NLNing Li

Ning Li

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ning Li has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A study on the influence of excitation parameters and sensor configuration on the performance of ultrasonic longitudinal and transverse wave bolt preload detection

    by Qilin Jiang, Sizhu Zhou, Ning Li, Yun Zeng, Hongting Che, Yi Feng

    Accurate measurement of bolt preload is crucial for the safe service life of engineering structures. Addressing issues such as the lack of theoretical basis for parameter selection, insufficient signal stability, and limited measurement accuracy in traditional longitudinal and transverse wave bolt preload testing, this study focuses on M36 × 3-350 high-strength bolts to a force–electric–acoustic multiphysics coupling model was established to investigate the mechanisms by which key parameters—such as excitation frequency, modulation period, piezoelectric transducer material, and excitation position—influence ultrasonic propagation characteristics and testing performance, and a parameter optimization method was proposed. Based on this, a combination of experimental and simulation methods was used to compare and validate the testing performance under optimized and non-optimized parameter configurations. The study indicates that the optimal excitation frequencies for longitudinal and transverse waves are 2 MHz and 1 MHz, respectively. When using a Hanning window modulation with a period of 5, an optimal balance between ultrasonic signal energy and the accuracy of first-arrival time identification is achieved; the transducer combination of PZT-4 for excitation and PZT-5 H for reception significantly improves the signal-to-noise ratio, while axial excitation helps suppress modal transition and enhance beam directivity; Under optimized parameter conditions, the measurement error for preload was controlled within 3%, whereas under non-optimized conditions, the error could reach 8%. The experimental results were in good agreement with numerical simulations. The proposed parameter optimization strategy can significantly improve the accuracy and stability of bolt preload detection using the longitudinal and transverse wave methods, providing a theoretical basis and technical support for engineering applications.

  • A new method for detecting bolt preload based on a combination of longitudinal and transverse ultrasonic waves

    by Qilin Jiang, Sizhu Zhou, Ning Li, Ruiling Li, Yun Zeng, Yi Feng

    Accurate measurement of bolt preload is critical for ensuring the performance and operational safety of mechanical structural connections. However, traditional modal-conversion-based longitudinal and transverse wave (T-wave) testing methods suffer from low T-wave excitation efficiency, insufficient signal stability, and limited feature-extraction accuracy. Taking an M36 × 3–350 mm bolt as the research subject, this study proposes an ultrasonic testing method based on direct excitation of T-waves using the D15 shear mode of a piezoelectric transducer. It simultaneously incorporates the t T / t L time ratio feature to characterize the preload and employs a cubic spline interpolation algorithm to reconstruct the discretely sampled signals, thereby improving peak localization accuracy and enhancing the precision of time-of-flight extraction. The research results indicate: (1) Compared to traditional modal conversion excitation methods, direct excitation via the D15 shear mode significantly improves T-wave excitation efficiency and modal purity. (2) The sound time ratio between transverse and longitudinal waves exhibits a significant linear negative correlation with bolt pretension and can serve as an effective feature parameter for characterizing changes in bolt pretension; numerical simulations agree well with experimental results, with the overall measurement error controlled within 3%. (3) The use of a cubic spline interpolation algorithm enables the raw sampling interval to be increased from 0.01 – 0.0001 μ s, improving the positioning accuracy of the first-arrival time of ultrasonic waves and enabling the effective identification of minute changes in preload. These research findings provide a theoretical foundation and technical support for bolt connection condition monitoring and intelligent structural health monitoring under complex operating conditions.

  • Open Access

    Research on Bolt Loosening Detection Based on Fractional Fourier Transform and Vibro-Acoustic Modulation Method

    by Xiaogang Wang, Hai Yang, Jingjing Qi, Hao Zhang, Ning Zhao, Qilin Jiang, Ning Li

    By applying nonlinear vibration-to-sound modulation technology to bolt loosening detection, this paper proposes a new experimental setup and signal-processing method. A linear swept-frequency signal is used to excite low-frequency vibrations, while a fixed-frequency sine wave is used for high-frequency ultrasonic excitation. First, a fractional Fourier transform is applied to the vibration-acoustic modulation signal to transform it into the optimal fractional domain where the energy of the swept-frequency signal is concentrated; next, the swept-frequency signal undergoes a masking filter, and the filtered signal is transformed back to the time domain; finally, the time-domain signal is transformed back to the frequency domain, and the amplitudes of the sum and difference frequency components of the high-frequency signal are extracted as damage parameters. The effectiveness of this method in bolt loosening detection was verified through bolt connection tests, with the applied tightening torque ranging from 10 to 30 N·m. This method is simple to operate and highly robust, making it a reliable approach for detecting the degree of loosening in bolt connections.

