Joshua S. Engel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joshua S. Engel has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
Michael Markl
Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA; Department of Biomedical Engineering, McCormick School of Engineering, Evanston, IL, 60208, USA
5 shared publicationsBradley D. Allen
Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, 60611, USA
4 shared publications- Bradley D. Allen
Department of Radiology, Northwestern University, Chicago, IL 60611, USA
2 shared publications Mohammed Elbaz
Department of Radiology Feinberg School of Medicine, Northwestern University Chicago Ilinois USA
2 shared publications- Ozden Kilinc
Department of Radiology, Northwestern University, Chicago, IL, USA
2 shared publications S. Chris Malaisrie
Department of Cardiac Surgery, Northwestern Medicine, Chicago, Illinois, USA
2 shared publications
Latest Publications
- Open Access
- 25 June 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (2) , 101928
Operational costs of four-dimensional flow cardiovascular magnetic resonance: A break-even analysis
- 25 June 2025
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 27 (2) , 101928
Open AccessOperational costs of four-dimensional flow cardiovascular magnetic resonance: A break-even analysis
- Open Access
- 3 August 2024
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 26 (2) , 101078
Interval changes in four-dimensional flow-derived in vivo hemodynamics stratify aortic growth in type B aortic dissection patients
- 3 August 2024
- Published by Elsevier in Journal of Cardiovascular Magnetic Resonance
- Vol. 26 (2) , 101078
Open AccessInterval changes in four-dimensional flow-derived in vivo hemodynamics stratify aortic growth in type B aortic dissection patients
- Open Access
- 18 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6202
Aortic Hemodynamics with Accelerated Dual-Venc 4D Flow MRI in Type B Aortic Dissection
The aim of this study is to investigate the applicability of the dual-venc (DV) 4D flow magnetic resonance imaging (MRI) to quantify the complex flow patterns in type B aortic dissection (TBAD). One GRAPPA-accelerated single-venc (SV) and one compressed-sensing (CS) accelerated DV 4D flow MRI sequences are used to scan all subjects, including twelve chronic TBAD patients and two volunteers. The scans are performed twice for the reproducibility assessment of the scan protocols. Voxelwise quantitative flow parameters including kinetic energy (KE), peak velocity (PV), forward and reverse flows (FF, RF) and stasis are calculated. High-venc (HV) data from the DV acquisition are separately analyzed. The scan time reduction by the CS-accelerated DV 4D flow MRI acquisition is 46.4% compared with the SV acquisition. The DV velocity-to-noise ratio (VNR) is higher compared with HV (p = 0.000). No true lumen (TL) parameter shows a significant difference among the acquisition types (p > 0.05). The false lumen (FL) RF is higher in SV compared with the DV acquisition (p = 0.009). The KE is higher (p = 0.038) and stasis is lower (p = 0.01) in HV compared with SV acquisition. All FL parameters except stasis are higher and stasis is lower in HV compared with DV acquisition (p < 0.05). Positive Pearson correlations among the acquisition types in TL and high agreements between the two scans for all acquisition types are observed except HV RF in the FL, which demonstrates a moderate agreement. The CS-accelerated DV 4D flow MRI may have utility in the clinical daily routine with shortened scan times and improved velocity measurements while providing high VNR in TBAD. The observed hemodynamic flow trends are similar between GRAPPA-accelerated SV and CS-accelerated DV 4D flow MRI acquisitions; however, parameters are more impacted by CS-accelerated HV protocol in FL, which may be secondary to the CS regularization effects.
- 18 May 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (10) , 6202
Open AccessAortic Hemodynamics with Accelerated Dual-Venc 4D Flow MRI in Type B Aortic Dissection
The aim of this study is to investigate the applicability of the dual-venc (DV) 4D flow magnetic resonance imaging (MRI) to quantify the complex flow patterns in type B aortic dissection (TBAD). One GRAPPA-accelerated single-venc (SV) and one compressed-sensing (CS) accelerated DV 4D flow MRI sequences are used to scan all subjects, including twelve chronic TBAD patients and two volunteers. The scans are performed twice for the reproducibility assessment of the scan protocols. Voxelwise quantitative flow parameters including kinetic energy (KE), peak velocity (PV), forward and reverse flows (FF, RF) and stasis are calculated. High-venc (HV) data from the DV acquisition are separately analyzed. The scan time reduction by the CS-accelerated DV 4D flow MRI acquisition is 46.4% compared with the SV acquisition. The DV velocity-to-noise ratio (VNR) is higher compared with HV (p = 0.000). No true lumen (TL) parameter shows a significant difference among the acquisition types (p > 0.05). The false lumen (FL) RF is higher in SV compared with the DV acquisition (p = 0.009). The KE is higher (p = 0.038) and stasis is lower (p = 0.01) in HV compared with SV acquisition. All FL parameters except stasis are higher and stasis is lower in HV compared with DV acquisition (p < 0.05). Positive Pearson correlations among the acquisition types in TL and high agreements between the two scans for all acquisition types are observed except HV RF in the FL, which demonstrates a moderate agreement. The CS-accelerated DV 4D flow MRI may have utility in the clinical daily routine with shortened scan times and improved velocity measurements while providing high VNR in TBAD. The observed hemodynamic flow trends are similar between GRAPPA-accelerated SV and CS-accelerated DV 4D flow MRI acquisitions; however, parameters are more impacted by CS-accelerated HV protocol in FL, which may be secondary to the CS regularization effects.
