Linxiao Gong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Linxiao Gong has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Yong Wang
Department of Electrical Engineering, Shanghai Jiaotong University, Shanghai 200240, China
19 shared publications - Junzhong Xu
Shanghai Jiao Tong University
15 shared publications - Lingfeng Jiang
Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
8 shared publications - Jie Chen
Key Laboratory of Control of Power Transmission and Conversion of Ministry of Education, Shanghai Jiao Tong University, Shanghai, China
7 shared publications - Chaofan Cui
Shanghai Jiao Tong University
5 shared publications - Feng Zhang
Shanghai Jiao Tong University
4 shared publications
Latest Publications
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 11780-11794
An Efficient VF-PSD Modulation Scheme for CLLC Resonant Converter Featuring Full/Half-Bridge Compatibility and Optimized Frequency Range
The CLLC converter is an attractive option for battery charging applications due to their bidirectional power flow and soft-switching characteristics. However, the voltage gain curve of the CLLC converter is flat in the buck region, and existing variable-frequency or phase-shift variable-frequency modulation still require a wide switching frequency range, which increases the switching and core losses. To address this issue, a variable frequency - phase shift – duty cycle (VF-PSD) modulation is proposed in this paper. The proposed modulation features narrow frequency range, full ZVS range, and lower RMS current by introducing asymmetric duty cycle control. Notably, when voltage gain M≤0.5, the system automatically switches to half-bridge mode, further decreasing switching loss and conduction loss. A multi-harmonic model is employed to indirectly analyze the time domain characteristics of the CLLC converter under VF-PSD. Then, the optimal combinations of modulation variables are obtained through an offline particle swarm optimization (PSO) algorithm. Finally, the advantages of VF-PSD modulation are verified through a 1-kW CLLC converter experimental prototype.
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (7) , 11780-11794
An Efficient VF-PSD Modulation Scheme for CLLC Resonant Converter Featuring Full/Half-Bridge Compatibility and Optimized Frequency Range
The CLLC converter is an attractive option for battery charging applications due to their bidirectional power flow and soft-switching characteristics. However, the voltage gain curve of the CLLC converter is flat in the buck region, and existing variable-frequency or phase-shift variable-frequency modulation still require a wide switching frequency range, which increases the switching and core losses. To address this issue, a variable frequency - phase shift – duty cycle (VF-PSD) modulation is proposed in this paper. The proposed modulation features narrow frequency range, full ZVS range, and lower RMS current by introducing asymmetric duty cycle control. Notably, when voltage gain M≤0.5, the system automatically switches to half-bridge mode, further decreasing switching loss and conduction loss. A multi-harmonic model is employed to indirectly analyze the time domain characteristics of the CLLC converter under VF-PSD. Then, the optimal combinations of modulation variables are obtained through an offline particle swarm optimization (PSO) algorithm. Finally, the advantages of VF-PSD modulation are verified through a 1-kW CLLC converter experimental prototype.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3758-3772
An Improved DPWM Method Featuring Minimized-Switching-Losses and Reduced-Common-Mode-Voltage in 3L-NPC Converters Over Full Power Factor Range
Modulation strategies of three-level neutral-point-clamped (3L-NPC) converters to suppress switching losses and common-mode (CM) voltage have gained widespread attention. However, existing methods primarily focus on unit power factor (PF) conditions, leading to optimization failure over a wide PF operating range. To address this limitation, this paper proposes a novel discontinuous pulse width modulation (DPWM) strategy that effectively minimizes both switching losses and CM voltage over the full range of leading and lagging PF angles. For switching loss reduction, a new region division method is introduced based on current magnitude boundaries and the modulation index. For peak-to-peak CM-voltage reduction, an optimal combination of clamping phases and voltage levels is analytically derived and systematically analyzed, restricting the peak-to-peak CM voltage to Udc/3 for all PF conditions. Furthermore, a simplified zero-sequence injection flowchart is developed to facilitate the rapid real-time implementation of the algorithm. Comprehensive performance evaluations, including switching losses, CM voltage characteristics, and neutral point NP voltage self-balancing capability, demonstrate the superiority of the proposed method over traditional PWM methods. Finally, simulation and experimental results validate the accuracy and effectiveness of the proposed method.
