Alexandria L. Sohn
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Alexandria L. Sohn has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- David Charles Muddiman
Biological Imaging Laboratory for Disease and Exposure Research (BILDER), Department of Chemistry, North Carolina State University, Raleigh, USA
7 shared publications - Alena N. Joignant
FTMS Laboratory for Human Health Research, Department of Chemistry North Carolina State University Raleigh North Carolina USA
2 shared publications Kenneth P. Garrard
FTMS Laboratory for Human Health Research, Department of Chemistry North Carolina State University Raleigh North Carolina USA
2 shared publications- Russell R. Kibbe
Biological Imaging Laboratory for Disease and Exposure Research (BILDER), Department of Chemistry North Carolina State University Raleigh North Carolina USA
2 shared publications - Boone M. Prentice
Department of Chemistry, University of Florida, Gainesville, USA
1 shared publication Emily C. Hector
Department of Statistics North Carolina State University Raleigh North Carolina USA
1 shared publication
Latest Publications
- 13 November 2025
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 24 (12) , 5995-6005
Use of Synthetic Standard Peptides in Standardized Digests to Evaluate Both Sample and Instrument Suitability in Proteomics
Whole proteome digests are routinely used to diagnose chromatograph and mass spectrometer outputs to ensure suitability for the analysis of complex matrices, but their usage inherently fails to prove system reliability under varying "load" conditions. There is a need for a reliable, predictive tool that can explain variation in both instrument response and downstream identification results from a whole proteome analysis. We designed an experiment using a hybrid sample of standardized materials to create such an approach, which could then lead to a new system suitability test for bottom-up proteomics. The standard HeLa protein digest was combined with Promega 6 × 5 LC-MS/MS Peptide Reference Mix and diluted to create a range of sample mass loadings and reference peptide concentrations. Data were collected using data-dependent (DDA) and data-independent acquisition methods, and reference peptide peak abundances were correlated to the number of protein identifications (IDs), peptide groups (PGs), and peptide spectrum matches (PSMs) found by Proteome Discoverer. An asymptotic relationship explained decreasing IDs, PGs, and PSMs identified from the HeLa digest with decreasing 6 × 5 Peptide abundances. By linking the mass spectrometer measurement of ion abundance with downstream results obtained from a complex matrix, we successfully used the hybrid standardized sample to mathematically define new system suitability thresholds.
- 13 November 2025
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 24 (12) , 5995-6005
Use of Synthetic Standard Peptides in Standardized Digests to Evaluate Both Sample and Instrument Suitability in Proteomics
Whole proteome digests are routinely used to diagnose chromatograph and mass spectrometer outputs to ensure suitability for the analysis of complex matrices, but their usage inherently fails to prove system reliability under varying "load" conditions. There is a need for a reliable, predictive tool that can explain variation in both instrument response and downstream identification results from a whole proteome analysis. We designed an experiment using a hybrid sample of standardized materials to create such an approach, which could then lead to a new system suitability test for bottom-up proteomics. The standard HeLa protein digest was combined with Promega 6 × 5 LC-MS/MS Peptide Reference Mix and diluted to create a range of sample mass loadings and reference peptide concentrations. Data were collected using data-dependent (DDA) and data-independent acquisition methods, and reference peptide peak abundances were correlated to the number of protein identifications (IDs), peptide groups (PGs), and peptide spectrum matches (PSMs) found by Proteome Discoverer. An asymptotic relationship explained decreasing IDs, PGs, and PSMs identified from the HeLa digest with decreasing 6 × 5 Peptide abundances. By linking the mass spectrometer measurement of ion abundance with downstream results obtained from a complex matrix, we successfully used the hybrid standardized sample to mathematically define new system suitability thresholds.
- Open Access
- 3 February 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (8) , 1649-1661
Three-dimensional mass spectrometry imaging (3D MSI): incorporating top-hat IR-MALDESI and automatic z-axis correction
Leveraging a depth profiling approach expands the chemical elucidation of mass spectrometry imaging techniques to another dimension. Three-dimensional MSI (3D MSI) reveals the distribution of analytes with greater anatomical detail to add another level of information in a biological study. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) has demonstrated utility for an ablation-based approach, enabling simplified sample preparation workflows and streamlined data processing pipelines compared to a serial-sectioning strategy. To improve 3D MSI on the IR-MALDESI platform, two technologies have been characterized in tandem for the intention of minimizing sampling bias: (1) a top-hat optical train and (2) a chromatic confocal probe (CA probe). While the modified optical train creates a square spot size to avoid a Gaussian ablation crater after the analysis of subsequent layers, the CA probe enables automatic z-axis correction (AzC) to maintain the laser’s focus on the surface of the sample. The work herein demonstrates the integration and optimization of these technologies on mouse skin, motivated by the clear biological skin layers that result in differential lipid expression and subsequent detection. Results support that a laser energy of 1.3 mJ/burst with the top-hat optical train and a 120 µm step size in the X and Y dimensions presented a comparable depth resolution to previous studies at under 7 µm. Further, the optimized parameters were utilized on two biological replicates to evaluate method reproducibility where lipid annotations and their abundance were considered.
