Christopher Grilli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christopher Grilli has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Kamel Abdel Aal
Department of Interventional Radiology, The University of Texas Health Science Center at Houston, Houston, TX 77030, USA
2 shared publications - Andrew S. Kennedy
Sarah Cannon Research Institute, Nashville, Tennessee
2 shared publications - Daniel B. Brown
Department of Radiology, Vanderbilt University Medical Center, Nashville, Tennessee
2 shared publications - Daniel Y. Sze
Division of Interventional Radiology, Stanford University, Stanford, California
2 shared publications Eric A. Wang
Division of Interventional Radiology, Carolinas Medical Center, Charlotte, North Carolina
2 shared publications- Lea Matsuoka
Division of Hepatobiliary Surgery and Liver Transplantation, Vanderbilt University Medical Center, Nashville, Tennessee
2 shared publications
Latest Publications
- Open Access
- 18 November 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1)
Comparative analysis of occlusion efficiency of 0.018 detachable coils in a porcine model
Purpose: To compare the procedural occlusion efficiency of common 0.018-inch detachable peripheral fibered and non-fibered embolization coils, using commercially available coil lengths, in a porcine arterial model, evaluating differences in total implanted length, time to occlusion, fluoroscopy time, and packing density. Materials and methods: Ten paired arterial sites across three swine models were embolized using 4 mm and 6 mm detachable coils. Comparisons included Embold™ Soft vs. Concerto™ Helix (4 mm), Embold Soft vs. Ruby Soft (6 mm), and Embold Fibered vs. Ruby® Standard (6 mm). Modified Thrombolysis in Myocardial Infarction (TIMI) flow grade determined progression toward occlusion. Results: Among soft coils, 4 mm Embold Soft required fewer coils on average to achieve occlusion than Concerto (1.3 ± 0.6 vs. 3.7 ± 0.6, 95% CI of 0.9, 3.8) and achieved faster average occlusion time (3:46 ± 1:54 vs. 13:50 ± 3:36, 95% CI of 0:52, 19:17). 6 mm Embold Soft required fewer coils on average to achieve occlusion than Ruby Soft (2.0 ± 1.0 vs. 4.7 ± 2.1, 95% CI of − 4.5, 9.8) and achieved faster average occlusion time (6:43 ± 4:12 vs. 19:9 ± 11:6, 95% CI of -23:29, 48:21 min:seconds). On average, Embold Fibered required fewer coils than Ruby Standard (2.8 ± 0.5 vs. 5.3 ± 1.7, 95% CI of 0.4, 4.6), less total implanted coil length (55 ± 10 cm vs. 105 ± 34 cm, 95% CI of 8.95 cm, 91.1 cm), and shorter time to occlusion (9:16 ± 2:23 vs. 20:26 ± 6:49, 95% CI from 2:08 to 20:12 min:seconds). Conclusions: In an acute, heparinized porcine model with a single operator and TIMI-based angiographic assessments, Embold Soft achieved occlusion with fewer coil deployments and in a shorter time, on average, than Concerto and Ruby Soft. This was observed when evaluating the longest commercially available coils of each type (4 mm × 30 cm Embold Soft vs. 4 mm × 10 cm Concerto and 6 mm × 60 cm Embold Soft vs. 6 mm × 30 cm Ruby Soft). Additionally, Embold Fibered achieved occlusion with fewer coils, less coil length, and in a shorter time, on average, than Ruby Standard when evaluating identical coil lengths (6 mm × 20 cm).
