Pengcheng Du
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Pengcheng Du has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Jin Li
School of Instrumentation and Optoelectronic Engineering Beihang University Beijing China
5 shared publications - Feifan Yang
School of Instrumentation and Optoelectronic Engineering and the Institute of Large-Scale Scientific Facility and Centre for Zero Magnetic Field Science, Beihang University
4 shared publications Wei Quan
4 shared publicationsFeifan Yang
3 shared publications- Kai Zhang
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
3 shared publications - Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
3 shared publications
Latest Publications
- 23 February 2026
- Published by Elsevier in Measurement
- Vol. 271
Suppression of heading error induced by vector light shift in a CPT atomic magnetometer using a double-pass configuration
- 23 February 2026
- Published by Elsevier in Measurement
- Vol. 271
Suppression of heading error induced by vector light shift in a CPT atomic magnetometer using a double-pass configuration
- Top Cited Papers
- 11 February 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 198
A miniaturized atomic magnetometer enabled by cascaded metasurfaces
- 11 February 2026
- Published by Elsevier in Optics & Laser Technology
- Vol. 198
Top Cited PapersA miniaturized atomic magnetometer enabled by cascaded metasurfaces
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Single-Beam Optically Pumped Atomic Magnetometer With Suppression of Light Shift Based on Space-Division Multiplexing Light
Single-beam optically pumped atomic magnetometers (OPAMs) represent promising candidates for applications in geomagnetic field monitoring, biomedicine, and various other precision sensing domains owing to their exceptional sensitivity, high measurement accuracy, and cost-effectiveness. However, in orientation-based OPAMs utilizing circularly polarized light (CPL) pumping, the off-resonant light introduces light shift. The light shift acts as an additional magnetic field, reducing the measurement accuracy of OPAMs. Moreover, the dependence of the light shift on light intensity and frequency facilitates the conversion of light noise into magnetic noise, thereby degrading the sensitivity of OPAMs. In this study, we propose an optical pumping scheme based on space division multiplexing light (SDML) to suppress the light shift in OPAM. The approach employs two orthogonally polarized linearly polarized beams with a controlled phase difference to generate a spatially periodic distribution of left- and right-handed CPL. Optical pumping with the SDML induces oppositely directed light shifts in distinct spatial regions that effectively cancel each other. Finally, it is verified by experiments that the light shift is greatly suppressed based on SDML. Under detuned SDML pumping, both the light shift and light intensity noise are suppressed by over 50%, while maintaining a sensitivity comparable to that achieved with conventional CPL pumping. The proposed method demonstrates significant potential for magnetometers in light-noise-prone environments, and it can be generalized to other orientation-based magnetometers that rely on CPL pumping.
- 30 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-9
Single-Beam Optically Pumped Atomic Magnetometer With Suppression of Light Shift Based on Space-Division Multiplexing Light
Single-beam optically pumped atomic magnetometers (OPAMs) represent promising candidates for applications in geomagnetic field monitoring, biomedicine, and various other precision sensing domains owing to their exceptional sensitivity, high measurement accuracy, and cost-effectiveness. However, in orientation-based OPAMs utilizing circularly polarized light (CPL) pumping, the off-resonant light introduces light shift. The light shift acts as an additional magnetic field, reducing the measurement accuracy of OPAMs. Moreover, the dependence of the light shift on light intensity and frequency facilitates the conversion of light noise into magnetic noise, thereby degrading the sensitivity of OPAMs. In this study, we propose an optical pumping scheme based on space division multiplexing light (SDML) to suppress the light shift in OPAM. The approach employs two orthogonally polarized linearly polarized beams with a controlled phase difference to generate a spatially periodic distribution of left- and right-handed CPL. Optical pumping with the SDML induces oppositely directed light shifts in distinct spatial regions that effectively cancel each other. Finally, it is verified by experiments that the light shift is greatly suppressed based on SDML. Under detuned SDML pumping, both the light shift and light intensity noise are suppressed by over 50%, while maintaining a sensitivity comparable to that achieved with conventional CPL pumping. The proposed method demonstrates significant potential for magnetometers in light-noise-prone environments, and it can be generalized to other orientation-based magnetometers that rely on CPL pumping.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9535508
