Ibrahim Ismael Alnaib
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ibrahim Ismael Alnaib has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Nasser B. Alsammak
College of Engineering, University of Mosul, Iraq
7 shared publications - Karam Khairullah Mohammed
Universiti Malaya
4 shared publications Karam Khairullah Mohammed
2 shared publications- Omar Sharaf Alyozbaky
University of Mosul
2 shared publications Saad Mekhilef
2 shared publicationsAli Abbawi
University of Mosul,Department of Electrical Engineering,Iraq
1 shared publication
Latest Publications
- Open Access
- 2 March 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 51-58
Intelligent unified power quality conditioner based photovoltaic to improve grid reliability and mitigate power quality issues
Problem. Electrical distribution networks are plagued by power quality problems, which have a negative impact on sensitive electrical loads. These problems include reactive current, low power factor on the load side, and voltage harmonics, voltage sags and voltage swells on the grid voltage side. To address these issues, a unified power quality conditioner (UPQC) that combines shunt and series compensators is suggested. The goal of the work is to implement a UPQC integrated with a photovoltaic (PV) system to mitigate power quality problems in the power system, and boosting the grid supply through power injection from the PV system. Methodology. One of the less complex and effective ways to improve the grid’s voltage quality is by using the unit vector template generation (UVTG) strategy as the composition technique (UPQC-P) through the UPQC series compensator. The synchronous reference frame (SRF) strategy through the UPQC shunt compensator to improve the current quality on the load side is used. To further optimize the SRF strategy, it is used the snake optimization (SO) to find the optimal values for the PI controller’s parameters. Results. The UPQC-PV is used to mitigation the power quality issues in the grid and loads by UVTG and SRF techniques in series and shunt compensators, respectively. Scientific novelty. The composition technique (UPQC-P) through a series compensator and uses the SO for tuning the PI controller in the shunt compensator. Practical value. This study reduces the total harmonic distortion (THD) in the load voltage to 0.57 %, while the THD in the grid voltage remains at 10 %. It restores the load voltage to its reference value of 230 V during voltage sags (down to 161 V) and swells (up to 300 V) in the grid. Additionally, it mitigates the low power factor on the load side (0.707 lagging) to achieve a unity power factor in grid current, balances the unbalanced load current to a balanced grid current, and enhances grid stability by injecting power from the PV system into the grid. References 33, table 3, figures 7.
- 2 March 2026
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 51-58
Open AccessIntelligent unified power quality conditioner based photovoltaic to improve grid reliability and mitigate power quality issues
Problem. Electrical distribution networks are plagued by power quality problems, which have a negative impact on sensitive electrical loads. These problems include reactive current, low power factor on the load side, and voltage harmonics, voltage sags and voltage swells on the grid voltage side. To address these issues, a unified power quality conditioner (UPQC) that combines shunt and series compensators is suggested. The goal of the work is to implement a UPQC integrated with a photovoltaic (PV) system to mitigate power quality problems in the power system, and boosting the grid supply through power injection from the PV system. Methodology. One of the less complex and effective ways to improve the grid’s voltage quality is by using the unit vector template generation (UVTG) strategy as the composition technique (UPQC-P) through the UPQC series compensator. The synchronous reference frame (SRF) strategy through the UPQC shunt compensator to improve the current quality on the load side is used. To further optimize the SRF strategy, it is used the snake optimization (SO) to find the optimal values for the PI controller’s parameters. Results. The UPQC-PV is used to mitigation the power quality issues in the grid and loads by UVTG and SRF techniques in series and shunt compensators, respectively. Scientific novelty. The composition technique (UPQC-P) through a series compensator and uses the SO for tuning the PI controller in the shunt compensator. Practical value. This study reduces the total harmonic distortion (THD) in the load voltage to 0.57 %, while the THD in the grid voltage remains at 10 %. It restores the load voltage to its reference value of 230 V during voltage sags (down to 161 V) and swells (up to 300 V) in the grid. Additionally, it mitigates the low power factor on the load side (0.707 lagging) to achieve a unity power factor in grid current, balances the unbalanced load current to a balanced grid current, and enhances grid stability by injecting power from the PV system into the grid. References 33, table 3, figures 7.
