TATarek Ayoub

Tarek Ayoub

*This is an algorithmically generated author record based on publicly available information.

Tarek Ayoub has a total of 43 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comprehensive atrial fibrillation burden and symptom reduction post-ablation: insights from DECAAF II

    by Charbel Noujaim, Ala Assaf, Chanho Lim, Han Feng, Hadi Younes, Mario Mekhael, Nour Chouman, Ghaith Shamaileh, Abdel Hadi El Hajjar, Tarek Ayoub, et al.

    Traditional atrial fibrillation (AF) recurrence after catheter ablation is reported as a binary outcome. However, a paradigm shift towards a more granular definition, considering arrhythmic or symptomatic burden, is emerging. We hypothesize that ablation reduces AF burden independently of conventional recurrence status in patients with persistent AF, correlating with symptom burden reduction. Ninety-eight patients with persistent AF from the DECAAF II trial with pre-ablation follow-up were included. Patients recorded daily single-lead electrocardiogram (ECG) strips, defining AF burden as the proportion of AF days among total submitted ECG days. The primary outcome was atrial arrhythmia recurrence. The AF severity scale was administered pre-ablation and at 12 months post-ablation. At follow-up, 69 patients had atrial arrhythmia recurrence and 29 remained in sinus rhythm. These patients were categorized into a recurrence (n = 69) and a no-recurrence group (n = 29). Both groups had similar baseline characteristics, but recurrence patients were older (P = 0.005), had a higher prevalence of hyperlipidaemia (P = 0.007), and had a larger left atrial (LA) volume (P = 0.01). There was a reduction in AF burden in the recurrence group when compared with their pre-ablation burden (65 vs. 15%, P < 0.0001). Utah Stage 4 fibrosis and diabetes predicted less improvement in AF burden. The symptom severity score at 12 months post-ablation was significantly reduced compared with the pre-ablation score in the recurrence group, and there was a significant correlation between the reduction in symptom severity score and the reduction in AF burden (R = 0.39, P = 0.001). Catheter ablation reduces AF burden, irrespective of arrhythmia recurrence post-procedure. There is a strong correlation between AF burden reduction and symptom improvement post-ablation. Notably, elevated LA fibrosis impedes AF burden decrease following catheter ablation.


  • Comparison of Ablation Strategies for Persistent Atrial Fibrillation: A Post Hoc Analysis of the DECAAF II Study

    by Charbel Noujaim, Botao Shan, Jitae A. Kim, Mario Mekhael, Han Feng, Ala Assaf, Hadi Younes, Nour Chouman, Chanho Lim, Tarek Ayyoub, et al.


  • Open Access

    Catheter ablation improved ejection fraction in persistent AF patients: a DECAAF-II sub analysis

    by Mario Mekhael, Botao Shan, Charbel Noujaim, Nour Chouman, Alaa Assaf, Hadi Younes, Abdel Hadi El Hajjar, Lilas Dagher, Han Feng, Hua He, et al.

    The aim of our study was to assess differences in post-ablation atrial fibrillation (AF) recurrence and burden and to quantify the change in LVEF across different congestive heart failure (CHF) subcategories of the DECAAF-II population. Differences in the primary outcome of AF recurrence between CHF and non-CHF groups was calculated. The same analysis was performed for the three subgroups of CHF and the non-CHF group. Differences in AF burden after the 3-month blanking period between CHF and non-CHF groups was calculated. Improvement in LVEF was calculated and compared across the three CHF groups. Improvement was also calculated across different fibrosis stages. There was no significant differences in AF recurrence and AF burden after catheter ablation between CHF and non-CHF patients and between different CHF subcategories. Patients with heart failure with reduced ejection fraction (HFrEF) experienced the greatest improvement in EF following catheter ablation (CA, 16.66% ± 11.98, P < 0.001) compared to heart failure with moderately reduced LVEF, and heart failure with preserved EF (10.74% ± 8.34 and 2.00 ± 8.34 respectively, P-value < 0.001). Moreover, improvement in LVEF was independent of the four stages of atrial fibrosis (7.71 vs. 9.53 vs. 5.72 vs. 15.88, from Stage I to Stage IV respectively, P = 0.115). Atrial fibrillation burden and recurrence after CA is similar between non-CHF and CHF patients, independent of the type of CHF. Of all CHF groups, those with HFrEF had the largest improvement in LVEF after CA. Moreover, the improvement in ventricular function seems to be independent of atrial fibrosis in patients with persistent AF.


  • Open Access

    Studying the Effect of Long COVID-19 Infection on Sleep Quality Using Wearable Health Devices: Observational Study

    by Mario Mekhael, Chan Ho Lim, Abdel Hadi El Hajjar, Charbel Noujaim, Christopher Pottle, Noor Makan, Lilas Dagher, Yichi Zhang, Nour Chouman, Dan L Li, et al.

