Kyungmin Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kyungmin Lee has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Hyun Seung Lee
Department of Radiology Ajou University Medical Center Suwon Republic of Korea
2 shared publications - Jayoung Moon
Ajou University School of Medicine & Graduate School of Medicine, Ajou University Medical Center Department of Radiology 164 World cup-ro , Yeongtong-gu, Suwon, 16499
2 shared publications - Jimi Huh
Department of Radiology Ajou University Medical Center Suwon Republic of Korea
2 shared publications - Eun Ju Ha
Department of Radiology, Ajou University School of Medicine, Suwon, Korea
1 shared publication - Haein Lee
Department of Radiology, Ajou University School of Medicine , Wonchon-Dong, Yeongtong-Gu, Suwon 16499 , South Korea
1 shared publication - Ho Sung Park
Department of Radiology Ajou University Medical Center Suwon Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 31 August 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
Pre‐Scan Breathing Pattern and Image Quality in Respiratory‐Triggered T2 ‐Weighted Liver MRI : Radial Versus Cartesian Fast Spin Echo
Background: Respiratory‐triggered T2‐weighted imaging (T2WI) may use rectilinear sampling (respiratory‐triggered fast recovery fast spin echo [RT‐FRFSE]) or radial sampling (periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER]). Their relative performance across breathing patterns is unclear. Purpose: To compare image quality of PROPELLER and RT‐FRFSE according to pre‐scan breathing pattern. Study Type: Retrospective. Subjects: 200 patients undergoing liver MRI (124 males; mean age, 58.1 ± 13.3 years). Field Strength/Sequence: 1.5 T; fat‐suppressed T2WI using PROPELLER and RT‐FRFSE, both respiratory‐triggered. Assessment: Patients were stratified by pre‐scan respiratory rate and regularity: Group A (regular, ≤ 14 breaths/min, n = 49), B (15–17, n = 57), C (≥ 18, n = 49), D (irregular, n = 45). Three radiologists, blinded to respiratory group, graded ghost artifacts, sharpness, noise, and overall quality on five‐point scales. Liver signal‐to‐noise (SNR) and liver‐to‐gallbladder contrast‐to‐noise ratios (CNR) were measured. Statistical Tests: Wilcoxon signed‐rank test with Holm correction; Kruskal‐Wallis analysis of within‐patient difference scores and a linear mixed‐effects model for SNR/CNR interactions; quadratic weighted kappa and intraclass correlation coefficient for interobserver agreement. p < 0.05 indicated significance. Results: In Groups A and B, RT‐FRFSE scored higher qualitatively, except ghost artifacts in Group A ( p = 0.197). In Groups C and D, PROPELLER was superior (overall quality 3.96 vs. 3.41 and 3.93 vs. 3.01). Quantitatively (PROPELLER vs. RT‐FRFSE), median SNR was 79.2 vs. 95.6 (A) and 70.0 vs. 58.6 (C), and median CNR 57.6 vs. 64.4 (A) and 55.5 vs. 42.7 (D); SNR did not differ in Groups B ( p = 0.504) or D ( p = 0.480), and CNR did not differ in Groups B or C (both p = 1.000). Interobserver agreement was substantial to almost perfect (kappa: 0.64–0.83; ICC: 0.89–0.93). Data Conclusion: RT‐FRFSE performed better with slower, regular breathing and PROPELLER with faster or irregular breathing. Pre‐scan respiratory assessment may inform sequence selection. Evidence Level: 3. Technical Efficacy: Stage 1.
