Oliver Wild
Research Subjects
Oliver Wild has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Filipa Adzic
Department of Civil, Environmental and Geomatic Engineering, University College London, London, UK
4 shared publications - Liora Malki-Epshtein
Department of Civil, Environmental and Geomatic Engineering, University College London, London, UK
4 shared publications - Christopher Iddon
University of Nottingham, Nottingham, UK
2 shared publications - Ailsa Hamilton-Smith
GHD Co, Movement Strategies, London, England
1 shared publication - Aoife Hunt
GHD Co, Movement Strategies, London, England
1 shared publication - Augustin Guibaud
ANYU Tandon School of Engineering, Brooklyn, NY 11201, USA
1 shared publication
Latest Publications
- Open Access
- 24 October 2026
- Published by Elsevier in SSRN Electronic Journal
Impact of Active Ventilation Strategies on Air Quality for Evidence-Based Car Park Design
Air quality management is a significant challenge in enclosed car parks due to the presence of numerous pollution sources, with negative health impacts for both workers exposed over long periods and users exposed to short spikes. The considerable variability in the design and airflow conditions of underground parking facilities has made it difficult to draw systematic conclusions from isolated field measurements. This study presents the first series of air quality experiments with pollutants in the Controlled Active Ventilation Environment laboratory, a large-scale facility dedicated to investigating indoor environmental quality and building resilience. Using two vehicles, cold-start emissions typical of parking garage manoeuvres are characterised, revealing significant discrepancies from nominal operations. Nine building response experiments are then conducted with each vehicle idling alone or together under three ventilation regimes: no ventilation, recirculating ventilation, and introduction of outside air. Using an array of sensors, the concentrations of CO₂, CO, O₃, NO₂, SO₂, PM1, PM2.5, and PM10 are measured in both near-field and far-field locations to assess air quality dynamics. This systematic analysis identifies major near- and far-field pollutants under these scenarios and quantifies the effectiveness of each ventilation scenario, offering valuable insights to improve air quality and protect occupant health by optimising car park sensor choice, location, and ventilation design.
- 24 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessImpact of Active Ventilation Strategies on Air Quality for Evidence-Based Car Park Design
Air quality management is a significant challenge in enclosed car parks due to the presence of numerous pollution sources, with negative health impacts for both workers exposed over long periods and users exposed to short spikes. The considerable variability in the design and airflow conditions of underground parking facilities has made it difficult to draw systematic conclusions from isolated field measurements. This study presents the first series of air quality experiments with pollutants in the Controlled Active Ventilation Environment laboratory, a large-scale facility dedicated to investigating indoor environmental quality and building resilience. Using two vehicles, cold-start emissions typical of parking garage manoeuvres are characterised, revealing significant discrepancies from nominal operations. Nine building response experiments are then conducted with each vehicle idling alone or together under three ventilation regimes: no ventilation, recirculating ventilation, and introduction of outside air. Using an array of sensors, the concentrations of CO₂, CO, O₃, NO₂, SO₂, PM1, PM2.5, and PM10 are measured in both near-field and far-field locations to assess air quality dynamics. This systematic analysis identifies major near- and far-field pollutants under these scenarios and quantifies the effectiveness of each ventilation scenario, offering valuable insights to improve air quality and protect occupant health by optimising car park sensor choice, location, and ventilation design.
- Open Access
- 9 August 2026
- Published by Elsevier in SSRN Electronic Journal
Balancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear. This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems. Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy. These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- 9 August 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBalancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear. This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems. Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy. These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- Open Access
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
Balancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear.This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems.Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy.These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- 10 June 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessBalancing Ventilation, Thermal Comfort and Energy Efficiency in Urban Buses: Evidence from Long-Term Monitoring of Operational London Buses
London’s public transport provides metropolitan mobility that is widely depended on as a socioeconomically accessible and energy efficient alternative to private vehicles. The COVID-19 pandemic prompted enhanced ventilation strategies on public transport to reduce airborne disease transmission. However, the implications of these interventions on energy consumption remain unclear.This study evaluates a natural ventilation strategy implemented by Transport for London (TfL) on all London buses in May 2021 to impose partially open windows with fixed blocks. 15 operational London buses were monitored for temperatures and CO2 concentrations on the passenger cabins over a five-month period spanning summer and winter, to quantify periods of poor air quality, and associated triggering of the heating and cooling systems.Elevated CO₂ concentrations were found to be strongly associated with rush hours, representing 20% of operational time and generating 70% of high CO₂ episodes (>1500 ppm). During these highly occupied periods, window blocks reduced the occurrence of high-range CO₂ episodes by up to 55%, improving passenger air quality. However, the increased natural ventilation affected thermal regulation. During summer and winter, buses fitted with window blocks experienced more frequent episodes of extreme temperatures, increasing reliance on onboard heating and cooling systems as set by the buses’ HVAC strategy.These findings reveal a clear trade-off between ventilation performance, thermal comfort, and energy efficiency, and recommends adopting adaptive ventilation strategies to preserve the operational range of electric bus fleets. The study has informed TfL’s bus ventilation strategy, which was implemented on all electric buses in London.
- Open Access
- 8 October 2025
- Published by Elsevier in Building and Environment
- Vol. 287
Air quality at mass gatherings: assessing ventilation and occupancy in marquees to evaluate airborne infection risk during the COVID-19 pandemic
- 8 October 2025
- Published by Elsevier in Building and Environment
- Vol. 287
Open AccessAir quality at mass gatherings: assessing ventilation and occupancy in marquees to evaluate airborne infection risk during the COVID-19 pandemic