RKRussell R. Kibbe

Russell R. Kibbe

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Russell R. Kibbe has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • David Charles Muddiman

    Biological Imaging Laboratory for Disease and Exposure Research (BILDER), Department of Chemistry, North Carolina State University, Raleigh, USA

    11 shared publications
  • Alexandria L. Sohn

    Biological Imaging Laboratory for Disease and Exposure Research (BILDER), Department of Chemistry North Carolina State University Raleigh North Carolina USA

    2 shared publications
  • Alexandria L. Sohn

    FTMS Laboratory for Human Health Research, Department of Chemistry, North Carolina State University, Raleigh, USA

    2 shared publications
  • Emily C. Hector

    Department of Biostatistics University of Michigan Ann Arbor Michigan USA

    2 shared publications
  • Kenneth P. Garrard

    FTMS Laboratory for Human Health Research, Department of Chemistry North Carolina State University Raleigh North Carolina USA

    2 shared publications
  • Quinn Mills

    Biological Imaging Laboratory for Disease and Exposure Research (BILDER), Department of Chemistry North Carolina State University Raleigh North Carolina USA

    2 shared publications

Latest Publications

  • Open Access

    A Convolutional Neural Network and Transfer Learning Approach for Accelerated Quantitative Mass Spectrometry Imaging

    by Russell R. Kibbe, Emily C. Hector, David C. Muddiman

    This research presents a novel approach to accelerate quantitative mass spectrometry imaging (qMSI) measurements using convolutional neural networks (CNNs) with a transfer learning approach. Current methods are time consuming, require numerous specific steps that allow for the introduction of error, and involve meticulous data analysis. The concept is to build a machine learning model that can be used for future qMSI experiments thereby saving time and decreasing variability. In essence, this model is a CNN trained by transfer learning on a smaller dataset of ion images with a known concentration of analyte, which is then applied to future qMSI studies when quantifying the same molecule in the same tissue type. This enhances the speed with which this analysis can be completed and, in theory, decreases the variability seen with previous methods. In this work, we demonstrate that, by using previously collected MSI data and a transfer learning approach, our CNN model allows for the accurate concentration to be determined on new tissues.


  • Mechanistic Insights into Visible-Light-Induced ATRA Reactions Powered by the Symbiotic Relationship between Cu(II)/Cu(I) Phenanthroline Complexes

    by Sarah Arteta, Mawuli Deegbey, Nicolas Durand, Russell Kibbe, Johannes Floß, Alexandra T. Barth, David C. Muddiman, Elena Jakubikova, Oliver Reiser, Felix N. Castellano


  • Open Access

    Part A: Implementing an Analyte Panel and Sampling Protocol for Quality Control in Mass Spectrometry Imaging

    by Quinn Mills, Russell R. Kibbe, Alexandria L. Sohn, Andrew J. Percy, Krista Backiel, David C. Muddiman

    Rationale: While quality control (QC) and system suitability testing (SST) methods are commonly employed in mass spectrometry, the field of mass spectrometry imaging (MSI) currently lacks any universally accepted QC/SST protocols. These methods can prevent the loss of precious samples due to suboptimal instrument conditions and/or data quality, but they are more challenging to implement on MSI platforms. Herein, a panel of analytes is conveniently analyzed in a setup that reflects a typical MSI imaging experiment, and guidance is provided for downstream QC/SST evaluation. Methods: The analyte panel will be commercially available and consists of three pairs of unlabeled (NAT) analytes and their stable isotope–labeled (SIL) analogues; a deviation from the standard procedure is also included, which incorporates a polymer to expand m / z coverage. The NAT three‐plex (or four‐plex with the added polymer) is analyzed as a droplet on a slide, and the SIL three‐plex is doped into the electrospray solvent, isolating the NAT and SIL compounds to different source components. Datasets are collected on clean and compromised instruments to inform QC/SST software and later evaluate instrument conditions or isolated metrics of data quality. Results: A procedure was created for QC/SST analysis on MSI platforms, which can be optionally paired with the freely available software Supervised Learning for Instrument Classification and Evaluation for Mass Spectrometry Imaging (SLICE‐MSI) to classify the condition of the instrument. The SIL data may be monitored separately during imaging experiments for continuous evaluation of electrospray stability. The protocol highlights areas that may be adapted for other ionization sources for widespread use. Conclusions: The protocol described herein uses a panel of NAT and SIL compounds to offer an objective and accurate determination of QC/SST on MSI platforms.


