Kai Zhang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kai Zhang has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Wei Quan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
5 shared publications - Wenfeng Fan
School of Instrumentation and Optoelectronic Engineering, Beihang University 1 , Beijing 100191
4 shared publications - Linlin Yuan
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
3 shared publications - Pengcheng Du
Key Laboratory of Ultra-Weak Magnetic Field Measurement Technology, Ministry of Education, School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
3 shared publications - Hang Gao
Beihang University
2 shared publications - Ze Cai
School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China
2 shared publications
Latest Publications
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Shipborne Experimental Demonstration of an Atomic Spin Comagnetometer for Dual-Axis Rotation Sensing
Rotation sensing is essential for both fundamental physics and inertial navigation. The atomic spin comagnetometer is a promising candidate for high-precision gyroscopes, owing to its exceptional sensitivity. A key challenge lies in the coupling between magnetic field and rotation inputs, which degrades rotation measurement precision and affects the bias stability of the gyroscope. This study reports the first shipborne demonstration of a dual-axis comagnetometer for rotation sensing, confirming its viability for marine environments. By applying a rotating magnetic field orthogonal to the pump beam, a four-channel system is constructed to simultaneously sense dual-axis magnetic field and rotation. A linearized input–output model supports real-time, decoupled estimation of both inputs. Sea trials confirm that the comagnetometer can reliably monitor the pitch and yaw angular velocities of the vessel over extended durations. The time-domain outputs show good agreement with those from fiber-optic gyroscopes, demonstrating high accuracy and dynamic tracking performance. This study represents a significant step toward transforming atomic spin comagnetometers into practical, high-precision inertial sensors for real-world marine navigation.
- 20 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-10
Shipborne Experimental Demonstration of an Atomic Spin Comagnetometer for Dual-Axis Rotation Sensing
Rotation sensing is essential for both fundamental physics and inertial navigation. The atomic spin comagnetometer is a promising candidate for high-precision gyroscopes, owing to its exceptional sensitivity. A key challenge lies in the coupling between magnetic field and rotation inputs, which degrades rotation measurement precision and affects the bias stability of the gyroscope. This study reports the first shipborne demonstration of a dual-axis comagnetometer for rotation sensing, confirming its viability for marine environments. By applying a rotating magnetic field orthogonal to the pump beam, a four-channel system is constructed to simultaneously sense dual-axis magnetic field and rotation. A linearized input–output model supports real-time, decoupled estimation of both inputs. Sea trials confirm that the comagnetometer can reliably monitor the pitch and yaw angular velocities of the vessel over extended durations. The time-domain outputs show good agreement with those from fiber-optic gyroscopes, demonstrating high accuracy and dynamic tracking performance. This study represents a significant step toward transforming atomic spin comagnetometers into practical, high-precision inertial sensors for real-world marine navigation.
- Top Cited Papers
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2793-2804
High-Precision In Situ Control of Transverse Magnetic Field in ASGs Based on High-Frequency Modulation and Transient Response
The coupling between the transverse magnetic field and the angular velocity in atomic spin gyroscopes (ASGs) makes it difficult to achieve high-precision in situ closed-loop control, which seriously affects the long-term stability of the gyroscopes. This article innovatively proposes a transverse magnetic field closed-loop control method based on high-frequency modulation and transient response. A steady-state response model for the electron spin–nuclear spin coupling ensemble based on high-frequency modulation is established, enabling high-precision in situ measurement of the transverse magnetic field. A method for decoupling the transverse magnetic field and angular velocity based on transient response is proposed. Based on the above, a transverse magnetic field closed-loop control scheme is designed, achieving high-precision in situ closed-loop control in the ASGs for the first time. Experimental results demonstrate that the sensitivities of in situ transverse magnetic field measurements reach 50 and 110 fT/Hz$\mathbf {^{1/2}}$, respectively. The inertial sensitivity of the ASGs is improved by 23.8$\%$ to $\mathbf {6.30 \times {10^{ - 6}}}^{\circ }$/s/Hz$\mathbf {^{1/2}}$, and the bias instability is reduced by 31.3$\%$ to $\mathbf {9.04 \times {10^{-3}}}^{\circ }$/h. This approach is of great significance for improving the anti-interference capability of ASGs and broadening their application range.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 31 (3) , 2793-2804
Top Cited PapersHigh-Precision In Situ Control of Transverse Magnetic Field in ASGs Based on High-Frequency Modulation and Transient Response
The coupling between the transverse magnetic field and the angular velocity in atomic spin gyroscopes (ASGs) makes it difficult to achieve high-precision in situ closed-loop control, which seriously affects the long-term stability of the gyroscopes. This article innovatively proposes a transverse magnetic field closed-loop control method based on high-frequency modulation and transient response. A steady-state response model for the electron spin–nuclear spin coupling ensemble based on high-frequency modulation is established, enabling high-precision in situ measurement of the transverse magnetic field. A method for decoupling the transverse magnetic field and angular velocity based on transient response is proposed. Based on the above, a transverse magnetic field closed-loop control scheme is designed, achieving high-precision in situ closed-loop control in the ASGs for the first time. Experimental results demonstrate that the sensitivities of in situ transverse magnetic field measurements reach 50 and 110 fT/Hz$\mathbf {^{1/2}}$, respectively. The inertial sensitivity of the ASGs is improved by 23.8$\%$ to $\mathbf {6.30 \times {10^{ - 6}}}^{\circ }$/s/Hz$\mathbf {^{1/2}}$, and the bias instability is reduced by 31.3$\%$ to $\mathbf {9.04 \times {10^{-3}}}^{\circ }$/h. This approach is of great significance for improving the anti-interference capability of ASGs and broadening their application range.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 370-381