- Open Access
- 2 March 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 19-23
Brushless DC motor drive with optimal fractional-order sliding-mode control based on a genetic algorithm
Introduction. Brushless DC (BLDC) motor is a type of permanent magnet synchronous motor that operates without brushes employed in many applications owing to its efficiency and control in electric cars. One of the main reasons BLDC motors are better than brushed DC motors is that they employ an electronic commutation circuit instead of a mechanical one. The fractional order sliding mode controller (FOSMC) was used, which is characterized by high durability and is not affected by the disturbances that the motor is exposed to during operation, as well as overcoming the chattering phenomenon present in the conventional sliding mode controller (CSMC). The novelty of the proposed work consists of to use FOSMC by genetic algorithm (GA) to mitigate the chattering phenomena in sliding mode control (SMC) for optimal response for speed control and regeneration braking control in BLDC motor by using single stage by voltage source inverter and decrease energy use during motor starting. Purpose. Improvement FOSMC techniques for the regulation of BLDC motor’s driving control system. Methods. Employing the GA to optimize the parameters of FOSMC to mitigate the chattering phenomenon in SMC to regulate BLDC motor’s driving control system. Results. A comparison was made between two types of sliding controllers to obtain the best performance of the control system in speed control operations and motor braking operations, the FOSMC, through parameter optimization via the GA, surpasses the CSMC in achieving optimal performance in driving the BLDC motor. Practical value. FOSMC exhibits superiority over the CSMC, as indicated by the reduced integral time absolute error in motor speed tracking and regenerative brake control, with values of (0.028, 0.046, and 0.075) for the FOSMC, in contrast to (2.72, 1.56, and 0.17) for the CSMC, the overshoot for FOSMC is (0, 0, and 11.4), but for CSMC it is (60.4, 43.7, and 11.2). During braking mode for FOSMC, the power recovery from the motor to the battery was (1.96, 9, and 17.76), but in CSMC, it was (0.99, 4.49, and 11.98). Moreover, the braking length was expedited, and the battery’s initial power consumption diminished at the outset. References 32, tables 5, figures 6.
- 2 March 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 2,p. 19-23
Open AccessBrushless DC motor drive with optimal fractional-order sliding-mode control based on a genetic algorithm
Introduction. Brushless DC (BLDC) motor is a type of permanent magnet synchronous motor that operates without brushes employed in many applications owing to its efficiency and control in electric cars. One of the main reasons BLDC motors are better than brushed DC motors is that they employ an electronic commutation circuit instead of a mechanical one. The fractional order sliding mode controller (FOSMC) was used, which is characterized by high durability and is not affected by the disturbances that the motor is exposed to during operation, as well as overcoming the chattering phenomenon present in the conventional sliding mode controller (CSMC). The novelty of the proposed work consists of to use FOSMC by genetic algorithm (GA) to mitigate the chattering phenomena in sliding mode control (SMC) for optimal response for speed control and regeneration braking control in BLDC motor by using single stage by voltage source inverter and decrease energy use during motor starting. Purpose. Improvement FOSMC techniques for the regulation of BLDC motor’s driving control system. Methods. Employing the GA to optimize the parameters of FOSMC to mitigate the chattering phenomenon in SMC to regulate BLDC motor’s driving control system. Results. A comparison was made between two types of sliding controllers to obtain the best performance of the control system in speed control operations and motor braking operations, the FOSMC, through parameter optimization via the GA, surpasses the CSMC in achieving optimal performance in driving the BLDC motor. Practical value. FOSMC exhibits superiority over the CSMC, as indicated by the reduced integral time absolute error in motor speed tracking and regenerative brake control, with values of (0.028, 0.046, and 0.075) for the FOSMC, in contrast to (2.72, 1.56, and 0.17) for the CSMC, the overshoot for FOSMC is (0, 0, and 11.4), but for CSMC it is (60.4, 43.7, and 11.2). During braking mode for FOSMC, the power recovery from the motor to the battery was (1.96, 9, and 17.76), but in CSMC, it was (0.99, 4.49, and 11.98). Moreover, the braking length was expedited, and the battery’s initial power consumption diminished at the outset. References 32, tables 5, figures 6.
