Saikrishna Kanukollu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Saikrishna Kanukollu has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Al-Durra
Khalifa University
8 shared publications - Saleh A. Saleh
University of New Brunswick, Fredericton, NB, Canada
4 shared publications - Danielle Jewett
Department of Electrical and Computer Engineering, University of New Brunswick, Fredericton, NB, Canada
2 shared publications - Fei Gao
University of Technology of Belfort-Montbéliard
2 shared publications - Julian Luciano Cardenas-Barrera
Department of Electrical and Computer Engineering, University of New Brunswick, Fredericton, Canada
2 shared publications - Marcelo E. Valdes
ABB, Chapel Hill, NC, USA
2 shared publications
Latest Publications
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (3) , 2047-2063
Decentralized Cost-Based Dispatchable Virtual Oscillator Control for Grid-Forming Inverters
Decentralized power sharing among inverter-based distributed generators is a key pillar for maintaining stability and minimizing operational costs in islanded microgrids (MGs). Indeed, ensuring decentralized economic dispatch through cost-based droop control is common practice; however, it lacks inertial response, leading to significant frequency deviation and a high rate of frequency change during disturbances. This paper introduces an optimal sophisticated control algorithm based on an enhanced dispatchable virtual oscillator control (dVOC) framework for grid-forming (GFM) inverters. The proposed controller supports fully decentralized dispatch under nonlinear cost functions. Moreover, it incorporates negative derivative feedback into the outer loop, introducing an additional degree of freedom to improve overall stability by shifting the most dominant modes deeper into the left-hand side of the $j\omega $ axis. Hence, with this aim, it acts as an optimal cost-driven dispatch controller during steady-state and transitions to a stabilizing inertia-emulating mode during disturbances, reducing frequency excursions and improving overall system stability. The proposed approach is evaluated through small-signal sensitivity analysis and detailed time-domain simulations, performed using MATLAB/Simulink. Furthermore, the proposed approach is validated experimentally and on a modified IEEE 38-bus system, which represents a scenario with a larger number of GFMs. Consequently, results demonstrate improved frequency regulation, robust performance under non-ideal conditions, and enhanced small-signal stability compared to conventional GFM control methods.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Smart Grid
- Vol. 17 (3) , 2047-2063
Decentralized Cost-Based Dispatchable Virtual Oscillator Control for Grid-Forming Inverters
Decentralized power sharing among inverter-based distributed generators is a key pillar for maintaining stability and minimizing operational costs in islanded microgrids (MGs). Indeed, ensuring decentralized economic dispatch through cost-based droop control is common practice; however, it lacks inertial response, leading to significant frequency deviation and a high rate of frequency change during disturbances. This paper introduces an optimal sophisticated control algorithm based on an enhanced dispatchable virtual oscillator control (dVOC) framework for grid-forming (GFM) inverters. The proposed controller supports fully decentralized dispatch under nonlinear cost functions. Moreover, it incorporates negative derivative feedback into the outer loop, introducing an additional degree of freedom to improve overall stability by shifting the most dominant modes deeper into the left-hand side of the $j\omega $ axis. Hence, with this aim, it acts as an optimal cost-driven dispatch controller during steady-state and transitions to a stabilizing inertia-emulating mode during disturbances, reducing frequency excursions and improving overall system stability. The proposed approach is evaluated through small-signal sensitivity analysis and detailed time-domain simulations, performed using MATLAB/Simulink. Furthermore, the proposed approach is validated experimentally and on a modified IEEE 38-bus system, which represents a scenario with a larger number of GFMs. Consequently, results demonstrate improved frequency regulation, robust performance under non-ideal conditions, and enhanced small-signal stability compared to conventional GFM control methods.
