LJLingfeng Jiang

Lingfeng Jiang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lingfeng Jiang has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • An Online Safe-Fast Start-Up Strategy for LC -DAB Converter Based on Resonant-Voltage-Limitation

    by Lingfeng Jiang, Minqian Wang, Haiguo Tang, Yuxuan Li, Linxiao Gong, Junzhong Xu, Yong Wang

    Unlike L-DAB converters, where startup safety primarily focuses on limiting peak inductor current, LC-DAB converters require additional attention due to the overvoltage issue of resonant capacitors, causing immediate dielectric breakdown and permanent damage. Therefore, limiting the peak resonant voltage should be prioritized as a critical condition for ensuring safe startup in LC-DAB converters, which has not yet been effectively solved. To address this issue, a closed-loop safe-fast startup strategy for LC-DAB converters is proposed in this article. By keeping the peak voltage of the resonant capacitor (vrmax) to its allowable maximum during the startup process, the proposed strategy ensures converter safety while maximizing output power, thereby accelerating the startup process. First, a time-domain model of the LC-DAB converter is established through state plane trajectory analysis. Based on this model, the optimal phase shift combination that limits vrmax while maximizing output power is derived. Furthermore, smooth variation of the phase-shift angles and online optimization over a wide voltage and load range can be realized based on real-time sampling of the input and output voltages for the proposed strategy, demonstrating strong engineering applicability. Experimental results show that, compared to conventional startup strategies for LC-DAB converters, the proposed method reduces startup time by up to 73.85% under safe resonant voltage limitation.

  • A Safe and Fast Closed-Loop Start-Up Strategy for Triple-Active-Bridge Converters Under DC Microgrid Application

    by Yuxuan Li, Lingfeng Jiang, Ziqian Wang, Linxiao Gong, Junzhong Xu

    Triple active bridge (TAB) converters are widely adopted in dc microgrids, wherein the safe and fast start-up is a key operational requirement. Due to the integrated topology, it is difficult to establish an online and closed-loop start-up strategy to meet this requirement. A common approach is to operate the TAB converter as the dual active bridge (DAB) converter to simplify the start-up process, leading to insufficient output power and limited start-up speed. To address these issues, a closed-loop start-up strategy with dual single phase-shift (DSPS) modulation tailored for the TAB converter is proposed in this article. Major contributions include three aspects. First, a slope comparison method is proposed to quickly observe the system's maximum current point for safe operation. Second, a novel partial derivative tracing method is proposed to solve optimal phase-shift angles for online control. Finally, a safe, fast, and simplified closed-loop TAB start-up strategy based on DSPS control is developed, which maximizes output power while ensuring safe current limitation. The experimental results verify the effectiveness of the proposed strategy. With DSPS control, the start-up speed can be increased by 34% while maintaining controllable current stress compared to the direct application of the DAB start-up strategy.


  • Online Reactive Power Suppression Strategy for Triple Active Bridge Converter Based on Dynamic Fundamental Voltage-Balance Modulation

    by Lingfeng Jiang, Linxiao Gong, Yuxuan Li, Dibin Zhu, Yong Wang

    The triple active bridge (TAB) converter presents a significant challenge for efficiency optimization due to its complex model resulting from power coupling between ports and multiple control degrees of freedom. Existing high-precision optimization strategies are often based on complex models and modulation methods, typically relying on offline optimization and online look-up tables during operation, making them difficult to apply widely in practical engineering scenarios. To address these challenges, an online reactive power suppression strategy is proposed, which reduces conduction losses by suppressing reactive power during operation. First, the total reactive power model is established, and a dynamic fundamental voltage-balance modulation (DFVM) strategy is employed to automatically suppress fundamental reactive power. Moreover, the zero-voltage-switching range can also be expanded. To further optimize the total reactive power, an additional degree of freedom (the shared phase-shift coefficient $d_{\text{CP}}$) is introduced into the control strategy, which can be dynamically adjusted based on operating conditions. Furthermore, by analyzing the slopes of $d_{\text{CP}}$ and the outer phase shifts in relation to output power and reactive power, an incremental balance-based iterative optimization method was proposed. This method enables adaptive online calculation of the optimal $d_{\text{CP}}$, thereby enhancing the applicability of the control algorithm. Finally, a 3.3-kW prototype was developed to validate the proposed strategy, achieving a peak efficiency of 95.3%. Under light-load conditions, efficiency improved by 5.13% compared to existing online strategies.


  • An Ultrafast and Wide-Safe-Range Start-Up Method of DAB Converters With Straightforward Frequency-Phase Closed-Loop Control

    by Linxiao Gong, Yunfeng Peng, Chaofan Cui, Jie Chen, Lingfeng Jiang, Xing Fang, Jian Wang, Junzhong Xu, Yong Wang

    Fast and safe start-up is crucial for the dual-active-bridge (DAB) converters. Conventional closed-loop start-up controls fail to achieve theoretical maximum power output due to manually predefined phase-shift modes, limiting start-up speed and safe operational range. To address these issues, this letter proposes a novel variable frequency plus extended phase-shift (EPS) control. This approach enables ultrafast and wide-safe-range start-up of DAB converters by maximizing power-per-current-stress capability within safety limitations. In addition, sole EPS modulation is required in the proposed control, thus eliminating complex mode transitions and streamlining the start-up process. Experimental results indicate that the proposed control achieves a broader safe start-up range and improves start-up speed by up to 43% under voltage-match condition compared to the state-of-the-art methods.


