Mu Yuan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mu Yuan has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Chen Li
China Jiliang University, Hangzhou, 310018, China.
3 shared publications - Bo Ye
College of Quality and Safety Engineering, China Jiliang University, Hangzhou 310018, China
1 shared publication Cheng Zhenbo
College of Computer Science and Technology, Zhejiang University of Technology, Hangzhou, China
1 shared publication- Gang Xiao
College of Computer Science and Technology, Zhejiang University of Technology, Hangzhou, China
1 shared publication - Jiangqin Ge
China Jiliang University, Hangzhou, China
1 shared publication - Jie Tian
Science and Technology Research Center of China Customs, Beijing 100026, China
1 shared publication
Latest Publications
- 15 August 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (7) , 1-22
Review of Fault Modes,Diagnosis and Prediction Methods for Elevator Systems
- 15 August 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (7) , 1-22
Review of Fault Modes,Diagnosis and Prediction Methods for Elevator Systems
- Open Access
- 2 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 2980
Design of Safety Evaluation and Risk Traceability System for Agricultural Product Quality
The quality and safety of agricultural products involve a variety of risk factors, a large amount of risk information data, and multiple circulation and disposal processes, making it difficult to accurately trace the source of risks. To achieve precise traceability of agricultural product quality and safety, the monitoring and supervision level of agricultural product traceability systems needs to be improved. In this paper, the agricultural product quality- and safety-related detection data are taken as the research object, the agricultural product supply chain and business process are sorted out, the agricultural product risk factors under the influence of heavy metals are analyzed, and the agricultural product quality and safety risk evaluation model is established. The agricultural product risk traceability system was designed based on the six-layer architecture of the equipment layer, data layer, service layer, application layer, display layer, and user layer. Combined with the agricultural product quality and safety risk evaluation model, the system data were stored and modified by using the MySQL relational database, and the agricultural product risk traceability system was developed, which realized the accurate traceability of the risk link of the quality and safety of agricultural products. The research results of this paper provide an effective information means for the quality and safety supervision of agricultural products, and provide a technical reference for the development of a traceability system of risk factors related to agricultural products, which has good practical significance.
- 2 April 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (7) , 2980
Open AccessDesign of Safety Evaluation and Risk Traceability System for Agricultural Product Quality
The quality and safety of agricultural products involve a variety of risk factors, a large amount of risk information data, and multiple circulation and disposal processes, making it difficult to accurately trace the source of risks. To achieve precise traceability of agricultural product quality and safety, the monitoring and supervision level of agricultural product traceability systems needs to be improved. In this paper, the agricultural product quality- and safety-related detection data are taken as the research object, the agricultural product supply chain and business process are sorted out, the agricultural product risk factors under the influence of heavy metals are analyzed, and the agricultural product quality and safety risk evaluation model is established. The agricultural product risk traceability system was designed based on the six-layer architecture of the equipment layer, data layer, service layer, application layer, display layer, and user layer. Combined with the agricultural product quality and safety risk evaluation model, the system data were stored and modified by using the MySQL relational database, and the agricultural product risk traceability system was developed, which realized the accurate traceability of the risk link of the quality and safety of agricultural products. The research results of this paper provide an effective information means for the quality and safety supervision of agricultural products, and provide a technical reference for the development of a traceability system of risk factors related to agricultural products, which has good practical significance.
- Open Access
- 18 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1764
Detection of Tomato Ringspot Virus Based on Microfluidic Impedance Sensor
A microfluidic impedance sensor embedded with gold interdigitated array microelectrodes was utilized to rapidly detect Tomato Ringspot Virus (ToRSV) and achieve efficient and precise detection. The electrochemical impedance spectrum was obtained by immobilizing ToRSV antibody on the surface of a gold interdigital array microelectrode and mixing it with ToRSV to generate an impedance change. The electrochemical impedance spectrum was obtained. The equivalent circuit was established to analyze the mechanism of impedance change, and the quantitative linear relationship between ToRSV concentration and impedance was established. According to an equivalent circuit analysis, ToRSV increases the solution resistance Rs, the electron transfer resistance Ret on the electrode surface, and the double layer capacitance Cdl, resulting in an increase in impedance. The results reveal that the ToRSV concentration detected in the range of 0.001 to 10 μg/mL ranges from 248.8 to 687.2 kΩ at the ideal detection frequency of 10.7 Hz, with a good linear connection, R2 = 0.98. When this method’s detection limit is tested, the impedance value is 367.68 kΩ. 0.0032 μg/mL was the detection limit. The sensor is quick and easy to use, has high detection sensitivity, and can be used to detect other plant viruses.
