Wen Pan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Wen Pan has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Baifeng Sun
China-Pakistan Belt and Road Joint Laboratory on Smart Disaster Prevention of Major Infrastructures, Southeast University, Nanjing 211189, China
2 shared publications - Longfei Zhang
College of Architecture and Civil Engineering, Kunming University, Kunming 650214, China
2 shared publications - Xiang Lan
College of Architecture and Civil Engineering, Kunming University, Kunming 650214, China
2 shared publications - Daohang Wang
Faculty of Public Security and Emergency Management, Kunming University of Science and Technology, Kunming, People’s Republic of China
1 shared publication - Hexian Su
Faculty of Civil Engineering and Mechanics, Kunming University of Science and Technology, Kunming 650500, China
1 shared publication - Kechuan Wu
College of Architecture and Civil Engineering, Kunming University, Kunming 650214, China
1 shared publication
Latest Publications
- Open Access
Theoretical Research and Shaking Table Test on Nominal Aspect Ratio of the Isolated Step-Terrace Structure
With the installation of rubber isolation bearings in the upper and lower ground layers, an isolated step-terrace structure was created. Considering the ultimate bearing capacity of the rubber bearing under tension as the critical condition, a comprehensive framework was established to evaluate the overturning failure mechanisms present in isolated step-terrace structures. The bound of nominal aspect ratio was identified as the principal control index within this framework, which incorporates critical parameters such as height ratio (α), width ratio (β), vertical tensile stiffness to compressive stiffness ratio (γ), seismic coefficient (k), and nominal vertical compressive stress (σ0) to provide a thorough analysis of the structural responses and potential failure scenarios. In order to further investigate this matter, a scaled model of an isolated step-terrace concrete frame structure featuring two dropped layers and a single span within an 8° seismic fortification zone was meticulously crafted at a 1:10 similarity ratio. Subsequently, a series of shaking table tests were conducted to analyze the structural response under seismic excitation. The findings indicate that: utilizing the bound of nominal aspect ratio as a metric to gauge the anti-overturning capacity of isolated step-terrace structures is a justified approach. In instances where the height ratio remains constant, the bound of nominal aspect ratio for both positive and negative overturning trended upward with an increase in the width ratio. Notably, the bound of nominal aspect ratio for positive overturning consistently registered lower values compared to that of the negative overturning, underscoring the heightened susceptibility of step-terrace structures to positive overturning. Moreover, in scenarios characterized by higher height and width ratios, the structural integrity remained unscathed by any overturning effects arising from insufficient tensile strength in rubber bearings. Furthermore, the bound of nominal aspect ratio exhibited an ascending trend as the seismic coefficient, nominal vertical compressive stress, and vertical tensile stiffness to compressive stiffness ratio decreased. The outcomes derived from the shaking table test not only confirm the impressive seismic performance of the structure, but also, by closely examining the instantaneous stress variations within the upper and lower isolation layers of the model, substantiate the existence of a positive overturning hazard in scenarios marked by higher seismic coefficients (k). This observation aligns seamlessly with the theoretical projections, thereby substantiating the efficacy of the structural overturning failure theory through direct empirical verification.
