Ahmed Nasser B. Alsammak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ahmed Nasser B. Alsammak has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Ibrahim Ismael Alnaib
University of Mosul
7 shared publications Hasan A. Mohammed
4 shared publications- Muhammed A. Ibrahim
Ninevah University
3 shared publications Ahmed Yahya Qasim
2 shared publications- Basim Mohammed A. Anwer
Department of Electrical Engineering, University of Mosul, Mosul, Iraq, Iraq
2 shared publications Fadhil R. Tahir
2 shared publications
Latest Publications
- Open Access
- 2 November 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 6,p. 40-49
Cooperative fuzzy logic-based on-load tap changer control system and photovoltaic smart inverter control for voltage regulation in high penetration distribution networks
Introduction. The integration of photovoltaic (PV) systems into the conventional power system is one of the most promising approaches for efficiently meeting increasing energy demand. Problem. The increasing installation of PV systems makes significant challenges for voltage regulation due to non-continuous generation and two-way power flow. A conventional on-load tap changer (OLTC) control system, designed for operation in unidirectional power systems, cannot ensure voltage quality at all buses with high PV penetration. Goal. To develop a cooperative voltage regulation strategy that uses a fuzzy logic controller (FLC)-based OLTC, together with the active and reactive power control capabilities of PV smart inverters, to improve voltage regulation in high PV penetration distribution networks. An intelligent FLC is used to determine the optimal OLTC tap position, thereby quickly addressing voltage regulation issues and reducing unnecessary OLTC tap operations. Methodology. This study models and analyzes a sample radial test system comprising loads, OLTC transformers, and a high-PV-penetration system using MATLAB/Simulink. FLC, which depends on constrained exhaustive search optimization, was designed to regulate the OLTC in response to load, PV penetration, and source voltage. This work dived into 4 scenarios. The first two scenarios included conventional OLTC control with and without a PV system. The third scenario included an intelligent FLC for the OLTC with a full PV penetration. The fourth scenario included FLC with optimal active power penetration and reactive power compensation of PV smart inverters. Results. Simulation results demonstrate the effectiveness of the proposed intelligent control approach in achieving better voltage regulation while maximizing the allowable PV hosting capacity. Scientific novelty. The combining optimization for PV penetration and reactive power compensation with optimal intelligent control of the OLTC. Practical value. This research offers a robust solution for voltage regulation issues in modern power systems. The intelligent system solves voltage problems and implements proactive corrective measures. References 37, figures 28.
- 2 November 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 6,p. 40-49
Open AccessCooperative fuzzy logic-based on-load tap changer control system and photovoltaic smart inverter control for voltage regulation in high penetration distribution networks
Introduction. The integration of photovoltaic (PV) systems into the conventional power system is one of the most promising approaches for efficiently meeting increasing energy demand. Problem. The increasing installation of PV systems makes significant challenges for voltage regulation due to non-continuous generation and two-way power flow. A conventional on-load tap changer (OLTC) control system, designed for operation in unidirectional power systems, cannot ensure voltage quality at all buses with high PV penetration. Goal. To develop a cooperative voltage regulation strategy that uses a fuzzy logic controller (FLC)-based OLTC, together with the active and reactive power control capabilities of PV smart inverters, to improve voltage regulation in high PV penetration distribution networks. An intelligent FLC is used to determine the optimal OLTC tap position, thereby quickly addressing voltage regulation issues and reducing unnecessary OLTC tap operations. Methodology. This study models and analyzes a sample radial test system comprising loads, OLTC transformers, and a high-PV-penetration system using MATLAB/Simulink. FLC, which depends on constrained exhaustive search optimization, was designed to regulate the OLTC in response to load, PV penetration, and source voltage. This work dived into 4 scenarios. The first two scenarios included conventional OLTC control with and without a PV system. The third scenario included an intelligent FLC for the OLTC with a full PV penetration. The fourth scenario included FLC with optimal active power penetration and reactive power compensation of PV smart inverters. Results. Simulation results demonstrate the effectiveness of the proposed intelligent control approach in achieving better voltage regulation while maximizing the allowable PV hosting capacity. Scientific novelty. The combining optimization for PV penetration and reactive power compensation with optimal intelligent control of the OLTC. Practical value. This research offers a robust solution for voltage regulation issues in modern power systems. The intelligent system solves voltage problems and implements proactive corrective measures. References 37, figures 28.