- Open Access
- 6 January 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (3) , 1037-1040
Entry tear hemodynamics using 4D flow MRI in a patient with acute type B aortic dissection
- 6 January 2023
- Published by Elsevier in Radiology Case Reports
- Vol. 18 (3) , 1037-1040
Open AccessEntry tear hemodynamics using 4D flow MRI in a patient with acute type B aortic dissection
- Open Access
- 18 September 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (11) , 3899-3903
Four‐dimensional magnetic resonance after ascending aorta replacement and aortic valve repair with HAART 300 internal annuloplasty ring
The hemispherical aortic annuloplasty reconstructive technology (HAART) is an internal geometric annuloplasty ring designed to restore a natural elliptical shape to the aortic annulus as part of aortic valve repair. We present four‐dimensional flow hemodynamic analysis before and after implementation of the HAART ring in patients undergoing ascending aortic replacement. Aortic hemodynamics over the cardiac cycle were visualized using time‐resolved three‐dimensional pathlines. Velocity streamlines tangent to the time‐resolved velocity vector field were used to demonstrate instantaneous aortic hemodynamics. Peak velocities, forward and retrograde flow were calculated at nine planes placed along the midline of the thoracic aorta. Systolic wall shear stress and peak viscous energy loss over the cardiac cycle were calculated. HAART patients displayed similar or improved flow profiles after surgery when compared to a patient undergoing ascending aortic replacement alone. There may be a trend towards improved flow dynamics in patients undergoing HAART ring implantation.
- 18 September 2022
- Published by Wiley in Journal of Cardiac Surgery
- Vol. 37 (11) , 3899-3903
Open AccessFour‐dimensional magnetic resonance after ascending aorta replacement and aortic valve repair with HAART 300 internal annuloplasty ring
The hemispherical aortic annuloplasty reconstructive technology (HAART) is an internal geometric annuloplasty ring designed to restore a natural elliptical shape to the aortic annulus as part of aortic valve repair. We present four‐dimensional flow hemodynamic analysis before and after implementation of the HAART ring in patients undergoing ascending aortic replacement. Aortic hemodynamics over the cardiac cycle were visualized using time‐resolved three‐dimensional pathlines. Velocity streamlines tangent to the time‐resolved velocity vector field were used to demonstrate instantaneous aortic hemodynamics. Peak velocities, forward and retrograde flow were calculated at nine planes placed along the midline of the thoracic aorta. Systolic wall shear stress and peak viscous energy loss over the cardiac cycle were calculated. HAART patients displayed similar or improved flow profiles after surgery when compared to a patient undergoing ascending aortic replacement alone. There may be a trend towards improved flow dynamics in patients undergoing HAART ring implantation.
- Open Access
- 21 July 2022
- Published by Wiley
Four-Dimensional Magnetic Resonance after Ascending Aorta Replacement and Aortic Valve Repair with HAART 300 Internal Annuloplasty Ring
The hemispherical aortic annuloplasty reconstructive technology (HAART) is an internal geometric annuloplasty ring designed to restore a natural elliptical shape to the aortic annulus as part of aortic valve repair. We present 4D flow hemodynamic analysis before and after implementation of the HAART ring in patients undergoing ascending aortic replacement. HAART patients displayed similar or improved flow profiles when compared to a patient undergoing ascending aortic replacement alone.
- 21 July 2022
- Published by Wiley
Open AccessFour-Dimensional Magnetic Resonance after Ascending Aorta Replacement and Aortic Valve Repair with HAART 300 Internal Annuloplasty Ring
The hemispherical aortic annuloplasty reconstructive technology (HAART) is an internal geometric annuloplasty ring designed to restore a natural elliptical shape to the aortic annulus as part of aortic valve repair. We present 4D flow hemodynamic analysis before and after implementation of the HAART ring in patients undergoing ascending aortic replacement. HAART patients displayed similar or improved flow profiles when compared to a patient undergoing ascending aortic replacement alone.