Open AccessTheoretical Research and Shaking Table Test on Nominal Aspect Ratio of the Isolated Step-Terrace Structure
With the installation of rubber isolation bearings in the upper and lower ground layers, an isolated step-terrace structure was created. Considering the ultimate bearing capacity of the rubber bearing under tension as the critical condition, a comprehensive framework was established to evaluate the overturning failure mechanisms present in isolated step-terrace structures. The bound of nominal aspect ratio was identified as the principal control index within this framework, which incorporates critical parameters such as height ratio (α), width ratio (β), vertical tensile stiffness to compressive stiffness ratio (γ), seismic coefficient (k), and nominal vertical compressive stress (σ0) to provide a thorough analysis of the structural responses and potential failure scenarios. In order to further investigate this matter, a scaled model of an isolated step-terrace concrete frame structure featuring two dropped layers and a single span within an 8° seismic fortification zone was meticulously crafted at a 1:10 similarity ratio. Subsequently, a series of shaking table tests were conducted to analyze the structural response under seismic excitation. The findings indicate that: utilizing the bound of nominal aspect ratio as a metric to gauge the anti-overturning capacity of isolated step-terrace structures is a justified approach. In instances where the height ratio remains constant, the bound of nominal aspect ratio for both positive and negative overturning trended upward with an increase in the width ratio. Notably, the bound of nominal aspect ratio for positive overturning consistently registered lower values compared to that of the negative overturning, underscoring the heightened susceptibility of step-terrace structures to positive overturning. Moreover, in scenarios characterized by higher height and width ratios, the structural integrity remained unscathed by any overturning effects arising from insufficient tensile strength in rubber bearings. Furthermore, the bound of nominal aspect ratio exhibited an ascending trend as the seismic coefficient, nominal vertical compressive stress, and vertical tensile stiffness to compressive stiffness ratio decreased. The outcomes derived from the shaking table test not only confirm the impressive seismic performance of the structure, but also, by closely examining the instantaneous stress variations within the upper and lower isolation layers of the model, substantiate the existence of a positive overturning hazard in scenarios marked by higher seismic coefficients (k). This observation aligns seamlessly with the theoretical projections, thereby substantiating the efficacy of the structural overturning failure theory through direct empirical verification.
- Open Access
Study on the Damping Efficiency of a Structure with Additional Viscous Dampers Based on the Shaking Table Test
This study specifically focuses on the damping efficiency of a damped structure with additional viscous dampers. A two-layer steel frame structure with eight sets of viscous dampers is used to conduct a series of seismic simulation shaking table tests, including a non-damped structure without dampers and two damped structures with dampers placed at 1/2 and 1/6 of the beam span, respectively. By conducting these tests, the energy dissipation, force, and displacement of the damper, as well as the parameters of the structure such as floor displacement and acceleration, are obtained. The main damping efficiency indicators of the damped structure are calculated, including the additional damping ratio, inter-story displacement utilization rate, as well as the reduction rate of the vertex displacement and the base shear relative to the non-damped structure. The study shows that the viscous dampers exhibit full hysteresis loops and a strong energy dissipation capacity in the structure. The seismic response of the vertex displacement and base shear in the damped structure is significantly smaller than that in the non-damped structure. Under different seismic levels, including frequent earthquakes, occasional earthquakes, and rare earthquakes, the damping effect of the dampers placed at 1/2 of the beam span is significantly better than that placed at 1/6 of the beam span. For example, the additional damping ratio for the X-direction artificial wave REN is 19% and 11%, 20% and 13%, and 13% and 11%, respectively. The patterns for inter-story displacement utilization ratio, reduction rate of the vertex displacement, and reduction rate of the base shear are similar. The research findings strongly indicate that the damped structure with additional viscous dampers exhibits excellent damping efficiency. In future damping design, designers need to fully consider the placement of viscous dampers within the beam span.
Open AccessStudy on the Damping Efficiency of a Structure with Additional Viscous Dampers Based on the Shaking Table Test
This study specifically focuses on the damping efficiency of a damped structure with additional viscous dampers. A two-layer steel frame structure with eight sets of viscous dampers is used to conduct a series of seismic simulation shaking table tests, including a non-damped structure without dampers and two damped structures with dampers placed at 1/2 and 1/6 of the beam span, respectively. By conducting these tests, the energy dissipation, force, and displacement of the damper, as well as the parameters of the structure such as floor displacement and acceleration, are obtained. The main damping efficiency indicators of the damped structure are calculated, including the additional damping ratio, inter-story displacement utilization rate, as well as the reduction rate of the vertex displacement and the base shear relative to the non-damped structure. The study shows that the viscous dampers exhibit full hysteresis loops and a strong energy dissipation capacity in the structure. The seismic response of the vertex displacement and base shear in the damped structure is significantly smaller than that in the non-damped structure. Under different seismic levels, including frequent earthquakes, occasional earthquakes, and rare earthquakes, the damping effect of the dampers placed at 1/2 of the beam span is significantly better than that placed at 1/6 of the beam span. For example, the additional damping ratio for the X-direction artificial wave REN is 19% and 11%, 20% and 13%, and 13% and 11%, respectively. The patterns for inter-story displacement utilization ratio, reduction rate of the vertex displacement, and reduction rate of the base shear are similar. The research findings strongly indicate that the damped structure with additional viscous dampers exhibits excellent damping efficiency. In future damping design, designers need to fully consider the placement of viscous dampers within the beam span.
