Haitian Zhou
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haitian Zhou has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Haidong Chen
Guangdong Provincial Key Laboratory of Millimeter-Wave and Terahertz, Guangdong-Hong Kong-Macao Joint Laboratory for Millimeter-Wave and Terahertz, School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China
3 shared publications - Wenquan Che
South China University of Technology
3 shared publications - Jieyao Yang
School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China
2 shared publications - Quan Xue
South China University of Technology
2 shared publications Haidong Chen
School of Electronic and Information Engineering South China University of Technology Guangzhou China
1 shared publication- He Huang
School of Electronic and Information Engineering, South China University of Technology, Guangzhou, China
1 shared publication
Latest Publications
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-6
Improvement of Permittivity Measurement for Materials With Arbitrary Thickness Based on Rectangular Waveguide
In this letter, an improvement of the NRW transmission/reflection method based on the rectangular waveguide is proposed, providing a solution for measuring the material’s complex permittivity with large electrical thicknesses in a waveguide-based system. The proposed method primarily focuses on addressing the issues of half-wavelength divergence and multiple roots by reformulating the calculation equations and compensating for the imaginary part of the propagation constant. A procedure is proposed, and a full-wave simulation is conducted to verify the method’s correctness. A measurement system is fabricated to measure the complex permittivities of three materials with different thicknesses in the frequency range of 8-12 GHz. Compared with existing arts, our proposed method has some advantages, such as avoiding the very low start frequency and initial value prediction, using existing calibration kits, and operating with high accuracy.
- 22 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-6
Improvement of Permittivity Measurement for Materials With Arbitrary Thickness Based on Rectangular Waveguide
In this letter, an improvement of the NRW transmission/reflection method based on the rectangular waveguide is proposed, providing a solution for measuring the material’s complex permittivity with large electrical thicknesses in a waveguide-based system. The proposed method primarily focuses on addressing the issues of half-wavelength divergence and multiple roots by reformulating the calculation equations and compensating for the imaginary part of the propagation constant. A procedure is proposed, and a full-wave simulation is conducted to verify the method’s correctness. A measurement system is fabricated to measure the complex permittivities of three materials with different thicknesses in the frequency range of 8-12 GHz. Compared with existing arts, our proposed method has some advantages, such as avoiding the very low start frequency and initial value prediction, using existing calibration kits, and operating with high accuracy.
- Open Access
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 19 (1)
Improved Permittivity Measurement for the Material With Arbitrary Thickness Based on NRW and Adaptivity of Propagation Constant
An improved Nicolson‐Ross‐Weir (NRW) transmission/reflection method with the algorithm of adapting propagation constant is proposed in this paper for the permittivity measurement of that material with arbitrary thickness. The basic principle of the NRW method is reviewed and verified first, and the proposed improved method and adaptive algorithm are introduced and simulated for verification using the coaxial line measurement system. Both 2.92 and 7.0 mm measurement systems are fabricated to verify our method by measuring four different materials. By comparing the measured results in existing art and those using the proposed method, as well as the uncertainty and error analyses, one can see that our proposed method has the capability of measuring the permittivity of those materials with arbitrary thickness with high accuracy and efficiency.
- 1 January 2025
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 19 (1)
Open AccessImproved Permittivity Measurement for the Material With Arbitrary Thickness Based on NRW and Adaptivity of Propagation Constant
An improved Nicolson‐Ross‐Weir (NRW) transmission/reflection method with the algorithm of adapting propagation constant is proposed in this paper for the permittivity measurement of that material with arbitrary thickness. The basic principle of the NRW method is reviewed and verified first, and the proposed improved method and adaptive algorithm are introduced and simulated for verification using the coaxial line measurement system. Both 2.92 and 7.0 mm measurement systems are fabricated to verify our method by measuring four different materials. By comparing the measured results in existing art and those using the proposed method, as well as the uncertainty and error analyses, one can see that our proposed method has the capability of measuring the permittivity of those materials with arbitrary thickness with high accuracy and efficiency.
- 8 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Advanced Multiprobe Dual-Polarized Arch System for Microwave Reflectance Measurement
This paper proposes a new dual-polarization multi-probe arch measurement system with a 2-18 GHz measurement frequency range. The basic principle of the arch measurement system is reviewed, and the hardware is introduced in detail. Based on the simulated results, the time gating method is presented, proving a useful way to reduce spurious coupling and clutter interference. The proposed arch measurement system is implemented and some materials such as commercial PTFE, FR-4, and customized paper-based honeycomb N15 are measured for verification. The results based on our proposed method have approximately +/-2 dB amplitude differences and 1 GHz frequency shift compared to those results based on the RCS method, and approximately 5 dB amplitude differences and 2 GHz shift compared to those results based on another customized arch system. The calculated uncertainty of the whole system is less than 4 dB and the measurement time of a single sample is within 2 minutes. The proposed measurement system has remarkable advantages such as high measurement accuracy, fast measurement speed, and wide application range.
- 8 November 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 73 (00189456) , 1-11
Advanced Multiprobe Dual-Polarized Arch System for Microwave Reflectance Measurement
This paper proposes a new dual-polarization multi-probe arch measurement system with a 2-18 GHz measurement frequency range. The basic principle of the arch measurement system is reviewed, and the hardware is introduced in detail. Based on the simulated results, the time gating method is presented, proving a useful way to reduce spurious coupling and clutter interference. The proposed arch measurement system is implemented and some materials such as commercial PTFE, FR-4, and customized paper-based honeycomb N15 are measured for verification. The results based on our proposed method have approximately +/-2 dB amplitude differences and 1 GHz frequency shift compared to those results based on the RCS method, and approximately 5 dB amplitude differences and 2 GHz shift compared to those results based on another customized arch system. The calculated uncertainty of the whole system is less than 4 dB and the measurement time of a single sample is within 2 minutes. The proposed measurement system has remarkable advantages such as high measurement accuracy, fast measurement speed, and wide application range.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Measurement of Anisotropic Material by Using Orthomode Transducer for High Efficiency
In this article, a novel method measuring anisotropic dielectric permittivity is proposed, based on the dual-mode system consisting of orthomode transducers (OMTs), square waveguide (SWG), rectangular waveguide (RWG), and so on. The proposed method is excited based on the traditional nicolson-ross-weir (NRW) method and can measure the anisotropic permittivity at one time without moving the material under test (MUT). The basic principle of the NRW method is reviewed and verified, the proposed calibration method is introduced, the key component OMT is designed, the measurement system is set up, and the results are calculated and verified in 9.8–12 GHz. The measured and compared results show that the proposed method is potentially to be an effective and accurate solution for the permittivity measurement of anisotropic material.
- 25 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 71 (00189456) , 1-9
Measurement of Anisotropic Material by Using Orthomode Transducer for High Efficiency
In this article, a novel method measuring anisotropic dielectric permittivity is proposed, based on the dual-mode system consisting of orthomode transducers (OMTs), square waveguide (SWG), rectangular waveguide (RWG), and so on. The proposed method is excited based on the traditional nicolson-ross-weir (NRW) method and can measure the anisotropic permittivity at one time without moving the material under test (MUT). The basic principle of the NRW method is reviewed and verified, the proposed calibration method is introduced, the key component OMT is designed, the measurement system is set up, and the results are calculated and verified in 9.8–12 GHz. The measured and compared results show that the proposed method is potentially to be an effective and accurate solution for the permittivity measurement of anisotropic material.