Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Abual Hassan has a total of 34 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Energy distance approach for the condition monitoring of multi turbines using distributional studies.

    by Debela Alema Teklemariyem, Syed Nasir Hussain Razvi, Abu A. Hassan, Wieslaw Jerzy Staszewski, Phong B. Dao

    This study presents the energy distance non-parametric approach for condition monitoring of multiple wind turbines within the same wind farm. The main objective of this work is to monitor the performance of wind turbines by comparing them against each other within the same farm. Traditional methods often rely on parametric assumptions, including normality, which are rarely satisfied in real-world applications. In contrast, the energy distance approach is fully non-parametric, does not assume normality, and is effective for distributions of any shape or location. It enables comparison at the distributional level without requiring explicit assumptions. To validate the proposed approach, SCADA data from a wind farm in Portugal was analyzed. Four wind turbines, including the unit operating in a fault condition, were comparatively analyzed using multiple parameters through the application of the Energy Distance method. The results demonstrate that this method provides a robust means of detecting faults earlier than traditional approaches, as faulty turbines show clear deviations from healthy turbine states. The analysis considered multiple parameters, including generated power, wind speed, hydraulic oil temperature, gearbox oil temperature, generator bearing temperature 2, gearbox bearing temperature, and others. Overall, the results of the study clearly indicate that when comparing the four wind turbines using the energy distance method, the turbine with a fault exhibits a significantly larger energy distance relative to all other turbines. This distinct difference effectively distinguishes the faulty turbine from the healthy ones. These findings confirm that the energy distance approach, based on distributional comparisons, is a robust, efficient, and easily interpretable method for the condition monitoring of wind turbines.

  • Individual Modelling of Intricate Nonstationary Time Series Using Cointegration Analysis for Faut Detection and Condition Monitoring

    by Syed Nasir Hussain Razvi, Debela Alema Teklemariyem, Abu A. Hassan, Wieslaw Jerzy Staszewski, Phong B. Dao

    Contemporary industrial processes typically operate with time-varying statistical properties. Specifically, these processes exhibit fluctuating mean, variance, and covariance values. Such variation leads to the emergence of nonstationary characteristics in these processes. These rapidly changing statistical properties result in process variables displaying unexpected patterns that fall outside the assumptions underlying classical monitoring methods. This major difference is particularly problematic when working with nonstationary data that has varying levels of integration (which means how many times a series needs to be differenced to become stationary, noted as I(d), where d can be 0, 1, or 2) in the process variables, making standard methods much less useful. To address this challenge, an individual model of an intricate nonstationary time series using cointegration is proposed. Cointegration, a technique that can address non-stationarity. However, it demands that the variables under investigation share at least a common trend and the same integration order. The approach begins by classifying variables according to their order of integration using the Augmented Dickey-Fuller (ADF) test and subsequently identifies long-run equilibrium relationships among these variables within each group. By capturing the inherent cointegration structure, it becomes possible to develop more robust monitoring statistics that are sensitive to process deviations, even in the presence of complex, nonstationary behaviours. The proposed approach has been validated through a numerical simulation by generating the synthetic time series data with various fault conditions. Overall, the findings and comparisons with two well-established techniques, principal component analysis (PCA) and dynamic principal component analysis (DPCA), demonstrate that the proposed approach provides superior monitoring performance, particularly for variables characterised by a higher order of integration.

  • Open Access

    Physics-Driven Integration of Trend Monitoring and Change Point Detection for Wind Turbine Blade SHM: An Experimental Validation

    by Abu A. Hassan, Nasir Hussain Razvi Syed, Debela Alema Teklemariyem, Phong B. Dao

    As wind turbines operate under highly stochastic environmental and operational conditions (EOCs), robust Condition Monitoring (CM) strategies are essential for minimizing unscheduled downtime. Recent research suggests that integrating Trend Monitoring (TM) with Change Point Detection (CPD) can enhance diagnostic sensitivity by capturing both monotonic degradation and discrete structural shifts. This study provides the first experimental validation of an integrated TM–CPD framework using vibration data from wind turbine blades. Two laboratory case studies were conducted: leading-edge erosion (representing quasi-static surface degradation) and twist misalignment (representing a dynamic aerodynamic fault). For erosion, TM via Discrete Wavelet Transform (DWT) energy coefficients in the mid-frequency bands (3rd to 5th levels) showed a consistent increase (+34–45%), effectively characterizing the degradation trend. Bayesian Online Change Point Detection (BOCPD) provided no additional gain, confirming that TM is sufficient for steady-state faults. Conversely, for twist misalignment, Short-Time Fast Fourier Transform (STFT) revealed gradual spectral drifting, while BOCPD applied to the spectral centroid yielded a sharp, localized probability peak corresponding to the onset of aerodynamic imbalance. This integrated approach significantly improves the Probability of Detection (PoD) for dynamic faults. From an industrial perspective, this hybrid methodology mitigates the risk of catastrophic failure and optimizes the Levelized Cost of Energy (LCOE) by transitioning from reactive to predictive maintenance. Environmentally, the early detection of aerodynamic faults ensures optimal power curve performance, maximizing carbon-free energy yield and extending the structural fatigue life of the turbine assembly. This work establishes an evidence-based guideline: CPD is critical for faults inducing spectral instability, while TM suffices for smooth, monotonic degradation.

