Filipa Adzic
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Filipa Adzic has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Liora Malki-Epshtein
Department of Civil, Environmental and Geomatic Engineering, University College London, London, UK
5 shared publications - Oliver Wild4 shared publications
- Christopher Iddon
University of Nottingham, Nottingham, UK
3 shared publications - Ben M. Roberts
Loughborough University, UK
2 shared publications - Malcolm Cook
Department of Civil and Building Engineering, Loughborough University, Loughborough, UK
2 shared publications - Ailsa Hamilton-Smith
GHD Co, Movement Strategies, London, England
1 shared publication
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in SSRN Electronic Journal
Impact of Active Ventilation Strategies on Air Quality for Evidence-Based Car Park Design
Air quality management is a significant challenge in enclosed car parks due to the presence of numerous pollution sources, with negative health impacts for both workers exposed over long periods and users exposed to short spikes. The considerable variability in the design and airflow conditions of underground parking facilities has made it difficult to draw systematic conclusions from isolated field measurements. This study presents the first series of air quality experiments with pollutants in the Controlled Active Ventilation Environment laboratory, a large-scale facility dedicated to investigating indoor environmental quality and building resilience. Using two vehicles, cold-start emissions typical of parking garage manoeuvres are characterised, revealing significant discrepancies from nominal operations. Nine building response experiments are then conducted with each vehicle idling alone or together under three ventilation regimes: no ventilation, recirculating ventilation, and introduction of outside air. Using an array of sensors, the concentrations of CO₂, CO, O₃, NO₂, SO₂, PM1, PM2.5, and PM10 are measured in both near-field and far-field locations to assess air quality dynamics. This systematic analysis identifies major near- and far-field pollutants under these scenarios and quantifies the effectiveness of each ventilation scenario, offering valuable insights to improve air quality and protect occupant health by optimising car park sensor choice, location, and ventilation design.
- 24 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessImpact of Active Ventilation Strategies on Air Quality for Evidence-Based Car Park Design
Air quality management is a significant challenge in enclosed car parks due to the presence of numerous pollution sources, with negative health impacts for both workers exposed over long periods and users exposed to short spikes. The considerable variability in the design and airflow conditions of underground parking facilities has made it difficult to draw systematic conclusions from isolated field measurements. This study presents the first series of air quality experiments with pollutants in the Controlled Active Ventilation Environment laboratory, a large-scale facility dedicated to investigating indoor environmental quality and building resilience. Using two vehicles, cold-start emissions typical of parking garage manoeuvres are characterised, revealing significant discrepancies from nominal operations. Nine building response experiments are then conducted with each vehicle idling alone or together under three ventilation regimes: no ventilation, recirculating ventilation, and introduction of outside air. Using an array of sensors, the concentrations of CO₂, CO, O₃, NO₂, SO₂, PM1, PM2.5, and PM10 are measured in both near-field and far-field locations to assess air quality dynamics. This systematic analysis identifies major near- and far-field pollutants under these scenarios and quantifies the effectiveness of each ventilation scenario, offering valuable insights to improve air quality and protect occupant health by optimising car park sensor choice, location, and ventilation design.
- Open Access
- 9 August 2026
- Published by Elsevier in SSRN Electronic Journal
Balancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear. This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems. Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy. These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- 9 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBalancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear. This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems. Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy. These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- Open Access
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
Balancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear.This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems.Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy.These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBalancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear.This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems.Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy.These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- Open Access
- 8 October 2025
- Published by Elsevier in Building and Environment
- Vol. 287
Air quality at mass gatherings: assessing ventilation and occupancy in marquees to evaluate airborne infection risk during the COVID-19 pandemic
- 8 October 2025
- Published by Elsevier in Building and Environment
- Vol. 287
Open AccessAir quality at mass gatherings: assessing ventilation and occupancy in marquees to evaluate airborne infection risk during the COVID-19 pandemic
- Open Access
- 16 December 2022
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 44 (2) , 113-133
Measurement and rapid assessment of indoor air quality at mass gathering events to assess ventilation performance and reduce aerosol transmission of SARS-CoV-2
To assess risk factors for COVID-19 transmission and address the closure of mass gathering events since March 2020, the UK Government ran the Events Research Programme (ERP), following which it reopened live events in sports, music, and culture in July 2021. We report the rapid post-occupancy evaluation of Indoor Air Quality (IAQ) and associated long-range airborne transmission risk conducted in the Environmental Study of the ERP. Ten large venues around the UK were monitored with CO 2 sensors at a high spatial and temporal resolution during 90 events. An IAQ Index based on CO 2 concentration was developed, and all monitored spaces were classified in bands from A to G based on their average and maximum CO 2 concentrations from all events. High resolution monitoring and the IAQ Index depicted the overall state of ventilation at live events, and allowed identification of issues with ventilation effectiveness and distribution, and of spaces with poor ventilation and the settings in which long-range airborne transmission risk may be increased. In numerous settings, CO 2 concentrations were found to follow patterns relating to event management and specific occupancy of spaces around the venues. Good ventilation was observed in 90% of spaces monitored for given occupancies. Practical applications: High-resolution monitoring of indoor CO 2 concentrations is necessary to detect the spatial variation of indoor air quality (IAQ) in large mass gathering event venues. The paper summarises COVID-19 ventilation guidance for buildings and defines a methodology for measurement and rapid assessment of IAQ during occupancy at live events that can be implemented by venue managers. Comparisons of the CO 2 concentrations measured during the events identified the spaces at high risk of long-range transmission of airborne pathogens. Building operators should be mindful of the ventilation strategies used relative to the total occupancy in different spaces and the occupant’s activities.