  • Open Access

    Part B: SLICE‐MSI—A Machine Learning Interface for System Suitability Testing of Mass Spectrometry Imaging Platforms

    by Russell R. Kibbe, Quinn Mills, Alexandria L. Sohn, David C. Muddiman

    Rationale: The field of mass spectrometry imaging is currently devoid of standardized protocols or commercially available products designed for system suitability testing of MSI platforms. Machine learning is an approach that can quickly and effectively identify complex patterns in data and use them to make informed classifications, but there is a technical barrier to implementing these algorithms. Here we package the machine learning algorithms into a user‐friendly interface to make community‐wide implementation of this protocol possible. Methods: The software package is built entirely in the Python language using the PySimpleGUI library for the construction of the interface, Pandas and Numpy libraries for data formatting and manipulation, and the Scikit‐Learn library for the implementation of machine learning algorithms. Training data is collected on an instrument under clean and compromised conditions that can then be used to evaluate model performance and to train models prior to interrogating unknown samples before, during, or after experiments. Results: Detailed instructions are provided for the effective use of the SLICE‐MSI software package to use machine learning to evaluate instrument condition of MSI platforms. File formatting and generalizable steps are clearly described to make the implementation of this package easy for multiple labs and different MSI platform configurations. Conclusions: In this protocol, we demonstrate SLICE‐MSI, a machine learning graphical user interface for efficient and easy implementation of QC instrument classification of mass spectrometry imaging platforms.


  • Open Access

    Absolute Quantification of Glutathione Using Top‐Hat Optics for IR‐MALDESI Mass Spectrometry Imaging

    by Emily R. Bruce, Russell R. Kibbe, Emily C. Hector, David C. Muddiman

    Infrared matrix‐assisted laser desorption electrospray ionization (IR‐MALDESI) uses an infrared laser to desorb neutral biomolecules with postionization via ESI at atmospheric pressure. The Gaussian profile of the laser with conventional optics results in the heating of adjacent nonablated tissue due to the energy profile being circular. A diffractive optical element (DOE) was incorporated into the optical train to correct for this disadvantage. The DOE produces a top‐hat beam profile and square ablation spots, which have uniform energy distributions. Although beneficial to mass spectrometry imaging (MSI), it is unknown how the DOE affects the ability to perform quantitative MSI (qMSI). In this work, we evaluate the performance of the DOE optical train against our conventional optics to define the potential advantages of the top‐hat beam profile. Absolute quantification of glutathione (GSH) was achieved by normalizing the analyte of interest to homoglutathione (hGSH), spotting a dilution series of stable isotope labeled glutathione (SIL‐GSH), and analyzing by IR‐MALDESI MSI with either the conventional optical train or with the DOE incorporated. Statistical comparison indicates that there was no significant difference between the quantification of GSH by the two optical trains as evidenced by similar calibration curves. Results support that both optical trains can be used for qMSI without a change in the ability to carry out absolute quantification but providing the benefits of the top‐hat optical train (i.e., flat energy profile and square ablation spots)—for future qMSI studies.


  • Leveraging Supervised Machine Learning Algorithms for System Suitability Testing of Mass Spectrometry Imaging Platforms

    by Russell R. Kibbe, Alexandria L. Sohn, David C. Muddiman

    Quality control and system suitability testing are vital protocols implemented to ensure the repeatability and reproducibility of data in mass spectrometry investigations. However, mass spectrometry imaging (MSI) analyses present added complexity since both chemical and spatial information are measured. Herein, we employ various machine learning algorithms and a novel quality control mixture to classify the working conditions of an MSI platform. Each algorithm was evaluated in terms of its performance on unseen data, validated with negative control data sets to rule out confounding variables or chance agreement, and utilized to determine the necessary sample size to achieve a high level of accurate classifications. In this work, a robust machine learning workflow was established where models could accurately classify the instrument condition as clean or compromised based on data metrics extracted from the analyzed quality control sample. This work highlights the power of machine learning to recognize complex patterns in MSI data and use those relationships to perform a system suitability test for MSI platforms.


  • Open Access

    Quantitative mass spectrometry imaging (qMSI): A tutorial

    by Russell R. Kibbe, David C. Muddiman

    Mass spectrometry imaging (MSI) is an analytical technique that enables the simultaneous detection of hundreds to thousands of chemical species while retaining their spatial information; usually, MSI is applied to biological tissues. Combining these elements can create ion images, which allows for the identification and localization of multiple chemical species within the sample. Being able to produce molecular images of biological tissues has already impacted the study of health and disease; however, the next logical step is being able to combine MSI with quantitative mass spectrometry methods to both quantify and determine the localization of disease progression or drug action. In this tutorial, we will detail the main factors to consider when designing a qMSI experiment and highlight the methods that have been developed to overcome these added complexities, specifically for those newer to the field of MSI.