  • Open Access

    A New Method for Calculating the Setting Stress of Downhole Packer’s Inner Sleeve

    by Zixuan Tian, Sizhu Zhou, Wanquan Deng, Ning Li, Xiang Li, Yun Zeng, Shujie Liu

    There is no analytical solution to the stress, strain and displacement changes in the inner sleeve of the downhole packer during service. In this paper, the inner sleeve structure is simplified based on the shell theory model, and the geometric equation and physical equation suitable for the inner-sleeve structure are established based on the control differential equation of the cylindrical shell derived by Flügge. Finally, the analytical solution calculation program of the radial displacement, and strain and stress value of each node of the cylindrical shell under the external load condition is compiled by using MATLAB R2024a software. The analytical solution is compared with the numerical solution of each parameter under the same conditions, and the root mean square error between the numerical solution and the analytical solution is evaluated. The results show that the analytical formulas of the stress, strain and displacement of the inner sleeve structure of the downhole packer established in this paper can accurately obtain the above parameters. The root mean square errors between the analytical formulas and the numerical solutions are 0.083, 0.074 and 0.086, indicating that the fitting degree between the two is good, which verifies the effectiveness of the theoretical model based on the shell to describe the stress state of the inner sleeve. The model also accurately reflects the partial stress and strain law of the inner sleeve of the downhole packer to a certain extent. This study provides theoretical support for the design optimization of the inner sleeve of a pipeline packer, and also provides some guidance for the study of the stress state of its inner sleeve.

  • Open Access

    A New Method for Erosion Prediction of 90° Elbow Based on Non-Axisymmetric Ultrasonic-Guided Wave and the PSO–LSSVM Algorithm

    by Zhaokun Wang, Sizhu Zhou, Ning Li, Yun Zeng, Gui Li

    The non-axisymmetric exciting guided wave can detect the thinning section of the elbow, and the time domain energy value of the signal collected at the outer arch position of the receiving end displays a downward trend as the remaining thickness of the erosion area decreases. To address the difficulty in detecting the erosion degree of the elbow with high accuracy, this paper uses the linear frequency modulation (LFM) signal to excite a non-axisymmetric guided wave that propagates in the 90° elbow and collects signals through four PZT receivers. To predict the erosion degree, the corresponding relationship between the energy value of the four signals after fractional Fourier filtering and the degree of elbow erosion is established through the particle swarm optimization (PSO)–least squares support vector machine (LSSVM) algorithm. The results show that the method proposed has an average accuracy rate of 98.1864%, 94.7167%, 99.119%, and 99.9593% for predicting the erosion degree of four elbow samples, and 94.0039%. and 81.2976% for two new erosion degrees, which are higher than the nonlinear regression model, LSSVM algorithm, and BP neural network algorithm. This study has guiding significance for real-time monitoring of elbow erosion.


  • Open Access

    Experiment and Theoretical Investigation on Fatigue Life Prediction of Fracturing Pumpheads Based on a Novel Stress-Field Intensity Approach

    by Yun Zeng, Meiqiu Li, Han Wu, Ning Li, Yang Zhou

    Fracturing pumpheads are typical pressure vessels that experience frequent fatigue failure under the effect of notches in their cross-bore. To enhance the fatigue life of fracturing pumpheads, the study of the notch effect is indispensable and important to establish a reliable mathematical model to predict their fatigue life. In the present paper, two novel fatigue life prediction models are proposed for notched specimens. In these models, two new geometric fatigue failure regions are defined to improve the weight function. Finally, the elaborated novel stress-field intensity approach was applied to three different types of notched specimens. Experiment results indicate that the new SFI approach achieves 47.82%, 39.48%, and 31.85% higher prediction accuracy than the traditional SFI approach, respectively. It was found that the modified SFI approach provided better predictions than the traditional SFI approach and the TCD method. The II-th novel SFI approach had the highest accuracy, and the I-th novel SFI approach was more suitable for sharply notched specimens.