Marcelo E. Valdes
Research Subjects
Marcelo E. Valdes has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Saleh A. Saleh
University of New Brunswick, Fredericton, NB, Canada
13 shared publications - Ahmed Al-Durra
Department of Electrical Engineering, Advanced Power and Energy Center, Khalifa University, Abu Dhabi, UAE
8 shared publications - Julian Meng
University of New Brunswick
7 shared publications - Danielle Jewett
Department of Electrical and Computer Engineering, University of New Brunswick, Fredericton, NB, Canada
6 shared publications - Emre Ozkop
Department of Electrical and Electronics Engineering, Karadeniz Technical University, Trabzon, Trkiye
6 shared publications - Sergio A. R. Panetta
Department of Engineering, I-Gard Corp., Mississauga, ON, Canada
6 shared publications
Latest Publications
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 6790-6797
Complying With NFPA 70B and Minimizing the Total Cost of Ownership of Medium Voltage Switchgear Using Condition Monitoring Technologies and Data Analytics
The NFPA 70B Standard for Electrical Equipment Maintenance requires that electrical equipment shall be maintained in accordance with the manufacturer's instructions and applicable codes and standards (NFPA 70B 4.1.1), and that the equipment owner shall implement an overall electrical maintenance program (EMP) as per NFPA 70B 4.2.1. Medium voltage (MV) distribution equipment can operate safely for many years and remain in good condition if installed in appropriate environments and properly maintained. Most organizations, even today, resort to the maintenance strategies of fix upon failure or a time- or usage-based maintenance program, and this is reflected in their EMP. However, advances in sensor technologies coupled with the dramatic growth in the information infrastructure of Internet of Things (IoT) and data analytics capabilities has opened new possibilities to rethink equipment maintenance based upon continuous monitoring of the equipment health. Such monitoring brings benefits of reduced operational costs through predictive maintenance and reduced downtime. An additional important potential benefit is an increase in personnel safety and reliability due to reduced need for onsite service and human interaction with energized equipment. In this paper we show how condition monitoring and data analytics technologies can reduce the total cost of ownership while complying with NFPA 70B.
- 20 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (4) , 6790-6797
Complying With NFPA 70B and Minimizing the Total Cost of Ownership of Medium Voltage Switchgear Using Condition Monitoring Technologies and Data Analytics
The NFPA 70B Standard for Electrical Equipment Maintenance requires that electrical equipment shall be maintained in accordance with the manufacturer's instructions and applicable codes and standards (NFPA 70B 4.1.1), and that the equipment owner shall implement an overall electrical maintenance program (EMP) as per NFPA 70B 4.2.1. Medium voltage (MV) distribution equipment can operate safely for many years and remain in good condition if installed in appropriate environments and properly maintained. Most organizations, even today, resort to the maintenance strategies of fix upon failure or a time- or usage-based maintenance program, and this is reflected in their EMP. However, advances in sensor technologies coupled with the dramatic growth in the information infrastructure of Internet of Things (IoT) and data analytics capabilities has opened new possibilities to rethink equipment maintenance based upon continuous monitoring of the equipment health. Such monitoring brings benefits of reduced operational costs through predictive maintenance and reduced downtime. An additional important potential benefit is an increase in personnel safety and reliability due to reduced need for onsite service and human interaction with energized equipment. In this paper we show how condition monitoring and data analytics technologies can reduce the total cost of ownership while complying with NFPA 70B.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2287-2299
Non-Stationary Phase Digital Relay for Arcing Current Faults in Medium-to-Low Voltage Power Transformers
Arcing current faults (ACFs) occurring in a medium-low voltage $3\phi$ transformer represent a challenge for transformer protection. Such faults initiate currents with different features from those triggered by conventional faults, thus making it difficult for transformer protection to accurately detect and respond to arcing current faults. This paper proposes a method for accurate detection and identification of arcing current faults in MV-LV transformers. The presented method is based on extracting the magnitudes and phases of low frequency harmonics from the differential currents. Unlike magnetizing inrush and conventional fault currents, arcing current faults trigger currents that have harmonic components with non-stationary phases. These non-stationary phases can provide signature information of arcing current faults. Multi-channel filters can accurately extract harmonic components with complex time-frequency characteristics, including non-stationary phases. In this paper, a multi-channel filter bank that is used to extract harmonic components with non-stationary phases as a signature of ACFs on the low-voltage side of a medium-low voltage $3\phi$ transformer. The used filter bank is composed of digital bandpass finite impulse response filters, each of which has a linear phase over a wide frequency range. The non-stationary phase method is tested during various fault and non-fault events. Test results demonstrate protection responses with speed, accuracy, and reliability against ACFs. Observed response features are found to have minor sensitivity to the level of loading level and/or type of the ACFs.