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3588-3603
Enhanced Grid-Forming Operation of Virtual Synchronous Generator Units
Virtual synchronous generator (VSG) control, incorporating frequency and voltage droop mechanisms, is a promising grid-forming (GFM) technology that emulates conventional generators by providing virtual inertia, frequency regulation, and damping. However, transient stability analysis typically omits the influence of inner current control (ICC) and voltage control (VC), potentially resulting in an inaccurate assessment. This paper investigates the influence of considering the VC and ICC and the current reference angle on VSG transient stability. Integrating VC and ICC into VSG stability studies yields more accurate results but reduces the VSG domain of stability (DoS). In order to address these aspects, this paper proposes a sophisticated approach, namely combined feedback-feedforward-VSG (FB-FF-VSG) control, which incorporates the standard VSG with additional feedback into the outer loop and feedforward in the ICC in order to enhance transient stability and allow fault ride-through (FRT) by expanding the DoS. Additionally, an enlarged DoS promotes stability across a broader range of initial conditions. Numerical simulations show that the proposed control has better performance with respect to traditional VSG and virtual oscillator control (VOC) in terms of adaptability, stability, and flexibility across a spectrum of disturbances, including three-phase faults and load variations, marked by a substantial improvement in the DoS and accelerated dynamic response. The proposed approach is further validated by implementing the controller in a lab-scale microgrid.
- 6 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3588-3603
Enhanced Grid-Forming Operation of Virtual Synchronous Generator Units
Virtual synchronous generator (VSG) control, incorporating frequency and voltage droop mechanisms, is a promising grid-forming (GFM) technology that emulates conventional generators by providing virtual inertia, frequency regulation, and damping. However, transient stability analysis typically omits the influence of inner current control (ICC) and voltage control (VC), potentially resulting in an inaccurate assessment. This paper investigates the influence of considering the VC and ICC and the current reference angle on VSG transient stability. Integrating VC and ICC into VSG stability studies yields more accurate results but reduces the VSG domain of stability (DoS). In order to address these aspects, this paper proposes a sophisticated approach, namely combined feedback-feedforward-VSG (FB-FF-VSG) control, which incorporates the standard VSG with additional feedback into the outer loop and feedforward in the ICC in order to enhance transient stability and allow fault ride-through (FRT) by expanding the DoS. Additionally, an enlarged DoS promotes stability across a broader range of initial conditions. Numerical simulations show that the proposed control has better performance with respect to traditional VSG and virtual oscillator control (VOC) in terms of adaptability, stability, and flexibility across a spectrum of disturbances, including three-phase faults and load variations, marked by a substantial improvement in the DoS and accelerated dynamic response. The proposed approach is further validated by implementing the controller in a lab-scale microgrid.
- Open Access
- 17 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (7) , 9427-9444
Enhancing Dynamic Performance of Islanded Microgrids by Fractional-Order Derivative Droop
Islanded operation of microgrids (MGs) with parallel-operated inverters imposes many control challenges in terms of stability and dynamic behavior, especially at contingency events. Hence, improving the dynamic performance and the stability margin is essential for robust MG operation. Therefore, the fractional-order derivative (FOD) droop controller is proposed to achieve these goals. A detailed small signal model is developed for the entire MG with the proposed controller and then used to assess the stability of the MG. The FOD and the integer-order derivative (IOD) droop controllers are applied to a benchmark MG and tuned via an optimization procedure under multiple loading conditions. The results show that the extra degrees of freedom introduced by the FOD droop facilitate pushing the dominant modes toward the required stability region. The proposed FOD droop is compared to the IOD droop, conventional droop, VOC, and virtual synchronous generator controllers under several contingency events and a reconfiguration scenario using MATLAB/SIMULINK, where the proposed controller shows superior performance. The experimental validations demonstrate the improved power-sharing performance of the proposed FOD droop controller.
- 17 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Informatics
- Vol. 20 (7) , 9427-9444
Open AccessEnhancing Dynamic Performance of Islanded Microgrids by Fractional-Order Derivative Droop
Islanded operation of microgrids (MGs) with parallel-operated inverters imposes many control challenges in terms of stability and dynamic behavior, especially at contingency events. Hence, improving the dynamic performance and the stability margin is essential for robust MG operation. Therefore, the fractional-order derivative (FOD) droop controller is proposed to achieve these goals. A detailed small signal model is developed for the entire MG with the proposed controller and then used to assess the stability of the MG. The FOD and the integer-order derivative (IOD) droop controllers are applied to a benchmark MG and tuned via an optimization procedure under multiple loading conditions. The results show that the extra degrees of freedom introduced by the FOD droop facilitate pushing the dominant modes toward the required stability region. The proposed FOD droop is compared to the IOD droop, conventional droop, VOC, and virtual synchronous generator controllers under several contingency events and a reconfiguration scenario using MATLAB/SIMULINK, where the proposed controller shows superior performance. The experimental validations demonstrate the improved power-sharing performance of the proposed FOD droop controller.
