Rajesh Kumar Patnaik
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Rajesh Kumar Patnaik has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- A. Arulmozhi
Department of Physics, St. Joseph’s College of Engineering, OMR, Chennai 600119, Tamil Nadu, India
1 shared publication - Amara S. A. L. G. Gopala Gupta
Koneru Lakshmaiah Education Foundation, Vaddeswaram, India
1 shared publication Ashish Ranjan Dash
Department of EEE, Centurion University of Technology and Management, Paralakhemundi, India
1 shared publication- Bipin Kumar Srivastava
Department of Applied Sciences and Humanities, Galgotias College of Engineering & Technology, Greater Noida 201310, Uttar Pradesh, India
1 shared publication - Ch. Venkateswara Rao
Gandhi Institute of Engineering and Technology University
1 shared publication - D. V. S. S. S. V. Prasad
Department of Mechanical Engineering, Aditya College of Engineering (A), Surampalem 533437, Andhra Pradesh, India
1 shared publication
Latest Publications
- 17 June 2025
- Published by Springer Nature
- p. 391-404
Detailed View of Fault Analysis with Signal Energy Operator Method to a DFIG-Based Micro Grid System
- 17 June 2025
- Published by Springer Nature
- p. 391-404
Detailed View of Fault Analysis with Signal Energy Operator Method to a DFIG-Based Micro Grid System
- 21 October 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 33 (07)
METAL-SUPPORTED SOLID OXIDE FUEL CELLS: SYNTHESIS AND ELECTROCHEMICAL PROPERTIES ANALYSIS USING OPTIMIZATION METHOD
Recently, metal-supported solid oxide fuel cells (MS–SOFCs) have been in the spotlight again for their design, thanks to their inexpensive materials, robustness, resistance to thermal cycling, and benefits of manufacturability. Hydrogen energy electrochemical devices, like MS–SOFCs, have a lot of potential. They are very ideal substitutes for solid oxide fuel cells (SOFCs) that utilize electrolytes or ceramic electrodes as their carrier basis, because of their greater durability, mechanical stability, heat cycle resistance, and rapid startup time. Even though MS–SOFCs have several advantages over conventional ceramic-based SOFCs, researchers are still struggling to perfect them due to issues such as selecting the appropriate metal-based material for the electrodes (anode, electrode) and comprehending how they deteriorate. This limitation might be evaded by optimizing the pore former filling and the diameter of the metallic supports (130–250[ ][ ]m). Optimization methods, such as particle swarm optimization, as well as penetration cycle numbers (1–15), as well as the impacts of fire temperatures (400–900 ∘ C), were investigated to aid in optimizing the catalyst infiltration procedure. The enhanced cell outperformed its original performance by a factor of three, reaching an ideal energy density of 0.9[ ]W cm[ ] at 700 ∘ C when powered by hydrogen. The improved cells had a 2% degradation rate per 100[ ]h at 550 ∘ C, a 4.5% degradation rate at 600 ∘ C, and a 5.5% degradation rate at 700 ∘ C. We used electrochemical impedance spectroscopy and scanning electron microscopy to look at the catalyst’s mass shipping, coarsening, and chromium poisoning.
- 21 October 2024
- Published by World Scientific Pub Co Pte Ltd in Surface Review and Letters
- Vol. 33 (07)
METAL-SUPPORTED SOLID OXIDE FUEL CELLS: SYNTHESIS AND ELECTROCHEMICAL PROPERTIES ANALYSIS USING OPTIMIZATION METHOD
Recently, metal-supported solid oxide fuel cells (MS–SOFCs) have been in the spotlight again for their design, thanks to their inexpensive materials, robustness, resistance to thermal cycling, and benefits of manufacturability. Hydrogen energy electrochemical devices, like MS–SOFCs, have a lot of potential. They are very ideal substitutes for solid oxide fuel cells (SOFCs) that utilize electrolytes or ceramic electrodes as their carrier basis, because of their greater durability, mechanical stability, heat cycle resistance, and rapid startup time. Even though MS–SOFCs have several advantages over conventional ceramic-based SOFCs, researchers are still struggling to perfect them due to issues such as selecting the appropriate metal-based material for the electrodes (anode, electrode) and comprehending how they deteriorate. This limitation might be evaded by optimizing the pore former filling and the diameter of the metallic supports (130–250[ ][ ]m). Optimization methods, such as particle swarm optimization, as well as penetration cycle numbers (1–15), as well as the impacts of fire temperatures (400–900 ∘ C), were investigated to aid in optimizing the catalyst infiltration procedure. The enhanced cell outperformed its original performance by a factor of three, reaching an ideal energy density of 0.9[ ]W cm[ ] at 700 ∘ C when powered by hydrogen. The improved cells had a 2% degradation rate per 100[ ]h at 550 ∘ C, a 4.5% degradation rate at 600 ∘ C, and a 5.5% degradation rate at 700 ∘ C. We used electrochemical impedance spectroscopy and scanning electron microscopy to look at the catalyst’s mass shipping, coarsening, and chromium poisoning.