Nonlinear Zeeman Effect Suppression for CPT Atom Magnetometers
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 9535508
Nonlinear Zeeman Effect Suppression for CPT Atom Magnetometers
- 2 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28252-28264
Highly Uniform Field Three-Axis Coils Using Modified Grey-Wolf Optimizer for Atomic Magnetometers
Uniform magnetic field coils are important part in high-precision atomic magnetometers. Such as, in vector atomic magnetometers (need three axis uniform field coils). At present, the most widely used coils in atomic magnetometers is Helmholtz coils, which has insufficient magnetic field uniformity. With the miniaturization of high-precision atomic sensors, the conventional coils are inadequate to satisfy the magnetic field uniformity requirements when magnetometers reduce their overall volume. Modified-grey wolf optimizer/multiple objective grey wolf optimizer (MOD-GWO/MOGWO) modified is used for first time in three-axis uniform field coil design in this paper. Compared with the Helmholtz coil, the uniformity of the MOD-GWO/MOGWO coils is improved by 1-3 orders of magnitude along the axis [-1R, 1R]. In the core region, MOD-GWO/MOGWO coils also improve the uniformity compared to Helmholtz coils and other conventional coils. The areas where the relative uniformity of the axial coils and radial coils is below 3% obtained by actual measurement account for approximately 100% and 82.44% along the axis [-1R, 1R] respectively. The method this paper proposed (MOD-GWO combined with Taylor expansion method) balances the difficulty of mathematical derivation and the algorithm time consumption, space consumption, and modifies the initialization mechanism and convergence mechanism of the original GWO/MOGWO.
- 2 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (15) , 28252-28264
Highly Uniform Field Three-Axis Coils Using Modified Grey-Wolf Optimizer for Atomic Magnetometers
Uniform magnetic field coils are important part in high-precision atomic magnetometers. Such as, in vector atomic magnetometers (need three axis uniform field coils). At present, the most widely used coils in atomic magnetometers is Helmholtz coils, which has insufficient magnetic field uniformity. With the miniaturization of high-precision atomic sensors, the conventional coils are inadequate to satisfy the magnetic field uniformity requirements when magnetometers reduce their overall volume. Modified-grey wolf optimizer/multiple objective grey wolf optimizer (MOD-GWO/MOGWO) modified is used for first time in three-axis uniform field coil design in this paper. Compared with the Helmholtz coil, the uniformity of the MOD-GWO/MOGWO coils is improved by 1-3 orders of magnitude along the axis [-1R, 1R]. In the core region, MOD-GWO/MOGWO coils also improve the uniformity compared to Helmholtz coils and other conventional coils. The areas where the relative uniformity of the axial coils and radial coils is below 3% obtained by actual measurement account for approximately 100% and 82.44% along the axis [-1R, 1R] respectively. The method this paper proposed (MOD-GWO combined with Taylor expansion method) balances the difficulty of mathematical derivation and the algorithm time consumption, space consumption, and modifies the initialization mechanism and convergence mechanism of the original GWO/MOGWO.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Laser-Frequency Stabilization Using Doppler-Free Spectrum of 87Rb D1 Line Produced by Bichromatic Circularly Polarized Light
Coherent population trapping (CPT) magnetometers are important geomagnetic measurement tools. However, the shift and jitter of laser frequencies can seriously interfere with the measurement results of CPT magnetometers. A CPT magnetometer uses bichromatic light that reacts with alkali metal atoms to obtain magnetic field information. Therefore, traditional laser-frequency stabilization methods, which are primarily based on monochromatic light, are not suitable for CPT magnetometers. In this study, we propose a new laser-frequency stabilization method based on the Doppler-free spectrum of the 87Rb D1 line produced by bichromatic circularly polarized light. First, the bichromatic Doppler-free spectrum at the 87Rb D1 line was theoretically analyzed based on the energy level, which revealed that the Doppler-free spectrum produced by bichromatic circularly polarized light can exhibit a large amplitude in the geomagnetic field. Next, we used the bichromatic circularly polarized light to construct a self-assembly Doppler-free spectroscopy of the 87Rb D1 line to verify the proposed laser-frequency stabilization method. The experimental results demonstrate that the frequency stability within an integration period of 1 s was $5.74 \times 10^{-11}$ . When the integration time was 100 s, the frequency stability was $8.63 \times 10^{-11}$ . These results show that the proposed method is promising for ultrahigh-sensitivity CPT magnetometers, ensuring accurate measurements in practical applications.
