Pre‐Scan Breathing Pattern and Image Quality in Respiratory‐Triggered T2 ‐Weighted Liver MRI : Radial Versus Cartesian Fast Spin Echo
Open Access
- 31 August 2026
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
Abstract
Background: Respiratory‐triggered T2‐weighted imaging (T2WI) may use rectilinear sampling (respiratory‐triggered fast recovery fast spin echo [RT‐FRFSE]) or radial sampling (periodically rotated overlapping parallel lines with enhanced reconstruction [PROPELLER]). Their relative performance across breathing patterns is unclear. Purpose: To compare image quality of PROPELLER and RT‐FRFSE according to pre‐scan breathing pattern. Study Type: Retrospective. Subjects: 200 patients undergoing liver MRI (124 males; mean age, 58.1 ± 13.3 years). Field Strength/Sequence: 1.5 T; fat‐suppressed T2WI using PROPELLER and RT‐FRFSE, both respiratory‐triggered. Assessment: Patients were stratified by pre‐scan respiratory rate and regularity: Group A (regular, ≤ 14 breaths/min, n = 49), B (15–17, n = 57), C (≥ 18, n = 49), D (irregular, n = 45). Three radiologists, blinded to respiratory group, graded ghost artifacts, sharpness, noise, and overall quality on five‐point scales. Liver signal‐to‐noise (SNR) and liver‐to‐gallbladder contrast‐to‐noise ratios (CNR) were measured. Statistical Tests: Wilcoxon signed‐rank test with Holm correction; Kruskal‐Wallis analysis of within‐patient difference scores and a linear mixed‐effects model for SNR/CNR interactions; quadratic weighted kappa and intraclass correlation coefficient for interobserver agreement. p < 0.05 indicated significance. Results: In Groups A and B, RT‐FRFSE scored higher qualitatively, except ghost artifacts in Group A ( p = 0.197). In Groups C and D, PROPELLER was superior (overall quality 3.96 vs. 3.41 and 3.93 vs. 3.01). Quantitatively (PROPELLER vs. RT‐FRFSE), median SNR was 79.2 vs. 95.6 (A) and 70.0 vs. 58.6 (C), and median CNR 57.6 vs. 64.4 (A) and 55.5 vs. 42.7 (D); SNR did not differ in Groups B ( p = 0.504) or D ( p = 0.480), and CNR did not differ in Groups B or C (both p = 1.000). Interobserver agreement was substantial to almost perfect (kappa: 0.64–0.83; ICC: 0.89–0.93). Data Conclusion: RT‐FRFSE performed better with slower, regular breathing and PROPELLER with faster or irregular breathing. Pre‐scan respiratory assessment may inform sequence selection. Evidence Level: 3. Technical Efficacy: Stage 1.Keywords
Funding Information
- Ministry of Science and ICT, South Korea (RS‐2025‐02219599)
This publication has 15 references indexed in Scilit:
- Free‐breathing unsedated MRI in children: Justification and techniquesJournal of Magnetic Resonance Imaging, 2019
- Motion artifacts in MRI: A complex problem with many partial solutionsJournal of Magnetic Resonance Imaging, 2015
- Image quality of T2w-TSE of the abdomen and pelvis with Cartesian or BLADE-type k-space sampling: A retrospective interindividual comparison studyEuropean Journal of Radiology, 2011
- Breath-hold T2-weighted MRI of the liver at 3T using the BLADE technique: impact upon image quality and lesion detectionClinical Radiology, 2011
- Usefulness of the application of the BLADE technique to reduce motion artifacts on navigation‐triggered prospective acquisition correction (PACE) T2‐weighted MRI (T2WI) of the liverJournal of Magnetic Resonance Imaging, 2009
- Evaluation of motion correction effect and image quality with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) (BLADE) and parallel imaging acquisition technique in the upper abdomenJournal of Magnetic Resonance Imaging, 2008
- Image quality and focal lesion detection on T2‐weighted MR imaging of the liver: Comparison of two high‐resolution free‐breathing imaging techniques with two breath‐hold imaging techniquesJournal of Magnetic Resonance Imaging, 2007
- T2‐weighted MRI of rectosigmoid carcinoma: Comparison of respiratory‐triggered fast spin‐echo, breathhold fast‐recovery fast spin‐echo, and breathhold single‐shot fast spin‐echo sequencesJournal of Magnetic Resonance Imaging, 2007
- Fat‐suppressed T2‐weighted MRI of the liver: Comparison of respiratory‐triggered fast spin‐echo, breath‐hold single‐shot fast spin‐echo, and breath‐hold fast‐recovery fast spin‐echo sequencesJournal of Magnetic Resonance Imaging, 2001
- Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imagingMagnetic Resonance in Medicine, 1999