    Background: Patients with COVID-19 have increased sleep disturbances and decreased sleep quality during and after the infection. The current published literature focuses mainly on qualitative analyses based on surveys and subjective measurements rather than quantitative data. Objective: In this paper, we assessed the long-term effects of COVID-19 through sleep patterns from continuous signals collected via wearable wristbands. Methods: Patients with a history of COVID-19 were compared to a control arm of individuals who never had COVID-19. Baseline demographics were collected for each subject. Linear correlations among the mean duration of each sleep phase and the mean daily biometrics were performed. The average duration for each subject’s total sleep time and sleep phases per night was calculated and compared between the 2 groups. Results: This study includes 122 patients with COVID-19 and 588 controls (N=710). Total sleep time was positively correlated with respiratory rate (RR) and oxygen saturation (SpO2). Increased awake sleep phase was correlated with increased heart rate, decreased RR, heart rate variability (HRV), and SpO2. Increased light sleep time was correlated with increased RR and SpO2 in the group with COVID-19. Deep sleep duration was correlated with decreased heart rate as well as increased RR and SpO2. When comparing different sleep phases, patients with long COVID-19 had decreased light sleep (244, SD 67 vs 258, SD 67; P=.003) and decreased deep sleep time (123, SD 66 vs 128, SD 58; P=.02). Conclusions: Regardless of the demographic background and symptom levels, patients with a history of COVID-19 infection demonstrated altered sleep architecture when compared to matched controls. The sleep of patients with COVID-19 was characterized by decreased total sleep and deep sleep.


  • Open Access

    Studying the Effect of Long COVID-19 Infection on Sleep Quality Using Wearable Health Devices: Observational Study (Preprint)

    by Mario Mekhael, Chan Ho Lim, Abdel Hadi El Hajjar, Charbel Noujaim, Christopher Pottle, Noor Makan, Lilas Dagher, Yichi Zhang, Nour Chouman, Dan L Li, et al.

    BACKGROUND Patients with COVID-19 have increased sleep disturbances and decreased sleep quality during and after the infection. The current published literature focuses mainly on qualitative analyses based on surveys and subjective measurements rather than quantitative data. OBJECTIVE In this paper, we assessed the long-term effects of COVID-19 through sleep patterns from continuous signals collected via wearable wristbands. METHODS Patients with a history of COVID-19 were compared to a control arm of individuals who never had COVID-19. Baseline demographics were collected for each subject. Linear correlations among the mean duration of each sleep phase and the mean daily biometrics were performed. The average duration for each subject’s total sleep time and sleep phases per night was calculated and compared between the 2 groups. RESULTS This study includes 122 patients with COVID-19 and 588 controls (N=710). Total sleep time was positively correlated with respiratory rate (RR) and oxygen saturation (SpO2). Increased awake sleep phase was correlated with increased heart rate, decreased RR, heart rate variability (HRV), and SpO2. Increased light sleep time was correlated with increased RR and SpO2 in the group with COVID-19. Deep sleep duration was correlated with decreased heart rate as well as increased RR and SpO2. When comparing different sleep phases, patients with long COVID-19 had decreased light sleep (244, SD 67 vs 258, SD 67; P=.003) and decreased deep sleep time (123, SD 66 vs 128, SD 58; P=.02). CONCLUSIONS Regardless of the demographic background and symptom levels, patients with a history of COVID-19 infection demonstrated altered sleep architecture when compared to matched controls. The sleep of patients with COVID-19 was characterized by decreased total sleep and deep sleep.

  • Open Access

    Acute Lesion Imaging in Predicting Chronic Tissue Injury in the Ventricles

    by Abdel Hadi El Hajjar, Chao Huang, Yichi Zhang, Mario Mekhael, Charbel Noujaim, Lilas Dagher, Saihariharan Nedunchezhian, Christopher Pottle, Eugene Kholmovski, Tarek Ayoub, et al.

    Background: Chronic lesion formation after cardiac tissue ablation is an important indicator for procedural outcome. Moreover, there is a lack of knowledge regarding the features that predict chronic lesion formation.Objective: The aim of this study is to determine whether acute lesion visualization using late gadolinium enhanced magnetic resonance imaging (LGE-MRI) can reliably predict chronic lesion size.Methods: Focal lesions were created in left and right ventricles of canine models using either radiofrequency (RF) ablation or cryofocal ablation. Multiple ablation parameters were used. The first LGE-MRI was acquired within 1–5 h post-ablation and the second LGE-MRI was obtained 47–82 days later. Corview software was used to perform lesion segmentations and size calculations.Results: Fifty-Five lesions were created in different locations in the ventricles. Chronic volume size decreased by a mean of 62.5 % (95% CI 58.83–67.97, p < 0.0005). Similar regression of lesion volume was observed regardless of ablation location (p = 0.32), ablation technique (p = 0.94), duration (p = 0.37), power (p = 0.55) and whether lesions were connected or not (p = 0.35). There was no significant difference in lesion volume reduction assessed at 47–54 days and 72–82 days after ablation (p = 0.31). Chronic lesion volume was equal to 0.32 of the acute lesion volumes (R2 = 0.75).Conclusion: Chronic tissue injury related to catheter ablation can be reliably modeled as a linear function of the acute lesion volume as assessed by LGE-MRI, regardless of the ablation parameters.


  • DEEP NEURAL NETWORK FOR ACCURATE AF DETECTION ON A SMARTPHONE-DERIVED SINGLE-LEAD ECG

    by Lilas Dagher, Chan Ho Lim, Aneesh Dhore, Michael Crawford, Tarek Ayoub, Nassir Marrouche

  • LEFT ATRIAL STRUCTURAL REMODELING IMPACTS THE FUNCTION OF THE LEFT ATRIUM IN ATRIAL FIBRILLATION PATIENTS: A MAGNETIC RESONANCE IMAGING STUDY

    by Lilas Dagher, Yichi Zhang, Aneesh Dhore, Michael Crawford, Alan Morris, Eugene Kholmovski, Tarek Ayoub, Raman Danrad, Chao Huang, Nassir Marrouche