Xiaohui Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xiaohui Chen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chunying He
School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications - Xiaoguang Zhu
School of Electrical Engineering, Xian Jiaotong University, Xian, China
2 shared publications Feiyue Ma
State Grid Ningxia Electric Power Corporation Research Institute, Yinchuan, China
1 shared publication- Guanjun Zhang
Xi’an Jiaotong University
1 shared publication Hui Ni
State Grid Ningxia Electric Power Corporation Research Institute, Yinchuan, China
1 shared publicationJunbo Deng
1 shared publication
Latest Publications
- 17 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3381-3390
Energization Transient Suppression of 750 kV AC Filters Using a Preinsertion Resistor Circuit Breaker With a Controlled Switching Device
Different from typical circuit breakers, breakers used to switch AC filters in convertor stations have to operate frequently according to the real-time operation mode and daily load changes. Therefore, the performance of filter breakers decreases very quickly, which leads to frequent accidents. Both preinsertion resistors and controlled switching devices can suppress switching transients. In this paper, a comparative analysis of whether a controlled switching device and preinsertion resistor should be adopted is carried out using PSCAD. The transient is calculated as the combined result of the switching angle and preinsertion resistor value, and the optimal configurations are proposed. After determining the resistor value and whether a controlled switching device should be included, the reference voltage of the arrester should be reevaluated.
- 17 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 37 (4) , 3381-3390
Energization Transient Suppression of 750 kV AC Filters Using a Preinsertion Resistor Circuit Breaker With a Controlled Switching Device
Different from typical circuit breakers, breakers used to switch AC filters in convertor stations have to operate frequently according to the real-time operation mode and daily load changes. Therefore, the performance of filter breakers decreases very quickly, which leads to frequent accidents. Both preinsertion resistors and controlled switching devices can suppress switching transients. In this paper, a comparative analysis of whether a controlled switching device and preinsertion resistor should be adopted is carried out using PSCAD. The transient is calculated as the combined result of the switching angle and preinsertion resistor value, and the optimal configurations are proposed. After determining the resistor value and whether a controlled switching device should be included, the reference voltage of the arrester should be reevaluated.