  • Open Access

    A statistical approach to system suitability testing for mass spectrometry imaging

    by Alexandria L. Sohn, Russell R. Kibbe, Olivia E. Dioli, Emily C. Hector, Hongxia Bai, Kenneth P. Garrard, David C. Muddiman

    Rationale: Mass spectrometry imaging (MSI) elevates the power of conventional mass spectrometry (MS) to multidimensional space, elucidating both chemical composition and localization. However, the field lacks any robust quality control (QC) and/or system suitability testing (SST) protocols to monitor inconsistencies during data acquisition, both of which are integral to ensure the validity of experimental results. To satisfy this demand in the community, we propose an adaptable QC/SST approach with five analyte options amendable to various ionization MSI platforms (e.g., desorption electrospray ionization, matrix‐assisted laser desorption/ionization [MALDI], MALDI‐2, and infrared matrix‐assisted laser desorption electrospray ionization [IR‐MALDESI]). Methods: A novel QC mix was sprayed across glass slides to collect QC/SST regions‐of‐interest (ROIs). Data were collected under optimal conditions and on a compromised instrument to construct and refine the principal component analysis (PCA) model in R. Metrics, including mass measurement accuracy and spectral accuracy, were evaluated, yielding an individual suitability score for each compound. The average of these scores is utilized to inform if troubleshooting is necessary. Results: The PCA‐based SST model was applied to data collected when the instrument was compromised. The resultant SST scores were used to determine a statistically significant threshold, which was defined as 0.93 for IR‐MALDESI‐MSI analyses. This minimizes the type‐I error rate, where the QC/SST would report the platform to be in working condition when cleaning is actually necessary. Further, data scored after a partial cleaning demonstrate the importance of QC and frequent full instrument cleaning. Conclusions: This study is the starting point for addressing an important issue and will undergo future development to improve the efficiency of the protocol. Ultimately, this work is the first of its kind and proposes this approach as a proof of concept to develop and implement universal QC/SST protocols for a variety of MSI platforms.


  • Achieving Sub-Parts-per-Million Mass Measurement Accuracy on an Orbitrap Mass Spectrometry Imaging Platform without Automatic Gain Control

    by Russell R. Kibbe, David C. Muddiman

    The collection of profile data is standard practice within the field of mass spectrometry (MS). However, profile data collection often results in large data files that require extensive processing times, especially in mass spectrometry imaging (MSI) studies where thousands of high-resolution scans are recorded. Natively collecting centroid MS data is an alternative that effectively reduces both the resulting file size and the data processing time. Herein, high-resolution accurate mass (HRAM) Orbitrap MSI data on mouse liver tissue sections without automatic gain control (AGC) were natively collected in both profile and centroid modes and compared based on the file size and processing time. Additionally, centroid data were evaluated against the profile data with regard to the spectra integrity, mass measurement accuracy (MMA), and the number of lipid annotations to ensure that centroid data did not compromise the data quality. For both native and postacquisition centroided data, the variation in mass measurement accuracy decreased relative to the profile data collection. Furthermore, centroid data collection increased the number of METASPACE database annotations indicating higher sensitivity and greater accuracy for lipid annotation compared to native profile data collection. Profile MSI data was shown to have a higher likelihood of false positive identifications due to an increased number of data points on either side of the peaks, whereas the same trend was not observed in data collected in native centroid data collection. This publication explores and explains the importance in properly centroiding MSI data, either natively or by adequate centroiding methods, to obtain the most accurate information and come to the best conclusions. These data support that natively collecting centroid data significantly improves MMA to sub-ppm levels without AGC and reduces false positive annotations.


  • Open Access

    On the importance of color in mass spectrometry imaging

    by Kevan T. Knizner, Russell R. Kibbe, Kenneth P. Garrard, Jamie R. Nuñez, Christopher R. Anderton, David C. Muddiman

    Mass spectrometry imaging (MSI) data visualization relies on heatmaps to show the spatial distribution and measured abundances of molecules within a sample. Nonuniform color gradients such as jet are still commonly used to visualize MSI data, increasing the probability of data misinterpretation and false conclusions. Also, the use of nonuniform color gradients and the combination of hues used in common colormaps make it challenging for people with color vision deficiencies (CVDs) to visualize and accurately interpret data. Here we present best practices for choosing a colormap to accurately display MSI data, improve readability, and accommodate all CVDs. We also provide other resources on the misuse of color in the scientific field and resources on scientifically derived colormaps presented herein.