Vadym Kedych
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Vadym Kedych has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
- Aldo Mozzanica
Paul Scherrer Institut, Forschungsstrasse 111, 5232 Villigen PSI, Switzerland
2 shared publications Alice Mazzoleni
Paul Scherrer Institute
2 shared publications- Anna Bergamaschi
Paul Scherrer Institute
2 shared publications Carlos Lopez-Cuenca
Paul Scherrer Institute
2 shared publicationsChristian Ruder
Paul Scherrer Institute
2 shared publicationsDavide Mezza
Paul Scherrer Institute
2 shared publications
Latest Publications
- Open Access
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6737-6744
Trench-Isolated LGAD Sensors for Time-Resolved STXM
- 1 November 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electron Devices
- Vol. 73 (11) , 6737-6744
Open AccessTrench-Isolated LGAD Sensors for Time-Resolved STXM
- Open Access
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10029
Fundamental characterisation of CdZnTe (CZT) and CdTe as sensor materials for the JUNGFRAU charge-integrating ASIC
The upgraded Swiss Light Source (SLS 2.0) increases the need for high-Z detector systems with improved detection efficiency for hard X-rays compared with silicon. Two candidate high-Z sensor materials, cadmium zinc telluride (CZT) and cadmium telluride (CdTe), have undergone fundamental characterisation at PSI using the JUNGFRAU readout ASIC. Two variants of each material were investigated: Schottky and Ohmic CdTe, and spectroscopic and high-flux CZT. Measurements include current-voltage characteristics, pixel-resolved leakage current and noise, flat-field response, and energy resolution. Both CZT sensors exhibited a very low mean leakage current of 0.60 pA and 0.18 pA per pixel for spectroscopic and high-flux CZT, respectively. Ohmic CdTe showed a substantially higher mean leakage current of 65.81 pA per pixel, while Schottky CdTe showed much lower mean leakage current (0.62 pA) but contained a significant population of high-leakage-current pixels. At 59.54 keV, both CZT sensors achieved an energy resolution of approximately 3.5 keV FWHM using 3×3 clusters, compared with 4.3 keV for Ohmic CdTe and 5.9 keV for Schottky CdTe. Ohmic CdTe additionally required approximately two hours after biasing for its leakage current and pedestal to stabilise. Both CZT sensors could be operated at full duty cycle with a 500 μs exposure time, with only a small reduction in available dynamic range. Overall, the CZT sensors showed the most favourable performance of the devices investigated, although further measurements across a larger number of sensors are required to assess sensor-to-sensor variation and production yield.
- 1 October 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (10) , P10029
Open AccessFundamental characterisation of CdZnTe (CZT) and CdTe as sensor materials for the JUNGFRAU charge-integrating ASIC
The upgraded Swiss Light Source (SLS 2.0) increases the need for high-Z detector systems with improved detection efficiency for hard X-rays compared with silicon. Two candidate high-Z sensor materials, cadmium zinc telluride (CZT) and cadmium telluride (CdTe), have undergone fundamental characterisation at PSI using the JUNGFRAU readout ASIC. Two variants of each material were investigated: Schottky and Ohmic CdTe, and spectroscopic and high-flux CZT. Measurements include current-voltage characteristics, pixel-resolved leakage current and noise, flat-field response, and energy resolution. Both CZT sensors exhibited a very low mean leakage current of 0.60 pA and 0.18 pA per pixel for spectroscopic and high-flux CZT, respectively. Ohmic CdTe showed a substantially higher mean leakage current of 65.81 pA per pixel, while Schottky CdTe showed much lower mean leakage current (0.62 pA) but contained a significant population of high-leakage-current pixels. At 59.54 keV, both CZT sensors achieved an energy resolution of approximately 3.5 keV FWHM using 3×3 clusters, compared with 4.3 keV for Ohmic CdTe and 5.9 keV for Schottky CdTe. Ohmic CdTe additionally required approximately two hours after biasing for its leakage current and pedestal to stabilise. Both CZT sensors could be operated at full duty cycle with a 500 μs exposure time, with only a small reduction in available dynamic range. Overall, the CZT sensors showed the most favourable performance of the devices investigated, although further measurements across a larger number of sensors are required to assess sensor-to-sensor variation and production yield.
- Open Access
- 25 June 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1039
LGAD technology for HADES, accelerator and medical applications
- 25 June 2022
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1039
Open AccessLGAD technology for HADES, accelerator and medical applications