Analysis and Suppression of Optical-Magnetic Misalignment in an Atomic Comagnetometer
Ultra-sensitive atomic comagnetometers are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this paper, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness are verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the atomic comagnetometers.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (1) , 370-381
Analysis and Suppression of Optical-Magnetic Misalignment in an Atomic Comagnetometer
Ultra-sensitive atomic comagnetometers are invaluable tools for both inertial measurement and fundamental physics research. However, the misalignment between the pump light and the main magnetic field affects the polarization characteristics of nuclear spins of the noble gas atoms, making it a significant source of noise. In this paper, an atomic magnetometer response model with the optical-magnetic misalignment error is established, and the mechanism of the influence of optical-magnetic misalignment on nuclear spin polarization is analyzed. An in situ evaluation method and a suppression method of optical-magnetic misalignment error are proposed, and their effectiveness are verified through experiments with varying pump light incidence directions. The experimental results indicate that after optical-magnetic alignment using the proposed method, the spin polarization of the coupled atomic ensemble is enhanced by 20.7%, and the longitudinal relaxation rate of the nuclear spin is reduced by 6.9%. Additionally, the amplitude-frequency response of the x-axis magnetic field is reduced by 33.2% at 1 Hz and by 53.1% at frequencies below 0.002Hz. This indicates an improvement in the transverse magnetic field error suppression capability of the atomic comagnetometers.
- Open Access
Analysis and Selection of the Optimal Pump Laser Power Density for SERF Co-Magnetometer Used in Rotation Sensing
This paper systematically studies the output noise model of the K-Rb-21Ne co-magnetometer and proposes the method for determining the optimal pump laser power density. The amplitude-frequency response and the equivalent model for each frequency band are obtained through the transfer function of the co-magnetometer. Based on the established model and considering the power spectral density characteristics of magnetic noise, the output noise equation is formulated. Consequently, the pump laser power density yielding minimal output noise is determined. Both experimental and simulation results indicate that the pump laser power density yielding minimal output noise is greater than the pump laser power density corresponding to the maximum scale factor. Moreover, when the co-magnetometer operates at the pump laser power density corresponding to the minimal output noise, the output noise can be reduced by approximately 25%, and the Allan variance reaches its optimal value. The optimal Allan variance at 180 °C and 190 °C are 0.01395°/h @100 s and 0.01329°/h @100 s, respectively. Therefore, this pump laser power density is designated as the optimal pump laser power density for the co-magnetometer. Finally, simulations are conducted to investigate the variation patterns of the optimal pump laser power density points and the minimum output noise under different density ratios and gas pressures. The theories and methods proposed in this paper provide significant reference value for selecting the optimal pump laser power density and suppressing magnetic noise in co-magnetometers.
Open AccessAnalysis and Selection of the Optimal Pump Laser Power Density for SERF Co-Magnetometer Used in Rotation Sensing
This paper systematically studies the output noise model of the K-Rb-21Ne co-magnetometer and proposes the method for determining the optimal pump laser power density. The amplitude-frequency response and the equivalent model for each frequency band are obtained through the transfer function of the co-magnetometer. Based on the established model and considering the power spectral density characteristics of magnetic noise, the output noise equation is formulated. Consequently, the pump laser power density yielding minimal output noise is determined. Both experimental and simulation results indicate that the pump laser power density yielding minimal output noise is greater than the pump laser power density corresponding to the maximum scale factor. Moreover, when the co-magnetometer operates at the pump laser power density corresponding to the minimal output noise, the output noise can be reduced by approximately 25%, and the Allan variance reaches its optimal value. The optimal Allan variance at 180 °C and 190 °C are 0.01395°/h @100 s and 0.01329°/h @100 s, respectively. Therefore, this pump laser power density is designated as the optimal pump laser power density for the co-magnetometer. Finally, simulations are conducted to investigate the variation patterns of the optimal pump laser power density points and the minimum output noise under different density ratios and gas pressures. The theories and methods proposed in this paper provide significant reference value for selecting the optimal pump laser power density and suppressing magnetic noise in co-magnetometers.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Analysis and Suppression of the Detection System Polarization Error Caused by Residual Angle in a K–Rb–21Ne Comagnetometer
This paper investigates the detection system polarization error (DSPE) of the optical rotation detection system (ORDS) in a K–Rb– 21 Ne comagnetometer operating in the spin-exchange relaxation free (SERF) regime. The residual angle will couple the DSPE into the output signal, which will seriously degrade the performance of the ORDS. By establishing the mathematical model of scale factor, scale factor nonlinearity and sensitivity coefficient of probe laser intensity, the polarization error introduced by residual angle is analyzed. The experimental results show that after eliminating the residual angle, the scale factor of the system is effectively improved, the coupling effect between the probe laser intensity fluctuation and output signal is decreased, DSPE is effectively suppressed, and the sensitivity performance of the K–Rb– 21 Ne comagnetometer is improved. Then, an azimuth closed-loop device (ACD) is proposed, which utilizes the characteristics of Liquid-crystal variable retarder (LCVR) and a quarter-wave plate (QWP) to overcome the precision limit of manual adjustment and realize the long-term closed-loop elimination of residual angle, and suppress the DSPE. After adding ACD, DSPE is further suppressed, the sensitivity at 1Hz is improved more than 20% higher than that in open-loop mode. Moreover, the DSPE suppression method proposed in this paper also has the potential to be applied to other atomic sensors.