- 16 December 2022
- Published by SAGE Publications in Building Services Engineering Research & Technology
- Vol. 44 (2) , 113-133
Open AccessMeasurement and rapid assessment of indoor air quality at mass gathering events to assess ventilation performance and reduce aerosol transmission of SARS-CoV-2
To assess risk factors for COVID-19 transmission and address the closure of mass gathering events since March 2020, the UK Government ran the Events Research Programme (ERP), following which it reopened live events in sports, music, and culture in July 2021. We report the rapid post-occupancy evaluation of Indoor Air Quality (IAQ) and associated long-range airborne transmission risk conducted in the Environmental Study of the ERP. Ten large venues around the UK were monitored with CO 2 sensors at a high spatial and temporal resolution during 90 events. An IAQ Index based on CO 2 concentration was developed, and all monitored spaces were classified in bands from A to G based on their average and maximum CO 2 concentrations from all events. High resolution monitoring and the IAQ Index depicted the overall state of ventilation at live events, and allowed identification of issues with ventilation effectiveness and distribution, and of spaces with poor ventilation and the settings in which long-range airborne transmission risk may be increased. In numerous settings, CO 2 concentrations were found to follow patterns relating to event management and specific occupancy of spaces around the venues. Good ventilation was observed in 90% of spaces monitored for given occupancies. Practical applications: High-resolution monitoring of indoor CO 2 concentrations is necessary to detect the spatial variation of indoor air quality (IAQ) in large mass gathering event venues. The paper summarises COVID-19 ventilation guidance for buildings and defines a methodology for measurement and rapid assessment of IAQ during occupancy at live events that can be implemented by venue managers. Comparisons of the CO 2 concentrations measured during the events identified the spaces at high risk of long-range transmission of airborne pathogens. Building operators should be mindful of the ventilation strategies used relative to the total occupancy in different spaces and the occupant’s activities.
- Open Access
- 31 July 2022
- Published by Elsevier in Building and Environment
- Vol. 223, 109392
A post-occupancy study of ventilation effectiveness from high-resolution CO2 monitoring at live theatre events to mitigate airborne transmission of SARS-CoV-2
- 31 July 2022
- Published by Elsevier in Building and Environment
- Vol. 223, 109392
Open AccessA post-occupancy study of ventilation effectiveness from high-resolution CO2 monitoring at live theatre events to mitigate airborne transmission of SARS-CoV-2
- Open Access
- 16 June 2022
- Published by Taylor & Francis in Journal of Hydraulic Research
- Vol. 60 (4) , 628-644
Large-eddy simulation of supercritical free-surface flow in an open-channel contraction
Large-eddy simulations (LES) of supercritical flow in a straight-wall, open-channel contraction of 6° and contraction ratio of 2:1 are performed. The LES code solves the filtered Navier-Stokes equations for two-phase flows (water-air) and employs the level-set method. The simulation was validated by replicating a previously reported experiment. Contours of the time-averaged velocities indicate that the flow loses energy and momentum in the contracting channel. Further, secondary currents in the contraction are redistributing momentum and are responsible for local up-and down-flows. The turbulent kinetic energy reaches very high values at the entrance of the contraction, mainly contributed by the streamwise normal stress. The flow contains coherent turbulence structures which are responsible for carrying low-momentum from the bed and the water surface towards the channel centre. Flow deceleration results in significant turbulence anisotropy in the contracted section. It is shown that mainly pressure drag contributes to the energy loss in the contraction.
- 16 June 2022
- Published by Taylor & Francis in Journal of Hydraulic Research
- Vol. 60 (4) , 628-644
Open AccessLarge-eddy simulation of supercritical free-surface flow in an open-channel contraction
Large-eddy simulations (LES) of supercritical flow in a straight-wall, open-channel contraction of 6° and contraction ratio of 2:1 are performed. The LES code solves the filtered Navier-Stokes equations for two-phase flows (water-air) and employs the level-set method. The simulation was validated by replicating a previously reported experiment. Contours of the time-averaged velocities indicate that the flow loses energy and momentum in the contracting channel. Further, secondary currents in the contraction are redistributing momentum and are responsible for local up-and down-flows. The turbulent kinetic energy reaches very high values at the entrance of the contraction, mainly contributed by the streamwise normal stress. The flow contains coherent turbulence structures which are responsible for carrying low-momentum from the bed and the water surface towards the channel centre. Flow deceleration results in significant turbulence anisotropy in the contracted section. It is shown that mainly pressure drag contributes to the energy loss in the contraction.