Yang Wu
Research Subjects
Research Interests
Yang Wu has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Bin Liu
Institute of Nuclear Physics and Chemistry, Mianyang 621900, China
1 shared publication - Bin Tang
China Acad Engn Phys, Inst Nucl Phys & Chem, Mianyang 621999, Peoples R China
1 shared publication - Chao Cao
Zhejiang Institute of Modern Physics Zhejiang University 310027 Hangzhou China
1 shared publication - Chunlei Wu
Institute of Nuclear Physics and Chemistry, Mianyang 621900, China
1 shared publication - Hang Li
Chinese Academy of Engineering Physics, Mianyang, China
1 shared publication - Heyong Huo
Institute of Nuclear Physics and Chemistry, China Academy of Engineering Physics, Mianyang 621000, China
1 shared publication
Latest Publications
- Open Access
A Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source
A novel non-destructive testing scanning system based on a large-size line array fast neutron detector and compact D-T neutron source has been constructed. The scanning range is up to 1000 mm, and the resolution is better than 1 mm. The fast neutron detection subsystem consists of a polypropylene zinc sulfide scintillator embedded with wavelength-shifting fibers, coupled with a light lens and a scientific CCD camera. With a new rotating tritium target, the lifetime of the compact D-T neutron source could achieve ten hours. The experimental results indicate that the scanning method based on line array fast neutron detector and D-T neutron source is feasible and enables the detection of slits on the order of 0.5 mm in width. Fast neutron tomography has been realized by this detection system too.
Open AccessA Novel NDT Scanning System Based on Line Array Fast Neutron Detector and D-T Neutron Source
A novel non-destructive testing scanning system based on a large-size line array fast neutron detector and compact D-T neutron source has been constructed. The scanning range is up to 1000 mm, and the resolution is better than 1 mm. The fast neutron detection subsystem consists of a polypropylene zinc sulfide scintillator embedded with wavelength-shifting fibers, coupled with a light lens and a scientific CCD camera. With a new rotating tritium target, the lifetime of the compact D-T neutron source could achieve ten hours. The experimental results indicate that the scanning method based on line array fast neutron detector and D-T neutron source is feasible and enables the detection of slits on the order of 0.5 mm in width. Fast neutron tomography has been realized by this detection system too.