- Open Access
- 4 September 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Stability improvement of integrated solar energy with HVDC and UPFC Systems: A comprehensive review
- 4 September 2026
- Published by Elsevier in Results in Engineering
- Vol. 32
Open AccessStability improvement of integrated solar energy with HVDC and UPFC Systems: A comprehensive review
- Open Access
- 1 July 2026
- Published by MDPI AG in Electricity
- Vol. 7 (3) , 65
Challenges of Transformers OLTC Operation in the Power System That Includes Solar PV Systems and FACTS Devices
An increase in penetration of photovoltaic (PV) systems in a distribution system causes voltage regulation issues that create serious problems for the On-Load Tap Changer (OLTC) of the power transformer, leading to higher tap-changing frequency and reduced transformer life. Traditional voltage control methods are ineffective when PV penetration exceeds load demand, and more sophisticated control methods are needed. This paper combines a systematic literature review conducted in accordance with the PRISMA 2020 guidelines with a case study on operational issues of OLTC transformers under both normal and non-normal operating conditions. It entails a detailed examination of the effect of PV integration on the operating characteristics of OLTC in a systematic approach and also dwells upon coordination processes between OLTC and Flexible AC Transmission Systems (FACTS) devices, such as Distribution Static Synchronous Compensator (D-STATCOM) or Static VAR Compensator (SVC), which are highly effective in reducing tap operations. The future directions covered in the review include the operation of hybrid systems, cost-effective implementations, weather effects, predictive analytics, adaptive control techniques, etc. The case study included online monitoring of OLTC performance in two scenarios at the cement factory. First, under supply changes and load changes. Second, including PV penetration. The results show that OLTC increases the average daily tapping frequency (90 taps/day) by about 60%, with full PV penetration. It is concluded that this can’t be applied without coordinated control among OLTC, D-STATCOM, and PV inverters to maintain transformer life, improve reliability, and provide stable voltage profiles even under highly variable PV generation conditions. These results aim to provide a comprehensive resource for academics and practitioners, facilitating the advancement of advanced voltage control methods to support the transition to sustainable energy systems.
- 1 July 2026
- Published by MDPI AG in Electricity
- Vol. 7 (3) , 65
Open AccessChallenges of Transformers OLTC Operation in the Power System That Includes Solar PV Systems and FACTS Devices
An increase in penetration of photovoltaic (PV) systems in a distribution system causes voltage regulation issues that create serious problems for the On-Load Tap Changer (OLTC) of the power transformer, leading to higher tap-changing frequency and reduced transformer life. Traditional voltage control methods are ineffective when PV penetration exceeds load demand, and more sophisticated control methods are needed. This paper combines a systematic literature review conducted in accordance with the PRISMA 2020 guidelines with a case study on operational issues of OLTC transformers under both normal and non-normal operating conditions. It entails a detailed examination of the effect of PV integration on the operating characteristics of OLTC in a systematic approach and also dwells upon coordination processes between OLTC and Flexible AC Transmission Systems (FACTS) devices, such as Distribution Static Synchronous Compensator (D-STATCOM) or Static VAR Compensator (SVC), which are highly effective in reducing tap operations. The future directions covered in the review include the operation of hybrid systems, cost-effective implementations, weather effects, predictive analytics, adaptive control techniques, etc. The case study included online monitoring of OLTC performance in two scenarios at the cement factory. First, under supply changes and load changes. Second, including PV penetration. The results show that OLTC increases the average daily tapping frequency (90 taps/day) by about 60%, with full PV penetration. It is concluded that this can’t be applied without coordinated control among OLTC, D-STATCOM, and PV inverters to maintain transformer life, improve reliability, and provide stable voltage profiles even under highly variable PV generation conditions. These results aim to provide a comprehensive resource for academics and practitioners, facilitating the advancement of advanced voltage control methods to support the transition to sustainable energy systems.
