Miren Itsaso Martinez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Miren Itsaso Martinez has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Gerardo Tapia-Otaegui
Department of Automatic Control and Systems Engineering University of the Basque Country UPV/EHU Donostia Spain ehu.eus
7 shared publications - Ana Susperregui
Department of Automatic Control and Systems Engineering, Faculty of Engineering–Gipuzkoa, University of the Basque Country UPV/EHU, Donostia, Spain
6 shared publications - Sebastian Gomez Jorge
Instituto de Investigaciones en Ingeniería Eléctrica “Alfredo Desages” (UNS-CONICET) and Departamento de Ingeniería Eléctrica y de Computadoras, Universidad Nacional del Sur, Bahía Blanca, Argentina
5 shared publications - Claudio Alberto Busada
Universidad Nacional del Sur, Bahía
4 shared publications - Jorge Alberto Solsona
Universidad Nacional del Sur, Bahía
4 shared publications Aitor Etxeberria
Department of Automatic Control and Systems Engineering (DACSE) of the Faculty of EngineeringGipuzkoa (FEG), University of the Basque Country UPV/EHU, Donostia, Spain
1 shared publication
Latest Publications
- Open Access
A Complex-Valued Feedback Linearization-Based Controller for a Voltage Source Inverter Tied to the Grid via a Second-Order Filter
In this document, a nonlinear control law for a grid-tied converter is introduced. The converter topology consists of a voltage source inverter (VSI) linked to the grid through an inductive-capacitive second-order filter, its input being connected to a capacitive DC-link supplied by a renewable energy-based input power source. In order to achieve good performance in presence of large state excursions caused mainly by substantial set-point modifications and/or considerable disturbances, a nonlinear control law based on a complex-valued feedback linearization strategy is designed. Specifically, a flat output is adopted, which is given by the summation of the energy stored in the DC-link capacitor and in the output filter's inductor and capacitor, as well as by the reactive energy at the output. After linearizing the system through a pertinent coordinate transformation and a nonlinear feedback, a linear trajectory tracking control law is implemented. The performance of the system controlled by applying the proposed strategy is tested via simulation for a very weak grid of unity X/R ratio, yielding satisfactory results.
Open AccessA Complex-Valued Feedback Linearization-Based Controller for a Voltage Source Inverter Tied to the Grid via a Second-Order Filter
In this document, a nonlinear control law for a grid-tied converter is introduced. The converter topology consists of a voltage source inverter (VSI) linked to the grid through an inductive-capacitive second-order filter, its input being connected to a capacitive DC-link supplied by a renewable energy-based input power source. In order to achieve good performance in presence of large state excursions caused mainly by substantial set-point modifications and/or considerable disturbances, a nonlinear control law based on a complex-valued feedback linearization strategy is designed. Specifically, a flat output is adopted, which is given by the summation of the energy stored in the DC-link capacitor and in the output filter's inductor and capacitor, as well as by the reactive energy at the output. After linearizing the system through a pertinent coordinate transformation and a nonlinear feedback, a linear trajectory tracking control law is implemented. The performance of the system controlled by applying the proposed strategy is tested via simulation for a very weak grid of unity X/R ratio, yielding satisfactory results.
- Open Access
- 10 January 2025
- Published by Elsevier in Control Engineering Practice
- Vol. 156
Complex-variable sliding-mode control of non-ideal grid-tied self-synchronized inverter for DC-link capacitance reduction
- 10 January 2025
- Published by Elsevier in Control Engineering Practice
- Vol. 156
Open AccessComplex-variable sliding-mode control of non-ideal grid-tied self-synchronized inverter for DC-link capacitance reduction
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (4) , 2781-2784
A Nonlinear Observer for Self-Synchronizing Grid-Tied Feeding Inverters
This paper proposes a solution for the self-synchronization of grid-tied feeding inverters. Since the proposed algorithm allows the self-synchronization, it avoids using a voltage sensor for measuring the Point of Common Coupling (PCC) voltage. The algorithm is based on an adaptive non-linear observer that uses the measurement of the output inductor current. Unlike synchronization schemes based on the virtual synchronous generator, which is often used in control strategies based on power synchronization, when combined with a non-linear control strategy, the proposed algorithm allows obtaining an excellent dynamic performance, even in presence of large PCC voltage disturbances and fast varying references. The performance of the proposed observer when combined with a non-linear control strategy, designed by considering the non-linear model of the converter, is illustrated through experimental results.