- Open Access
Experimental Study on Tenon and Mortise Joints of Wood-Structure Houses Reinforced by Innovative Metal Dampers
To improve the seismic performance of Chinese traditional wood-structure houses, this paper proposes to strengthen their mortise and tenon joints by applying an innovative metal damper. According to the dimensions of the “Yikeyin” wood-structure houses in the Tonghai area of Yunnan Province, two groups of six samples of three types of mortise and tenon joints were manufactured, in which one group was mounted with dampers made of Q235 steels. Subsequently, a low-cycle repeated loading test was conducted to examine the overall behavior of these joints. Various characteristics of seismic performance indexes, such as the moment–rotation hysteresis curve, skeleton curve, stiffness degradation, energy dissipation capacity, residual amount of tenon and the removal before and after reinforcements of straight, penetrated and dovetail tenon joints were analyzed. The test results show that these tenons exhibit good deformation capacity, their hysteresis curves became fuller and their “pinch” effects were significantly reduced, all after their joints became strengthened, indicating that their joint slips were reduced during the loading processes and their residual amounts of tenon removals were under effective control. Compared with the blank group, the joint stiffness was substantially improved, and the increase in the reverse stiffness turned greater than that of the positive stiffness at each stage of loading, while the degradation curve of the whole joint stiffness became steeper. After mounting the dampers, the bearing capacity and energy dissipation of the joints were significantly improved, the equivalent viscous damping coefficients of the straight and penetrated tenon joints were increased, but that of the dovetail joint was slightly reduced. These study results can provide a reference for the reinforcement and protection of traditional wood-structure houses.
Open AccessExperimental Study on Tenon and Mortise Joints of Wood-Structure Houses Reinforced by Innovative Metal Dampers
To improve the seismic performance of Chinese traditional wood-structure houses, this paper proposes to strengthen their mortise and tenon joints by applying an innovative metal damper. According to the dimensions of the “Yikeyin” wood-structure houses in the Tonghai area of Yunnan Province, two groups of six samples of three types of mortise and tenon joints were manufactured, in which one group was mounted with dampers made of Q235 steels. Subsequently, a low-cycle repeated loading test was conducted to examine the overall behavior of these joints. Various characteristics of seismic performance indexes, such as the moment–rotation hysteresis curve, skeleton curve, stiffness degradation, energy dissipation capacity, residual amount of tenon and the removal before and after reinforcements of straight, penetrated and dovetail tenon joints were analyzed. The test results show that these tenons exhibit good deformation capacity, their hysteresis curves became fuller and their “pinch” effects were significantly reduced, all after their joints became strengthened, indicating that their joint slips were reduced during the loading processes and their residual amounts of tenon removals were under effective control. Compared with the blank group, the joint stiffness was substantially improved, and the increase in the reverse stiffness turned greater than that of the positive stiffness at each stage of loading, while the degradation curve of the whole joint stiffness became steeper. After mounting the dampers, the bearing capacity and energy dissipation of the joints were significantly improved, the equivalent viscous damping coefficients of the straight and penetrated tenon joints were increased, but that of the dovetail joint was slightly reduced. These study results can provide a reference for the reinforcement and protection of traditional wood-structure houses.