Memori Fukuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Memori Fukuda has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Sho Okiyama
Department of Digital Health, Institute of Medicine, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki, 305-8571, Japan, +81 90 6522 4161
4 shared publications - Hiroaki Kato
Aillis, Inc Tokyo Japan
2 shared publications - Masahiro Ikeda
Center for Advanced Intelligence Project RIKEN 103-0027 Tokyo Japan
2 shared publications - Masao Iwagami
Department of Digital Health, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
2 shared publications - Masashi Sode
The University of North Carolina at Chapel Hill
2 shared publications - Saho Kameyama
Aillis, Inc, Tokyo, Japan
2 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by Oxford University Press (OUP) in Journal of Occupational Health
Changes in Health Literacy and Subsequent Presenteeism Among Workers: A Repeated-Measures Longitudinal Database Study
Objectives: To examine associations of changes in health literacy with subsequent changes in presenteeism and incident presenteeism among Japanese workers. Methods: We analyzed 8 semiannual in-app surveys (June 2021-December 2024) from the DeSC database. Health literacy (HL) was measured with the 5-item Communicative and Critical Health Literacy scale (1-5), and presenteeism (Pres) with the WPAI-presenteeism item (0%-100%; higher indicating greater impairment; employed respondents only). Each observation used 3 consecutive waves: ΔHL(t-1)=HL(t-1)-HL(t-2) and subsequent ΔPres(t)=Pres(t)-Pres(t-1). Linear mixed models adjusted for prior Pres, earlier HL, and demographic, occupational, health-status, and lifestyle covariates; sensitivity analysis modeled prior Pres categorically. Additional analyses examined observations with prior presenteeism (Pres(t-1)>0), without prior presenteeism (Pres(t-1)=0) and categorical HL changes. Results: Among 19,594 participants (60,203 observations), a 1-point more positive ΔHL was associated with more favorable subsequent ΔPres (β -1.24 percentage points; 95% confidence interval [CI], -1.52 to -0.97), with consistent sensitivity and prior-presenteeism findings; the incident odds ratio was 0.89 (0.84-0.93). Compared with unchanged HL, decreases were associated with less favorable changes (0.87; 0.46-1.27), whereas increases had a CI including zero (-0.32; -0.75 to 0.10). Increases of at least 0.6 points showed favorable exploratory associations. The individual-level association was modest (approximately -0.83 percentage points per standard deviation of ΔHL). Conclusions: More positive HL changes were associated with modestly more favorable presenteeism outcomes. Direction-based associations were clear for decreases but not increases; larger increases showed favorable exploratory associations. Intervention effects require further study.
- 2 November 2026
- Published by Oxford University Press (OUP) in Journal of Occupational Health
Open AccessChanges in Health Literacy and Subsequent Presenteeism Among Workers: A Repeated-Measures Longitudinal Database Study
Objectives: To examine associations of changes in health literacy with subsequent changes in presenteeism and incident presenteeism among Japanese workers. Methods: We analyzed 8 semiannual in-app surveys (June 2021-December 2024) from the DeSC database. Health literacy (HL) was measured with the 5-item Communicative and Critical Health Literacy scale (1-5), and presenteeism (Pres) with the WPAI-presenteeism item (0%-100%; higher indicating greater impairment; employed respondents only). Each observation used 3 consecutive waves: ΔHL(t-1)=HL(t-1)-HL(t-2) and subsequent ΔPres(t)=Pres(t)-Pres(t-1). Linear mixed models adjusted for prior Pres, earlier HL, and demographic, occupational, health-status, and lifestyle covariates; sensitivity analysis modeled prior Pres categorically. Additional analyses examined observations with prior presenteeism (Pres(t-1)>0), without prior presenteeism (Pres(t-1)=0) and categorical HL changes. Results: Among 19,594 participants (60,203 observations), a 1-point more positive ΔHL was associated with more favorable subsequent ΔPres (β -1.24 percentage points; 95% confidence interval [CI], -1.52 to -0.97), with consistent sensitivity and prior-presenteeism findings; the incident odds ratio was 0.89 (0.84-0.93). Compared with unchanged HL, decreases were associated with less favorable changes (0.87; 0.46-1.27), whereas increases had a CI including zero (-0.32; -0.75 to 0.10). Increases of at least 0.6 points showed favorable exploratory associations. The individual-level association was modest (approximately -0.83 percentage points per standard deviation of ΔHL). Conclusions: More positive HL changes were associated with modestly more favorable presenteeism outcomes. Direction-based associations were clear for decreases but not increases; larger increases showed favorable exploratory associations. Intervention effects require further study.