- Open Access
- 11 May 2026
- Published by MDPI AG in Preprints.org
Adaptive Power Quality Management Using an Optimum and Intelligent Shunt Active Power Filter Conditioner System
A serious problem facing power systems today is the deterioration of power quality (PQ), driven mainly by the widespread use of non-linear loads, such as power electronic converters and adjustable-speed drives. These loads inject harmonic currents into the network, resulting in voltage distortion, increased losses, overheating, and reduced system efficiency. Therefore, harmonic mitigation and reactive power compensation are necessary to ensure stable and reliable operation. This paper presents the development of a Shunt Active Power Filter (SAPF) to become an intelligent Shunt Active Power Filter Conditioner (SAPFC) that operates under different loading conditions (linear, non-linear, or mixed). As a result, a conventional PI controller is upgraded with a Fuzzy Gain Scheduling (FGS) technique optimized by the Whale Optimization Algorithm (WOA) in order to keep the DC-link capacitor voltage stable. In addition, an adaptive instantaneous dq theory is used to produce accurate reference currents. The proposed intelligent SAPFC is implemented and validated in MATLAB-Simulink, where simulation results show maximizing the SAPFC's effectiveness in minimizing harmonic distortion to less than 0.7% and achieving a near-unity power factor under different operating conditions. The integrated SAPFC, with its intelligent control, offers a robust and adaptive solution for improving power quality in modern electrical systems, thereby increasing efficiency and reducing power losses.
- 11 May 2026
- Published by MDPI AG in Preprints.org
Open AccessAdaptive Power Quality Management Using an Optimum and Intelligent Shunt Active Power Filter Conditioner System
A serious problem facing power systems today is the deterioration of power quality (PQ), driven mainly by the widespread use of non-linear loads, such as power electronic converters and adjustable-speed drives. These loads inject harmonic currents into the network, resulting in voltage distortion, increased losses, overheating, and reduced system efficiency. Therefore, harmonic mitigation and reactive power compensation are necessary to ensure stable and reliable operation. This paper presents the development of a Shunt Active Power Filter (SAPF) to become an intelligent Shunt Active Power Filter Conditioner (SAPFC) that operates under different loading conditions (linear, non-linear, or mixed). As a result, a conventional PI controller is upgraded with a Fuzzy Gain Scheduling (FGS) technique optimized by the Whale Optimization Algorithm (WOA) in order to keep the DC-link capacitor voltage stable. In addition, an adaptive instantaneous dq theory is used to produce accurate reference currents. The proposed intelligent SAPFC is implemented and validated in MATLAB-Simulink, where simulation results show maximizing the SAPFC's effectiveness in minimizing harmonic distortion to less than 0.7% and achieving a near-unity power factor under different operating conditions. The integrated SAPFC, with its intelligent control, offers a robust and adaptive solution for improving power quality in modern electrical systems, thereby increasing efficiency and reducing power losses.
- Open Access
- 2 March 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 51-58
Intelligent unified power quality conditioner based photovoltaic to improve grid reliability and mitigate power quality issues
Problem. Electrical distribution networks are plagued by power quality problems, which have a negative impact on sensitive electrical loads. These problems include reactive current, low power factor on the load side, and voltage harmonics, voltage sags and voltage swells on the grid voltage side. To address these issues, a unified power quality conditioner (UPQC) that combines shunt and series compensators is suggested. The goal of the work is to implement a UPQC integrated with a photovoltaic (PV) system to mitigate power quality problems in the power system, and boosting the grid supply through power injection from the PV system. Methodology. One of the less complex and effective ways to improve the grid’s voltage quality is by using the unit vector template generation (UVTG) strategy as the composition technique (UPQC-P) through the UPQC series compensator. The synchronous reference frame (SRF) strategy through the UPQC shunt compensator to improve the current quality on the load side is used. To further optimize the SRF strategy, it is used the snake optimization (SO) to find the optimal values for the PI controller’s parameters. Results. The UPQC-PV is used to mitigation the power quality issues in the grid and loads by UVTG and SRF techniques in series and shunt compensators, respectively. Scientific novelty. The composition technique (UPQC-P) through a series compensator and uses the SO for tuning the PI controller in the shunt compensator. Practical value. This study reduces the total harmonic distortion (THD) in the load voltage to 0.57 %, while the THD in the grid voltage remains at 10 %. It restores the load voltage to its reference value of 230 V during voltage sags (down to 161 V) and swells (up to 300 V) in the grid. Additionally, it mitigates the low power factor on the load side (0.707 lagging) to achieve a unity power factor in grid current, balances the unbalanced load current to a balanced grid current, and enhances grid stability by injecting power from the PV system into the grid. References 33, table 3, figures 7.