- 16 April 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 14 (3) , 3758-3772
An Improved DPWM Method Featuring Minimized-Switching-Losses and Reduced-Common-Mode-Voltage in 3L-NPC Converters Over Full Power Factor Range
Modulation strategies of three-level neutral-point-clamped (3L-NPC) converters to suppress switching losses and common-mode (CM) voltage have gained widespread attention. However, existing methods primarily focus on unit power factor (PF) conditions, leading to optimization failure over a wide PF operating range. To address this limitation, this paper proposes a novel discontinuous pulse width modulation (DPWM) strategy that effectively minimizes both switching losses and CM voltage over the full range of leading and lagging PF angles. For switching loss reduction, a new region division method is introduced based on current magnitude boundaries and the modulation index. For peak-to-peak CM-voltage reduction, an optimal combination of clamping phases and voltage levels is analytically derived and systematically analyzed, restricting the peak-to-peak CM voltage to Udc/3 for all PF conditions. Furthermore, a simplified zero-sequence injection flowchart is developed to facilitate the rapid real-time implementation of the algorithm. Comprehensive performance evaluations, including switching losses, CM voltage characteristics, and neutral point NP voltage self-balancing capability, demonstrate the superiority of the proposed method over traditional PWM methods. Finally, simulation and experimental results validate the accuracy and effectiveness of the proposed method.
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1099-1111
A Hybrid ASL/PSC Converter With Oscillation Mitigation Across Switches and Reduced Voltage Stress
In photovoltaic system, high voltage gain DC-DC converters are required. Hybrid active switched inductor (ASL) / passive switched capacitor (PSC) DC-DC converters are suitable for photovoltaic applications due to their high voltage gain characteristics. However, when the two inductors or the two parasitic capacitors of the switches in such ASL/PSC hybrid converters are mismatched, significant voltage oscillation occur across the switches, which increase the switch voltage stress. Additionally, the ground potential difference between the input and output ports is not constant, which increases EMI issues. To address these issues, this paper proposes a novel hybrid ASL/PSC converter. The proposed converter has no switch voltage oscillation and thus reduces the switch voltage stress. Moreover, the proposed converter has a constant ground potential difference. It also exhibits high voltage gain, lower voltage stress across the output diodes, and higher efficiency. To validate the theoretical analysis, a laboratory prototype was built and tested at an input voltage range of 20V-60V, an output voltage of 400V, and a rated power of 200W.
- 26 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Industrial Electronics
- Vol. 7 (3) , 1099-1111
A Hybrid ASL/PSC Converter With Oscillation Mitigation Across Switches and Reduced Voltage Stress
In photovoltaic system, high voltage gain DC-DC converters are required. Hybrid active switched inductor (ASL) / passive switched capacitor (PSC) DC-DC converters are suitable for photovoltaic applications due to their high voltage gain characteristics. However, when the two inductors or the two parasitic capacitors of the switches in such ASL/PSC hybrid converters are mismatched, significant voltage oscillation occur across the switches, which increase the switch voltage stress. Additionally, the ground potential difference between the input and output ports is not constant, which increases EMI issues. To address these issues, this paper proposes a novel hybrid ASL/PSC converter. The proposed converter has no switch voltage oscillation and thus reduces the switch voltage stress. Moreover, the proposed converter has a constant ground potential difference. It also exhibits high voltage gain, lower voltage stress across the output diodes, and higher efficiency. To validate the theoretical analysis, a laboratory prototype was built and tested at an input voltage range of 20V-60V, an output voltage of 400V, and a rated power of 200W.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8105-8119
An Online Safe-Fast Start-Up Strategy for LC -DAB Converter Based on Resonant-Voltage-Limitation
Unlike L-DAB converters, where startup safety primarily focuses on limiting peak inductor current, LC-DAB converters require additional attention due to the overvoltage issue of resonant capacitors, causing immediate dielectric breakdown and permanent damage. Therefore, limiting the peak resonant voltage should be prioritized as a critical condition for ensuring safe startup in LC-DAB converters, which has not yet been effectively solved. To address this issue, a closed-loop safe-fast startup strategy for LC-DAB converters is proposed in this article. By keeping the peak voltage of the resonant capacitor (vrmax) to its allowable maximum during the startup process, the proposed strategy ensures converter safety while maximizing output power, thereby accelerating the startup process. First, a time-domain model of the LC-DAB converter is established through state plane trajectory analysis. Based on this model, the optimal phase shift combination that limits vrmax while maximizing output power is derived. Furthermore, smooth variation of the phase-shift angles and online optimization over a wide voltage and load range can be realized based on real-time sampling of the input and output voltages for the proposed strategy, demonstrating strong engineering applicability. Experimental results show that, compared to conventional startup strategies for LC-DAB converters, the proposed method reduces startup time by up to 73.85% under safe resonant voltage limitation.
