SKSaho Kameyama

Saho Kameyama

*This is an algorithmically generated author record based on publicly available information.

Saho Kameyama has a total of 4 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Three-Tier Artificial Intelligence Model for COVID-19 Triage Using Pharyngeal Images (Preprint)

    by Sho Okiyama, Tomonori Aoki, Memori Fukuda, Yuji Ariyasu, Saho Kameyama

    Background: SARS-CoV-2 remains a common cause of acute respiratory illness; however, symptom-based triage poorly discriminates it from other febrile conditions. A recently developed artificial intelligence (AI)–powered pharyngeal camera acquires pharyngeal images and clinical data to assist in influenza diagnosis; leveraging this workflow, we evaluated an adjunct AI algorithm (COVID-19-AI) that reports high, medium, or low suspicion to guide whether SARS-CoV-2 testing should subsequently be performed. Objective: This study aimed to report diagnostic accuracy outcomes and clinical utility of the COVID-19-AI as a triage support tool. Methods: We conducted a performance evaluation using a prospectively collected multicenter dataset from 26 Japanese institutions between December 2023 and March 2024. Patients with suspected influenza or COVID-19 were eligible. The COVID-19-AI algorithm, a stacked ensemble of a Swin Transformer and boosting models, was developed using pharyngeal images combined with routine clinical variables from 2133 patients, and it produced a 3-tier output. Classification thresholds were predefined to optimize clinical rule-out and rule-in utilities. Diagnostic performance was assessed in 696 independent patients against centralized reverse transcription polymerase chain reaction–confirmed SARS-CoV-2 infection under 2 prespecified operating criteria: inclusive (high or medium=positive and low=negative) and strict (high=positive and medium or low=negative). A subanalysis stratified accuracy by time from symptom onset (12-hour bins to 72 hours). Results: Among 696 analyzed participants (all Asian), 247 (35.5%) had reverse transcription polymerase chain reaction–confirmed SARS-CoV-2 infection. The COVID-19-AI categorized 12.4% (n=86), 72.8% (n=507), and 14.8% (n=103) patients as high, medium, and low suspicion, respectively. Under the inclusive criteria, sensitivity of COVID-19-AI was 93.9% (95% CI 90.4%‐96.4%), specificity was 19.6% (95% CI 16.1%‐23.5%), and negative predictive value was 85.4% (95% CI 77.6%‐91.3%). Under the strict criteria, sensitivity was 24.7% (95% CI 19.6%‐30.4%), specificity was 94.4% (95% CI 92.0%‐96.3%), and positive predictive value was 70.9% (95% CI 60.7%‐79.8%). Across 12-hour onset strata, sensitivity under the inclusive criteria remained ≥92.0% and specificity under the strict criteria remained ≥83.3%; no pronounced temporal trend was observed. Additionally, an integrated model using both pharyngeal images and clinical variables (area under the receiver operating characteristic curve [AUROC] 0.78) outperformed models using only clinical variables (AUROC 0.75) or images alone (AUROC 0.71); feature importance analysis further confirmed that pharyngeal image information was the most influential individual predictor, providing greater predictive value than any single clinical variable. Conclusions: Embedded within AI-powered pharyngeal camera workflows, a 3-tier AI suspicion output enables complementary operating behaviors—high sensitivity to rule out COVID-19 (inclusive criteria) and high specificity to support immediate infection control measures (strict criteria), although these criteria involve inherent trade-offs with low specificity and low sensitivity, respectively. Performance stability across onset times suggests robustness to symptom chronology, offering a standardized tool for clinical triage.

  • Open Access

    Artificial Intelligence–Guided Triage for COVID–19 Testing Using Pharyngeal Images (Preprint)

    by Sho Okiyama, Tomonori Aoki, Memori Fukuda, Yuji Ariyasu, Saho Kameyama

    BACKGROUND COVID-19 remains a common cause of acute respiratory illness, yet symptom-based triage poorly discriminates it from other febrile conditions. A recently developed artificial intelligence (AI)-powered pharyngeal camera acquires pharyngeal images and clinical data to assist influenza diagnosis; leveraging this workflow, we evaluated an adjunct AI algorithm (“COVID-19-AI”) that reports High/Medium/Low suspicion to guide whether COVID-19 testing should subsequently be performed. OBJECTIVE To report diagnostic accuracy outcomes of the COVID-19-AI. METHODS We conducted a performance evaluation using a prospectively collected multicenter dataset from 26 Japanese institutions. Patients with suspected influenza or COVID-19 were eligible. The COVID-19-AI algorithm was developed using pharyngeal images combined with routine clinical variables from 2,133 patients, and it produced a three-tier output. Diagnostic performance was assessed in 696 independent patients against RT-PCR-confirmed COVID-19 under two prespecified operating criteria: inclusive (High or Medium = positive; Low = negative) and strict (High = positive; Medium or Low = negative). A subanalysis stratified accuracy by time from symptom onset (12-hour bins to 72 hours). RESULTS Among 696 analyzed participants, 247 were RT-PCR-confirmed COVID-19. Under the inclusive criteria, sensitivity of COVID-19-AI was 93.9% (95% CI 90.4-96.4) and specificity 19.6% (95% CI 16.1-23.5). Under the strict criteria, sensitivity was 24.7% (95% CI 19.6-30.4) and specificity 94.4% (95% CI 92.0-96.3). Across 12-hour onset strata, sensitivity under the inclusive criteria remained ≥92.0% and strict-criteria specificity remained ≥83.3%; no pronounced temporal trend was observed. CONCLUSIONS Embedded within AI-powered pharyngeal camera workflows, a three-tier AI suspicion output enables complementary operating behaviors—high sensitivity to rule out COVID-19 (inclusive criteria) and high specificity to diagnose COVID-19 (strict criteria). Performance stability across onset times suggests robustness to symptom chronology.