- Open Access
- 22 November 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e87705
A Three-Tier Artificial Intelligence Model for COVID-19 Triage Using Pharyngeal Images (Preprint)
Background: SARS-CoV-2 remains a common cause of acute respiratory illness; however, symptom-based triage poorly discriminates it from other febrile conditions. A recently developed artificial intelligence (AI)–powered pharyngeal camera acquires pharyngeal images and clinical data to assist in influenza diagnosis; leveraging this workflow, we evaluated an adjunct AI algorithm (COVID-19-AI) that reports high, medium, or low suspicion to guide whether SARS-CoV-2 testing should subsequently be performed. Objective: This study aimed to report diagnostic accuracy outcomes and clinical utility of the COVID-19-AI as a triage support tool. Methods: We conducted a performance evaluation using a prospectively collected multicenter dataset from 26 Japanese institutions between December 2023 and March 2024. Patients with suspected influenza or COVID-19 were eligible. The COVID-19-AI algorithm, a stacked ensemble of a Swin Transformer and boosting models, was developed using pharyngeal images combined with routine clinical variables from 2133 patients, and it produced a 3-tier output. Classification thresholds were predefined to optimize clinical rule-out and rule-in utilities. Diagnostic performance was assessed in 696 independent patients against centralized reverse transcription polymerase chain reaction–confirmed SARS-CoV-2 infection under 2 prespecified operating criteria: inclusive (high or medium=positive and low=negative) and strict (high=positive and medium or low=negative). A subanalysis stratified accuracy by time from symptom onset (12-hour bins to 72 hours). Results: Among 696 analyzed participants (all Asian), 247 (35.5%) had reverse transcription polymerase chain reaction–confirmed SARS-CoV-2 infection. The COVID-19-AI categorized 12.4% (n=86), 72.8% (n=507), and 14.8% (n=103) patients as high, medium, and low suspicion, respectively. Under the inclusive criteria, sensitivity of COVID-19-AI was 93.9% (95% CI 90.4%‐96.4%), specificity was 19.6% (95% CI 16.1%‐23.5%), and negative predictive value was 85.4% (95% CI 77.6%‐91.3%). Under the strict criteria, sensitivity was 24.7% (95% CI 19.6%‐30.4%), specificity was 94.4% (95% CI 92.0%‐96.3%), and positive predictive value was 70.9% (95% CI 60.7%‐79.8%). Across 12-hour onset strata, sensitivity under the inclusive criteria remained ≥92.0% and specificity under the strict criteria remained ≥83.3%; no pronounced temporal trend was observed. Additionally, an integrated model using both pharyngeal images and clinical variables (area under the receiver operating characteristic curve [AUROC] 0.78) outperformed models using only clinical variables (AUROC 0.75) or images alone (AUROC 0.71); feature importance analysis further confirmed that pharyngeal image information was the most influential individual predictor, providing greater predictive value than any single clinical variable. Conclusions: Embedded within AI-powered pharyngeal camera workflows, a 3-tier AI suspicion output enables complementary operating behaviors—high sensitivity to rule out COVID-19 (inclusive criteria) and high specificity to support immediate infection control measures (strict criteria), although these criteria involve inherent trade-offs with low specificity and low sensitivity, respectively. Performance stability across onset times suggests robustness to symptom chronology, offering a standardized tool for clinical triage.