- 8 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (5) , 8105-8119
An Online Safe-Fast Start-Up Strategy for LC -DAB Converter Based on Resonant-Voltage-Limitation
Unlike L-DAB converters, where startup safety primarily focuses on limiting peak inductor current, LC-DAB converters require additional attention due to the overvoltage issue of resonant capacitors, causing immediate dielectric breakdown and permanent damage. Therefore, limiting the peak resonant voltage should be prioritized as a critical condition for ensuring safe startup in LC-DAB converters, which has not yet been effectively solved. To address this issue, a closed-loop safe-fast startup strategy for LC-DAB converters is proposed in this article. By keeping the peak voltage of the resonant capacitor (vrmax) to its allowable maximum during the startup process, the proposed strategy ensures converter safety while maximizing output power, thereby accelerating the startup process. First, a time-domain model of the LC-DAB converter is established through state plane trajectory analysis. Based on this model, the optimal phase shift combination that limits vrmax while maximizing output power is derived. Furthermore, smooth variation of the phase-shift angles and online optimization over a wide voltage and load range can be realized based on real-time sampling of the input and output voltages for the proposed strategy, demonstrating strong engineering applicability. Experimental results show that, compared to conventional startup strategies for LC-DAB converters, the proposed method reduces startup time by up to 73.85% under safe resonant voltage limitation.
- 14 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4064-4075
Transient Inrush Current Analysis and Suppression for Grid-Forming Converters Under Grid Faults
Grid-forming (GFM) converters have emerged as essential technologies for ensuring the stability of power systems dominated by renewable energy sources. Nevertheless, their restricted overcurrent capacity may trigger protection during grid faults. While existing studies emphasize the design and optimization of overcurrent mitigation strategies, precise characterization of fault current and dynamic analysis of transient inrush current are still lacking, leading to occurrences of protection malfunction. To bridge this research gap, this article considers the impact of filter parameters and current loop parameters on the equivalent impedance of the converter, and on this basis, establishes a precise fault current characterization model for GFM converters. Based on the model, the key factors influencing inrush current can be analyzed, including voltage amplitude, impedance magnitude, and power angle. Finally, a precise virtual impedance-based inrush current suppression method is proposed, which effectively limits the inrush current to the desired level while ensuring system stability. Both theoretical analysis and experimental results are carried out to validate the robustness and adaptability of the proposed strategy under various grid strengths and grid voltage sags.
- 14 November 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (3) , 4064-4075
Transient Inrush Current Analysis and Suppression for Grid-Forming Converters Under Grid Faults
Grid-forming (GFM) converters have emerged as essential technologies for ensuring the stability of power systems dominated by renewable energy sources. Nevertheless, their restricted overcurrent capacity may trigger protection during grid faults. While existing studies emphasize the design and optimization of overcurrent mitigation strategies, precise characterization of fault current and dynamic analysis of transient inrush current are still lacking, leading to occurrences of protection malfunction. To bridge this research gap, this article considers the impact of filter parameters and current loop parameters on the equivalent impedance of the converter, and on this basis, establishes a precise fault current characterization model for GFM converters. Based on the model, the key factors influencing inrush current can be analyzed, including voltage amplitude, impedance magnitude, and power angle. Finally, a precise virtual impedance-based inrush current suppression method is proposed, which effectively limits the inrush current to the desired level while ensuring system stability. Both theoretical analysis and experimental results are carried out to validate the robustness and adaptability of the proposed strategy under various grid strengths and grid voltage sags.
