Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Nasir Hussain Razvi Syed has a total of 5 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hybrid Energy Distance and Permutation Testing for Vibration-Based Wind Turbine Blade Fault Diagnosis

    by Debela A. Teklemariyem, Nasir H. R. Syed, Wieslaw J. Staszewski, Phong B. Dao

    Wind turbine blade failure diagnosis is of critical importance, as the inability to reliably detect such faults can result in substantial financial losses, prolonged downtime, extensive repair activities, as well as increased operation and maintenance costs. This paper introduces a new application of energy distance and permutation testing for wind turbine blade fault diagnosis based on vibration data analysis. The proposed approach combines a non-parametric energy distance and permutation testing for the identification and characterization of blade faults in wind turbines. Unlike conventional approaches, this method does not require the assumption of a normal data distribution, which is particularly important when analysing vibration signals, as such data often deviates from normality. The approach is also robust against the presence of outliers. The energy distance metric is employed to classify the blade condition of the wind turbine and to investigate subtle changes in blade behaviour by comparing healthy and corresponding faulty states while considering the entire data distribution rather than conventional summary statistics. In the second stage, a permutation test is applied to statistically validate the energy distance results via p-values. The proposed method is validated using experimental vibration datasets representing healthy and faulty blade conditions, including cracked, eroded, twisted, and imbalanced faults. These datasets are analysed under varying wind speed conditions to assess the robustness of the proposed method under different operating conditions. In the second stage, the permutation test confirms the statistical significance of the detected distributional differences, providing additional confidence in the diagnostic results. The findings indicate that the combined use of energy distance and permutation testing effectively identifies and detects the faults from the healthy blade behaviour across two different wind speed conditions. The findings of this study indicate the potential of the proposed approach as a simple, robust, and interpretable solution for wind turbine blade fault diagnosis based on vibration data analysis.


  • Open Access

    A Dual-Scheme Cointegration Framework for Condition Monitoring and Fault Detection Using Non-Joint and Mixed-Order Time Series

    by Nasir Hussain Razvi Syed, Debela Alema Teklemariyem, Wieslaw Jerzy Staszewski, Phong B. Dao

    Recent years have seen growing faith in data-driven tools for condition monitoring and fault detection, a trend accelerated further by advances in artificial intelligence. In many industrial systems typical examples like chemical plants and wind-energy installations—the underlying process variables do not behave in a stable or predictable manner. Their statistical features shift over time, and conventional monitoring methods which assume an essentially stationary assumption, often struggle to handle high-dimensional signals. Much of the difficulty stems from the fact that several variables move together over long periods but differ in their degree of non-stationarity. To deal with this challenge, two monitoring strategies are designed to react reliably to deviations even when the data show complicated stochastic behaviour. The framework consists of two cointegration-based schemes. Scheme 1 treats all series jointly (i.e., mixed order), regardless of their integration order, while Scheme 2, first separates them into (0), (1), and (2) groups using the augmented DickeyFuller (ADF) test and then each group fed to cointegration model individually. In both cases, the residuals serve as indicators. Monitoring statistics are estimated based on the Mahalanobis Distance (MD), utilizing residuals from testing set; the control limit (CL) is computed based on the Kernel Density Estimation (KDE) utilizing residuals from training set. Any deviation of monitoring statistics crossing the CL highlights the abnormal conditions in the system. Numerical case studies demonstrate the efficacy of non-joint cointegration-based monitoring (Scheme 2), which provides a flexible and computationally efficient method for monitoring non-stationary processes. In comparison to traditional PCA and CA-based Schemes, the Scheme 2 framework has better performance with a lower false alarm.

  • Open Access

    Energy distance approach for the condition monitoring of multi turbines using distributional studies.

    by Debela Alema Teklemariyem, Syed Nasir Hussain Razvi, Abu A. Hassan, Wieslaw Jerzy Staszewski, Phong B. Dao

    This study presents the energy distance non-parametric approach for condition monitoring of multiple wind turbines within the same wind farm. The main objective of this work is to monitor the performance of wind turbines by comparing them against each other within the same farm. Traditional methods often rely on parametric assumptions, including normality, which are rarely satisfied in real-world applications. In contrast, the energy distance approach is fully non-parametric, does not assume normality, and is effective for distributions of any shape or location. It enables comparison at the distributional level without requiring explicit assumptions. To validate the proposed approach, SCADA data from a wind farm in Portugal was analyzed. Four wind turbines, including the unit operating in a fault condition, were comparatively analyzed using multiple parameters through the application of the Energy Distance method. The results demonstrate that this method provides a robust means of detecting faults earlier than traditional approaches, as faulty turbines show clear deviations from healthy turbine states. The analysis considered multiple parameters, including generated power, wind speed, hydraulic oil temperature, gearbox oil temperature, generator bearing temperature 2, gearbox bearing temperature, and others. Overall, the results of the study clearly indicate that when comparing the four wind turbines using the energy distance method, the turbine with a fault exhibits a significantly larger energy distance relative to all other turbines. This distinct difference effectively distinguishes the faulty turbine from the healthy ones. These findings confirm that the energy distance approach, based on distributional comparisons, is a robust, efficient, and easily interpretable method for the condition monitoring of wind turbines.