- 22 November 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 10, e87705
Open AccessA Three-Tier Artificial Intelligence Model for COVID-19 Triage Using Pharyngeal Images (Preprint)
Background: SARS-CoV-2 remains a common cause of acute respiratory illness; however, symptom-based triage poorly discriminates it from other febrile conditions. A recently developed artificial intelligence (AI)–powered pharyngeal camera acquires pharyngeal images and clinical data to assist in influenza diagnosis; leveraging this workflow, we evaluated an adjunct AI algorithm (COVID-19-AI) that reports high, medium, or low suspicion to guide whether SARS-CoV-2 testing should subsequently be performed. Objective: This study aimed to report diagnostic accuracy outcomes and clinical utility of the COVID-19-AI as a triage support tool. Methods: We conducted a performance evaluation using a prospectively collected multicenter dataset from 26 Japanese institutions between December 2023 and March 2024. Patients with suspected influenza or COVID-19 were eligible. The COVID-19-AI algorithm, a stacked ensemble of a Swin Transformer and boosting models, was developed using pharyngeal images combined with routine clinical variables from 2133 patients, and it produced a 3-tier output. Classification thresholds were predefined to optimize clinical rule-out and rule-in utilities. Diagnostic performance was assessed in 696 independent patients against centralized reverse transcription polymerase chain reaction–confirmed SARS-CoV-2 infection under 2 prespecified operating criteria: inclusive (high or medium=positive and low=negative) and strict (high=positive and medium or low=negative). A subanalysis stratified accuracy by time from symptom onset (12-hour bins to 72 hours). Results: Among 696 analyzed participants (all Asian), 247 (35.5%) had reverse transcription polymerase chain reaction–confirmed SARS-CoV-2 infection. The COVID-19-AI categorized 12.4% (n=86), 72.8% (n=507), and 14.8% (n=103) patients as high, medium, and low suspicion, respectively. Under the inclusive criteria, sensitivity of COVID-19-AI was 93.9% (95% CI 90.4%‐96.4%), specificity was 19.6% (95% CI 16.1%‐23.5%), and negative predictive value was 85.4% (95% CI 77.6%‐91.3%). Under the strict criteria, sensitivity was 24.7% (95% CI 19.6%‐30.4%), specificity was 94.4% (95% CI 92.0%‐96.3%), and positive predictive value was 70.9% (95% CI 60.7%‐79.8%). Across 12-hour onset strata, sensitivity under the inclusive criteria remained ≥92.0% and specificity under the strict criteria remained ≥83.3%; no pronounced temporal trend was observed. Additionally, an integrated model using both pharyngeal images and clinical variables (area under the receiver operating characteristic curve [AUROC] 0.78) outperformed models using only clinical variables (AUROC 0.75) or images alone (AUROC 0.71); feature importance analysis further confirmed that pharyngeal image information was the most influential individual predictor, providing greater predictive value than any single clinical variable. Conclusions: Embedded within AI-powered pharyngeal camera workflows, a 3-tier AI suspicion output enables complementary operating behaviors—high sensitivity to rule out COVID-19 (inclusive criteria) and high specificity to support immediate infection control measures (strict criteria), although these criteria involve inherent trade-offs with low specificity and low sensitivity, respectively. Performance stability across onset times suggests robustness to symptom chronology, offering a standardized tool for clinical triage.
- Open Access
- 22 November 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Artificial Intelligence–Guided Triage for COVID–19 Testing Using Pharyngeal Images (Preprint)
BACKGROUND COVID-19 remains a common cause of acute respiratory illness, yet symptom-based triage poorly discriminates it from other febrile conditions. A recently developed artificial intelligence (AI)-powered pharyngeal camera acquires pharyngeal images and clinical data to assist influenza diagnosis; leveraging this workflow, we evaluated an adjunct AI algorithm (“COVID-19-AI”) that reports High/Medium/Low suspicion to guide whether COVID-19 testing should subsequently be performed. OBJECTIVE To report diagnostic accuracy outcomes of the COVID-19-AI. METHODS We conducted a performance evaluation using a prospectively collected multicenter dataset from 26 Japanese institutions. Patients with suspected influenza or COVID-19 were eligible. The COVID-19-AI algorithm was developed using pharyngeal images combined with routine clinical variables from 2,133 patients, and it produced a three-tier output. Diagnostic performance was assessed in 696 independent patients against RT-PCR-confirmed COVID-19 under two prespecified operating criteria: inclusive (High or Medium = positive; Low = negative) and strict (High = positive; Medium or Low = negative). A subanalysis stratified accuracy by time from symptom onset (12-hour bins to 72 hours). RESULTS Among 696 analyzed participants, 247 were RT-PCR-confirmed COVID-19. Under the inclusive criteria, sensitivity of COVID-19-AI was 93.9% (95% CI 90.4-96.4) and specificity 19.6% (95% CI 16.1-23.5). Under the strict criteria, sensitivity was 24.7% (95% CI 19.6-30.4) and specificity 94.4% (95% CI 92.0-96.3). Across 12-hour onset strata, sensitivity under the inclusive criteria remained ≥92.0% and strict-criteria specificity remained ≥83.3%; no pronounced temporal trend was observed. CONCLUSIONS Embedded within AI-powered pharyngeal camera workflows, a three-tier AI suspicion output enables complementary operating behaviors—high sensitivity to rule out COVID-19 (inclusive criteria) and high specificity to diagnose COVID-19 (strict criteria). Performance stability across onset times suggests robustness to symptom chronology.