- 4 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-7
Laser-Frequency Stabilization Using Doppler-Free Spectrum of 87Rb D1 Line Produced by Bichromatic Circularly Polarized Light
Coherent population trapping (CPT) magnetometers are important geomagnetic measurement tools. However, the shift and jitter of laser frequencies can seriously interfere with the measurement results of CPT magnetometers. A CPT magnetometer uses bichromatic light that reacts with alkali metal atoms to obtain magnetic field information. Therefore, traditional laser-frequency stabilization methods, which are primarily based on monochromatic light, are not suitable for CPT magnetometers. In this study, we propose a new laser-frequency stabilization method based on the Doppler-free spectrum of the 87Rb D1 line produced by bichromatic circularly polarized light. First, the bichromatic Doppler-free spectrum at the 87Rb D1 line was theoretically analyzed based on the energy level, which revealed that the Doppler-free spectrum produced by bichromatic circularly polarized light can exhibit a large amplitude in the geomagnetic field. Next, we used the bichromatic circularly polarized light to construct a self-assembly Doppler-free spectroscopy of the 87Rb D1 line to verify the proposed laser-frequency stabilization method. The experimental results demonstrate that the frequency stability within an integration period of 1 s was $5.74 \times 10^{-11}$ . When the integration time was 100 s, the frequency stability was $8.63 \times 10^{-11}$ . These results show that the proposed method is promising for ultrahigh-sensitivity CPT magnetometers, ensuring accurate measurements in practical applications.
- 23 February 2025
- Published by Elsevier in Measurement
- Vol. 250
A compact optically pumped potassium atomic magnetometer with high sensitivity under geomagnetic field intensity
- 23 February 2025
- Published by Elsevier in Measurement
- Vol. 250
A compact optically pumped potassium atomic magnetometer with high sensitivity under geomagnetic field intensity
- 11 December 2024
- Published by Elsevier in Measurement
- Vol. 243
A non-magnetic packaged Vertical-Cavity Surface-Emitting Laser for SERF magnetometers
- 11 December 2024
- Published by Elsevier in Measurement
- Vol. 243
A non-magnetic packaged Vertical-Cavity Surface-Emitting Laser for SERF magnetometers
- Open Access
Analysis and Selection of the Optimal Pump Laser Power Density for SERF Co-Magnetometer Used in Rotation Sensing
This paper systematically studies the output noise model of the K-Rb-21Ne co-magnetometer and proposes the method for determining the optimal pump laser power density. The amplitude-frequency response and the equivalent model for each frequency band are obtained through the transfer function of the co-magnetometer. Based on the established model and considering the power spectral density characteristics of magnetic noise, the output noise equation is formulated. Consequently, the pump laser power density yielding minimal output noise is determined. Both experimental and simulation results indicate that the pump laser power density yielding minimal output noise is greater than the pump laser power density corresponding to the maximum scale factor. Moreover, when the co-magnetometer operates at the pump laser power density corresponding to the minimal output noise, the output noise can be reduced by approximately 25%, and the Allan variance reaches its optimal value. The optimal Allan variance at 180 °C and 190 °C are 0.01395°/h @100 s and 0.01329°/h @100 s, respectively. Therefore, this pump laser power density is designated as the optimal pump laser power density for the co-magnetometer. Finally, simulations are conducted to investigate the variation patterns of the optimal pump laser power density points and the minimum output noise under different density ratios and gas pressures. The theories and methods proposed in this paper provide significant reference value for selecting the optimal pump laser power density and suppressing magnetic noise in co-magnetometers.