- 31 August 2026
- Published by Wiley in Journal of Magnetic Resonance Imaging
Open AccessPre‐Scan Breathing Pattern and Image Quality in Respiratory‐Triggered T2 ‐Weighted Liver MRI : Radial Versus Cartesian Fast Spin Echo
Background: Respiratory‐triggered T2‐weighted imaging (T2WI) may use rectilinear sampling (respiratory‐triggered fast recovery fast spin echo [RT‐FRFSE]) or radial sampling (periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER]). Their relative performance across breathing patterns is unclear. Purpose: To compare image quality of PROPELLER and RT‐FRFSE according to pre‐scan breathing pattern. Study Type: Retrospective. Subjects: 200 patients undergoing liver MRI (124 males; mean age, 58.1 ± 13.3 years). Field Strength/Sequence: 1.5 T; fat‐suppressed T2WI using PROPELLER and RT‐FRFSE, both respiratory‐triggered. Assessment: Patients were stratified by pre‐scan respiratory rate and regularity: Group A (regular, ≤ 14 breaths/min, n = 49), B (15–17, n = 57), C (≥ 18, n = 49), D (irregular, n = 45). Three radiologists, blinded to respiratory group, graded ghost artifacts, sharpness, noise, and overall quality on five‐point scales. Liver signal‐to‐noise (SNR) and liver‐to‐gallbladder contrast‐to‐noise ratios (CNR) were measured. Statistical Tests: Wilcoxon signed‐rank test with Holm correction; Kruskal‐Wallis analysis of within‐patient difference scores and a linear mixed‐effects model for SNR/CNR interactions; quadratic weighted kappa and intraclass correlation coefficient for interobserver agreement. p < 0.05 indicated significance. Results: In Groups A and B, RT‐FRFSE scored higher qualitatively, except ghost artifacts in Group A ( p = 0.197). In Groups C and D, PROPELLER was superior (overall quality 3.96 vs. 3.41 and 3.93 vs. 3.01). Quantitatively (PROPELLER vs. RT‐FRFSE), median SNR was 79.2 vs. 95.6 (A) and 70.0 vs. 58.6 (C), and median CNR 57.6 vs. 64.4 (A) and 55.5 vs. 42.7 (D); SNR did not differ in Groups B ( p = 0.504) or D ( p = 0.480), and CNR did not differ in Groups B or C (both p = 1.000). Interobserver agreement was substantial to almost perfect (kappa: 0.64–0.83; ICC: 0.89–0.93). Data Conclusion: RT‐FRFSE performed better with slower, regular breathing and PROPELLER with faster or irregular breathing. Pre‐scan respiratory assessment may inform sequence selection. Evidence Level: 3. Technical Efficacy: Stage 1.
- 5 May 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1183) , 1414-1421
Incidence of contrast-associated acute kidney injury in trauma patients undergoing contrast-enhanced computed tomography using iso-osmolar contrast media
Objective: This study aimed to evaluate the incidence and severity of contrast-associated acute kidney injury (CA-AKI), and its predictive factors in trauma patients. Methods: Trauma patients from the Regional Korea Trauma Center who underwent iodixanol-enhanced CT and were monitored for 72 hours post-scan were included. Demographics, comorbidities, and lab results were collected. CA-AKI was defined by the 2012 Kidney Disease: Improving Global Outcomes (KDIGO) guidelines. Severity of CA-AKI was classified by the risk, injury, failure, loss of kidney function, and end-stage renal failure (RIFLE) criteria. Trauma severity was assessed by the injury severity score (ISS) category. Predictive factors of CA-AKI were evaluated by univariate and multivariate logistic regression. Results: Of 1115 patients undergoing iodixanol-enhanced CT, 799 with complete data were included. Overall CA-AKI incidence was 3.80% (30/799), and severe renal failure occurred in 2.87% (23/799). CA-AKI incidence by ISS category was 1.52% (minor), 3.95% (moderate), 42.30% (serious), and 75.0% (severe). Upon univariate analysis, significant predictive factors of CA-AKI included hypertension [odds ratio (OR) 2.87], heart disease (OR 4.06), serious ISS (OR 47.50), and severe ISS (OR 194.33). Upon multivariate analysis, significant predictive factors were ISS serious category (OR 48.20), and ISS severe category (OR 245.22). Conclusions: In trauma patients who underwent iodixanol-enhanced CT, incidence of CA-AKI was considerably low at 3.8%, with trauma severity as a significant predictive factor. Advances in knowledge: Iodixanol-enhanced CT demonstrates low CA-AKI incidence and favorable safety in trauma patients. These findings support its clinical utility in high-trauma cases where renal risk is elevated.
- 5 May 2026
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 99 (1183) , 1414-1421
Incidence of contrast-associated acute kidney injury in trauma patients undergoing contrast-enhanced computed tomography using iso-osmolar contrast media
Objective: This study aimed to evaluate the incidence and severity of contrast-associated acute kidney injury (CA-AKI), and its predictive factors in trauma patients. Methods: Trauma patients from the Regional Korea Trauma Center who underwent iodixanol-enhanced CT and were monitored for 72 hours post-scan were included. Demographics, comorbidities, and lab results were collected. CA-AKI was defined by the 2012 Kidney Disease: Improving Global Outcomes (KDIGO) guidelines. Severity of CA-AKI was classified by the risk, injury, failure, loss of kidney function, and end-stage renal failure (RIFLE) criteria. Trauma severity was assessed by the injury severity score (ISS) category. Predictive factors of CA-AKI were evaluated by univariate and multivariate logistic regression. Results: Of 1115 patients undergoing iodixanol-enhanced CT, 799 with complete data were included. Overall CA-AKI incidence was 3.80% (30/799), and severe renal failure occurred in 2.87% (23/799). CA-AKI incidence by ISS category was 1.52% (minor), 3.95% (moderate), 42.30% (serious), and 75.0% (severe). Upon univariate analysis, significant predictive factors of CA-AKI included hypertension [odds ratio (OR) 2.87], heart disease (OR 4.06), serious ISS (OR 47.50), and severe ISS (OR 194.33). Upon multivariate analysis, significant predictive factors were ISS serious category (OR 48.20), and ISS severe category (OR 245.22). Conclusions: In trauma patients who underwent iodixanol-enhanced CT, incidence of CA-AKI was considerably low at 3.8%, with trauma severity as a significant predictive factor. Advances in knowledge: Iodixanol-enhanced CT demonstrates low CA-AKI incidence and favorable safety in trauma patients. These findings support its clinical utility in high-trauma cases where renal risk is elevated.