- 22 November 2025
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessArtificial Intelligence–Guided Triage for COVID–19 Testing Using Pharyngeal Images (Preprint)
BACKGROUND COVID-19 remains a common cause of acute respiratory illness, yet symptom-based triage poorly discriminates it from other febrile conditions. A recently developed artificial intelligence (AI)-powered pharyngeal camera acquires pharyngeal images and clinical data to assist influenza diagnosis; leveraging this workflow, we evaluated an adjunct AI algorithm (“COVID-19-AI”) that reports High/Medium/Low suspicion to guide whether COVID-19 testing should subsequently be performed. OBJECTIVE To report diagnostic accuracy outcomes of the COVID-19-AI. METHODS We conducted a performance evaluation using a prospectively collected multicenter dataset from 26 Japanese institutions. Patients with suspected influenza or COVID-19 were eligible. The COVID-19-AI algorithm was developed using pharyngeal images combined with routine clinical variables from 2,133 patients, and it produced a three-tier output. Diagnostic performance was assessed in 696 independent patients against RT-PCR-confirmed COVID-19 under two prespecified operating criteria: inclusive (High or Medium = positive; Low = negative) and strict (High = positive; Medium or Low = negative). A subanalysis stratified accuracy by time from symptom onset (12-hour bins to 72 hours). RESULTS Among 696 analyzed participants, 247 were RT-PCR-confirmed COVID-19. Under the inclusive criteria, sensitivity of COVID-19-AI was 93.9% (95% CI 90.4-96.4) and specificity 19.6% (95% CI 16.1-23.5). Under the strict criteria, sensitivity was 24.7% (95% CI 19.6-30.4) and specificity 94.4% (95% CI 92.0-96.3). Across 12-hour onset strata, sensitivity under the inclusive criteria remained ≥92.0% and strict-criteria specificity remained ≥83.3%; no pronounced temporal trend was observed. CONCLUSIONS Embedded within AI-powered pharyngeal camera workflows, a three-tier AI suspicion output enables complementary operating behaviors—high sensitivity to rule out COVID-19 (inclusive criteria) and high specificity to diagnose COVID-19 (strict criteria). Performance stability across onset times suggests robustness to symptom chronology.
- Open Access
- 23 December 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (12) , e38751
Examining the Use of an Artificial Intelligence Model to Diagnose Influenza: Development and Validation Study
Background: The global burden of influenza is substantial. It is a major disease that causes annual epidemics and occasionally, pandemics. Given that influenza primarily infects the upper respiratory system, it may be possible to diagnose influenza infection by applying deep learning to pharyngeal images. Objective: We aimed to develop a deep learning model to diagnose influenza infection using pharyngeal images and clinical information. Methods: We recruited patients who visited clinics and hospitals because of influenza-like symptoms. In the training stage, we developed a diagnostic prediction artificial intelligence (AI) model based on deep learning to predict polymerase chain reaction (PCR)–confirmed influenza from pharyngeal images and clinical information. In the validation stage, we assessed the diagnostic performance of the AI model. In additional analysis, we compared the diagnostic performance of the AI model with that of 3 physicians and interpreted the AI model using importance heat maps. Results: We enrolled a total of 7831 patients at 64 hospitals between November 1, 2019, and January 21, 2020, in the training stage and 659 patients (including 196 patients with PCR-confirmed influenza) at 11 hospitals between January 25, 2020, and March 13, 2020, in the validation stage. The area under the receiver operating characteristic curve for the AI model was 0.90 (95% CI 0.87-0.93), and its sensitivity and specificity were 76% (70%-82%) and 88% (85%-91%), respectively, outperforming 3 physicians. In the importance heat maps, the AI model often focused on follicles on the posterior pharyngeal wall. Conclusions: We developed the first AI model that can accurately diagnose influenza from pharyngeal images, which has the potential to help physicians to make a timely diagnosis.