  • Open Access

    Multi-order nonstationarity-driven cointegration method for wind turbine generator condition monitoring and anomaly detection

    by Nasir H. R. Syed, Debela A. Teklemariyem, Abu Al Hassan, Phong B. Dao

    Wind turbine Supervisory Control and Data Acquisition (SCADA) data are inherently nonstationary due to changing environmental conditions, operating regimes, and component aging, while emerging faults can further alter the statistical stationarity behavior of monitoring parameters. These characteristics make reliable condition monitoring and fault detection particularly challenging. This paper proposes a novel multi-order nonstationarity-driven cointegration framework for wind turbine monitoring that explicitly accounts for variables with different levels of nonstationarity. Using Johansen’s cointegration method, long-term equilibrium relationships are identified from the training data, and normalized cointegrating vectors are estimated. Cointegration residuals are then obtained by projecting SCADA data onto these vectors. Stationary residuals from the training set are used to establish control limits, while monitoring statistics, based on the Mahalanobis distance, are calculated using stationary residuals from the testing set. An alarm is triggered when these statistics exceed the defined threshold. The proposed approach is validated through a numerical study involving simulated faults in time series with different nonstationarity levels, followed by application to real SCADA data from a commercial wind turbine. Results demonstrate that the method effectively handles multi-order nonstationarity and enables accurate early detection of generator faults. The proposed framework detected the faults approximately 40 min and 33 h and 7 min earlier than the actual occurrence of generator bearing damage on August 20, 2017, at 06:08 and generator damage on August 21, 2017, at 14:47. The early detection capability highlights its potential to improve the robustness and reliability of wind turbine condition monitoring systems compared to principal component analysis and partial least squares.

  • Top Cited Papers
    Open Access

    An integrated change-point detection framework for wind turbine monitoring and fault diagnosis using SCADA data

    by Abu Al Hassan, Abdelkareem Abdallah Abdelkareem Jebreel, Krzysztof Kijanowski, Cuong Duc Dao, Phong Ba Dao


  • Open Access

    Integrating Trend Monitoring and Change Point Detection for Wind Turbine Blade Diagnostics: A Physics-Driven Evaluation of Erosion and Twist Faults

    by Abu Al Hassan, Nasir Hussain Razvi Syed, Debela Alema Teklemariyem, Phong Ba Dao

    Robust condition monitoring of wind turbine blades is essential for reducing downtime and maintenance costs, particularly under variable operating conditions. While recent studies suggest that combining trend monitoring (TM) with change point detection (CPD) can improve diagnostic performance, it remains unclear whether such integration is beneficial for all fault types. This study experimentally evaluates the integration of TM and CPD using vibration data from a laboratory-scale wind turbine for two representative blade faults: leading-edge erosion and twist misalignment. For the erosion case, discrete wavelet transform (DWT) energy features exhibit a clear and persistent increase in mid-frequency content, with energy deviations of approximately 34–45% relative to the healthy state. However, Bayesian Online Change Point Detection (BOCPD) does not reveal distinct change points, indicating that CPD provides limited additional value for gradual, steady-state degradation. In contrast, for twist misalignment, the short-time Fast Fourier Transform (FFT) features reveal dynamic spectral redistribution, and CPD applied to spectral centroid trends produces a sharp, localized detection signature. These results demonstrate that integrating TM with CPD significantly enhances fault detectability for dynamic, instability-driven faults, while TM alone is sufficient for smooth, steady-state degradation. This study provides an evidence-based guideline for selectively integrating CPD into wind turbine blade condition monitoring systems based on fault physics.


  • Open Access

    Bridging Data and Diagnostics: A Systematic Review and Case Study on Integrating Trend Monitoring and Change Point Detection for Wind Turbines