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 7809-7824
A Multiobjective Optimization Modulation Strategy for Achieving Full-Range ZVS in GaN-Based Single-Stage Onboard Charger
In the pursuit of higher power density and operational efficiency in electric vehicle charging systems, the Boost-type integrated dual active bridge (BI-DAB) converter has garnered significant attention. However, traditional modulation schemes exhibit limited zero-voltage switching (ZVS) ranges and insufficient optimization flexibility, which diminishes efficiency and constrains the practical applications of BI-DAB converters. To address these challenges, this paper proposes a hybrid software-hardware multi-objective optimization modulation scheme designed to extend the ZVS operating range and enhance converter efficiency. A comprehensive ZVS model for the BI-DAB converter is established by which the ZVS conditions are derived. The influence of magnetizing inductance is considered, and a hybrid approach that combines the optimal design of magnetizing inductance and phase-shift optimization enables full-range all-ZVS operation. Additionally, the proposed modulation scheme facilitates seamless mode transitions while effectively achieving power factor correction (PFC) and quasi-optimal current stress conditions. Finally, a GaN-based 2 kW/150 kHz BI-DAB converter prototype was constructed, achieving a peak efficiency of 96.6% and a total harmonic distortion (THD) of 1.5%.
- 10 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 13 (6) , 7809-7824
A Multiobjective Optimization Modulation Strategy for Achieving Full-Range ZVS in GaN-Based Single-Stage Onboard Charger
In the pursuit of higher power density and operational efficiency in electric vehicle charging systems, the Boost-type integrated dual active bridge (BI-DAB) converter has garnered significant attention. However, traditional modulation schemes exhibit limited zero-voltage switching (ZVS) ranges and insufficient optimization flexibility, which diminishes efficiency and constrains the practical applications of BI-DAB converters. To address these challenges, this paper proposes a hybrid software-hardware multi-objective optimization modulation scheme designed to extend the ZVS operating range and enhance converter efficiency. A comprehensive ZVS model for the BI-DAB converter is established by which the ZVS conditions are derived. The influence of magnetizing inductance is considered, and a hybrid approach that combines the optimal design of magnetizing inductance and phase-shift optimization enables full-range all-ZVS operation. Additionally, the proposed modulation scheme facilitates seamless mode transitions while effectively achieving power factor correction (PFC) and quasi-optimal current stress conditions. Finally, a GaN-based 2 kW/150 kHz BI-DAB converter prototype was constructed, achieving a peak efficiency of 96.6% and a total harmonic distortion (THD) of 1.5%.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 14755-14770
Full Range Synchronous Rectification Strategy for LCC Converter With Capacitive Output Filter Based on Accurate Time-Domain Analysis
Synchronous rectification (SR) technology is important for improving the efficiency of resonant converters. Sensorless model-based SR strategy has been popular in recent years while many efforts have been made in LLC resonant converter. However, few researchers focus on the SR strategy for LCC converters. In this article, a sensorless model-based SR strategy is proposed, featuring a closed-form solution for all possible modes of LCC converter with no simplification, which ensures the accuracy of the model. Time domain analysis is carried out and the mode distribution is displayed in this article. Meanwhile, the online operation mode recognition algorithm is incorporated in the proposed algorithm, which makes the SR strategy adaptive over the full switching frequency and load range. Simulations and experiments are conducted to validate the accuracy of the proposed algorithm and component tolerance is analyzed to prove the robustness against parameter errors. Electromagnetic interference analysis and short-circuit simulation are included to improve the practical application value of the converter. Experimental results show that the steady-state SR error is less than 0.4% and the dynamic SR error is about 1%. The efficiency is improved by the proposed SR strategy by 1.3% compared with diode rectification.