- 18 November 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (2) , 2287-2299
Non-Stationary Phase Digital Relay for Arcing Current Faults in Medium-to-Low Voltage Power Transformers
Arcing current faults (ACFs) occurring in a medium-low voltage $3\phi$ transformer represent a challenge for transformer protection. Such faults initiate currents with different features from those triggered by conventional faults, thus making it difficult for transformer protection to accurately detect and respond to arcing current faults. This paper proposes a method for accurate detection and identification of arcing current faults in MV-LV transformers. The presented method is based on extracting the magnitudes and phases of low frequency harmonics from the differential currents. Unlike magnetizing inrush and conventional fault currents, arcing current faults trigger currents that have harmonic components with non-stationary phases. These non-stationary phases can provide signature information of arcing current faults. Multi-channel filters can accurately extract harmonic components with complex time-frequency characteristics, including non-stationary phases. In this paper, a multi-channel filter bank that is used to extract harmonic components with non-stationary phases as a signature of ACFs on the low-voltage side of a medium-low voltage $3\phi$ transformer. The used filter bank is composed of digital bandpass finite impulse response filters, each of which has a linear phase over a wide frequency range. The non-stationary phase method is tested during various fault and non-fault events. Test results demonstrate protection responses with speed, accuracy, and reliability against ACFs. Observed response features are found to have minor sensitivity to the level of loading level and/or type of the ACFs.
- Open Access
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 30 (1) , 1-2
Table of Contents
- 13 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 30 (1) , 1-2
Open AccessTable of Contents
- 2 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 30 (1) , 23-33
The New National Fire Protection Association 70B-2023 Standard for Electrical Maintenance: The Major Points and Primary Intent
National Fire Protection Association (NFPA) 70B-2023 is now a standard for electrical equipment maintenance. As a standard, the document prescribes the minimum requirements for the maintenance of electrical equipment in industrial and various commercial installations when manufacturer instructions are not available. Electrical maintenance for the safety of personnel and the environment is primary in this standard. The document identifies what to maintain and how and intervals for performing electrical preventive maintenance. This article explains the major points and intent of the document to help develop an understanding of how to use and apply it.
- 2 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Industry Applications Magazine
- Vol. 30 (1) , 23-33
The New National Fire Protection Association 70B-2023 Standard for Electrical Maintenance: The Major Points and Primary Intent
National Fire Protection Association (NFPA) 70B-2023 is now a standard for electrical equipment maintenance. As a standard, the document prescribes the minimum requirements for the maintenance of electrical equipment in industrial and various commercial installations when manufacturer instructions are not available. Electrical maintenance for the safety of personnel and the environment is primary in this standard. The document identifies what to maintain and how and intervals for performing electrical preventive maintenance. This article explains the major points and intent of the document to help develop an understanding of how to use and apply it.
- 8 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 7462-7474
Phaselet-Based Arc Flash Relay Against Low Voltage Side Arcing Current Faults in MV-LV Power Transformers
Arcing current faults (ACFs) are undesired transient events that can occur in different power system equipment, including medium voltage-to-low voltage (MV-LV) power transformers. The main challenge in detecting, identifying, and responding to low-voltage (LV) side ACFs (in a MV-LV power transformer), is due to low magnitudes of MV side currents triggered by a LV side ACF. As a result, MV side protective devices fail to detect and respond to LV side ACFs. In many cases, the reduced ability to detect and respond to LV side ACFs prolongs the duration of LV side ACFs, and leads to a significant increase in the incident energy (may exceed acceptable limits). In this paper, an analysis of MV side currents is developed to extract signature information to ensure accurate and fast detection and identification of LV side ACFs. The proposed signature of a LV side ACF is the high frequency components (with non-stationary phases) extracted from MV side currents. Desired frequency components can be extracted using a multi-channel filter bank that is composed of digital high pass filters with linear phase responses. Such digital filters are designed using phaselet functions to ensure a simplified implementation of the desired filter bank. The accuracy and response speed of the proposed approach are utilized for designing a new arc flash relay (AFR) for MV-LV power transformers. The phaselet-based AFR is implemented and tested for a 35 kVA transformer during several transient events including LV side ACFs. Performance results reveal accurate and reliable detection, identification, and response to LV side ACFs with negligible sensitivity to loading level and/or ACF type (series or parallel).