- 18 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 39 (4) , 2781-2784
A Nonlinear Observer for Self-Synchronizing Grid-Tied Feeding Inverters
This paper proposes a solution for the self-synchronization of grid-tied feeding inverters. Since the proposed algorithm allows the self-synchronization, it avoids using a voltage sensor for measuring the Point of Common Coupling (PCC) voltage. The algorithm is based on an adaptive non-linear observer that uses the measurement of the output inductor current. Unlike synchronization schemes based on the virtual synchronous generator, which is often used in control strategies based on power synchronization, when combined with a non-linear control strategy, the proposed algorithm allows obtaining an excellent dynamic performance, even in presence of large PCC voltage disturbances and fast varying references. The performance of the proposed observer when combined with a non-linear control strategy, designed by considering the non-linear model of the converter, is illustrated through experimental results.
- Open Access
Non-linear Control of the Power Injected Into a Weak Grid by a Self-Synchronized Inverter
In this work, a non-linear controller designed using non-linear transformation linearization and feedback is proposed for an inverter connected to a weak grid through a single-stage inductive filter. The proposed strategy is self-synchronized, so that it is not necessary to have a voltage sensor at the Point of Common Coupling (PCC). The strategy allows to robustify, in the presence of a weak grid, a strategy that has already been demonstrated to allow a significant reduction in the size of the DC-link capacitor of the converter. For this purpose, a state observer is designed that allows estimating the voltage at the PCC from the measurement of the output inductor current. A start-up controller is also included, which allows synchronization even in the case of system start-up. Simulation results are presented for different operating cases, including start-up, normal operation, and grid-voltage sags and swells. In all these cases, it is considered that the exact parameters of the grid to which the inverter is connected are unknown.
Open AccessNon-linear Control of the Power Injected Into a Weak Grid by a Self-Synchronized Inverter
In this work, a non-linear controller designed using non-linear transformation linearization and feedback is proposed for an inverter connected to a weak grid through a single-stage inductive filter. The proposed strategy is self-synchronized, so that it is not necessary to have a voltage sensor at the Point of Common Coupling (PCC). The strategy allows to robustify, in the presence of a weak grid, a strategy that has already been demonstrated to allow a significant reduction in the size of the DC-link capacitor of the converter. For this purpose, a state observer is designed that allows estimating the voltage at the PCC from the measurement of the output inductor current. A start-up controller is also included, which allows synchronization even in the case of system start-up. Simulation results are presented for different operating cases, including start-up, normal operation, and grid-voltage sags and swells. In all these cases, it is considered that the exact parameters of the grid to which the inverter is connected are unknown.
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (3) , 2157-2166
Nonlinear Controller Allowing the Use of a Small-Size DC-Link Capacitor in Grid-Feeding Converters
In this article, we propose an instantaneous complex power control (ICPC) for a grid-tied voltage-source converter, which has two important features: it allows injecting currents with low distortion to the grid, and it allows to significantly reduce the value of the dc link capacitor, which can potentially increase the reliability of the system and decrease its cost (considering different capacitor technologies). The proposal is based on finding the exact active power reference that the controller requires to keep the mean value of the energy in the dc link constant at all times. This means that, even when the loading conditions change, the mean value of the dc link voltage remains unchanged, allowing the reduction of the value of dc link capacitor. The proposed control scheme is validated both through simulations and experimental results.