- 15 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5398-5410
Phaselet Transform-Based Digital Ground Fault Protection of Grid-Connected Photovoltaic Systems
The growing interests in utilizing Photovoltaic (PV) systems are usually faced with challenges of accurate and reliable protection of these distributed generation units. A desired protection of PV systems has to effectively and accurately detect and respond to internal faults (within the PV system) and external faults (in the host grid and/or fed loads). This paper presents and tests the performance of a digital ground fault protection (DGFP) for grid-connected PV systems. The presented DGFP detects faults based on the energy contents of high frequency sub-bands of the ground current. These energy contents are extracted using the phaselet transform that can process signals with non-stationary variations in their phases. Energy contents of the high frequency sub-bands can provide accurate, fast, and reliable detection and identification of faults experienced by a PV system operated. The phaselet transform (PHT)-based DGFP is implemented for performance testing using PV systems that are operated in the grid-connected mode, and subjected to various fault and non-fault events. Performance results demonstrate accurate, fast, and reliable detection and response to different types of fault and non-fault events. Response features of the PHT-based DGFP are complimented with minor sensitivity to the level of power production and/or type and location of faults.
- 15 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5398-5410
Phaselet Transform-Based Digital Ground Fault Protection of Grid-Connected Photovoltaic Systems
The growing interests in utilizing Photovoltaic (PV) systems are usually faced with challenges of accurate and reliable protection of these distributed generation units. A desired protection of PV systems has to effectively and accurately detect and respond to internal faults (within the PV system) and external faults (in the host grid and/or fed loads). This paper presents and tests the performance of a digital ground fault protection (DGFP) for grid-connected PV systems. The presented DGFP detects faults based on the energy contents of high frequency sub-bands of the ground current. These energy contents are extracted using the phaselet transform that can process signals with non-stationary variations in their phases. Energy contents of the high frequency sub-bands can provide accurate, fast, and reliable detection and identification of faults experienced by a PV system operated. The phaselet transform (PHT)-based DGFP is implemented for performance testing using PV systems that are operated in the grid-connected mode, and subjected to various fault and non-fault events. Performance results demonstrate accurate, fast, and reliable detection and response to different types of fault and non-fault events. Response features of the PHT-based DGFP are complimented with minor sensitivity to the level of power production and/or type and location of faults.
- Open Access
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 3706-3716
Selective Harmonic Elimination in a Multilevel Inverter Using Multi-Criteria Search Enhanced Firefly Algorithm
This research paper proposes the new multi-criteria search based enhanced firefly algorithm for solving selective harmonic elimination in a multilevel inverter. This new enhanced firefly utilizes adaptive nature of social and cognitive components to find the global optima. To see the effectiveness of the proposed algorithm and for the evaluation of results, a three phase nine level cascaded multilevel inverter (CHBMLI) is used. It is compared with existing meta-heuristic algorithms namely particle swarm optimization and firefly algorithm to validate its effectiveness. Crucial parameters for optimization, including population size and number of iterations, are kept same for comparison. For comparison, total harmonic distortion (THD) and convergence behaviour of algorithms against various modulation index values are considered. Moreover, results have clearly indicated that the proposed algorithm has surpassed PSO and FA in terms of convergence behaviour by attaining lower fitness value in lesser number of iterations. Finally, the experimental validation of selective harmonic elimination in multi-level inverter is also performed and analyzed.