    by Abu Al Hassan, Phong Ba Dao

    Wind turbines face significant operational challenges due to their complex electromechanical systems, exposure to harsh environmental conditions, and high maintenance costs. Reliable structural health monitoring and condition monitoring are therefore essential for early fault detection, minimizing downtime, and optimizing maintenance strategies. Traditional approaches typically rely on either Trend Monitoring (TM) or Change Point Detection (CPD). TM methods track the long-term behaviour of process parameters, using statistical analysis or machine learning (ML) to identify abnormal patterns that may indicate emerging faults. In contrast, CPD techniques focus on detecting abrupt changes in time-series data, identifying shifts in mean, variance, or distribution, and providing accurate fault onset detection. While each approach has strengths, they also face limitations: TM effectively identifies fault type but lacks precision in timing, while CPD excels at locating fault occurrence but lacks detailed fault classification. This review critically examines the integration of TM and CPD methods for wind turbine diagnostics, highlighting their complementary strengths and weaknesses through an analysis of widely used TM techniques (e.g., Fast Fourier Transform, Wavelet Transform, Hilbert–Huang Transform, Empirical Mode Decomposition) and CPD methods (e.g., Bayesian Online Change Point Detection, Kullback–Leibler Divergence, Cumulative Sum). By combining both approaches, diagnostic accuracy can be enhanced, leveraging TM’s detailed fault characterization with CPD’s precise fault timing. The effectiveness of this synthesis is demonstrated in a case study on wind turbine blade fault diagnosis. Results shows that TM–CPD integration enhances early detection through coupling vibration and frequency trend analysis with robust statistical validation of fault onset.


  • Open Access

    Joint Phase Shift Design and Resource Management for a Non-Orthogonal Multiple Access-Enhanced Internet of Vehicle Assisted by an Intelligent Reflecting Surface-Equipped Unmanned Aerial Vehicle

    by Lijuan Wang, Yixin He, Bin Chen, Abual Hassan, Dawei Wang, Lina Yang, Fanghui Huang

    This paper integrates intelligent reflecting surfaces (IRS) with unmanned aerial vehicles (UAV) to enhance the transmission performance of the Internet of Vehicles (IoV) through non-orthogonal multiple access (NOMA). It focuses on strengthening the signals from cell edge vehicles (CEVs) to the base station by optimizing the wireless propagation environment via an IRS-equipped UAV. The primary goal is to maximize the sum data rate of CEVs while satisfying the constraint of the successive interference cancellation (SIC) decoding threshold. The challenge lies in the non-convex nature of jointly considering the power control, subcarrier allocation, and phase shift design, making the problem difficult to optimally solve. To address this, the problem is decomposed into two independent subproblems, which are then solved iteratively. Specifically, the optimal phase shift design is achieved using the deep deterministic policy gradient (DDPG) algorithm. Furthermore, the graph theory is applied to determine the subcarrier allocation policy and derive a closed-form solution for optimal power control. Finally, the simulation results show that the proposed joint phase shift and resource management scheme significantly enhances the sum data rate compared to the state-of-the-art schemes, thereby demonstrating the benefits of integrating the IRS-equipped UAV into NOMA-enhanced IoV.


  • Open Access

    Analyzing Role of Artificial Intelligence in Project Management and Investment Risk: A CiteSpace Insight

    by Shuang Lai, Shaoqian Zhang, Abual Hassan, Ray Tahir Mushtaq

    The current research work explores the artificial intelligence and sustainability impact on investment risk and project management based on trend analysis from 2017 to 2022. Deakin University; the University of London or other key contributors and institutions that contribute to this field is identified by a rigorous analysis of one hundred nineteen articles from Web of Science. In it, a considerable part of the world is shown with meaningful contributions from China, Korea and the United States. This research presents the changing AI phenomenon in risk management for investments and especially notes that there is increasing connection with sustainability. The results of this work emphasize the role of AI in renovating traditional risk paradigms and suggest appropriate international cooperation. The study thus not only uncovers the current state of knowledge but also positions itself as a starting point for future research in AI-driven investment risk management, providing valuable perspectives to both science and practice.


  • Open Access

    A Survey on Air-to-Sea Integrated Maritime Internet of Things: Enabling Technologies, Applications, and Future Challenges

    by Shulei Liu, Lijun Zhu, Fanghui Huang, Abual Hassan, Dawei Wang, Yixin He

    Future generation communication systems are exemplified by 5G and 6G wireless technologies, and the utilization of integrated air-to-sea (A2S) communication infrastructure is employed to extend network coverage and enhance data throughput to support data-driven maritime applications. These ground-breaking techniques have promoted the rapid development of the maritime internet of things (MIoT). In particular, the integration of air base stations (ABSs) in the MIoT can achieve broadband, low-delay, and reliable wireless transmissions. Considering the potential of ABS-enabled communications, this survey presents the state of the art in the A2S integrated MIoT. More specifically, relevant A2S integrated MIoT architectures are discussed together with the role of their building blocks. Next, we introduce the enabling technologies, including the sensor, communication, data processing and storage, and security and privacy protection techniques. Then, resource allocation, cloud/edge computing and caching, routing protocols, and spatial location optimization in the maritime environment are discussed and grouped based on their performance targets. Additionally, we also show the potential applications of the A2S integrated MIoT in marine environment monitoring, traffic, navigation safety, and resources management. Finally, several future challenges in the area of the A2S integrated MIoT are given, related to the technical security, reliability, and energy efficiency, etc.