- Open Access
- 1 January 2023
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 84 (1) , 197-211
Bare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location
이경민, et al. J Korean Soc Radiol. 2023 Jan;84:e5. https://doi.org/10.3348/jksr.2022.0069
- 1 January 2023
- Published by XMLink in Journal of the Korean Society of Radiology
- Vol. 84 (1) , 197-211
Open AccessBare-Metal Stent in Dysfunctional Hemodialysis Access: An Assessment of Circuit Patency according to Access Type and Stent Location
이경민, et al. J Korean Soc Radiol. 2023 Jan;84:e5. https://doi.org/10.3348/jksr.2022.0069
- Open Access
- 1 July 2022
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 41 (3) , 473-479
Technical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
Purpose: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures.Methods: Six trainees and a staff radiologist performed TN-targeting punctures with or without the NGS in phantom models (group 1, experience <50 cases; group 2, experience ≥50 cases and <100 cases; group 3, experience ≥100 cases of TN-targeting punctures). The feasibility, technical success rate, number of punctures, and procedure time were recorded.Results: The feasibility of NGS was 98.6% (138/140). In group 1, the technical success rate increased from 60.0%±8.2% to 80.0%±8.2% when the NGS was used (P=0.046), with a reduction in the number of punctures from 2.2 to 1.2 (P=0.005). In group 2, the rate changed from 95.0%±5.8% to 100.0%±0.0% with the NGS (P=0.157), with a minimal decrease in the number of punctures from 1.1 to 1.0 (P=0.157). The procedure time significantly decreased in both groups (P=0.041 and P=0.010, respectively) when the NGS was used. In group 3, there were no significant differences in the technical success rate and the number of punctures according to whether the NGS was used (P=0.317 and P=0.317, respectively).Conclusion: NGS using standard needle magnetization is technically feasible and has potential to improve the efficacy of TN-targeting punctures for less-experienced operators, especially beginners, according to the findings of this phantom study.
- 1 July 2022
- Published by Korean Society of Ultrasound in Medicine in Ultrasonography
- Vol. 41 (3) , 473-479
Open AccessTechnical feasibility and efficacy of a standard needle magnetization system for ultrasound needle guidance in thyroid nodule-targeting punctures: a phantom study
Purpose: The aim of this study was to assess the feasibility and efficacy of an ultrasound needle guidance system (NGS) based on standard needle magnetization in a phantom study of thyroid nodule (TN)-targeting punctures.Methods: Six trainees and a staff radiologist performed TN-targeting punctures with or without the NGS in phantom models (group 1, experience <50 cases; group 2, experience ≥50 cases and <100 cases; group 3, experience ≥100 cases of TN-targeting punctures). The feasibility, technical success rate, number of punctures, and procedure time were recorded.Results: The feasibility of NGS was 98.6% (138/140). In group 1, the technical success rate increased from 60.0%±8.2% to 80.0%±8.2% when the NGS was used (P=0.046), with a reduction in the number of punctures from 2.2 to 1.2 (P=0.005). In group 2, the rate changed from 95.0%±5.8% to 100.0%±0.0% with the NGS (P=0.157), with a minimal decrease in the number of punctures from 1.1 to 1.0 (P=0.157). The procedure time significantly decreased in both groups (P=0.041 and P=0.010, respectively) when the NGS was used. In group 3, there were no significant differences in the technical success rate and the number of punctures according to whether the NGS was used (P=0.317 and P=0.317, respectively).Conclusion: NGS using standard needle magnetization is technically feasible and has potential to improve the efficacy of TN-targeting punctures for less-experienced operators, especially beginners, according to the findings of this phantom study.