Sargis Ter-Avetisyan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Sargis Ter-Avetisyan has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Kwinten Nelissen
ELI-ALPS Research Institute, ELI-HU Non-Profit Ltd., Wolfgang Sandner utca 3, 6728 Szeged, Hungary
3 shared publications - Antonia Morabito
Centro de Láseres Pulsados (CLPU)
2 shared publications Janos Csontos
ELI-ALPS, ELI-HU Non-Profit Ltd, Szeged, Hungary
2 shared publicationsJoon-Gon Son
National Laser-Initiated Transmutation Laboratory, University of Szeged, 6720 Szeged, Hungary
2 shared publications- Mauro Migliorati
Università di Roma La Sapienza
2 shared publications - Prashant Kumar Singh
Tata Institute of Fundamental Research
2 shared publications
Latest Publications
- Open Access
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3237 (1)
Use of liquid spray for conversion of a positive ion into a negative ion and a neutral atom
Beams of energetic positive ions—specifically hydrogen and carbon ions—were converted into beams of negative ions and neutral atoms as they passed through a spray of submicron liquid droplets. The divergence of the positive ion beam is preserved in the converted beam. Converted negative ion and neutral atom beams retain the property of positive ion beam. This proof of principle experiment offers improved neutralization efficiency of positive ions: 38% for the H + → H 0 and 50% for the C 4+ → C 0 reactions, compared to gas neutralizers. This simple system, compared to gas neutralizers, can be an attractive option for neutral beam injection (NBI) systems and require further study.
- 1 May 2026
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 3237 (1)
Open AccessUse of liquid spray for conversion of a positive ion into a negative ion and a neutral atom
Beams of energetic positive ions—specifically hydrogen and carbon ions—were converted into beams of negative ions and neutral atoms as they passed through a spray of submicron liquid droplets. The divergence of the positive ion beam is preserved in the converted beam. Converted negative ion and neutral atom beams retain the property of positive ion beam. This proof of principle experiment offers improved neutralization efficiency of positive ions: 38% for the H + → H 0 and 50% for the C 4+ → C 0 reactions, compared to gas neutralizers. This simple system, compared to gas neutralizers, can be an attractive option for neutral beam injection (NBI) systems and require further study.
- 13 June 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 219
Development of liquid spray neutralizer for neutral beam injection (NBI) for fusion devices
- 13 June 2025
- Published by Elsevier in Fusion Engineering and Design
- Vol. 219
Development of liquid spray neutralizer for neutral beam injection (NBI) for fusion devices
- Open Access
Novel Spectrometer Designs for Laser-Driven Ion Acceleration
We propose novel spectrometer designs that aim to enhance the measured spectral range of ions on a finite-sized detector. In contrast to the traditional devices that use a uniform magnetic field, in which the deflection of particles increases inversely proportional to their momentum, in a gradient magnetic field, the deflection of particles will decrease due to the reduction of the magnetic field along their propagation. In this way, low-energy ions can reach the detector because they are deflected less, compared to the uniform field case. By utilizing a gradient magnetic field, the non-linear dispersion of ions in a homogeneous magnetic field approaches nearly linear dispersion behavior. Nonetheless, the dispersion of low-energy ions, using a dipole field, remains unnecessarily high. In this article, we discuss the employed methodology and present simulation results of the spectrometer with an extended ion spectral range, focusing on the minimum detectable energy (energy dynamic range) and energy resolution.
Open AccessNovel Spectrometer Designs for Laser-Driven Ion Acceleration
We propose novel spectrometer designs that aim to enhance the measured spectral range of ions on a finite-sized detector. In contrast to the traditional devices that use a uniform magnetic field, in which the deflection of particles increases inversely proportional to their momentum, in a gradient magnetic field, the deflection of particles will decrease due to the reduction of the magnetic field along their propagation. In this way, low-energy ions can reach the detector because they are deflected less, compared to the uniform field case. By utilizing a gradient magnetic field, the non-linear dispersion of ions in a homogeneous magnetic field approaches nearly linear dispersion behavior. Nonetheless, the dispersion of low-energy ions, using a dipole field, remains unnecessarily high. In this article, we discuss the employed methodology and present simulation results of the spectrometer with an extended ion spectral range, focusing on the minimum detectable energy (energy dynamic range) and energy resolution.