- 8 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (6) , 7462-7474
Phaselet-Based Arc Flash Relay Against Low Voltage Side Arcing Current Faults in MV-LV Power Transformers
Arcing current faults (ACFs) are undesired transient events that can occur in different power system equipment, including medium voltage-to-low voltage (MV-LV) power transformers. The main challenge in detecting, identifying, and responding to low-voltage (LV) side ACFs (in a MV-LV power transformer), is due to low magnitudes of MV side currents triggered by a LV side ACF. As a result, MV side protective devices fail to detect and respond to LV side ACFs. In many cases, the reduced ability to detect and respond to LV side ACFs prolongs the duration of LV side ACFs, and leads to a significant increase in the incident energy (may exceed acceptable limits). In this paper, an analysis of MV side currents is developed to extract signature information to ensure accurate and fast detection and identification of LV side ACFs. The proposed signature of a LV side ACF is the high frequency components (with non-stationary phases) extracted from MV side currents. Desired frequency components can be extracted using a multi-channel filter bank that is composed of digital high pass filters with linear phase responses. Such digital filters are designed using phaselet functions to ensure a simplified implementation of the desired filter bank. The accuracy and response speed of the proposed approach are utilized for designing a new arc flash relay (AFR) for MV-LV power transformers. The phaselet-based AFR is implemented and tested for a 35 kVA transformer during several transient events including LV side ACFs. Performance results reveal accurate and reliable detection, identification, and response to LV side ACFs with negligible sensitivity to loading level and/or ACF type (series or parallel).
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5443-5452
Effects of Sampled-Values Data Quality on Responses of Time-Frequency Based Digital Relays
Time-frequency based digital protective relays can offer several advantages of high accuracy, improved reliability, and fast response over other protective relays. These protective relays employ half-band digital finite impulse response (FIR) filters to process currents and/or voltages to extract fault signatures, which facilitate accurate detection and identification of fault events. Coefficients of the employed half-band digital FIR filters are determined by wavelet or phaselet functions. The signal processing part in a time-frequency based digital protective relay processes samples of measured currents and/or voltages. As a result, attention has to be paid to the measurement, digitization, and communication of current and voltage data. Power systems utilize the IEC 61850 standard to implement data communication between measurement, control, and protection devices. This paper assesses the impacts of the IEC 61850 sampled values on the accuracy and response speed of time-frequency based digital protective relays. The presented assessment is conducted for two sample cases; the transformer differential protection and arcing current fault detection and identification. Test results show that the accuracy and response speed of time-frequency based digital protective relays are maintained, when measured currents and voltages are communicated using the IEC 61850 sampled values.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5443-5452
Effects of Sampled-Values Data Quality on Responses of Time-Frequency Based Digital Relays
Time-frequency based digital protective relays can offer several advantages of high accuracy, improved reliability, and fast response over other protective relays. These protective relays employ half-band digital finite impulse response (FIR) filters to process currents and/or voltages to extract fault signatures, which facilitate accurate detection and identification of fault events. Coefficients of the employed half-band digital FIR filters are determined by wavelet or phaselet functions. The signal processing part in a time-frequency based digital protective relay processes samples of measured currents and/or voltages. As a result, attention has to be paid to the measurement, digitization, and communication of current and voltage data. Power systems utilize the IEC 61850 standard to implement data communication between measurement, control, and protection devices. This paper assesses the impacts of the IEC 61850 sampled values on the accuracy and response speed of time-frequency based digital protective relays. The presented assessment is conducted for two sample cases; the transformer differential protection and arcing current fault detection and identification. Test results show that the accuracy and response speed of time-frequency based digital protective relays are maintained, when measured currents and voltages are communicated using the IEC 61850 sampled values.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5420-5431
On the Assessment of Sampling Rate Impacts on Responses of Digital Protective Relays
Power systems (including industrial and commercial power systems) widely utilize digital protective relays for component and system protection. These protective devices have shown numerous operational advantages over conventional electromagnetic protective devices. Such operational advantages include the accuracy, reliability, response speed, interoperability, weight, and size. Performance and operational advantages of digital protective relays are typically dependent on the resolution of their input data, as well as their algorithms for fault detection and identification. This paper assesses the performance of time-based, frequency-based, and time-frequency-based digital protective relays, when operated at different sampling rates. Tested sampling rates include low, medium, and high sampling rates that range from 16 to 288 samples per cycle. In this paper, the three digital protective relays are tested when deployed as the digital 87 T transformer digital protection. Performance of the time-based, frequency-based, and time-frequency-based digital protective relays is assessed in terms of their accuracy and response speed. Test results show that low sampling rates can deteriorate the accuracy and response speed of the three tested digital protective relays. Obtained performance results also reveal that medium and high sampling rates can effectively improve the accuracy and response speed of the time-based, frequency-based, and time-frequency-based digital protective relays.