- 21 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (10) , 14755-14770
Full Range Synchronous Rectification Strategy for LCC Converter With Capacitive Output Filter Based on Accurate Time-Domain Analysis
Synchronous rectification (SR) technology is important for improving the efficiency of resonant converters. Sensorless model-based SR strategy has been popular in recent years while many efforts have been made in LLC resonant converter. However, few researchers focus on the SR strategy for LCC converters. In this article, a sensorless model-based SR strategy is proposed, featuring a closed-form solution for all possible modes of LCC converter with no simplification, which ensures the accuracy of the model. Time domain analysis is carried out and the mode distribution is displayed in this article. Meanwhile, the online operation mode recognition algorithm is incorporated in the proposed algorithm, which makes the SR strategy adaptive over the full switching frequency and load range. Simulations and experiments are conducted to validate the accuracy of the proposed algorithm and component tolerance is analyzed to prove the robustness against parameter errors. Electromagnetic interference analysis and short-circuit simulation are included to improve the practical application value of the converter. Experimental results show that the steady-state SR error is less than 0.4% and the dynamic SR error is about 1%. The efficiency is improved by the proposed SR strategy by 1.3% compared with diode rectification.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12676-12689
A Safe and Fast Closed-Loop Start-Up Strategy for Triple-Active-Bridge Converters Under DC Microgrid Application
Triple active bridge (TAB) converters are widely adopted in dc microgrids, wherein the safe and fast start-up is a key operational requirement. Due to the integrated topology, it is difficult to establish an online and closed-loop start-up strategy to meet this requirement. A common approach is to operate the TAB converter as the dual active bridge (DAB) converter to simplify the start-up process, leading to insufficient output power and limited start-up speed. To address these issues, a closed-loop start-up strategy with dual single phase-shift (DSPS) modulation tailored for the TAB converter is proposed in this article. Major contributions include three aspects. First, a slope comparison method is proposed to quickly observe the system's maximum current point for safe operation. Second, a novel partial derivative tracing method is proposed to solve optimal phase-shift angles for online control. Finally, a safe, fast, and simplified closed-loop TAB start-up strategy based on DSPS control is developed, which maximizes output power while ensuring safe current limitation. The experimental results verify the effectiveness of the proposed strategy. With DSPS control, the start-up speed can be increased by 34% while maintaining controllable current stress compared to the direct application of the DAB start-up strategy.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 12676-12689
A Safe and Fast Closed-Loop Start-Up Strategy for Triple-Active-Bridge Converters Under DC Microgrid Application
Triple active bridge (TAB) converters are widely adopted in dc microgrids, wherein the safe and fast start-up is a key operational requirement. Due to the integrated topology, it is difficult to establish an online and closed-loop start-up strategy to meet this requirement. A common approach is to operate the TAB converter as the dual active bridge (DAB) converter to simplify the start-up process, leading to insufficient output power and limited start-up speed. To address these issues, a closed-loop start-up strategy with dual single phase-shift (DSPS) modulation tailored for the TAB converter is proposed in this article. Major contributions include three aspects. First, a slope comparison method is proposed to quickly observe the system's maximum current point for safe operation. Second, a novel partial derivative tracing method is proposed to solve optimal phase-shift angles for online control. Finally, a safe, fast, and simplified closed-loop TAB start-up strategy based on DSPS control is developed, which maximizes output power while ensuring safe current limitation. The experimental results verify the effectiveness of the proposed strategy. With DSPS control, the start-up speed can be increased by 34% while maintaining controllable current stress compared to the direct application of the DAB start-up strategy.
- 10 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-15
A Self-Clamping Hybrid Active Switched-Inductor Switched-Capacitor DC-DC Converter With High Voltage Gain and No Voltage Oscillation
High voltage gain dc-dc converters are widely adopted in dc microgrid system. Many hybrid active switched-inductor (ASL) switched-capacitor (SC) dc-dc converters have been proposed due to their outstanding gain characteristics among nonisolated converters. However, resonance between the inductor and the parasitic capacitor of the switch can occur in this type of converter, which leads to significant voltage oscillation across the two switches. As a result, the actual voltage stress across the switches will be much higher than the theoretical value. In this article, a novel self-clamping hybrid ASL-SC converter is proposed. The proposed converter can utilize its inherent self-clamping structure to eliminate the voltage oscillation across the switches, which results in lower voltage stress across the switches. Additionally, the proposed converter also exhibits several intrinsic advantages: high voltage gain, lower voltage stress across the output diodes, higher efficiency, and a constant potential difference between the grounds of its input and output ports. This article describes the comprehensive performance characteristics analysis. Moreover, a detailed comparative performance is carried out with other similar converters. Finally, a 20–60 V/400 V, 50 kHz, 200 W experimental prototype has been established in the laboratory to evaluate the proposed converter.
