YWYoshitaka Wada

Yoshitaka Wada

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yoshitaka Wada has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Surgical results of retroauricular fascia graft in frontalis suspension surgery: A case series study

    by Kazuki Ueno, Yuji Shirakawa, Kazuhisa Uemura, Shinji Kumegawa, Yoshitaka Wada, Shinichi Asamura


  • Open Access

    Study to the Effect of Involutional Blepharoptosis Surgery Using Objective and Subjective Parameters

    by Shinichi Asamura, Yoshitaka Wada, Saiichi Tanaka, Shizuya Saika

    Background We investigate the effect of involutional blepharoptosis (IB) surgery based on dry eye symptoms by analysis using objective and subjective measures. Methods We recorded various parameters from patients that underwent levator advancement surgery for IB, totaling 125 eyes (total 65 patients, 5 unilateral, 60 bilateral). Subjective assessment comprised a questionnaire on dry eye-related quality of life score (DEQS), a summary score calculated from DEQS, and six-grade evaluation, the patient's own measure of eye comfort. Objective assessment comprised marginal-reflex distance-1 (MRD-1), measurement of tear film breakup time, and superficial keratopathy (SPK) existence by slit lamp microscope. Results Subjective assessments showed that IB patients had improvement of dry eye symptoms and eye comfort when surgery increased MRD-1. On the other hand, objective assessments showed that the presence of SPK is suspected when the postoperative MRD-1 level is 3 mm or higher. Conclusion IB surgery must not only increase MRD-1 value, but also to perform maintenance of the appropriate ocular surface condition. From our parameters, we suggest postoperative MRD-1 value should be maintained at < 3 mm to safe and effective of IB surgery.


  • Open Access

    Prediction for interaction of fatigue crack propagation using convolutional neural network with data augmentation

    by Yoshitaka Wada

    This study presents the capability and applicability for fatigue crack propagation evaluation using a convolutional neural network system. Fatigue crack propagation includes several governing laws and computation methods which are elastic stress field, stress intensity factors, Paris’ law and criterion of crack propagation direction. Crack propagation phenomenon simultaneously

  • Swinging Eyelid Approach to Zygomaticomaxillary Complex Fracture

    by Hidetaka Miyazaki, Katsuya Okuda, Kazuki Ueno, Yoshitaka Wada, Shinji Kumegawa, Kazuhisa Uemura, Yasuhiro Sakata, Shinichi Asamura

    A surgical approach to zygomaticomaxillary complex (ZMC) fracture has not been standardized. The authors reviewed 15 cases of ZMC fractures treated with the swinging eyelid approach and evaluated the effectiveness of the technique by an observational study of Japanese patients. Results were assessed from authentic and functional perspectives: the presence of entropion/ectropion, external canthal malposition and chemosis of the conjunctiva. After a minimum follow-up of 10 months, no patients had lower eyelid ectropion, entropion or retraction. Wounds appeared inconspicuous, and a lateral canthal shape was preserved. No post-operative chemosis of the conjunctiva was observed. Each case was evaluated based on patient satisfaction about their aesthetic outcomes. Patient self-assessment is classified into 4 groups (excellent, good, fair, and unsatisfactory). Thirteen patients were assessed to have an “excellent” outcome, and 2 patients were assessed to have a “good” outcome. No patients had “fair” or “unsatisfactory” outcomes. Avoidance of scarring is a goal of every craniofacial surgeon. The swinging eyelid approach to ZMC fractures offers a simple alternative to the conventional technique. It is versatile and provides sufficient exposure to surgical fields with less visible scar because skin incision is made along the natural crease line, “the crow's feet.”


  • Study of parameters to develop fracture criterion under low cycle fatigue

    by Yoshitaka Wada, Yuto Ohbayashi

    In order to keep a safe operation a light water reactor plant, it is necessary to evaluate integrity of a pipe under the assumption of seismic load and a behavior of a crack in a pipe under the load more than the design load. In previous research,a validity of crack propagation criterion using stress triaxiality and equivalent plastic strain under monotonic loading case is exhibited.However,since it is unusual that only monotonic loading occur,it is necessary to consider dynamic loading.Objective of research is to study of fracture criterion using stress triaxiality and equivalent plastic strain for cracked pipes under cyclic loading stress compared with J integral which is an existing fracture parameter.For development of fracture criterion,to do FE analysis using fracture test of cracked pipes by CRIEPI.The conditions of an analysis is almost the same as T47 report by CRIEPI.Due to increase the amplitude load,ΔJ and hysteresis loop was overestimated in analysis.So,it is review the stress - strain curve to increase the precision of analysis.The maximum value of equivalent plastic strain increase as a number of step.In this case,there is a possibility that fracture criterion has a high contribution of equivalent plastic strain.It is necessary to evaluate the validity of parameter and criterion by application phase analysis.

