there exist several types of cycle that need to be discussed. In this paper, six types of air-reversed Brayton heat pump with a turbocharger, applicable under different heating conditions, are developed. The expressions of the heating coefficient of performance (COP) and the corresponding turbine pressure ratio are derived based on thermodynamic analysis. By using these expressions, the effects of turbine pressure ratio on the COP under different working conditions are theoretically analyzed, and the optimal COPs of different cycles under specific working conditions are determined. It is observed that Cycles A and C have the highest heating COPs, and there is an optimal pressure ratio for each cycle. The corresponding pressure ratio of the optimal COP is different, concentrated in the range of 1.5–1.9. When the pressure ratio reaches the optimal value, increasing the pressure ratio does not significantly improve the heating COP. Take Cycle F as an example: the maximum error between the calculated results and experimental observation is lower than 5.6%. These results will enable further study of the air-reversed Brayton heat pump with a turbocharger from a different perspective.