- 1 May 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 71 (3) , 2157-2166
Nonlinear Controller Allowing the Use of a Small-Size DC-Link Capacitor in Grid-Feeding Converters
In this article, we propose an instantaneous complex power control (ICPC) for a grid-tied voltage-source converter, which has two important features: it allows injecting currents with low distortion to the grid, and it allows to significantly reduce the value of the dc link capacitor, which can potentially increase the reliability of the system and decrease its cost (considering different capacitor technologies). The proposal is based on finding the exact active power reference that the controller requires to keep the mean value of the energy in the dc link constant at all times. This means that, even when the loading conditions change, the mean value of the dc link voltage remains unchanged, allowing the reduction of the value of dc link capacitor. The proposed control scheme is validated both through simulations and experimental results.
- 11 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 13 (3) , 1566-1579
Sliding-Mode Control Algorithm for DFIG Synchronization to Unbalanced and Harmonically Distorted Grids
In order to smoothly connect to permanently disturbed grids, DFIG-based wind turbines must precisely synchronize the voltage induced at their open stator with that of the grid. Hence, aiming at addressing the still unpublished task of synchronizing DFIGs to simultaneously unbalanced and harmonically distorted grids, a phase-locked loop (PLL)-less and naturally chatter-free sliding-mode control (SMC) algorithm is proposed. The strategies developed so far were formulated considering synchronous reference frames. However, by designing a stationary reference frame-based solution, decomposition into positive- and negative-sequences and harmonic components is avoided. As a result, a relatively straightforward control structure with strong potential for industrialization is obtained, consisting of a single voltage loop per component with just one parameter to be tuned. The stability and robustness resulting from its application are analytically studied under both uncertainties and disturbances. Additionally, a simple method for rotor positioning, independent of grid disturbances, is provided. Simulation over a 2-MW DFIG model and rapid control prototyping (RCP) over a 7-kW DFIG experimental rig are carried out. In this way, the performance and robustness of the suggested control scheme are validated under both unbalanced and harmonically distorted grid voltage, substantial parameter deviations, and varying wind speed and grid frequency profiles.
- 11 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Sustainable Energy
- Vol. 13 (3) , 1566-1579
Sliding-Mode Control Algorithm for DFIG Synchronization to Unbalanced and Harmonically Distorted Grids
In order to smoothly connect to permanently disturbed grids, DFIG-based wind turbines must precisely synchronize the voltage induced at their open stator with that of the grid. Hence, aiming at addressing the still unpublished task of synchronizing DFIGs to simultaneously unbalanced and harmonically distorted grids, a phase-locked loop (PLL)-less and naturally chatter-free sliding-mode control (SMC) algorithm is proposed. The strategies developed so far were formulated considering synchronous reference frames. However, by designing a stationary reference frame-based solution, decomposition into positive- and negative-sequences and harmonic components is avoided. As a result, a relatively straightforward control structure with strong potential for industrialization is obtained, consisting of a single voltage loop per component with just one parameter to be tuned. The stability and robustness resulting from its application are analytically studied under both uncertainties and disturbances. Additionally, a simple method for rotor positioning, independent of grid disturbances, is provided. Simulation over a 2-MW DFIG model and rapid control prototyping (RCP) over a 7-kW DFIG experimental rig are carried out. In this way, the performance and robustness of the suggested control scheme are validated under both unbalanced and harmonically distorted grid voltage, substantial parameter deviations, and varying wind speed and grid frequency profiles.
- Open Access
Multi-Objective Optimisation-Based Tuning of Two Second-Order Sliding-Mode Controller Variants for DFIGs Connected to Non-Ideal Grid Voltage
In this paper, a posteriori multi-objective optimisation (MOO) is applied to tune the parameters of a second-order sliding-mode control (2-SMC) scheme commanding the grid-side converter (GSC) of a doubly-fed induction generator (DFIG) subject to unbalanced and harmonically distorted grid voltage. Two variants (i.e., design concepts) of the same 2-SMC algorithm are assessed, which only differ in the format of their switching functions and which contain six and four parameters to be adjusted, respectively. A single set of parameters which stays valid for nine different operating regimes of the DFIG is also sought. As two objectives, related to control performances of grid active and reactive powers, are established for each operating regime, the optimisation process considers 18 objectives simultaneously. A six-parameter set derived in a previous work without applying MOO is taken as reference solution. MOO results reveal that both the six- and four-parameter versions can be tuned to overcome said reference solution in each and every objective, as well as showing that performances comparable to those of the six-parameter variant can be achieved by adopting the four-parameter one. Overall, the experimental results confirm the latter and prove that the performance of the reference parameter set can be significantly improved by using either of the six- or four-parameter versions.
