Martin Bechmann
Research Subjects
Martin Bechmann has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Nikolaus Luft
Department of Ophthalmology, University Hospital, LMU Munich, Mathildenstrasse 8, 80336 Munich, Germany
2 shared publications - Rainer Wiltfang
SMILE Eyes Clinic, Munich, Germany
2 shared publications - Siegfried Georg Priglinger
Department of Ophthalmology, University Hospital, LMU Munich, Mathildenstrasse 8, 80336 Munich, Germany
2 shared publications Dirisamer Martin
University Eye Hospital, Ludwig-Maximilians-University, Munich, Germany
1 shared publication- Kreutzer Thomas
University Eye Hospital, Ludwig-Maximilians-University, Munich, Germany
1 shared publication - Lischke Roman
Department of Ophthalmology Medical University of Innsbruck Innsbruck Austria
1 shared publication
Latest Publications
- 1 August 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (8) , 740-742
Intraocular lens power calculation accuracy after keratorefractive lenticule extraction with the novel ESCRS post-keratorefractive surgery calculator
Purpose: To compare IOL power calculation accuracy after keratorefractive lenticule extraction (KLEx) using the ESCRS online calculator versus ray tracing, the current gold standard. Setting: Multicenter study at Ludwig-Maximilians-University Eye Hospital (Munich, Germany) and SMILE Eyes Clinics (Germany, Austria). Design: Multicenter, cross-sectional study. Methods: Patients who underwent SMILE (KLEx) and subsequent cataract surgery were included. Post-hoc IOL power calculations were performed using ray tracing (Okulix) and the ESCRS calculator (Barrett True-K post-LVC, Hoffer-QST post-LVC, EVO post-LVC). Accuracy, trueness, and precision were compared descriptively. Results: Seven eyes from seven patients were analyzed. EVO post-LVC showed the lowest mean error (-0.24±0.50D), followed by ray tracing (-0.28±0.32D) and Hoffer-QST post-LVC (-0.36±0.59D). Ray tracing, EVO post-LVC and Barrett True-K post-LVC achieved 100% accuracy within ±1.00D. Ray tracing had the lowest mean absolute error (0.35D). Conclusions: Ray tracing and ESCRS post-LVC formulas improve IOL power calculations, emphasizing the need for tailored approaches in post-KLEx eyes.
- 1 August 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (8) , 740-742
Intraocular lens power calculation accuracy after keratorefractive lenticule extraction with the novel ESCRS post-keratorefractive surgery calculator
Purpose: To compare IOL power calculation accuracy after keratorefractive lenticule extraction (KLEx) using the ESCRS online calculator versus ray tracing, the current gold standard. Setting: Multicenter study at Ludwig-Maximilians-University Eye Hospital (Munich, Germany) and SMILE Eyes Clinics (Germany, Austria). Design: Multicenter, cross-sectional study. Methods: Patients who underwent SMILE (KLEx) and subsequent cataract surgery were included. Post-hoc IOL power calculations were performed using ray tracing (Okulix) and the ESCRS calculator (Barrett True-K post-LVC, Hoffer-QST post-LVC, EVO post-LVC). Accuracy, trueness, and precision were compared descriptively. Results: Seven eyes from seven patients were analyzed. EVO post-LVC showed the lowest mean error (-0.24±0.50D), followed by ray tracing (-0.28±0.32D) and Hoffer-QST post-LVC (-0.36±0.59D). Ray tracing, EVO post-LVC and Barrett True-K post-LVC achieved 100% accuracy within ±1.00D. Ray tracing had the lowest mean absolute error (0.35D). Conclusions: Ray tracing and ESCRS post-LVC formulas improve IOL power calculations, emphasizing the need for tailored approaches in post-KLEx eyes.
- 31 March 2023
- Published by Springer Nature
- p. 447-453
Übersicht zu phaken Intraokularlinsen und ihrer Indikationsstellung
- 31 March 2023
- Published by Springer Nature
- p. 447-453
Übersicht zu phaken Intraokularlinsen und ihrer Indikationsstellung
- Open Access
- 29 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4418
IOL Power Calculations and Cataract Surgery in Eyes with Previous Small Incision Lenticule Extraction
Small incision lenticule extraction (SMILE), with over 5 million procedures globally performed, will challenge ophthalmologists in the foreseeable future with accurate intraocular lens power calculations in an ageing population. After more than one decade since the introduction of SMILE, only one case report of cataract surgery with IOL implantation after SMILE is present in the peer-reviewed literature. Hence, the scope of the present multicenter study was to compare the IOL power calculation accuracy in post-SMILE eyes between ray tracing and a range of empirically optimized formulae available in the ASCRS post-keratorefractive surgery IOL power online calculator. In our study of 11 post-SMILE eyes undergoing cataract surgery, ray tracing showed the smallest mean absolute error (0.40 D) and yielded the largest percentage of eyes within ±0.50/±1.00 D (82/91%). The next best conventional formula was the Potvin–Hill formula with a mean absolute error of 0.66 D and an ±0.50/±1.00 D accuracy of 45 and 73%, respectively. Analyzing this first cohort of post-SMILE eyes undergoing cataract surgery and IOL implantation, ray tracing showed superior predictability in IOL power calculation over empirically optimized IOL power calculation formulae that were originally intended for use after Excimer-based keratorefractive procedures.
- 29 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4418
Open AccessIOL Power Calculations and Cataract Surgery in Eyes with Previous Small Incision Lenticule Extraction
Small incision lenticule extraction (SMILE), with over 5 million procedures globally performed, will challenge ophthalmologists in the foreseeable future with accurate intraocular lens power calculations in an ageing population. After more than one decade since the introduction of SMILE, only one case report of cataract surgery with IOL implantation after SMILE is present in the peer-reviewed literature. Hence, the scope of the present multicenter study was to compare the IOL power calculation accuracy in post-SMILE eyes between ray tracing and a range of empirically optimized formulae available in the ASCRS post-keratorefractive surgery IOL power online calculator. In our study of 11 post-SMILE eyes undergoing cataract surgery, ray tracing showed the smallest mean absolute error (0.40 D) and yielded the largest percentage of eyes within ±0.50/±1.00 D (82/91%). The next best conventional formula was the Potvin–Hill formula with a mean absolute error of 0.66 D and an ±0.50/±1.00 D accuracy of 45 and 73%, respectively. Analyzing this first cohort of post-SMILE eyes undergoing cataract surgery and IOL implantation, ray tracing showed superior predictability in IOL power calculation over empirically optimized IOL power calculation formulae that were originally intended for use after Excimer-based keratorefractive procedures.