- 23 December 2022
- Published by JMIR Publications Inc. in Journal of Medical Internet Research
- Vol. 24 (12) , e38751
Open AccessExamining the Use of an Artificial Intelligence Model to Diagnose Influenza: Development and Validation Study
Background: The global burden of influenza is substantial. It is a major disease that causes annual epidemics and occasionally, pandemics. Given that influenza primarily infects the upper respiratory system, it may be possible to diagnose influenza infection by applying deep learning to pharyngeal images. Objective: We aimed to develop a deep learning model to diagnose influenza infection using pharyngeal images and clinical information. Methods: We recruited patients who visited clinics and hospitals because of influenza-like symptoms. In the training stage, we developed a diagnostic prediction artificial intelligence (AI) model based on deep learning to predict polymerase chain reaction (PCR)–confirmed influenza from pharyngeal images and clinical information. In the validation stage, we assessed the diagnostic performance of the AI model. In additional analysis, we compared the diagnostic performance of the AI model with that of 3 physicians and interpreted the AI model using importance heat maps. Results: We enrolled a total of 7831 patients at 64 hospitals between November 1, 2019, and January 21, 2020, in the training stage and 659 patients (including 196 patients with PCR-confirmed influenza) at 11 hospitals between January 25, 2020, and March 13, 2020, in the validation stage. The area under the receiver operating characteristic curve for the AI model was 0.90 (95% CI 0.87-0.93), and its sensitivity and specificity were 76% (70%-82%) and 88% (85%-91%), respectively, outperforming 3 physicians. In the importance heat maps, the AI model often focused on follicles on the posterior pharyngeal wall. Conclusions: We developed the first AI model that can accurately diagnose influenza from pharyngeal images, which has the potential to help physicians to make a timely diagnosis.
- Open Access
Diagnosing Influenza Infection from Pharyngeal Images using Deep Learning: Machine Learning Approach
Background Influenza is a major global burden of disease, causing annual epidemics and occasionally, pandemics. Given that influenza primarily infects the upper respiratory system, influenza infection may be able to be diagnosed by applying deep learning to pharyngeal images. Objective We aimed to develop a deep learning model to diagnose influenza infection using the data on pharyngeal images and clinical information. Methods We recruited patients who visited clinics and hospitals due to influenza-like symptoms. In the training stage, we developed a diagnostic prediction artificial intelligence (AI) model based on deep learning to predict polymerase chain reaction (PCR)-confirmed influenza from pharyngeal images and clinical information. In the validation stage, we assessed the diagnostic performance of the AI model. In the additional analysis, we compared the diagnostic performance of the AI model with that of three physicians, and also interpreted the AI model using the importance heatmaps. Results A total of 7,831 patients were enrolled at 64 hospitals between Nov 1, 2019 and Jan 21, 2020 in the training stage, and 659 patients (including 196 patients with PCR-confirmed influenza) at 11 hospitals between Jan 25, 2020 and Mar 13, 2020 in the validation stage. The area under the receiver operating characteristic curve of the AI model was 0.90 (95% confidence interval, 0.87–0.93), and its sensitivity and specificity were 76% (70–82%) and 88% (85–91%), respectively, outperforming three physicians. In the importance heatmaps, the AI model often focused on follicles on the posterior pharyngeal wall. Conclusions We developed the first AI model that can accurately diagnose influenza from pharyngeal images, which has the potential to assist physicians make timely diagnosis.
Open AccessDiagnosing Influenza Infection from Pharyngeal Images using Deep Learning: Machine Learning Approach
Background Influenza is a major global burden of disease, causing annual epidemics and occasionally, pandemics. Given that influenza primarily infects the upper respiratory system, influenza infection may be able to be diagnosed by applying deep learning to pharyngeal images. Objective We aimed to develop a deep learning model to diagnose influenza infection using the data on pharyngeal images and clinical information. Methods We recruited patients who visited clinics and hospitals due to influenza-like symptoms. In the training stage, we developed a diagnostic prediction artificial intelligence (AI) model based on deep learning to predict polymerase chain reaction (PCR)-confirmed influenza from pharyngeal images and clinical information. In the validation stage, we assessed the diagnostic performance of the AI model. In the additional analysis, we compared the diagnostic performance of the AI model with that of three physicians, and also interpreted the AI model using the importance heatmaps. Results A total of 7,831 patients were enrolled at 64 hospitals between Nov 1, 2019 and Jan 21, 2020 in the training stage, and 659 patients (including 196 patients with PCR-confirmed influenza) at 11 hospitals between Jan 25, 2020 and Mar 13, 2020 in the validation stage. The area under the receiver operating characteristic curve of the AI model was 0.90 (95% confidence interval, 0.87–0.93), and its sensitivity and specificity were 76% (70–82%) and 88% (85–91%), respectively, outperforming three physicians. In the importance heatmaps, the AI model often focused on follicles on the posterior pharyngeal wall. Conclusions We developed the first AI model that can accurately diagnose influenza from pharyngeal images, which has the potential to assist physicians make timely diagnosis.
- Open Access
- 25 November 2021
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 85 (12) , 2248-2251
New Vision, Mission, and Values of the Japanese Circulation Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 25 November 2021
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 85 (12) , 2248-2251
Open AccessNew Vision, Mission, and Values of the Japanese Circulation Society
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.