- 3 February 2025
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 417 (8) , 1649-1661
Open AccessThree-dimensional mass spectrometry imaging (3D MSI): incorporating top-hat IR-MALDESI and automatic z-axis correction
Leveraging a depth profiling approach expands the chemical elucidation of mass spectrometry imaging techniques to another dimension. Three-dimensional MSI (3D MSI) reveals the distribution of analytes with greater anatomical detail to add another level of information in a biological study. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) has demonstrated utility for an ablation-based approach, enabling simplified sample preparation workflows and streamlined data processing pipelines compared to a serial-sectioning strategy. To improve 3D MSI on the IR-MALDESI platform, two technologies have been characterized in tandem for the intention of minimizing sampling bias: (1) a top-hat optical train and (2) a chromatic confocal probe (CA probe). While the modified optical train creates a square spot size to avoid a Gaussian ablation crater after the analysis of subsequent layers, the CA probe enables automatic z-axis correction (AzC) to maintain the laser’s focus on the surface of the sample. The work herein demonstrates the integration and optimization of these technologies on mouse skin, motivated by the clear biological skin layers that result in differential lipid expression and subsequent detection. Results support that a laser energy of 1.3 mJ/burst with the top-hat optical train and a 120 µm step size in the X and Y dimensions presented a comparable depth resolution to previous studies at under 7 µm. Further, the optimized parameters were utilized on two biological replicates to evaluate method reproducibility where lipid annotations and their abundance were considered.
- 3 September 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (10) , 4384-4391
Leveraging Supervised Machine Learning Algorithms for System Suitability Testing of Mass Spectrometry Imaging Platforms
Quality control and system suitability testing are vital protocols implemented to ensure the repeatability and reproducibility of data in mass spectrometry investigations. However, mass spectrometry imaging (MSI) analyses present added complexity since both chemical and spatial information are measured. Herein, we employ various machine learning algorithms and a novel quality control mixture to classify the working conditions of an MSI platform. Each algorithm was evaluated in terms of its performance on unseen data, validated with negative control data sets to rule out confounding variables or chance agreement, and utilized to determine the necessary sample size to achieve a high level of accurate classifications. In this work, a robust machine learning workflow was established where models could accurately classify the instrument condition as clean or compromised based on data metrics extracted from the analyzed quality control sample. This work highlights the power of machine learning to recognize complex patterns in MSI data and use those relationships to perform a system suitability test for MSI platforms.
- 3 September 2024
- Published by American Chemical Society (ACS) in Journal of Proteome Research
- Vol. 23 (10) , 4384-4391
Leveraging Supervised Machine Learning Algorithms for System Suitability Testing of Mass Spectrometry Imaging Platforms
Quality control and system suitability testing are vital protocols implemented to ensure the repeatability and reproducibility of data in mass spectrometry investigations. However, mass spectrometry imaging (MSI) analyses present added complexity since both chemical and spatial information are measured. Herein, we employ various machine learning algorithms and a novel quality control mixture to classify the working conditions of an MSI platform. Each algorithm was evaluated in terms of its performance on unseen data, validated with negative control data sets to rule out confounding variables or chance agreement, and utilized to determine the necessary sample size to achieve a high level of accurate classifications. In this work, a robust machine learning workflow was established where models could accurately classify the instrument condition as clean or compromised based on data metrics extracted from the analyzed quality control sample. This work highlights the power of machine learning to recognize complex patterns in MSI data and use those relationships to perform a system suitability test for MSI platforms.