- Open Access
- 14 May 2024
- Published by MDPI AG in Preprints.org
Novel Spectrometer Designs for Laser Driven Ion Acceleration
We propose novel spectrometer designs that aim to enhance the measured spectral range 1 of ions on a finite-sized detector. In contrast to the traditional devices that use uniform magnetic 2 field, in which the deflection of particles increases inversely proportional to their momentum, in a 3 gradient magnetic field, the deflection of particles will be decreased due to the reduction of the 4 magnetic field along their propagation. Low energy ions are particularly impacted, as they are 5 deflected less and are more likely to reach the detector compared to being driven out of it while 6 using a uniform magnetic field. By the means of a gradient magnetic field, the nonlinear dispersion 7 of ions in a homogeneous magnetic field can approach a nearly linear dispersion. Nonetheless, 8 the dispersion of low energy ions in a homogeneous magnetic field remains unnecessarily high. 9 In this article, we explore linear, quadratic, and higher-order field profiles in comparison to the 10 homogeneous field case. We discuss the employed methodology and present simulation results of 11 the spectrometer with an extended ion spectral range, focusing on the minimum detectable energy 12 (energy dynamic range) and energy resolution
- 14 May 2024
- Published by MDPI AG in Preprints.org
Open AccessNovel Spectrometer Designs for Laser Driven Ion Acceleration
We propose novel spectrometer designs that aim to enhance the measured spectral range 1 of ions on a finite-sized detector. In contrast to the traditional devices that use uniform magnetic 2 field, in which the deflection of particles increases inversely proportional to their momentum, in a 3 gradient magnetic field, the deflection of particles will be decreased due to the reduction of the 4 magnetic field along their propagation. Low energy ions are particularly impacted, as they are 5 deflected less and are more likely to reach the detector compared to being driven out of it while 6 using a uniform magnetic field. By the means of a gradient magnetic field, the nonlinear dispersion 7 of ions in a homogeneous magnetic field can approach a nearly linear dispersion. Nonetheless, 8 the dispersion of low energy ions in a homogeneous magnetic field remains unnecessarily high. 9 In this article, we explore linear, quadratic, and higher-order field profiles in comparison to the 10 homogeneous field case. We discuss the employed methodology and present simulation results of 11 the spectrometer with an extended ion spectral range, focusing on the minimum detectable energy 12 (energy dynamic range) and energy resolution
- Open Access
- 3 July 2023
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 65 (8) , 085012
Ion acceleration with few-cycle relativistic laser pulses from foil targets
Ion acceleration resulting from the interaction of 11 fs laser pulses of ∼ 35 mJ energy with ultrahigh contrast (−10) and 1019 W cm−2 peak intensity with foil targets made of various materials and thicknesses at normal (0°) and 45° laser incidence is investigated. The maximum energy of the protons reached ∼1.4 MeV accelerated in the laser propagation direction and ∼1.2 MeV in the opposite direction from a formvar target. The energy conversion efficiency from the laser to the proton beam is estimated to be as high as ∼1.4% at 45° laser incidence using a 51 nm thick Al target. The high laser contrast indicates the predominance of vacuum heating via Brunel’s effect as an absorption mechanism involving a tiny pre-plasma at the target front. The experimental results are in reasonable agreement with theoretical estimates, where proton acceleration from the target front side in the backward direction is well explained by the Coulomb explosion of a charged cavity formed in a tiny pre-plasma, while forward proton acceleration is likely to be a two-step process: protons are first accelerated in the target front-side cavity and then further boosted in energy through the target back side via the target normal sheath acceleration (TNSA) mechanism.