- 9 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 3706-3716
Open AccessSelective Harmonic Elimination in a Multilevel Inverter Using Multi-Criteria Search Enhanced Firefly Algorithm
This research paper proposes the new multi-criteria search based enhanced firefly algorithm for solving selective harmonic elimination in a multilevel inverter. This new enhanced firefly utilizes adaptive nature of social and cognitive components to find the global optima. To see the effectiveness of the proposed algorithm and for the evaluation of results, a three phase nine level cascaded multilevel inverter (CHBMLI) is used. It is compared with existing meta-heuristic algorithms namely particle swarm optimization and firefly algorithm to validate its effectiveness. Crucial parameters for optimization, including population size and number of iterations, are kept same for comparison. For comparison, total harmonic distortion (THD) and convergence behaviour of algorithms against various modulation index values are considered. Moreover, results have clearly indicated that the proposed algorithm has surpassed PSO and FA in terms of convergence behaviour by attaining lower fitness value in lesser number of iterations. Finally, the experimental validation of selective harmonic elimination in multi-level inverter is also performed and analyzed.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (2) , 1138-1147
Performance Assessment of Frequency Selective Grounding for Grid-Connected Photovoltaic Systems
Photovoltaic (PV) panels and their grid-connection circuitries have to be grounded to comply with various standards and industrial codes. Objectives of grounding a PV system include limiting ground currents and potentials, supporting the operation of protective devices therein, and preventing the accumulation of static charges on PV panels. These objectives can be translated into design constraints for an impedance to connect a PV system to the ground. This paper presents the design and performance assessment of a frequency selective grounding (FSGR) for grid-connected PV systems. The proposed FSGR is composed of a parallel $R$ , $L$ , and $C$ circuit, which provides a resistive path for dc currents and a low capacitive impedance path for harmonic currents. The FSGR is designed and experimentally tested for a 2 kW, $3\phi$ , laboratory grid-connected PV system under fault and non-fault conditions. The performance of the proposed grounding is also compared with the solid grounding under similar conditions to further assess its capabilities. Experimental results show that the FSGR can reduce ground currents, limit ground potentials, and reduce the dc leakage currents. These observed features are complimented with minor effects on the operation of protective devices in a grid connected PV system.
- 26 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (2) , 1138-1147
Performance Assessment of Frequency Selective Grounding for Grid-Connected Photovoltaic Systems
Photovoltaic (PV) panels and their grid-connection circuitries have to be grounded to comply with various standards and industrial codes. Objectives of grounding a PV system include limiting ground currents and potentials, supporting the operation of protective devices therein, and preventing the accumulation of static charges on PV panels. These objectives can be translated into design constraints for an impedance to connect a PV system to the ground. This paper presents the design and performance assessment of a frequency selective grounding (FSGR) for grid-connected PV systems. The proposed FSGR is composed of a parallel $R$ , $L$ , and $C$ circuit, which provides a resistive path for dc currents and a low capacitive impedance path for harmonic currents. The FSGR is designed and experimentally tested for a 2 kW, $3\phi$ , laboratory grid-connected PV system under fault and non-fault conditions. The performance of the proposed grounding is also compared with the solid grounding under similar conditions to further assess its capabilities. Experimental results show that the FSGR can reduce ground currents, limit ground potentials, and reduce the dc leakage currents. These observed features are complimented with minor effects on the operation of protective devices in a grid connected PV system.
- 13 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 6002-6013
Evaluating the Impacts of Grounding Systems on Ground Currents and Transient Overvoltage
This article presents a performance comparison of the solid, low impedance, high impedance, frequency-selective, and isolated grounding systems. A grounding system (for any power system component) is designed as an impedance ( $\bar{Z}_{G}$ ) that connects the neutral point to the ground. The impedance $\bar{Z}_{G}$ is constructed using a combination of $R$ , $L$ , and $C$ elements. The values and combination type (series or parallel) of $R$ , $L$ , and $C$ determine the possible influence of $\bar{Z}_{G}$ on ground currents and potentials. Each grounding system is related to a system voltages level, a specific combination of $R$ , $L$ , and $C$ , and a range of $R$ , $L$ , and $C$ values. The solid, low impedance, high impedance, frequency-selective, and isolated grounding systems are designed for a $3\phi$ transformer and a $3\phi$ synchronous generator in order to compare their influences on ground currents and potentials during ground faults. The transformer and generator are tested for line-to-ground and double line-to-ground faults with all designed grounding systems. Test results show that some grounding systems can reduce ground currents only, while others can reduce ground potentials only. Such capabilities can be used to fulfill certain system and operation requirements (e.g., service continuity, ground capacity, etc.).