- Open Access
- 8 March 2024
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 38 (9) , e9725
A statistical approach to system suitability testing for mass spectrometry imaging
Rationale: Mass spectrometry imaging (MSI) elevates the power of conventional mass spectrometry (MS) to multidimensional space, elucidating both chemical composition and localization. However, the field lacks any robust quality control (QC) and/or system suitability testing (SST) protocols to monitor inconsistencies during data acquisition, both of which are integral to ensure the validity of experimental results. To satisfy this demand in the community, we propose an adaptable QC/SST approach with five analyte options amendable to various ionization MSI platforms (e.g., desorption electrospray ionization, matrix‐assisted laser desorption/ionization [MALDI], MALDI‐2, and infrared matrix‐assisted laser desorption electrospray ionization [IR‐MALDESI]). Methods: A novel QC mix was sprayed across glass slides to collect QC/SST regions‐of‐interest (ROIs). Data were collected under optimal conditions and on a compromised instrument to construct and refine the principal component analysis (PCA) model in R. Metrics, including mass measurement accuracy and spectral accuracy, were evaluated, yielding an individual suitability score for each compound. The average of these scores is utilized to inform if troubleshooting is necessary. Results: The PCA‐based SST model was applied to data collected when the instrument was compromised. The resultant SST scores were used to determine a statistically significant threshold, which was defined as 0.93 for IR‐MALDESI‐MSI analyses. This minimizes the type‐I error rate, where the QC/SST would report the platform to be in working condition when cleaning is actually necessary. Further, data scored after a partial cleaning demonstrate the importance of QC and frequent full instrument cleaning. Conclusions: This study is the starting point for addressing an important issue and will undergo future development to improve the efficiency of the protocol. Ultimately, this work is the first of its kind and proposes this approach as a proof of concept to develop and implement universal QC/SST protocols for a variety of MSI platforms.
- 8 March 2024
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 38 (9) , e9725
Open AccessA statistical approach to system suitability testing for mass spectrometry imaging
Rationale: Mass spectrometry imaging (MSI) elevates the power of conventional mass spectrometry (MS) to multidimensional space, elucidating both chemical composition and localization. However, the field lacks any robust quality control (QC) and/or system suitability testing (SST) protocols to monitor inconsistencies during data acquisition, both of which are integral to ensure the validity of experimental results. To satisfy this demand in the community, we propose an adaptable QC/SST approach with five analyte options amendable to various ionization MSI platforms (e.g., desorption electrospray ionization, matrix‐assisted laser desorption/ionization [MALDI], MALDI‐2, and infrared matrix‐assisted laser desorption electrospray ionization [IR‐MALDESI]). Methods: A novel QC mix was sprayed across glass slides to collect QC/SST regions‐of‐interest (ROIs). Data were collected under optimal conditions and on a compromised instrument to construct and refine the principal component analysis (PCA) model in R. Metrics, including mass measurement accuracy and spectral accuracy, were evaluated, yielding an individual suitability score for each compound. The average of these scores is utilized to inform if troubleshooting is necessary. Results: The PCA‐based SST model was applied to data collected when the instrument was compromised. The resultant SST scores were used to determine a statistically significant threshold, which was defined as 0.93 for IR‐MALDESI‐MSI analyses. This minimizes the type‐I error rate, where the QC/SST would report the platform to be in working condition when cleaning is actually necessary. Further, data scored after a partial cleaning demonstrate the importance of QC and frequent full instrument cleaning. Conclusions: This study is the starting point for addressing an important issue and will undergo future development to improve the efficiency of the protocol. Ultimately, this work is the first of its kind and proposes this approach as a proof of concept to develop and implement universal QC/SST protocols for a variety of MSI platforms.
- Open Access
- 14 March 2023
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 58 (3) , e4911
Time of acquisition and high spatial resolution mass spectrometry imaging
The field of mass spectrometry imaging (MSI) is constantly evolving to analyze a diverse array of biological systems. A common goal is the need to resolve cellular and subcellular heterogeneity with high spatial resolution. As the field continues to progress towards high spatial resolution, other parameters must be considered when developing a practical method. Here, we discuss the impacts of high spatial resolution on the time of acquisition and the associated implications they have on an MSI analysis (e.g., area of the region of interest). This work presents a brief tutorial serving to evaluate high spatial resolution MSI relative to time of acquisition and data file size.
- 14 March 2023
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 58 (3) , e4911
Open AccessTime of acquisition and high spatial resolution mass spectrometry imaging
The field of mass spectrometry imaging (MSI) is constantly evolving to analyze a diverse array of biological systems. A common goal is the need to resolve cellular and subcellular heterogeneity with high spatial resolution. As the field continues to progress towards high spatial resolution, other parameters must be considered when developing a practical method. Here, we discuss the impacts of high spatial resolution on the time of acquisition and the associated implications they have on an MSI analysis (e.g., area of the region of interest). This work presents a brief tutorial serving to evaluate high spatial resolution MSI relative to time of acquisition and data file size.
- Open Access
- 5 February 2023
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 58 (2)
SMART: A data reporting standard for mass spectrometry imaging
Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra‐ and inter‐laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data.