- 3 July 2023
- Published by IOP Publishing in Plasma Physics and Controlled Fusion
- Vol. 65 (8) , 085012
Open AccessIon acceleration with few-cycle relativistic laser pulses from foil targets
Ion acceleration resulting from the interaction of 11 fs laser pulses of ∼ 35 mJ energy with ultrahigh contrast (−10) and 1019 W cm−2 peak intensity with foil targets made of various materials and thicknesses at normal (0°) and 45° laser incidence is investigated. The maximum energy of the protons reached ∼1.4 MeV accelerated in the laser propagation direction and ∼1.2 MeV in the opposite direction from a formvar target. The energy conversion efficiency from the laser to the proton beam is estimated to be as high as ∼1.4% at 45° laser incidence using a 51 nm thick Al target. The high laser contrast indicates the predominance of vacuum heating via Brunel’s effect as an absorption mechanism involving a tiny pre-plasma at the target front. The experimental results are in reasonable agreement with theoretical estimates, where proton acceleration from the target front side in the backward direction is well explained by the Coulomb explosion of a charged cavity formed in a tiny pre-plasma, while forward proton acceleration is likely to be a two-step process: protons are first accelerated in the target front-side cavity and then further boosted in energy through the target back side via the target normal sheath acceleration (TNSA) mechanism.
- 1 October 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (10) , 103104
Threshold target thickness in high-contrast laser-driven ion acceleration
The experiments have revealed a “threshold” target thickness for proton acceleration by a femtosecond petawatt class laser above which the forward accelerated proton energy weakly depends on the target thickness, while for thinner targets, it gradually decreases. For targets thicker than the threshold, the pre-pulse-induced preplasma at the target front can boost ion acceleration by increasing laser absorption, while this is ineffective for thinner targets due to prepulse-induced plasma formation at the target rear. This dual nature of the preplasma is described analytically, and particle-in-cell simulations confirm this concept. A linear dependence of threshold target thickness on the prepulse intensity is predicted.
- 1 October 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (10) , 103104
Threshold target thickness in high-contrast laser-driven ion acceleration
The experiments have revealed a “threshold” target thickness for proton acceleration by a femtosecond petawatt class laser above which the forward accelerated proton energy weakly depends on the target thickness, while for thinner targets, it gradually decreases. For targets thicker than the threshold, the pre-pulse-induced preplasma at the target front can boost ion acceleration by increasing laser absorption, while this is ineffective for thinner targets due to prepulse-induced plasma formation at the target rear. This dual nature of the preplasma is described analytically, and particle-in-cell simulations confirm this concept. A linear dependence of threshold target thickness on the prepulse intensity is predicted.
- 1 July 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (7) , 073301
Calibration of micro-channel plate detector in a Thomson spectrometer for protons and carbon ions with energies below 1 MeV
The calibration of an ion detection system was carried out for protons and carbon ions from a few tens of keV up to about 1 MeV energies. A Thomson spectrometer deflecting the particle beam accelerated from a laser plasma creates the ion spectra on a phosphor screen behind a micro-channel plate (MCP), which are recorded by a camera. During calibration, the ion spectra simultaneously hit the slotted CR-39 track detector installed in front of the MCP and, passing through the adjacent CR-39 stripes, the MCP. The calibration provides the ratio of the interpolated values between two consecutive stripes of the camera signal and the total number of particles recorded on the corresponding stripe of CR-39. The efficiency of proton detection by CR-39 was also measured in a conventional accelerator beam and found to drop by 20% below 100 keV.
- 1 July 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (7) , 073301
Calibration of micro-channel plate detector in a Thomson spectrometer for protons and carbon ions with energies below 1 MeV
The calibration of an ion detection system was carried out for protons and carbon ions from a few tens of keV up to about 1 MeV energies. A Thomson spectrometer deflecting the particle beam accelerated from a laser plasma creates the ion spectra on a phosphor screen behind a micro-channel plate (MCP), which are recorded by a camera. During calibration, the ion spectra simultaneously hit the slotted CR-39 track detector installed in front of the MCP and, passing through the adjacent CR-39 stripes, the MCP. The calibration provides the ratio of the interpolated values between two consecutive stripes of the camera signal and the total number of particles recorded on the corresponding stripe of CR-39. The efficiency of proton detection by CR-39 was also measured in a conventional accelerator beam and found to drop by 20% below 100 keV.