  • Comprehensive Online Decoupling Strategy for LC -TAB Converters in EVs Considering Voltage Fluctuation During Load Transient

    by Lingfeng Jiang, Yifei Wu, Linxiao Gong, Yuxuan Li, Junzhong Xu, Yong Wang

    Power coupling between the ports is a significant challenge faced by triple-active-bridge (TAB) converters. The existing power decoupling strategies only consider the impact of phase-shift angles on power coupling and compensate only for the phase-shift angles to achieve decoupling power control. While these strategies exhibit good decoupling characteristics under constant-voltage-load condition, the magnetic flux of three port transformers is also closely aligned with port voltages. Under constant-resistance-load or constant-power-load conditions, the decoupling effects of conventional strategies would be deteriorated due to fluctuant port voltages, degrading the applicability. To address the above issue, this article presents a comprehensive online decoupling strategy for the TAB converter with LC resonant cavity, where the coupling effect of phase-shift angles and output voltages are comprehensively considered, allowing for a superior decoupling effect under various load types. Herein, the slopes of coupling factors with respect to the output are analyzed and are compensated to zero to achieve decoupling. Furthermore, the fixed-point iteration method is introduced to simplify the calculation process, enabling online decoupling. Finally, a 1-kW experimental prototype is built to validate the proposed strategy, where, compared with the existing strategy, the power fluctuations caused by coupling have been decreased by an average of 30%.


  • A Hybrid Phase-Frequency Control of Dual Active Bridge Converters for Hold-Up Time Extension in More Electric Aircrafts Applications

    by Linxiao Gong, Yunfeng Peng, Chaofan Cui, Jie Chen, Lingfeng Jiang, Junzhong Xu, Xing Fang, Yong Wang

    Dual active bridge converters are extensively adopted in more electric aircrafts, wherein maintaining a sufficient hold-up time is crucial for air safety. As the current stress in conventional phase-shift controls couples with voltage gain, high-degree voltage gain occurred in the hold-up process would lead to terrible current stress higher than safe limit, which not only heightens the risk of device failure but also shortens the hold-up time due to the potential execution of protective measures. To address such issues, this letter proposes a novel hybrid phase-frequency (HPF) control method, particularly suitable for operations under low input voltage with high inductor currents. The HPF control facilitates the decoupling of the current stress from operation gain, offering advantages such as further optimized and fully regulated current stress, an extended hold-up time and enhanced operational safety. Experimental results show that current stress at full-load can be reduced 56% with HPF control, thereby extending hold-up time by 3 times. Additionally, the reduced current stress under certain power ranges contributes to improved steady-state efficiency


  • A Variable Tertiary DC-Link Voltage Control for Integrated APM in EV Charger Systems Featuring Full ZVS Range

    by Lingfeng Jiang, Linxiao Gong, Junzhong Xu, Jie Chen, Haiguo Tang, Mingzhi Nie, Yong Wang

    The Auxiliary Power Module (APM) can be topologically merged with the on-board charger (OBC) to form a vehicle charging system (VCS) with enhanced power density. While operationally similar to standalone APMs, circuit variations may result in functional differences, especially in the phase-shift full-bridge (PSFB) converter, where the interaction between magnetizing current and resonant current is critical. This paper, therefore, investigates such a specific VCS topology, functioning as a two-stage isolated DC-DC converter for integrated APM, wherein the PSFB converter functions as the front-end and buck converter serves as the back-end. This configuration, however, faces challenges related to hard-switching under light loads, leading to reduced system efficiency and electromagnetic compatibility (EMC) issues. To address these issues, a variable front-stage output voltage strategy is proposed to achieve full-range ZVS operation, enhancing the VCS’s efficiency in driving mode. Herein, only large signals are utilized for calculation to ensure system robustness and stability across all operational stages. Finally, a 1kW VCS prototype is built to confirm these findings, showcasing a peak efficiency of 94.5% and a notable 7% efficiency improvement under light loads.


  • State Plane Feedforward Control for LLC Converter With Geometric Simplification

    by Jie Chen, Lingfeng Jiang, Linxiao Gong, Jiahao Li, Yunfeng Peng, Yong Wang

    This paper proposes a state plane feedforward (SPF) control to improve the dynamic response performance of LLC converters. In contrast to the traditional state-plane-based control, the proposed SPF control aims at the steady state analysis of state plane. The proposed SPF control predicts the switching period under specific operating conditions through state plane analysis with geometric simplification, and feedforward it to the conventional linear controller. The switching period predicted by SPF shows good agreement with the actual switching period. Moreover, because the state plane analysis is geometrically simplified, no complex high-order equations need to be solved, and online computation is available. Meanwhile, the SPF control guarantees greater stability compared with other state plane based nonlinear controls, as a result of no transient control structure switching is required during transient states. Finally, both simulation and experiments are carried out to validate the feasibility of the SPF control, the result demonstrates SPF control features a rapid dynamic response to all types of transient.