NWNing Wang

Ning Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ning Wang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    TDN-PPO: An Automatic Control Framework of a Surgical Robot for Posterior Segment Ophthalmic Surgery

    by Ning Wang, Xiaodong Zhang, Sophia Bano, Danail Stoyanov, Ziting Liang, Agostino Stilli

    In ophthalmic surgery, particularly the procedures involving the posterior segment, clinicians face significant challenges in maintaining precise control of handheld instruments to peel fragile membranes without damaging the surrounding healthy fundus tissue, even for seasoned clinicians employing specialised ophthalmic surgical robots. The implementation of autonomous control in robot-assisted surgical systems holds promise for overcoming these obstacles and simplifying intricate surgical tasks. This paper introduces an autonomous control framework, integrating a Tip Detection Network (TDN) with a Proximal Policy Optimization (PPO) network, designed to autonomously navigate the Tip of the Surgical Instrument (ToSI) towards the intended lesion site in a real-world scenario. Results indicate that the accuracy of the TDN module in detecting the ToSI position in images of varying sizes can be reliably maintained within a 4.6-pixel range. The autonomous control deviation for the PPO module ranges between [0.6585μm, 7.995μm], with an average discrepancy of 5.118μm. The communication frequency across the modules is maintained at 35.7 Hz. In physical environments, the TDN-PPO framework adeptly navigates the ToSI to autonomously and precisely converge on the preset Target Lesion (TL) macular hole, maintaining a tip-to-target distance error within a margin of 2.094 pixels (38μm). Throughout the autonomous navigation phase, the maximal contact force between the ToSI and the TL is capped at 41.1 mN, aligning with the upper threshold for contact force between the ToSI and tissue prescribed in clinical surgical settings.

  • Open Access

    FBG-based 3D micro-force sensor integrated into ophthalmic microsurgical robotic forceps

    by Ning Wang, Xiaodong Zhang, Mingyang Li, Agostino Stilli, Sophia Bano, Danail Stoyanov

  • Vision-Based Automatic Control of a Surgical Robot for Posterior Segment Ophthalmic Surgery

    by Ning Wang, Xiaodong Zhang, Sophia Bano, Danail Stoyanov, Hongbing Zhang, Agostino Stilli

    In ophthalmic surgery, especially in posterior segment procedures, clinicians face significant challenges, like the inherent tremor of the surgeon’s arm, restricted visibility, and heavy reliance on the surgeon’s skills for precise control of hand-held tools during micro-surgical movements. Automatic control of robotic-assisted ophthalmic surgical systems has the potential to overcome these challenges, simplifying complex surgical procedures. This paper proposes a novel image-guided automatic control method for an Ophthalmic micro-Surgical Robot (OmSR), specifically designed for posterior segment eye surgery. The method relies on forceps shadow tracking. The paper introduces a tip detection network (Net-SR), which accurately calculates the coordinates of the Tips of Surgical Forceps (ToSF) and Tips of Shadow (ToS) to enable automatic navigation. Additionally, through the Non-Uniform Rational B-Spline (NURBS) curve interpolation and speed look-ahead algorithm, dense and time-continuous data points are obtained to improve control accuracy and smoothness. The accuracy of the Net-SR network and motion of the ToSF, and the effectiveness of the proposed automatic controller are experimentally evaluated. Results demonstrate a significant 98.21% improvement in the Net-SR network accuracy over the normal keypoint detection network. The use of the speed look-ahead algorithm leads to a notable 41.7% improvement in optimal speed, and the ToSF successfully reaches the target lesion with vision-based navigation and no overscale motion. Note to Practitioners —The practical problem that motivated this research is the need for safer and more efficient surgical procedures, focusing on minimizing the risk of fundus tissue damage associated with intraoperative surgical instruments. To overcome challenges related to handheld and tele-operated control, we explore automatic control as a promising solution. In this paper, the tip of the instrument can consistently and accurately reach the target lesion with high precision and no overscale motion, allowing for deskilling of complex and repetitive tasks. This capability holds potential for the clinical needle insertion operation and membrane peeling operation. The proposed control methods can also be extended to other surgical procedures.


  • Vision-and-Force-Based Compliance Control for a Posterior Segment Ophthalmic Surgical Robot

    by Ning Wang, Xiaodong Zhang, Danail Stoyanov, Hongbing Zhang, Agostino Stilli

    In ophthalmic surgery, particularly in procedures involving the posterior segment, clinicians face significant challenges in maintaining precise control of hand-held instruments without damaging the fundus tissue. Typical targets of this type of surgery are the internal limiting membrane (ILM) and the epiretinal membrane (ERM) which have an average thickness of only 60 $\mu \rm{m}$ and 2 $\mu \rm{m}$ , respectively, making it challenging, even for experienced clinicians utilising dedicated ophthalmic surgical robots, to peel these delicate membranes successfully without damaging the healthy tissue. Minimal intra-operative motion errors when driving both hand-held and robotic-assisted surgical tools may result in significant stress on the delicate tissue of the fundus, potentially causing irreversible damage to the eye. To address these issues, this work proposes an intra-operative vision-and-force-based compliance control method for a posterior segment ophthalmic surgical robot. This method aims to achieve compliance control of the surgical instrument in contact with the tissue to minimise the risk of tissue damage. In this work we demonstrate that we can achieve a maximum motion error for the end effector (EE) of our ophthalmic robot of just 8 $\mu \rm{m}$ , resulting in a 64 $\%$ increase in motion accuracy compared to our previous work where the system was firstly introduced. The results of the proposed compliance control demonstrate consistent performance in the force range of 40 $\rm{mN}$ during membrane tearing.


  • A 5-DOFs Robot for Posterior Segment Eye Microsurgery

    by Ning Wang, Xiaodong Zhang, Mingyang Li, Hongbing Zhang, Danail Stoyanov, Agostino Stilli

    In retinal surgery clinicians access the internal volume of the eyeball through small scale trocar ports, typically 0.65 mm in diameter, to treat vitreoretinal disorders like idiopathic epiretinal membrane and age-related macular holes. The treatment of these conditions involves the removal of thin layers of diseased tissue, namely the epiretinal membrane and the internal limiting membrane. These membranes have an average thickness of only 60 μm and 2 μm respectively making extremely challenging even for expert clinicians to peel without damaging the surrounding tissue. In this work we present a novel Ophthalmic microsurgery Robot (OmSR) designed to operate a standard surgical forceps used in these procedures with micrometric precision, overcoming the limitations of current robotic systems associated with the offsetting of the remote centre of motion of the end effector when accessing the sclera. The design of the proposed system is presented, and its performance evaluated. The results show that the end effector can be controlled with an accuracy of less than 30 μm and the surgical forceps opening and closing positional error is less than 4.3 μm. Trajectory-following experiments and membrane peeling experiments are also presented, showing promising results in both scenarios.