- 18 October 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (10) , 1764
Open AccessDetection of Tomato Ringspot Virus Based on Microfluidic Impedance Sensor
A microfluidic impedance sensor embedded with gold interdigitated array microelectrodes was utilized to rapidly detect Tomato Ringspot Virus (ToRSV) and achieve efficient and precise detection. The electrochemical impedance spectrum was obtained by immobilizing ToRSV antibody on the surface of a gold interdigital array microelectrode and mixing it with ToRSV to generate an impedance change. The electrochemical impedance spectrum was obtained. The equivalent circuit was established to analyze the mechanism of impedance change, and the quantitative linear relationship between ToRSV concentration and impedance was established. According to an equivalent circuit analysis, ToRSV increases the solution resistance Rs, the electron transfer resistance Ret on the electrode surface, and the double layer capacitance Cdl, resulting in an increase in impedance. The results reveal that the ToRSV concentration detected in the range of 0.001 to 10 μg/mL ranges from 248.8 to 687.2 kΩ at the ideal detection frequency of 10.7 Hz, with a good linear connection, R2 = 0.98. When this method’s detection limit is tested, the impedance value is 367.68 kΩ. 0.0032 μg/mL was the detection limit. The sensor is quick and easy to use, has high detection sensitivity, and can be used to detect other plant viruses.
- Open Access
- 28 July 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (8) , 1196
Study on the Motion Characteristics of Solid Particles in Fine Flow Channels by Ultrasonic Cavitation
Microjets caused by the cavitation effect in microchannels can affect the motion trajectory of solid particles in microchannels under ultrasonic conditions. The optimal parameters for an observation experiment were obtained through simulations, and an experiment was designed to verify these parameters. When the cavitation bubbles collapse in the near-wall area, the solid particles in the microchannel can be displaced along the expected motion trajectory. Using fluent software to simulate the bubble collapse process, it can be seen that, when an ultrasonic sound pressure acts on a bubble near the wall, the pressure causes the top of the bubble wall to sink inward and eventually penetrate the bottom of the bubble wall, forming a high-speed microjet. The maximum speed of the jet can reach nearly 28 m/s, and the liquid near the top of the bubble also moves at a high speed, driving the particles in the liquid towards the wall. A high-speed camera was used to observe the ultrasonic cavitation process of bubbles in the water to verify the simulation results. A comparison of particle motion with and without ultrasonic waves proved the feasibility of using the ultrasonic cavitation effect to guide small particles towards the wall. This method provides a novel experimental basis for changing the fluid layer state in the microchannel and improving precision machining.
- 28 July 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (8) , 1196
Open AccessStudy on the Motion Characteristics of Solid Particles in Fine Flow Channels by Ultrasonic Cavitation
Microjets caused by the cavitation effect in microchannels can affect the motion trajectory of solid particles in microchannels under ultrasonic conditions. The optimal parameters for an observation experiment were obtained through simulations, and an experiment was designed to verify these parameters. When the cavitation bubbles collapse in the near-wall area, the solid particles in the microchannel can be displaced along the expected motion trajectory. Using fluent software to simulate the bubble collapse process, it can be seen that, when an ultrasonic sound pressure acts on a bubble near the wall, the pressure causes the top of the bubble wall to sink inward and eventually penetrate the bottom of the bubble wall, forming a high-speed microjet. The maximum speed of the jet can reach nearly 28 m/s, and the liquid near the top of the bubble also moves at a high speed, driving the particles in the liquid towards the wall. A high-speed camera was used to observe the ultrasonic cavitation process of bubbles in the water to verify the simulation results. A comparison of particle motion with and without ultrasonic waves proved the feasibility of using the ultrasonic cavitation effect to guide small particles towards the wall. This method provides a novel experimental basis for changing the fluid layer state in the microchannel and improving precision machining.