- 13 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 6002-6013
Evaluating the Impacts of Grounding Systems on Ground Currents and Transient Overvoltage
This article presents a performance comparison of the solid, low impedance, high impedance, frequency-selective, and isolated grounding systems. A grounding system (for any power system component) is designed as an impedance ( $\bar{Z}_{G}$ ) that connects the neutral point to the ground. The impedance $\bar{Z}_{G}$ is constructed using a combination of $R$ , $L$ , and $C$ elements. The values and combination type (series or parallel) of $R$ , $L$ , and $C$ determine the possible influence of $\bar{Z}_{G}$ on ground currents and potentials. Each grounding system is related to a system voltages level, a specific combination of $R$ , $L$ , and $C$ , and a range of $R$ , $L$ , and $C$ values. The solid, low impedance, high impedance, frequency-selective, and isolated grounding systems are designed for a $3\phi$ transformer and a $3\phi$ synchronous generator in order to compare their influences on ground currents and potentials during ground faults. The transformer and generator are tested for line-to-ground and double line-to-ground faults with all designed grounding systems. Test results show that some grounding systems can reduce ground currents only, while others can reduce ground potentials only. Such capabilities can be used to fulfill certain system and operation requirements (e.g., service continuity, ground capacity, etc.).
- 11 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 5987-6001
Experimental Assessment of Grounding System Impacts on Ground Currents and Transient Overvoltage
In this article, experimental performance assessment and comparison are presented for solid, low impedance, high impedance, frequency-selective, and isolated grounding (IG) systems. The typical design of a grounding system (for low and medium voltage generation, transmission, and distribution systems) is based on selecting an impedance ( $\bar{Z}_{G}$ ), which is used to connect the neutral point and the ground. The impedance $\bar{Z}_{G}$ is typically composed from a combination of $R$ , $L$ , and $C$ elements. The combination type (series or parallel), along with the values of $R$ , $L$ , $C$ elements, allow estimating the possible effects of $\bar{Z}_{G}$ on ground currents and potentials during ground faults. In this article, solid, low impedance, high impedance, frequency-selective, and IG systems are designed for a 35-kVA $3\phi$ transformer and a 5-kVA $3\phi$ synchronous generator, for purposes of assessing and comparing their effects on ground currents and potentials during ground faults. The laboratory transformer and generator are tested for line-to-ground and double line-to-ground faults with all designed grounding systems under different loading levels. Experimental results show that some grounding systems can effectively reduce ground currents, and other grounding systems can effectively reduce ground potentials. These capabilities and features can be used to achieve certain system and operation mandates, including ground capacity, maximum allowed overvoltage, and service continuity.
- 11 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 58 (5) , 5987-6001
Experimental Assessment of Grounding System Impacts on Ground Currents and Transient Overvoltage
In this article, experimental performance assessment and comparison are presented for solid, low impedance, high impedance, frequency-selective, and isolated grounding (IG) systems. The typical design of a grounding system (for low and medium voltage generation, transmission, and distribution systems) is based on selecting an impedance ( $\bar{Z}_{G}$ ), which is used to connect the neutral point and the ground. The impedance $\bar{Z}_{G}$ is typically composed from a combination of $R$ , $L$ , and $C$ elements. The combination type (series or parallel), along with the values of $R$ , $L$ , $C$ elements, allow estimating the possible effects of $\bar{Z}_{G}$ on ground currents and potentials during ground faults. In this article, solid, low impedance, high impedance, frequency-selective, and IG systems are designed for a 35-kVA $3\phi$ transformer and a 5-kVA $3\phi$ synchronous generator, for purposes of assessing and comparing their effects on ground currents and potentials during ground faults. The laboratory transformer and generator are tested for line-to-ground and double line-to-ground faults with all designed grounding systems under different loading levels. Experimental results show that some grounding systems can effectively reduce ground currents, and other grounding systems can effectively reduce ground potentials. These capabilities and features can be used to achieve certain system and operation mandates, including ground capacity, maximum allowed overvoltage, and service continuity.