- 2 March 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 51-58
Open AccessIntelligent unified power quality conditioner based photovoltaic to improve grid reliability and mitigate power quality issues
Problem. Electrical distribution networks are plagued by power quality problems, which have a negative impact on sensitive electrical loads. These problems include reactive current, low power factor on the load side, and voltage harmonics, voltage sags and voltage swells on the grid voltage side. To address these issues, a unified power quality conditioner (UPQC) that combines shunt and series compensators is suggested. The goal of the work is to implement a UPQC integrated with a photovoltaic (PV) system to mitigate power quality problems in the power system, and boosting the grid supply through power injection from the PV system. Methodology. One of the less complex and effective ways to improve the grid’s voltage quality is by using the unit vector template generation (UVTG) strategy as the composition technique (UPQC-P) through the UPQC series compensator. The synchronous reference frame (SRF) strategy through the UPQC shunt compensator to improve the current quality on the load side is used. To further optimize the SRF strategy, it is used the snake optimization (SO) to find the optimal values for the PI controller’s parameters. Results. The UPQC-PV is used to mitigation the power quality issues in the grid and loads by UVTG and SRF techniques in series and shunt compensators, respectively. Scientific novelty. The composition technique (UPQC-P) through a series compensator and uses the SO for tuning the PI controller in the shunt compensator. Practical value. This study reduces the total harmonic distortion (THD) in the load voltage to 0.57 %, while the THD in the grid voltage remains at 10 %. It restores the load voltage to its reference value of 230 V during voltage sags (down to 161 V) and swells (up to 300 V) in the grid. Additionally, it mitigates the low power factor on the load side (0.707 lagging) to achieve a unity power factor in grid current, balances the unbalanced load current to a balanced grid current, and enhances grid stability by injecting power from the PV system into the grid. References 33, table 3, figures 7.
- Open Access
- 2 January 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 51-62
An integrated series active power filter combined with a PV-battery system based on a fuzzy logic controller to enhance power quality for various linear and non-linear loads
Introduction. Rapid capacity development and the incorporation of new loads are adding complexity to the distribution power system. As a result, the distribution system faces additional power quality issues, particularly with increasingly sensitive equipment and distributed generation. Problem. Modern power systems face escalating power quality degradation due to non-linear loads. Voltage disturbances (sags, swells) and harmonic distortions directly affect the sensitive equipment, causing significant economic losses. The goal of this work is to design, model, and evaluate series active power filters (SAPFs) integrated with energy management for an independent solar storage system, using a multi-stage DC-DC converter. The objective focuses on mitigating voltage harmonics and grid disturbances resulting from diverse loads (linear, non-linear, and combined) and integrating renewable energy (PV). Control is achieved through an intelligent fuzzy logic controller (FLC) and a PI controller to ensure a stable DC voltage and reduce the total harmonic distortion (THD) of the voltage to less than 5 %. Methodology. This study models and analyzes a unique SAPF configuration integrated with a PV-battery storage system utilizing MATLAB/Simulink. Outcomes of the proposed control, wherever the FLC regulates the DC-link voltage reference signals utilize the instantaneous reactive power theory. The suggested methodology entails simulation studies across four scenarios: an analysis of performance to keep voltage components and a comparison of the proposed SAPF performance with existing research on linear, non-linear, and combined loads. Results. Simulation results show the effectiveness of the control approach in mitigating the voltage THD level to less than 5 % under various operating conditions that included the main supply voltage and loads, which satisfies the international PQ standards (IEEE Std. 519). The scientific novelty lies in the combination of a new 3-phase SAPF with a PV-battery system by FLC and a cascaded DC/DC converter. This allows effective voltage disturbance and harmonic compensation in various load situations without conventional transformers. Practical value. This research offers a robust solution for power quality problems in modern grids, reducing losses by ensuring stable, no-distortion power for sensitive industrial loads across varied operating conditions. References 46, tables 3, figures 19.