  • Individual Modelling of Intricate Nonstationary Time Series Using Cointegration Analysis for Faut Detection and Condition Monitoring

    by Syed Nasir Hussain Razvi, Debela Alema Teklemariyem, Abu A. Hassan, Wieslaw Jerzy Staszewski, Phong B. Dao

    Contemporary industrial processes typically operate with time-varying statistical properties. Specifically, these processes exhibit fluctuating mean, variance, and covariance values. Such variation leads to the emergence of nonstationary characteristics in these processes. These rapidly changing statistical properties result in process variables displaying unexpected patterns that fall outside the assumptions underlying classical monitoring methods. This major difference is particularly problematic when working with nonstationary data that has varying levels of integration (which means how many times a series needs to be differenced to become stationary, noted as I(d), where d can be 0, 1, or 2) in the process variables, making standard methods much less useful. To address this challenge, an individual model of an intricate nonstationary time series using cointegration is proposed. Cointegration, a technique that can address non-stationarity. However, it demands that the variables under investigation share at least a common trend and the same integration order. The approach begins by classifying variables according to their order of integration using the Augmented Dickey-Fuller (ADF) test and subsequently identifies long-run equilibrium relationships among these variables within each group. By capturing the inherent cointegration structure, it becomes possible to develop more robust monitoring statistics that are sensitive to process deviations, even in the presence of complex, nonstationary behaviours. The proposed approach has been validated through a numerical simulation by generating the synthetic time series data with various fault conditions. Overall, the findings and comparisons with two well-established techniques, principal component analysis (PCA) and dynamic principal component analysis (DPCA), demonstrate that the proposed approach provides superior monitoring performance, particularly for variables characterised by a higher order of integration.

  • Open Access

    Physics-Driven Integration of Trend Monitoring and Change Point Detection for Wind Turbine Blade SHM: An Experimental Validation

    by Abu A. Hassan, Nasir Hussain Razvi Syed, Debela Alema Teklemariyem, Phong B. Dao

    As wind turbines operate under highly stochastic environmental and operational conditions (EOCs), robust Condition Monitoring (CM) strategies are essential for minimizing unscheduled downtime. Recent research suggests that integrating Trend Monitoring (TM) with Change Point Detection (CPD) can enhance diagnostic sensitivity by capturing both monotonic degradation and discrete structural shifts. This study provides the first experimental validation of an integrated TM–CPD framework using vibration data from wind turbine blades. Two laboratory case studies were conducted: leading-edge erosion (representing quasi-static surface degradation) and twist misalignment (representing a dynamic aerodynamic fault). For erosion, TM via Discrete Wavelet Transform (DWT) energy coefficients in the mid-frequency bands (3rd to 5th levels) showed a consistent increase (+34–45%), effectively characterizing the degradation trend. Bayesian Online Change Point Detection (BOCPD) provided no additional gain, confirming that TM is sufficient for steady-state faults. Conversely, for twist misalignment, Short-Time Fast Fourier Transform (STFT) revealed gradual spectral drifting, while BOCPD applied to the spectral centroid yielded a sharp, localized probability peak corresponding to the onset of aerodynamic imbalance. This integrated approach significantly improves the Probability of Detection (PoD) for dynamic faults. From an industrial perspective, this hybrid methodology mitigates the risk of catastrophic failure and optimizes the Levelized Cost of Energy (LCOE) by transitioning from reactive to predictive maintenance. Environmentally, the early detection of aerodynamic faults ensures optimal power curve performance, maximizing carbon-free energy yield and extending the structural fatigue life of the turbine assembly. This work establishes an evidence-based guideline: CPD is critical for faults inducing spectral instability, while TM suffices for smooth, monotonic degradation.

  • Open Access

    Multi-order nonstationarity-driven cointegration method for wind turbine generator condition monitoring and anomaly detection

    by Nasir H. R. Syed, Debela A. Teklemariyem, Abu Al Hassan, Phong B. Dao

    Wind turbine Supervisory Control and Data Acquisition (SCADA) data are inherently nonstationary due to changing environmental conditions, operating regimes, and component aging, while emerging faults can further alter the statistical stationarity behavior of monitoring parameters. These characteristics make reliable condition monitoring and fault detection particularly challenging. This paper proposes a novel multi-order nonstationarity-driven cointegration framework for wind turbine monitoring that explicitly accounts for variables with different levels of nonstationarity. Using Johansen’s cointegration method, long-term equilibrium relationships are identified from the training data, and normalized cointegrating vectors are estimated. Cointegration residuals are then obtained by projecting SCADA data onto these vectors. Stationary residuals from the training set are used to establish control limits, while monitoring statistics, based on the Mahalanobis distance, are calculated using stationary residuals from the testing set. An alarm is triggered when these statistics exceed the defined threshold. The proposed approach is validated through a numerical study involving simulated faults in time series with different nonstationarity levels, followed by application to real SCADA data from a commercial wind turbine. Results demonstrate that the method effectively handles multi-order nonstationarity and enables accurate early detection of generator faults. The proposed framework detected the faults approximately 40 min and 33 h and 7 min earlier than the actual occurrence of generator bearing damage on August 20, 2017, at 06:08 and generator damage on August 21, 2017, at 14:47. The early detection capability highlights its potential to improve the robustness and reliability of wind turbine condition monitoring systems compared to principal component analysis and partial least squares.