  • Evaluation of stress triaxiality and equivalent plastic strain distributions with very large scale yielding under monotonic loading

    by Yoshitaka Wada, Yuka Mitsumasu

    Fracture mechanics has revealed the knowledge of strength of materials including cracks under monotonic and cyclic loadings. The powerfulness of fracture mechanics is clear theory and very useful fracture mechanics parameters, however J integral has the limitation of monotonic loading and small scale yielding. In recent years, advances in computer simulation technology have made it possible to perform complex 3-dimensional finite element analysis and to calculate elastic-plastic states of a crack tip using the actual material property. We have employed the combination parameter of stress triaxiality, which is related to ductile fracture, and equivalent plastic strain, which becomes a fracture parameter under plane stress state, for fundamental parameters in order to describe fracture criterion under the large scale yielding. The parameter is not enough for cyclic loading case as crack propagation criterion. Various studies are in progress with these. In this study, stress and plastic stress distribution are evaluated in detail using elastic-plastic finite element analysis. The analysis model uses a 1/4 unidirectional tension model. We perform tension and three point bending analysis on the model and loading condition is a monotonic loading. Crack propagation direction and crack propagation condition will be well examined in comparison with the past studies for large scale yielding. The analysis results show that the stress triaxiality value is the highest at the center of the specimen thickness. By comparing the results of the past research and the result, we are able to confirm the validity of the analysis model used in this research.

  • Error Reduction Technique Considering Uneven Brightness Based on Area by Brightness Correction for Full Field Strain Measurement

    by Yoshitaka Wada, Yushi Nakamura

    Stiffness of structures for long time operation gradually decreases by stress or strain cyclic loading. Full field strain measurement technique can determine the distribution of decrement of the stiffness or a degree of material damage. Since the error occurs due to several noise source, 0.1% strain becomes a measurement limit. Digital Image Correlation (DIC) has been well studied and employed for such a strain measurement, however DIC needs random dot pattern, complete uniform lighting and computation time for wide view. Accordingly, the authors have employed Dot Centroid Tracking (DCT) at high speed and with high accuracy. DCT can be measured with minimal image processing and centroid location computation. The objective of this study is a determination of a dot mark size and the distance to keep accuracy of the measurement at 0.01% strain. An object with four dots is illuminated with light and photographed with a digital camera to obtain an average value. Based on the average value of the coordinates of 4 points obtained, Bayesian estimation is performed with a small number of sheets, and the average and variance are determined and expressed as a probability density function. We determine the dot size at which 0.01% strain can be measured by changing the dot radius and the distance between centroid.

  • Fracture Toughness Experiment for Numerical Analysis Ductile Fracture

    by Rekisei Ozawa, Yoshitaka Wada

    Decrement of the engineering popular in Japan causes a risk of maintaining infrastructures inappropriately. Integrity of nuclear power plants is one of the most urgent issues to keep a stability of a generation of electrical energy. In order to accurately evaluate a stability of a generation of electrical energy, supposing even a seismic load, a fracture behavior with a large plastic area must be grasped. J-integral has application limit. J-integral cannot evaluate a fracture behavior with a large plastic area. Physical quantities and constitutive equation that can evaluate fracture behavior with a large plastic area are studied. A ductile fracture under very low cycle fatigue and monotonic load increasing is mainly investigated with some specimen size and shape in numerical analysis. However, comparison and examination of numerical analysis and experiment are not sufficiently conducted. In order to set a boundary conditions in numerical analysis correctly, to measure a situation of an experiment precisely is important. In this study, a fracture toughness test of a three points bending is performed under monotonic load increasing with SEN(B) specimen of stainless steel SUS304. Crack growth length, crack front shape, deformation of specimen, load and load point displacement is taken measurement. These are for the generation phase analysis, i.e., precise measurement results in the experiment are useful for boundary conditions in a numerical simulation. In the three points bending test, a plastic deformation near a load point and a load direction for the SEN(B) specimen are obtained for FE analysis.

  • Open Access

    Tissue engineering a human phalanx

    by W. J. Landis, S. Chubinskaya, T. Tokui, Y. Wada, N. Isogai, R. Jacquet

    A principal purpose of tissue engineering is the augmentation, repair or replacement of diseased or injured human tissue. This study was undertaken to determine whether human biopsies as a cell source could be utilized for successful engineering of human phalanges consisting of both bone and cartilage. This paper reports the use of cadaveric human chondrocytes and periosteum as a model for the development of phalanx constructs. Two factors, osteogenic protein-1 [OP-1/bone morphogenetic protein-7 (BMP7)], alone or combined with insulin-like growth factor (IGF-1), were examined for their potential enhancement of chondrocytes and their secreted extracellular matrices. Design of the study included culture of chondrocytes and periosteum on biodegradable polyglycolic acid (PGA) and poly-l-lactic acid (PLLA)–poly-ε-caprolactone (PCL) scaffolds and subsequent implantation in athymic nu/nu (nude) mice for 5, 20, 40 and 60 weeks. Engineered constructs retrieved from mice were characterized with regard to genotype and phenotype as a function of developmental (implantation) time. Assessments included gross observation, X-ray radiography or microcomputed tomography, histology and gene expression. The resulting data showed that human cell-scaffold constructs could be successfully developed over 60 weeks, despite variability in donor age. Cartilage formation of the distal phalanx models enhanced with both OP-1 and IGF-1 yielded more cells and extracellular matrix (collagen and proteoglycans) than control chondrocytes without added factors. Summary data demonstrated that human distal phalanx models utilizing cadaveric chondrocytes and periosteum were successfully fabricated and OP-1 and OP-1/IGF-1 accelerated construct development and mineralization. The results suggest that similar engineering and transplantation of human autologous tissues in patients are clinically feasible. Copyright © 2016 John Wiley & Sons, Ltd.