- 10 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. PP (02780046) , 1-15
A Self-Clamping Hybrid Active Switched-Inductor Switched-Capacitor DC-DC Converter With High Voltage Gain and No Voltage Oscillation
High voltage gain dc-dc converters are widely adopted in dc microgrid system. Many hybrid active switched-inductor (ASL) switched-capacitor (SC) dc-dc converters have been proposed due to their outstanding gain characteristics among nonisolated converters. However, resonance between the inductor and the parasitic capacitor of the switch can occur in this type of converter, which leads to significant voltage oscillation across the two switches. As a result, the actual voltage stress across the switches will be much higher than the theoretical value. In this article, a novel self-clamping hybrid ASL-SC converter is proposed. The proposed converter can utilize its inherent self-clamping structure to eliminate the voltage oscillation across the switches, which results in lower voltage stress across the switches. Additionally, the proposed converter also exhibits several intrinsic advantages: high voltage gain, lower voltage stress across the output diodes, higher efficiency, and a constant potential difference between the grounds of its input and output ports. This article describes the comprehensive performance characteristics analysis. Moreover, a detailed comparative performance is carried out with other similar converters. Finally, a 20–60 V/400 V, 50 kHz, 200 W experimental prototype has been established in the laboratory to evaluate the proposed converter.
- 7 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 7936-7953
Online Reactive Power Suppression Strategy for Triple Active Bridge Converter Based on Dynamic Fundamental Voltage-Balance Modulation
The triple active bridge (TAB) converter presents a significant challenge for efficiency optimization due to its complex model resulting from power coupling between ports and multiple control degrees of freedom. Existing high-precision optimization strategies are often based on complex models and modulation methods, typically relying on offline optimization and online look-up tables during operation, making them difficult to apply widely in practical engineering scenarios. To address these challenges, an online reactive power suppression strategy is proposed, which reduces conduction losses by suppressing reactive power during operation. First, the total reactive power model is established, and a dynamic fundamental voltage-balance modulation (DFVM) strategy is employed to automatically suppress fundamental reactive power. Moreover, the zero-voltage-switching range can also be expanded. To further optimize the total reactive power, an additional degree of freedom (the shared phase-shift coefficient $d_{\text{CP}}$) is introduced into the control strategy, which can be dynamically adjusted based on operating conditions. Furthermore, by analyzing the slopes of $d_{\text{CP}}$ and the outer phase shifts in relation to output power and reactive power, an incremental balance-based iterative optimization method was proposed. This method enables adaptive online calculation of the optimal $d_{\text{CP}}$, thereby enhancing the applicability of the control algorithm. Finally, a 3.3-kW prototype was developed to validate the proposed strategy, achieving a peak efficiency of 95.3%. Under light-load conditions, efficiency improved by 5.13% compared to existing online strategies.
- 7 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (6) , 7936-7953
Online Reactive Power Suppression Strategy for Triple Active Bridge Converter Based on Dynamic Fundamental Voltage-Balance Modulation
The triple active bridge (TAB) converter presents a significant challenge for efficiency optimization due to its complex model resulting from power coupling between ports and multiple control degrees of freedom. Existing high-precision optimization strategies are often based on complex models and modulation methods, typically relying on offline optimization and online look-up tables during operation, making them difficult to apply widely in practical engineering scenarios. To address these challenges, an online reactive power suppression strategy is proposed, which reduces conduction losses by suppressing reactive power during operation. First, the total reactive power model is established, and a dynamic fundamental voltage-balance modulation (DFVM) strategy is employed to automatically suppress fundamental reactive power. Moreover, the zero-voltage-switching range can also be expanded. To further optimize the total reactive power, an additional degree of freedom (the shared phase-shift coefficient $d_{\text{CP}}$) is introduced into the control strategy, which can be dynamically adjusted based on operating conditions. Furthermore, by analyzing the slopes of $d_{\text{CP}}$ and the outer phase shifts in relation to output power and reactive power, an incremental balance-based iterative optimization method was proposed. This method enables adaptive online calculation of the optimal $d_{\text{CP}}$, thereby enhancing the applicability of the control algorithm. Finally, a 3.3-kW prototype was developed to validate the proposed strategy, achieving a peak efficiency of 95.3%. Under light-load conditions, efficiency improved by 5.13% compared to existing online strategies.