  • Open Access

    Nonstationarity-Driven Cointegration Analysis for Condition Monitoring and Fault Diagnosis of Industrial Processes

    by Nasir Razvi, Debela Alema, Wieslaw J. Staszewski, Phong B. Dao

    Modern industrial processes frequently exhibit strong nonstationary behaviour, where process variables evolve with time-varying statistical properties. Such characteristics pose major challenges for reliable condition monitoring and fault diagnosis, as conventional multivariate statistical process monitoring (MSPM) techniques are primarily designed for stationary data and therefore struggle to capture long-term dynamics in nonstationary systems. To address this limitation, this paper proposes a nonstationarity-driven cointegration framework for industrial process monitoring and fault detection. The novelty of the approach lies in explicitly accounting for variables with different orders of integration. First, the Augmented Dickey–Fuller (ADF) test is used to classify process variables according to their integration order. Johansen’s cointegration method is then applied to extract long-run equilibrium relationships within each group, transforming nonstationary measurements into stationary cointegration residuals. These residuals are subsequently monitored using Mahalanobis Distance–based statistics, while control limits are established from healthy operating data. Faults are detected when monitoring statistics exceed the predefined threshold. The proposed framework is validated through two case studies: a numerical simulation involving multi-order variables with induced faults, and the Tennessee Eastman benchmark industrial process. Results demonstrate that the method effectively captures hidden long-term dependencies and enables reliable fault detection under complex nonstationary operating conditions. Overall, the proposed approach provides a robust and interpretable alternative to conventional MSPM methods, offering improved monitoring performance for modern industrial systems characterized by heterogeneous and evolving process dynamics.

  • Open Access

    Integrating Trend Monitoring and Change Point Detection for Wind Turbine Blade Diagnostics: A Physics-Driven Evaluation of Erosion and Twist Faults

    by Abu Al Hassan, Nasir Hussain Razvi Syed, Debela Alema Teklemariyem, Phong Ba Dao

    Robust condition monitoring of wind turbine blades is essential for reducing downtime and maintenance costs, particularly under variable operating conditions. While recent studies suggest that combining trend monitoring (TM) with change point detection (CPD) can improve diagnostic performance, it remains unclear whether such integration is beneficial for all fault types. This study experimentally evaluates the integration of TM and CPD using vibration data from a laboratory-scale wind turbine for two representative blade faults: leading-edge erosion and twist misalignment. For the erosion case, discrete wavelet transform (DWT) energy features exhibit a clear and persistent increase in mid-frequency content, with energy deviations of approximately 34–45% relative to the healthy state. However, Bayesian Online Change Point Detection (BOCPD) does not reveal distinct change points, indicating that CPD provides limited additional value for gradual, steady-state degradation. In contrast, for twist misalignment, the short-time Fast Fourier Transform (FFT) features reveal dynamic spectral redistribution, and CPD applied to spectral centroid trends produces a sharp, localized detection signature. These results demonstrate that integrating TM with CPD significantly enhances fault detectability for dynamic, instability-driven faults, while TM alone is sufficient for smooth, steady-state degradation. This study provides an evidence-based guideline for selectively integrating CPD into wind turbine blade condition monitoring systems based on fault physics.


  • Open Access

    CFD-Driven Design Optimization of Corrugated-Flange Diffuser-Integrated Wind Turbines for Enhanced Performance

    by Debela Alema Teklemariyem, Nasir Hussain Razvi Syed, Phong Ba Dao

    In the global shift toward sustainable energy, enhancing the efficiency of renewable energy systems plays a pivotal role in advancing the Sustainable Development Goals. This study focuses on optimizing the design of a corrugated-flange diffuser integrated with a wind turbine to enhance its performance, particularly in low-wind conditions. While most previous research has examined wind farm performance at high wind speeds, the challenge of effective power extraction at low wind speeds remains largely unresolved. The potential of diffusers to enhance wind turbine efficiency under low-wind conditions has received limited investigation, with most prior studies focusing solely on empty diffuser configurations without turbine integration. In addition, the influence of flange geometry on diffuser performance remains largely unexplored. In this study, parametric analyses were conducted to identify the optimal diffuser design, followed by comparative performance evaluations of configurations with and without turbine integration, using computational fluid dynamics (CFD) simulations. The results show that integrating a turbine with the optimized corrugated-flange diffuser increased flow velocity by 67.85%, achieving an average of approximately 14 m/s around the blade region. In comparison, the optimized corrugated-flange diffuser alone increased flow velocity by 44%, from 4.5 m/s to 8.036 m/s. These findings highlight the potential of optimized diffuser designs to enhance small-scale wind turbine performance in low-wind conditions.