- 8 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-10
Analysis and Suppression of the Detection System Polarization Error Caused by Residual Angle in a K–Rb–21Ne Comagnetometer
This paper investigates the detection system polarization error (DSPE) of the optical rotation detection system (ORDS) in a K–Rb– 21 Ne comagnetometer operating in the spin-exchange relaxation free (SERF) regime. The residual angle will couple the DSPE into the output signal, which will seriously degrade the performance of the ORDS. By establishing the mathematical model of scale factor, scale factor nonlinearity and sensitivity coefficient of probe laser intensity, the polarization error introduced by residual angle is analyzed. The experimental results show that after eliminating the residual angle, the scale factor of the system is effectively improved, the coupling effect between the probe laser intensity fluctuation and output signal is decreased, DSPE is effectively suppressed, and the sensitivity performance of the K–Rb– 21 Ne comagnetometer is improved. Then, an azimuth closed-loop device (ACD) is proposed, which utilizes the characteristics of Liquid-crystal variable retarder (LCVR) and a quarter-wave plate (QWP) to overcome the precision limit of manual adjustment and realize the long-term closed-loop elimination of residual angle, and suppress the DSPE. After adding ACD, DSPE is further suppressed, the sensitivity at 1Hz is improved more than 20% higher than that in open-loop mode. Moreover, the DSPE suppression method proposed in this paper also has the potential to be applied to other atomic sensors.
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Markov Noise in Atomic Spin Gyroscopes: Analysis and Suppression Based on Allan Deviation
Atomic spin gyroscopes (ASGs) based on Spin-Exchange Relaxation-Free co-magnetometer have ultra-high rotation sensitivity and low gyro drift. However, the noise characteristics of ASGs have not been comprehensively studied. In this paper, the primary noise in ASGs which weakens the gyro’s long-term stability is analyzed and identified with Allan deviation. We discovered for the first time that the slow convergence rate of the spin-coupled ensemble brings a long correlation time of the gyro output and the Markov noise introduced by this effect is the primary noise that impacts the long-term stability of ASGs. Allan deviation is used to assess the characteristics of Markov noise and its impact on long-term stability. The correlation time is adjusted by changing the pumping power density to suppress the Markov noise. Comparing the Allan deviations under different correlation time, it’s concluded that the Markov noise caused by long correlation time restricts the improvement of the long-term stability of ASGs. Moreover, Markov noise at low frequencies is suppressed by increasing the pumped optical power density, enhancing the rotation sensitivity of ASGs. A relatively low gyro drift 5.76×10-3 °/h@100s is acquired after the suppression of the Markov noise. Different from traditional amplitude-frequency response analysis, this paper focuses on the time correlation of noise, which provides a new idea for the investigation of ASG’s noise characteristics.
- 27 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 72 (00189456) , 1-9
Markov Noise in Atomic Spin Gyroscopes: Analysis and Suppression Based on Allan Deviation
Atomic spin gyroscopes (ASGs) based on Spin-Exchange Relaxation-Free co-magnetometer have ultra-high rotation sensitivity and low gyro drift. However, the noise characteristics of ASGs have not been comprehensively studied. In this paper, the primary noise in ASGs which weakens the gyro’s long-term stability is analyzed and identified with Allan deviation. We discovered for the first time that the slow convergence rate of the spin-coupled ensemble brings a long correlation time of the gyro output and the Markov noise introduced by this effect is the primary noise that impacts the long-term stability of ASGs. Allan deviation is used to assess the characteristics of Markov noise and its impact on long-term stability. The correlation time is adjusted by changing the pumping power density to suppress the Markov noise. Comparing the Allan deviations under different correlation time, it’s concluded that the Markov noise caused by long correlation time restricts the improvement of the long-term stability of ASGs. Moreover, Markov noise at low frequencies is suppressed by increasing the pumped optical power density, enhancing the rotation sensitivity of ASGs. A relatively low gyro drift 5.76×10-3 °/h@100s is acquired after the suppression of the Markov noise. Different from traditional amplitude-frequency response analysis, this paper focuses on the time correlation of noise, which provides a new idea for the investigation of ASG’s noise characteristics.