Open AccessMulti-Objective Optimisation-Based Tuning of Two Second-Order Sliding-Mode Controller Variants for DFIGs Connected to Non-Ideal Grid Voltage
In this paper, a posteriori multi-objective optimisation (MOO) is applied to tune the parameters of a second-order sliding-mode control (2-SMC) scheme commanding the grid-side converter (GSC) of a doubly-fed induction generator (DFIG) subject to unbalanced and harmonically distorted grid voltage. Two variants (i.e., design concepts) of the same 2-SMC algorithm are assessed, which only differ in the format of their switching functions and which contain six and four parameters to be adjusted, respectively. A single set of parameters which stays valid for nine different operating regimes of the DFIG is also sought. As two objectives, related to control performances of grid active and reactive powers, are established for each operating regime, the optimisation process considers 18 objectives simultaneously. A six-parameter set derived in a previous work without applying MOO is taken as reference solution. MOO results reveal that both the six- and four-parameter versions can be tuned to overcome said reference solution in each and every objective, as well as showing that performances comparable to those of the six-parameter variant can be achieved by adopting the four-parameter one. Overall, the experimental results confirm the latter and prove that the performance of the reference parameter set can be significantly improved by using either of the six- or four-parameter versions.
- Open Access
- 1 July 2017
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 11 (6) , 1013-1022
Second‐order sliding‐mode‐based global control scheme for wind turbine‐driven DFIGs subject to unbalanced and distorted grid voltage
Control algorithms for both the rotor‐ and grid‐side power converters of a wind turbine‐driven doubly‐fed induction generator (DFIG) are detailed, and tuning equations are also provided to assist adjustment of their gains and constants. Those algorithms are based on the second‐order sliding‐mode control (2‐SMC) approach, and they allow the wind turbine to satisfactorily operate under grid voltage non‐idealities, such as simultaneously distorted and unbalanced scenarios. The presented solution turns out to be robust against parameter deviations and disturbances, and of high‐performance dynamic response. Moreover, it drives the transistors of both power converters at a constant switching frequency, also avoiding decomposition in symmetrical sequences of either the grid voltage or currents. The controllers proposed for the two power converters are validated through experimentation on a 7‐kW DFIG test bench subject to a significantly unbalanced and harmonically distorted grid voltage. Their robustness in the presence of both substantial parameter mismatch and disturbances attributable to wind variability is also assessed.
- 1 July 2017
- Published by Institution of Engineering and Technology (IET) in IET Electric Power Applications
- Vol. 11 (6) , 1013-1022
Open AccessSecond‐order sliding‐mode‐based global control scheme for wind turbine‐driven DFIGs subject to unbalanced and distorted grid voltage
Control algorithms for both the rotor‐ and grid‐side power converters of a wind turbine‐driven doubly‐fed induction generator (DFIG) are detailed, and tuning equations are also provided to assist adjustment of their gains and constants. Those algorithms are based on the second‐order sliding‐mode control (2‐SMC) approach, and they allow the wind turbine to satisfactorily operate under grid voltage non‐idealities, such as simultaneously distorted and unbalanced scenarios. The presented solution turns out to be robust against parameter deviations and disturbances, and of high‐performance dynamic response. Moreover, it drives the transistors of both power converters at a constant switching frequency, also avoiding decomposition in symmetrical sequences of either the grid voltage or currents. The controllers proposed for the two power converters are validated through experimentation on a 7‐kW DFIG test bench subject to a significantly unbalanced and harmonically distorted grid voltage. Their robustness in the presence of both substantial parameter mismatch and disturbances attributable to wind variability is also assessed.