- 17 January 2025
- Published by Springer Nature
- p. 35-48
Reduce Multiple Power Quality Issues with UPQC by Using UVTG and PQ Current Control Techniques Based on Snake Optimization
- 17 January 2025
- Published by Springer Nature
- p. 35-48
Reduce Multiple Power Quality Issues with UPQC by Using UVTG and PQ Current Control Techniques Based on Snake Optimization
- 17 January 2025
- Published by Springer Nature
- p. 49-62
Utilize UPQC to Reduce Power Quality Issues by SRF Control Strategies Based on Snake Optimization
- 17 January 2025
- Published by Springer Nature
- p. 49-62
Utilize UPQC to Reduce Power Quality Issues by SRF Control Strategies Based on Snake Optimization
- Open Access
- 2 January 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 3-7
Optimization of fractional PI controller parameters for enhanced induction motor speed control via indirect field-oriented control
Introduction. Induction Motors (IM) possess advantages such as stability, reliability, and ease of control, making them suitable for many purposes; the literature elucidates control methodologies for IM drives, primarily focusing on scalar and vector control techniques; the conventional method utilized in manufacturing is scalar control, which unfortunately demonstrates optimal performance solely in steady-state conditions. The absence of significant instantaneous torque control restricts flux and dissociated torque, resulting in subpar dynamic responsiveness. Indirect Field Oriented Control (IFOC) for IM drives has proven beneficial for various industrial applications, particularly electric vehicle propulsion. The primary advantages of this approach include the decoupling of torque and flux characteristics and its straightforward implementation. The novelty of the work consists of a proposal for a driving cycle model for testing the control system of electric vehicles in Mosul City (Iraq), and using a Complex Fractional Order Proportional Integral (CFOPI) controller to control IMs via IFOC strategies, the Artificial Bee Colony (ABC) algorithm was applied, which is considered to be highly efficient in finding the values of controllers. Purpose. Improvement IFOC techniques for the regulation of IM speed. Methods. Using the ABC algorithm in tuning the two unique CFOPI controller, and a Real Fractional Order Proportional Integral (RFOPI) controller, to regulate the speed of a three-phase IM via IFOC techniques. Results. The CFOPI controller outperforms the RFOPI controller in obtaining the best performance in controlling the IM. Practical value. The CFOPI controller demonstrates superiority over the RFOPI controller, as evidenced by the lower integral time absolute error in motor speed tracking during the driving cycle 2.1004 for the CFOPI controller compared to 2.1538 for the RFOPI controller. References 27, tables 5, figures 4.
- 2 January 2025
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 1,p. 3-7
Open AccessOptimization of fractional PI controller parameters for enhanced induction motor speed control via indirect field-oriented control
Introduction. Induction Motors (IM) possess advantages such as stability, reliability, and ease of control, making them suitable for many purposes; the literature elucidates control methodologies for IM drives, primarily focusing on scalar and vector control techniques; the conventional method utilized in manufacturing is scalar control, which unfortunately demonstrates optimal performance solely in steady-state conditions. The absence of significant instantaneous torque control restricts flux and dissociated torque, resulting in subpar dynamic responsiveness. Indirect Field Oriented Control (IFOC) for IM drives has proven beneficial for various industrial applications, particularly electric vehicle propulsion. The primary advantages of this approach include the decoupling of torque and flux characteristics and its straightforward implementation. The novelty of the work consists of a proposal for a driving cycle model for testing the control system of electric vehicles in Mosul City (Iraq), and using a Complex Fractional Order Proportional Integral (CFOPI) controller to control IMs via IFOC strategies, the Artificial Bee Colony (ABC) algorithm was applied, which is considered to be highly efficient in finding the values of controllers. Purpose. Improvement IFOC techniques for the regulation of IM speed. Methods. Using the ABC algorithm in tuning the two unique CFOPI controller, and a Real Fractional Order Proportional Integral (RFOPI) controller, to regulate the speed of a three-phase IM via IFOC techniques. Results. The CFOPI controller outperforms the RFOPI controller in obtaining the best performance in controlling the IM. Practical value. The CFOPI controller demonstrates superiority over the RFOPI controller, as evidenced by the lower integral time absolute error in motor speed tracking during the driving cycle 2.1004 for the CFOPI controller compared to 2.1538 for the RFOPI controller. References 27, tables 5, figures 4.
- Open Access
- 1 April 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (2) , 597-607
Faults detection, location, and classification of the elements in the power system using intelligent algorithm
This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.
- 1 April 2023
- Published by Institute of Advanced Engineering and Science in Bulletin of Electrical Engineering and Informatics
- Vol. 12 (2) , 597-607
Open AccessFaults detection, location, and classification of the elements in the power system using intelligent algorithm
This study proposes an intelligent protection relay design that uses artificial neural networks to secure electrical parts in power infrastructure from different faults. Electrical transformer and transmission lines are protected using intelligent differential and distance relay, respectively. Faults are categorized, and their locations are pinpointed using three-phase current values and zero-current characteristics to differentiate between non-earth and ground faults. The optimal aspects of the artificial neural network were chosen for optimal results with the least possible error. Levenberg-Marquardt was established as the ideal training technique for the suggested system comprising the differential relay. Levenberg-Marquardt was the optimal training technique for the proposed framework consisting of the differential relay. Fault detection and categorization were performed using 20 and 50 hidden layers, and the corresponding error rates were 9.9873e-3 and 1.1953e-29. In the context of fault detection by the distance relay, the hidden layer neuron counts were 400, 250, and 300 for fault detection, categorization, and location; training error rates were 7.8761e-2, 1.2063e-6, and 1.1616e-26, respectively.
- 7 July 2022
- Published by Springer Nature
- p. 545-555
Protection Relay Performance Comparison for Faults Detection and Classification Based on ANN and ANFIS
- 7 July 2022
- Published by Springer Nature
- p. 545-555
Protection Relay Performance Comparison for Faults Detection and Classification Based on ANN and ANFIS