- 18 November 2026
- Published by Springer Nature in CVIR Endovascular
- Vol. 9 (1)
Open AccessComparative analysis of occlusion efficiency of 0.018 detachable coils in a porcine model
Purpose: To compare the procedural occlusion efficiency of common 0.018-inch detachable peripheral fibered and non-fibered embolization coils, using commercially available coil lengths, in a porcine arterial model, evaluating differences in total implanted length, time to occlusion, fluoroscopy time, and packing density. Materials and methods: Ten paired arterial sites across three swine models were embolized using 4 mm and 6 mm detachable coils. Comparisons included Embold™ Soft vs. Concerto™ Helix (4 mm), Embold Soft vs. Ruby Soft (6 mm), and Embold Fibered vs. Ruby® Standard (6 mm). Modified Thrombolysis in Myocardial Infarction (TIMI) flow grade determined progression toward occlusion. Results: Among soft coils, 4 mm Embold Soft required fewer coils on average to achieve occlusion than Concerto (1.3 ± 0.6 vs. 3.7 ± 0.6, 95% CI of 0.9, 3.8) and achieved faster average occlusion time (3:46 ± 1:54 vs. 13:50 ± 3:36, 95% CI of 0:52, 19:17). 6 mm Embold Soft required fewer coils on average to achieve occlusion than Ruby Soft (2.0 ± 1.0 vs. 4.7 ± 2.1, 95% CI of − 4.5, 9.8) and achieved faster average occlusion time (6:43 ± 4:12 vs. 19:9 ± 11:6, 95% CI of -23:29, 48:21 min:seconds). On average, Embold Fibered required fewer coils than Ruby Standard (2.8 ± 0.5 vs. 5.3 ± 1.7, 95% CI of 0.4, 4.6), less total implanted coil length (55 ± 10 cm vs. 105 ± 34 cm, 95% CI of 8.95 cm, 91.1 cm), and shorter time to occlusion (9:16 ± 2:23 vs. 20:26 ± 6:49, 95% CI from 2:08 to 20:12 min:seconds). Conclusions: In an acute, heparinized porcine model with a single operator and TIMI-based angiographic assessments, Embold Soft achieved occlusion with fewer coil deployments and in a shorter time, on average, than Concerto and Ruby Soft. This was observed when evaluating the longest commercially available coils of each type (4 mm × 30 cm Embold Soft vs. 4 mm × 10 cm Concerto and 6 mm × 60 cm Embold Soft vs. 6 mm × 30 cm Ruby Soft). Additionally, Embold Fibered achieved occlusion with fewer coils, less coil length, and in a shorter time, on average, than Ruby Standard when evaluating identical coil lengths (6 mm × 20 cm).
- 13 November 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
OCCLUDE: Final Results from the Prospective Multicenter Real-World Study
- 13 November 2026
- Published by Elsevier in Journal of Vascular and Interventional Radiology
OCCLUDE: Final Results from the Prospective Multicenter Real-World Study
- 12 October 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (1) , 116-123.e1
A Comparison of Postprocedural Hemoglobin in Catheter-Directed Thrombolysis versus Large-Bore Aspiration Thrombectomy for Acute Pulmonary Embolism
- 12 October 2024
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 36 (1) , 116-123.e1
A Comparison of Postprocedural Hemoglobin in Catheter-Directed Thrombolysis versus Large-Bore Aspiration Thrombectomy for Acute Pulmonary Embolism
- 7 May 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (8) , 1424-1427
Exposure to IR Rotations in Osteopathic Medical Schools: Trends in Residency Applications and Matching
- 7 May 2023
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (8) , 1424-1427
Exposure to IR Rotations in Osteopathic Medical Schools: Trends in Residency Applications and Matching
- 9 December 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (4) , 694-701.e3
Survival and Toxicities after Yttrium-90 Transarterial Radioembolization of Cholangiocarcinoma in the RESiN Registry
- 9 December 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 34 (4) , 694-701.e3
Survival and Toxicities after Yttrium-90 Transarterial Radioembolization of Cholangiocarcinoma in the RESiN Registry
- 1 October 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (1) , 228-236
Survival and Toxicities after 90Y Transarterial Radioembolization of Metastatic Colorectal Cancer in the RESIN Registry
Transarterial radioembolization with yttrium 90 microspheres resulted in 15.0-month overall survival in 498 participants with metastatic colorectal cancer: 17.4 months when integrated with second-l... Background Patients with unresectable, chemorefractory hepatic metastases from colorectal cancer have considerable mortality. The role of transarterial radioembolization (TARE) with yttrium 90 (90Y...
- 1 October 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (1) , 228-236
Survival and Toxicities after 90Y Transarterial Radioembolization of Metastatic Colorectal Cancer in the RESIN Registry
Transarterial radioembolization with yttrium 90 microspheres resulted in 15.0-month overall survival in 498 participants with metastatic colorectal cancer: 17.4 months when integrated with second-l... Background Patients with unresectable, chemorefractory hepatic metastases from colorectal cancer have considerable mortality. The role of transarterial radioembolization (TARE) with yttrium 90 (90Y...
- Open Access
- 1 March 2012
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 23 (3) , S117-S118
Abstract No. 290: Aggressive management of chronic deep venous thrombosis: technical and clinical outcomes
- 1 March 2012
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 23 (3) , S117-S118
Open AccessAbstract No. 290: Aggressive management of chronic deep venous thrombosis: technical and clinical outcomes