- 2 January 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 51-62
Open AccessAn integrated series active power filter combined with a PV-battery system based on a fuzzy logic controller to enhance power quality for various linear and non-linear loads
Introduction. Rapid capacity development and the incorporation of new loads are adding complexity to the distribution power system. As a result, the distribution system faces additional power quality issues, particularly with increasingly sensitive equipment and distributed generation. Problem. Modern power systems face escalating power quality degradation due to non-linear loads. Voltage disturbances (sags, swells) and harmonic distortions directly affect the sensitive equipment, causing significant economic losses. The goal of this work is to design, model, and evaluate series active power filters (SAPFs) integrated with energy management for an independent solar storage system, using a multi-stage DC-DC converter. The objective focuses on mitigating voltage harmonics and grid disturbances resulting from diverse loads (linear, non-linear, and combined) and integrating renewable energy (PV). Control is achieved through an intelligent fuzzy logic controller (FLC) and a PI controller to ensure a stable DC voltage and reduce the total harmonic distortion (THD) of the voltage to less than 5 %. Methodology. This study models and analyzes a unique SAPF configuration integrated with a PV-battery storage system utilizing MATLAB/Simulink. Outcomes of the proposed control, wherever the FLC regulates the DC-link voltage reference signals utilize the instantaneous reactive power theory. The suggested methodology entails simulation studies across four scenarios: an analysis of performance to keep voltage components and a comparison of the proposed SAPF performance with existing research on linear, non-linear, and combined loads. Results. Simulation results show the effectiveness of the control approach in mitigating the voltage THD level to less than 5 % under various operating conditions that included the main supply voltage and loads, which satisfies the international PQ standards (IEEE Std. 519). The scientific novelty lies in the combination of a new 3-phase SAPF with a PV-battery system by FLC and a cascaded DC/DC converter. This allows effective voltage disturbance and harmonic compensation in various load situations without conventional transformers. Practical value. This research offers a robust solution for power quality problems in modern grids, reducing losses by ensuring stable, no-distortion power for sensitive industrial loads across varied operating conditions. References 46, tables 3, figures 19.
- Open Access
- 31 October 2025
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 58 (10) , 2101-2111
Development of a Fuzzy Impedance Distance Protection Scheme to Enhance Fault Detection and Mitigate Power Swings in Electrical Power Grid
- 31 October 2025
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 58 (10) , 2101-2111
Open AccessDevelopment of a Fuzzy Impedance Distance Protection Scheme to Enhance Fault Detection and Mitigate Power Swings in Electrical Power Grid
- Open Access
- 31 July 2025
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 58 (7)
Design an Intelligent Multifunction Generator Protection System Based on the P-Q Capability Curve
- 31 July 2025
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 58 (7)
Open AccessDesign an Intelligent Multifunction Generator Protection System Based on the P-Q Capability Curve
- Open Access
- 30 April 2025
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 58 (4) , 727-735
A New Strategy for Detecting Unstable Power Swing Using Fault Impedance Trajectory and Its Impacts on Performance of the Impedance Distance Relay
- 30 April 2025
- Published by International Information and Engineering Technology Association in Journal Européen des Systèmes Automatisés
- Vol. 58 (4) , 727-735
Open AccessA New Strategy for Detecting Unstable Power Swing Using Fault Impedance Trajectory and Its Impacts on Performance of the Impedance Distance Relay