- 20 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (5) , 5420-5431
On the Assessment of Sampling Rate Impacts on Responses of Digital Protective Relays
Power systems (including industrial and commercial power systems) widely utilize digital protective relays for component and system protection. These protective devices have shown numerous operational advantages over conventional electromagnetic protective devices. Such operational advantages include the accuracy, reliability, response speed, interoperability, weight, and size. Performance and operational advantages of digital protective relays are typically dependent on the resolution of their input data, as well as their algorithms for fault detection and identification. This paper assesses the performance of time-based, frequency-based, and time-frequency-based digital protective relays, when operated at different sampling rates. Tested sampling rates include low, medium, and high sampling rates that range from 16 to 288 samples per cycle. In this paper, the three digital protective relays are tested when deployed as the digital 87 T transformer digital protection. Performance of the time-based, frequency-based, and time-frequency-based digital protective relays is assessed in terms of their accuracy and response speed. Test results show that low sampling rates can deteriorate the accuracy and response speed of the three tested digital protective relays. Obtained performance results also reveal that medium and high sampling rates can effectively improve the accuracy and response speed of the time-based, frequency-based, and time-frequency-based digital protective relays.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 2919-2931
Experimental Performance Evaluation of the $\alpha \beta 0$-Based Bus Differential Protection
This paper presents the experimental performance assessment of the $\alpha \beta 0$ -based bus differential protection (BDP). This protection is developed for buses that interconnect battery storage systems (BSSs). The tested BDP employs $\alpha \beta 0$ components of the apparent powers flowing in all branches that are connected to the protected bus. The $\alpha \beta 0$ components of apparent powers allow accommodating frequent changes in the direction of power flows due to the charging/discharging modes of the BSS operation. In each branch connected to the protected bus, the $3\phi$ apparent powers are determined using the measured branch currents and voltage (at the protected bus). The $\alpha \beta 0$ -based BDP is implemented using a digital processing board for experimental testing for a laboratory setup. The test setup is composed of a bus that interconnects a 4 kW BSS, and feeds $3\phi$ linear and dynamic loads. The performance of the $\alpha \beta 0$ -based BDP is assessed for responding to various internal and external faults occurring during the charging and discharging of the BSS. Experimental results reveal encouraging abilities of the tested BDP to initiate fast, accurate, and reliable responses to internal and external faults. Observed response features are complimented with a negligible sensitivity to the BSS mode of operation, fault type, and/or fault location.
- 22 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (3) , 2919-2931
Experimental Performance Evaluation of the $\alpha \beta 0$-Based Bus Differential Protection
This paper presents the experimental performance assessment of the $\alpha \beta 0$ -based bus differential protection (BDP). This protection is developed for buses that interconnect battery storage systems (BSSs). The tested BDP employs $\alpha \beta 0$ components of the apparent powers flowing in all branches that are connected to the protected bus. The $\alpha \beta 0$ components of apparent powers allow accommodating frequent changes in the direction of power flows due to the charging/discharging modes of the BSS operation. In each branch connected to the protected bus, the $3\phi$ apparent powers are determined using the measured branch currents and voltage (at the protected bus). The $\alpha \beta 0$ -based BDP is implemented using a digital processing board for experimental testing for a laboratory setup. The test setup is composed of a bus that interconnects a 4 kW BSS, and feeds $3\phi$ linear and dynamic loads. The performance of the $\alpha \beta 0$ -based BDP is assessed for responding to various internal and external faults occurring during the charging and discharging of the BSS. Experimental results reveal encouraging abilities of the tested BDP to initiate fast, accurate, and reliable responses to internal and external faults. Observed response features are complimented with a negligible sensitivity to the BSS mode of operation, fault type, and/or fault location.
