FAFilipa Adzic

Filipa Adzic

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Filipa Adzic has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Active Ventilation Strategies on Air Quality for Evidence-Based Car Park Design

    by Augustin Guibaud, Filipa Adzic, Yutao Li, Oliver Wild, Christopher Iddon, Liora Malki-Epshtein

    Air quality management is a significant challenge in enclosed car parks due to the presence of numerous pollution sources, with negative health impacts for both workers exposed over long periods and users exposed to short spikes. The considerable variability in the design and airflow conditions of underground parking facilities has made it difficult to draw systematic conclusions from isolated field measurements. This study presents the first series of air quality experiments with pollutants in the Controlled Active Ventilation Environment laboratory, a large-scale facility dedicated to investigating indoor environmental quality and building resilience. Using two vehicles, cold-start emissions typical of parking garage manoeuvres are characterised, revealing significant discrepancies from nominal operations. Nine building response experiments are then conducted with each vehicle idling alone or together under three ventilation regimes: no ventilation, recirculating ventilation, and introduction of outside air. Using an array of sensors, the concentrations of CO₂, CO, O₃, NO₂, SO₂, PM1, PM2.5, and PM10 are measured in both near-field and far-field locations to assess air quality dynamics. This systematic analysis identifies major near- and far-field pollutants under these scenarios and quantifies the effectiveness of each ventilation scenario, offering valuable insights to improve air quality and protect occupant health by optimising car park sensor choice, location, and ventilation design.

  • Open Access

    Balancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses

    by Oliver Wild, Filipa Adzic, Liora Malki-Epshtein

    London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear. This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems. Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy. These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.

  • Open Access

    Balancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses

    by Oliver Wild, Filipa Adzic, Liora Malki-Epshtein

    London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear.This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems.Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy.These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.

  • Open Access

    Air quality at mass gatherings: assessing ventilation and occupancy in marquees to evaluate airborne infection risk during the COVID-19 pandemic

    by Ben M. Roberts, Filipa Adzic, Ailsa Hamilton-Smith, Christopher Iddon, Oliver Wild, Malcolm Cook, Steve Gwynne, Aoife Hunt, Liora Malki-Epshtein

  • Open Access

    Measurement and rapid assessment of indoor air quality at mass gathering events to assess ventilation performance and reduce aerosol transmission of SARS-CoV-2

    by Liora Malki-Epshtein, Filipa Adzic, Ben M Roberts, Elizabeth Abigail Hathway, Christopher Iddon, Murat Mustafa, Malcolm Cook

    To assess risk factors for COVID-19 transmission and address the closure of mass gathering events since March 2020, the UK Government ran the Events Research Programme (ERP), following which it reopened live events in sports, music, and culture in July 2021. We report the rapid post-occupancy evaluation of Indoor Air Quality (IAQ) and associated long-range airborne transmission risk conducted in the Environmental Study of the ERP. Ten large venues around the UK were monitored with CO 2 sensors at a high spatial and temporal resolution during 90 events. An IAQ Index based on CO 2 concentration was developed, and all monitored spaces were classified in bands from A to G based on their average and maximum CO 2 concentrations from all events. High resolution monitoring and the IAQ Index depicted the overall state of ventilation at live events, and allowed identification of issues with ventilation effectiveness and distribution, and of spaces with poor ventilation and the settings in which long-range airborne transmission risk may be increased. In numerous settings, CO 2 concentrations were found to follow patterns relating to event management and specific occupancy of spaces around the venues. Good ventilation was observed in 90% of spaces monitored for given occupancies. Practical applications: High-resolution monitoring of indoor CO 2 concentrations is necessary to detect the spatial variation of indoor air quality (IAQ) in large mass gathering event venues. The paper summarises COVID-19 ventilation guidance for buildings and defines a methodology for measurement and rapid assessment of IAQ during occupancy at live events that can be implemented by venue managers. Comparisons of the CO 2 concentrations measured during the events identified the spaces at high risk of long-range transmission of airborne pathogens. Building operators should be mindful of the ventilation strategies used relative to the total occupancy in different spaces and the occupant’s activities.


  • Open Access

    A post-occupancy study of ventilation effectiveness from high-resolution CO2 monitoring at live theatre events to mitigate airborne transmission of SARS-CoV-2

    by Filipa Adzic, Ben M. Roberts, Elizabeth Abigail Hathway, Rupy Kaur Matharu, Lena Ciric, Oliver Wild, Malcolm Cook, Liora Malki-Epshtein


  • Open Access

    Large-eddy simulation of supercritical free-surface flow in an open-channel contraction

    by Filipa Adzic, Thorsten Stoesser, Yan Liu, Zhihua Xie

    Large-eddy simulations (LES) of supercritical flow in a straight-wall, open-channel contraction of 6° and contraction ratio of 2:1 are performed. The LES code solves the filtered Navier-Stokes equations for two-phase flows (water-air) and employs the level-set method. The simulation was validated by replicating a previously reported experiment. Contours of the time-averaged velocities indicate that the flow loses energy and momentum in the contracting channel. Further, secondary currents in the contraction are redistributing momentum and are responsible for local up-and down-flows. The turbulent kinetic energy reaches very high values at the entrance of the contraction, mainly contributed by the streamwise normal stress. The flow contains coherent turbulence structures which are responsible for carrying low-momentum from the bed and the water surface towards the channel centre. Flow deceleration results in significant turbulence anisotropy in the contracted section. It is shown that mainly pressure drag contributes to the energy loss in the contraction.