- 5 February 2023
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 58 (2)
Open AccessSMART: A data reporting standard for mass spectrometry imaging
Mass spectrometry imaging (MSI) is an important analytical technique that simultaneously reports the spatial location and abundance of detected ions in biological, chemical, clinical, and pharmaceutical studies. As MSI grows in popularity, it has become evident that data reporting varies among different research groups and between techniques. The lack of consistency in data reporting inherently creates additional challenges in comparing intra‐ and inter‐laboratory MSI data. In this tutorial, we propose a unified data reporting system, SMART, based on the common features shared between techniques. While there are limitations to any reporting system, SMART was decided upon after significant discussion to more easily understand and benchmark MSI data. SMART is not intended to be comprehensive but rather capture essential baseline information for a given MSI study; this could be within a study (e.g., effect of spot size on the measured ion signals) or between two studies (e.g., different MSI platform technologies applied to the same tissue type). This tutorial does not attempt to address the confidence with which annotations are made nor does it deny the importance of other parameters that are not included in the current SMART format. Ultimately, the goal of this tutorial is to discuss the necessity of establishing a uniform reporting system to communicate MSI data in publications and presentations in a simple format to readily interpret the parameters and baseline outcomes of the data.
- Open Access
- 10 November 2022
- Published by MDPI AG in Metabolites
- Vol. 12 (11) , 1096
Interrogating the Metabolomic Profile of Amyotrophic Lateral Sclerosis in the Post-Mortem Human Brain by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI) Mass Spectrometry Imaging (MSI)
Amyotrophic lateral sclerosis (ALS) is an idiopathic, fatal neurodegenerative disease characterized by progressive loss of motor function with an average survival time of 2–5 years after diagnosis. Due to the lack of signature biomarkers and heterogenous disease phenotypes, a definitive diagnosis of ALS can be challenging. Comprehensive investigation of this disease is imperative to discovering unique features to expedite the diagnostic process and improve diagnostic accuracy. Here, we present untargeted metabolomics by mass spectrometry imaging (MSI) for comparing sporadic ALS (sALS) and C9orf72 positive (C9Pos) post-mortem frontal cortex human brain tissues against a control cohort. The spatial distribution and relative abundance of metabolites were measured by infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI for association to biological pathways. Proteomic studies on the same patients were completed via LC-MS/MS in a previous study, and results were integrated with imaging metabolomics results to enhance the breadth of molecular coverage. Utilizing METASPACE annotation platform and MSiPeakfinder, nearly 300 metabolites were identified across the sixteen samples, where 25 were identified as dysregulated between disease cohorts. The dysregulated metabolites were further examined for their relevance to alanine, aspartate, and glutamate metabolism, glutathione metabolism, and arginine and proline metabolism. The dysregulated pathways discussed are consistent with reports from other ALS studies. To our knowledge, this work is the first of its kind, reporting on the investigation of ALS post-mortem human brain tissue analyzed by multiomic MSI.
- 10 November 2022
- Published by MDPI AG in Metabolites
- Vol. 12 (11) , 1096
Open AccessInterrogating the Metabolomic Profile of Amyotrophic Lateral Sclerosis in the Post-Mortem Human Brain by Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI) Mass Spectrometry Imaging (MSI)
Amyotrophic lateral sclerosis (ALS) is an idiopathic, fatal neurodegenerative disease characterized by progressive loss of motor function with an average survival time of 2–5 years after diagnosis. Due to the lack of signature biomarkers and heterogenous disease phenotypes, a definitive diagnosis of ALS can be challenging. Comprehensive investigation of this disease is imperative to discovering unique features to expedite the diagnostic process and improve diagnostic accuracy. Here, we present untargeted metabolomics by mass spectrometry imaging (MSI) for comparing sporadic ALS (sALS) and C9orf72 positive (C9Pos) post-mortem frontal cortex human brain tissues against a control cohort. The spatial distribution and relative abundance of metabolites were measured by infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) MSI for association to biological pathways. Proteomic studies on the same patients were completed via LC-MS/MS in a previous study, and results were integrated with imaging metabolomics results to enhance the breadth of molecular coverage. Utilizing METASPACE annotation platform and MSiPeakfinder, nearly 300 metabolites were identified across the sixteen samples, where 25 were identified as dysregulated between disease cohorts. The dysregulated metabolites were further examined for their relevance to alanine, aspartate, and glutamate metabolism, glutathione metabolism, and arginine and proline metabolism. The dysregulated pathways discussed are consistent with reports from other ALS studies. To our knowledge, this work is the first of its kind, reporting on the investigation of ALS post-mortem human brain tissue analyzed by multiomic MSI.