- 4 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 2386-2399
Experimental Assessment of Ground Fault Protection in Frequency-Selective Grounded Systems Fed by a Single Transformer
This paper presents performance assessment of ground fault protection for systems supplied by a transformer, which has frequency-selective grounding. Frequency-selective grounding is a new grounding system that is designed to act as a solid-grounding for high frequency currents, and as a low resistance-grounding for low frequency currents. This grounding system is composed from a parallel $R-C$ circuit with an equivalent impedance able to affect system zero-sequence currents and ground potentials. Such effects on zero-sequence currents and ground potentials can directly impact the accuracy and response speed of ground fault protection. Effects of frequency-selective grounding on ground fault protection are experimentally assessed for different fault and non-fault events, when the transformer supplies linear and non-liner loads. Experimental results demonstrate responses of various implementations of ground fault protection to fault and non-fault events, when the protected system has frequency selective grounding. Moreover, presented results and discussions aim to demonstrate the ability of frequency-selective grounding to support the operation of ground fault protection during different loading conditions and fault events.
- 4 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 2386-2399
Experimental Assessment of Ground Fault Protection in Frequency-Selective Grounded Systems Fed by a Single Transformer
This paper presents performance assessment of ground fault protection for systems supplied by a transformer, which has frequency-selective grounding. Frequency-selective grounding is a new grounding system that is designed to act as a solid-grounding for high frequency currents, and as a low resistance-grounding for low frequency currents. This grounding system is composed from a parallel $R-C$ circuit with an equivalent impedance able to affect system zero-sequence currents and ground potentials. Such effects on zero-sequence currents and ground potentials can directly impact the accuracy and response speed of ground fault protection. Effects of frequency-selective grounding on ground fault protection are experimentally assessed for different fault and non-fault events, when the transformer supplies linear and non-liner loads. Experimental results demonstrate responses of various implementations of ground fault protection to fault and non-fault events, when the protected system has frequency selective grounding. Moreover, presented results and discussions aim to demonstrate the ability of frequency-selective grounding to support the operation of ground fault protection during different loading conditions and fault events.
- 2 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 2400-2412
Testing Ground Fault Protection of Generating Units With Frequency-Selective Grounding
This paper experimentally evaluates responses of ground fault protection for synchronous generators, which are grounded using frequency-selective grounding. Frequency-selective grounding is designed to provide a low ground impedance path (similar to solid grounding) for high frequency zero-sequence current components. This grounding system also provides an impedance similar to a low-resistance grounding for low frequency zero-sequence current components. The frequency-dependent equivalent impedance of frequency-selective grounding can affect ground potential and current, which are typically used as inputs for ground fault protective relays. Effects of frequency-selective grounding on ground fault protection are experimentally evaluated using a 7.5 kVA synchronous generator. Experimental tests are conducted for different implementations of ground fault protection, when responding to fault and non-fault events. Evaluation results detailed in this paper demonstrate the negligible effects of frequency-selective grounding on responses of different ground fault protective relays.
- 2 January 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 59 (2) , 2400-2412
Testing Ground Fault Protection of Generating Units With Frequency-Selective Grounding
This paper experimentally evaluates responses of ground fault protection for synchronous generators, which are grounded using frequency-selective grounding. Frequency-selective grounding is designed to provide a low ground impedance path (similar to solid grounding) for high frequency zero-sequence current components. This grounding system also provides an impedance similar to a low-resistance grounding for low frequency zero-sequence current components. The frequency-dependent equivalent impedance of frequency-selective grounding can affect ground potential and current, which are typically used as inputs for ground fault protective relays. Effects of frequency-selective grounding on ground fault protection are experimentally evaluated using a 7.5 kVA synchronous generator. Experimental tests are conducted for different implementations of ground fault protection, when responding to fault and non-fault events. Evaluation results detailed in this paper demonstrate the negligible effects of frequency-selective grounding on responses of different ground fault protective relays.