Open AccessAnalysis and Selection of the Optimal Pump Laser Power Density for SERF Co-Magnetometer Used in Rotation Sensing
This paper systematically studies the output noise model of the K-Rb-21Ne co-magnetometer and proposes the method for determining the optimal pump laser power density. The amplitude-frequency response and the equivalent model for each frequency band are obtained through the transfer function of the co-magnetometer. Based on the established model and considering the power spectral density characteristics of magnetic noise, the output noise equation is formulated. Consequently, the pump laser power density yielding minimal output noise is determined. Both experimental and simulation results indicate that the pump laser power density yielding minimal output noise is greater than the pump laser power density corresponding to the maximum scale factor. Moreover, when the co-magnetometer operates at the pump laser power density corresponding to the minimal output noise, the output noise can be reduced by approximately 25%, and the Allan variance reaches its optimal value. The optimal Allan variance at 180 °C and 190 °C are 0.01395°/h @100 s and 0.01329°/h @100 s, respectively. Therefore, this pump laser power density is designated as the optimal pump laser power density for the co-magnetometer. Finally, simulations are conducted to investigate the variation patterns of the optimal pump laser power density points and the minimum output noise under different density ratios and gas pressures. The theories and methods proposed in this paper provide significant reference value for selecting the optimal pump laser power density and suppressing magnetic noise in co-magnetometers.
- 1 August 2024
- Published by Wiley in Advanced Quantum Technologies
- Vol. 7 (10)
Spin Polarization Measurement in SERF Comagnetometer Based on Phase‐Frequency Response of Magnetic Field
This work presents an innovative approach for measuring the spin polarizations of coupled atomic ensembles in spin‐exchange relaxation‐free (SERF) comagnetometers, using the phase‐frequency response of the magnetic field. The zero‐phase point in the phase‐frequency response of the magnetic field along the ‐axis is examined to determine the deceleration factor and electronic magnetic field. Ultimately, the spin polarizations of electrons and noble‐gas atoms are calculated. The method is applied to test vapor cells with different parameters under various temperatures and pumping light intensities. The measurement errors caused by transverse electron relaxation of electronic spin polarization and nuclear spin polarization are 5.59% and 1.95% under high polarization, and 8.06% and 2.62% under low polarization. The measurement method features minimal impact on nuclear spin polarization and wide applicability compared to other methods, making it more applicable and suitable for SERF comagnetometers. This method has great significance in better understanding the system state of the SERF comagnetometer and improving its sensitivity.
- 1 August 2024
- Published by Wiley in Advanced Quantum Technologies
- Vol. 7 (10)
Spin Polarization Measurement in SERF Comagnetometer Based on Phase‐Frequency Response of Magnetic Field
This work presents an innovative approach for measuring the spin polarizations of coupled atomic ensembles in spin‐exchange relaxation‐free (SERF) comagnetometers, using the phase‐frequency response of the magnetic field. The zero‐phase point in the phase‐frequency response of the magnetic field along the ‐axis is examined to determine the deceleration factor and electronic magnetic field. Ultimately, the spin polarizations of electrons and noble‐gas atoms are calculated. The method is applied to test vapor cells with different parameters under various temperatures and pumping light intensities. The measurement errors caused by transverse electron relaxation of electronic spin polarization and nuclear spin polarization are 5.59% and 1.95% under high polarization, and 8.06% and 2.62% under low polarization. The measurement method features minimal impact on nuclear spin polarization and wide applicability compared to other methods, making it more applicable and suitable for SERF comagnetometers. This method has great significance in better understanding the system state of the SERF comagnetometer and improving its sensitivity.