- 1 October 2023
- Published by Edtech Publishers (OPC) Private Limited in International Journal of Scientific Research in Engineering and Management
- Vol. 07 (10) , 1-11
A STUDY OF PERFORMANCE OF DFIG BASED MICROGRID SUBJECTED TO DISTURBANCES
A STUDY OF PERFORMANCE OF DFIG BASED MICROGRID SUBJECTED TO DISTURBANCES Dr. Rajesh Kumar Patnaik1*, S. Pavan Kumar2, P. Chatrapathi2, […]
- 1 October 2023
- Published by Edtech Publishers (OPC) Private Limited in International Journal of Scientific Research in Engineering and Management
- Vol. 07 (10) , 1-11
A STUDY OF PERFORMANCE OF DFIG BASED MICROGRID SUBJECTED TO DISTURBANCES
A STUDY OF PERFORMANCE OF DFIG BASED MICROGRID SUBJECTED TO DISTURBANCES Dr. Rajesh Kumar Patnaik1*, S. Pavan Kumar2, P. Chatrapathi2, […]
- Open Access
- 1 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 7 (1) , 1-19
A simple decision tree-based disturbance monitoring system for VSC-based HVDC transmission link integrating a DFIG wind farm
Fault detection and classification is a key challenge for the protection of High Voltage DC (HVDC) transmission lines. In this paper, the Teager–Kaiser Energy Operator (TKEO) algorithm associated with a decision tree-based fault classifier is proposed to detect and classify various DC faults. The Change Identification Filter is applied to the average and differential current components, to detect the first instant of fault occurrence (above threshold) and register a Change Identified Point (CIP). Further, if a CIP is registered for a positive or negative line, only three samples of currents (i.e., CIP and each side of CIP) are sent to the proposed TKEO algorithm, which produces their respective 8 indices through which the, fault can be detected along with its classification. The new approach enables quicker detection allowing utility grids to be restored as soon as possible. This novel approach also reduces computing complexity and the time required to identify faults with classification. The importance and accuracy of the proposed scheme are also thoroughly tested and compared with other methods for various faults on HVDC transmission lines.
- 1 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in Protection and Control of Modern Power Systems
- Vol. 7 (1) , 1-19
Open AccessA simple decision tree-based disturbance monitoring system for VSC-based HVDC transmission link integrating a DFIG wind farm
Fault detection and classification is a key challenge for the protection of High Voltage DC (HVDC) transmission lines. In this paper, the Teager–Kaiser Energy Operator (TKEO) algorithm associated with a decision tree-based fault classifier is proposed to detect and classify various DC faults. The Change Identification Filter is applied to the average and differential current components, to detect the first instant of fault occurrence (above threshold) and register a Change Identified Point (CIP). Further, if a CIP is registered for a positive or negative line, only three samples of currents (i.e., CIP and each side of CIP) are sent to the proposed TKEO algorithm, which produces their respective 8 indices through which the, fault can be detected along with its classification. The new approach enables quicker detection allowing utility grids to be restored as soon as possible. This novel approach also reduces computing complexity and the time required to identify faults with classification. The importance and accuracy of the proposed scheme are also thoroughly tested and compared with other methods for various faults on HVDC transmission lines.