JYJieyao Yang

Jieyao Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jieyao Yang has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Improvement of Permittivity Measurement for Materials With Arbitrary Thickness Based on Rectangular Waveguide

    by Haitian Zhou, Haidong Chen, Jieyao Yang, He Huang, Xi Dai, Shuyou Gan, Mu Tan, Wenquan Che

    In this letter, an improvement of the NRW transmission/reflection method based on the rectangular waveguide is proposed, providing a solution for measuring the material’s complex permittivity with large electrical thicknesses in a waveguide-based system. The proposed method primarily focuses on addressing the issues of half-wavelength divergence and multiple roots by reformulating the calculation equations and compensating for the imaginary part of the propagation constant. A procedure is proposed, and a full-wave simulation is conducted to verify the method’s correctness. A measurement system is fabricated to measure the complex permittivities of three materials with different thicknesses in the frequency range of 8-12 GHz. Compared with existing arts, our proposed method has some advantages, such as avoiding the very low start frequency and initial value prediction, using existing calibration kits, and operating with high accuracy.


  • Advanced Multiprobe Dual-Polarized Arch System for Microwave Reflectance Measurement

    by Haidong Chen, Zhaoling He, Jieyao Yang, Weijun Zhong, Haitian Zhou, Mengzhu Yan, Yi Wang, Jun Zhang, Weijie Lin, Linbo Chen, et al.

    This paper proposes a new dual-polarization multi-probe arch measurement system with a 2-18 GHz measurement frequency range. The basic principle of the arch measurement system is reviewed, and the hardware is introduced in detail. Based on the simulated results, the time gating method is presented, proving a useful way to reduce spurious coupling and clutter interference. The proposed arch measurement system is implemented and some materials such as commercial PTFE, FR-4, and customized paper-based honeycomb N15 are measured for verification. The results based on our proposed method have approximately +/-2 dB amplitude differences and 1 GHz frequency shift compared to those results based on the RCS method, and approximately 5 dB amplitude differences and 2 GHz shift compared to those results based on another customized arch system. The calculated uncertainty of the whole system is less than 4 dB and the measurement time of a single sample is within 2 minutes. The proposed measurement system has remarkable advantages such as high measurement accuracy, fast measurement speed, and wide application range.