LWLinhong Wang

Linhong Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Linhong Wang has a total of 78 co-authors. Here are the top co-authors by number of shared publications:

  • Fan Yang

    Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People’s Hospital, Affiliated People’s Hospital, Hangzhou Medical College, Hangzhou, China

    19 shared publications
  • Jianping Chen

    Center for Plastic & Reconstructive Surgery, Department of Stomatology Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College Hangzhou Zhejiang China

    8 shared publications
  • Yude Ding

    Department of Stomatology, Center for Plastic and Reconstructive Surgery, Zhejiang Provincial People’s Hospital (Affiliated People’s Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, China

    5 shared publications
  • Yude Ding

    Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China

    5 shared publications
  • Ruijue Cao

    Department of Stomatology Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College Hangzhou Zhejiang China

    4 shared publications
  • Wentao Zhang

    Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou 310014, PR China

    4 shared publications

Latest Publications

  • Association Between Bone Microstructure Derived From CBCT and Marginal Bone Loss in a Platform‐Switched Implant System: A 1‐to‐8‐Year Retrospective Study

    by Wenxi Dong, Xinrui Lang, Jie Xia, Ying Yang, Fan Yang, Linhong Wang

    Objective: To evaluate the relationship between cone‐beam computed tomography (CBCT)‐derived bone microstructure parameters and marginal bone loss (MBL) around platform‐switched subcrestal implants over 1–8 years. Methods: A retrospective analysis assessed 142 platform‐switched implants in 100 patients. CBCT‐based bone microstructure parameters—bone volume (BV), tissue volume (TV), bone volume fraction (BV/TV), bone surface (BS), bone surface fraction (BS/BV), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp)—were measured in peri‐implant and cervical regions. Radiographic MBL was evaluated at baseline (T0: prosthetic insertion) and follow‐ups (T1: 1–3 years post‐loading, T2: 3–8 years post‐loading). Associations between bone microstructure parameters and MBL were analyzed using Generalized estimating equations (GEE). Results: GEE analysis of 142 implants from 100 patients, adjusting for covariates, linked baseline bone microstructure to MBL at T0, T1 and T2. No significant associations were found at T0 or T1 ( p > 0.05). At T2, cervical bone microstructure parameters were not significant. However, peri‐implant parameters were predictive: BV/TV was protective (B = −1.028, p = 0.0125), while BS/BV (B = 0.008, p = 0.0384) and Tb.Sp (B = 1.214, p = 0.0270) were significant risk factors for long‐term MBL. Conclusion: Peri‐implant BV/TV, BS/BV and Tb.Sp might be critical predictors of long‐term MBL progression in platform‐switched subcrestal implants, while cortical bone thickness has limited impact. CBCT‐based bone microstructure analysis could aid MBL risk prediction and clinical management. Trial Registration: This study has been registered in the Chinese Clinical Trial Registry, with the registration number ChiCTR2500098567


  • Open Access

    A deep learning based automated maxillary sinus segmentation and bone grafts analysis in CBCT images

    by Fan Yang, Xing Wu, Yukang Zhang, Xinrui Lang, Ying Yang, Leizi Ma, Yude Ding, Linhong Wang

    Precise evaluation of bone gain after maxillary sinus augmentation is critical for optimizing implant therapy yet manual measurements remain time consuming. This study validated a fully automated deep learning system named SA-ai to quantify bone augmentation. A paired CBCT dataset from 85 patients was used to train and test the system which integrates a 2D U-Net for sinus contour and a 3D V-Net for maxilla segmentation. The system achieved a Dice coefficient of 93.2% and registration RMSE of 1.046 mm. Clinical validation against manual measurements showed excellent agreement for bone volume (ICC = 0.993) and other parameters. Bias analysis confirmed measurement stability while workflow efficiency improved over 20-fold compared to manual methods. This registration subtraction paradigm delivers an automated and objective solution for longitudinal monitoring of bone graft volume including one-stage implant cases potentially standardizing clinical evaluation of post augmentation bone dynamics.


  • Open Access

    Recent advances in metal-organic frameworks for therapeutic applications in periodontitis

    by Jiaqi Chen, Yang Bai, Yude Ding, Linhong Wang, Wentao Zhang, Fan Yang

    Periodontitis is a highly prevalent chronic inflammatory disease that leads to the destruction of periodontal tissues and has systemic health implications. Current treatments, such as mechanical debridement and antibiotics, are often inadequate due to poor biofilm penetration, drug resistance, and limited regenerative capacity. Metal-organic frameworks (MOFs) have recently emerged as a transformative platform to address these limitations and surpass traditional nanomaterials (e.g., liposomes, dendrimers). Their tunable porosity, multifunctional composition, and responsive degradation enable antibacterial, anti-inflammatory, and pro-regenerative actions. This review highlights the mechanisms by which MOFs combat periodontal pathogens, resolve inflammation, and promote tissue regeneration, outperforming conventional materials. We also discuss combinatorial strategies, such as photodynamic and immunomodulatory therapies, that enhance treatment efficacy. Despite promising preclinical results, challenges in biocompatibility, biodegradation, and clinical translation remain. Future efforts should focus on developing intelligent, multifunctional MOF platforms capable of microenvironment-responsive therapy to achieve complete periodontal restoration.


  • Influence of Bone Condition and Implant Design on Accuracy of Semi‐Autonomous Robotic Dental Implant Surgery In Vitro

    by Qingwei Tang, Linhong Wang, Yude Ding, Yuchen Zheng, Xulan Yang, Jie Xia, Fan Yang

    Objectives: This study aimed to evaluate the effects of bone density, cortical bone thickness, and implant design on the accuracy of implant placement using a novel semi‐autonomous robotic‐assisted surgery system (sa‐RASS). Materials and Methods: A total of 160 implants were placed in artificial bone models simulating four bone densities (D1, D2, D3, D4) and three cortical bone thicknesses (0.5, 1, 1.5 mm) using sa‐RASS. Two implant designs (self‐tapping and non‐self‐tapping) were evaluated under standardized cortical bone thickness conditions. The postoperative CBCT data and preoperative surgical plan were superimposed to calculate the deviations of the implant. Deviations were quantified for platform/apex positions (global, horizontal, vertical) and implant angulation. Results: The sa‐RASS achieved mean deviations of 0.58 ± 0.19 mm at platform, 0.60 ± 0.24 mm at apex, and 1.46° ± 0.78° for angulation. Bone density significantly influenced accuracy ( p < 0.05), with maximum deviations in medium‐density (D2/D3) models and minimal errors in high‐density (D1) and low‐density (D4) groups. Cortical thickness exhibited a moderate positive correlation with linear deviations (platform: r = 0.598; apex: r = 0.593; both p < 0.001). Self‐tapping implants demonstrated superior precision compared to non‐self‐tapping designs ( p < 0.05), with reduced deviations at both platform (0.48 ± 0.16 mm) and apex (0.49 ± 0.16 mm). Conclusions: This in vitro study demonstrated that bone condition and implant design significantly influence the accuracy of sa‐RASS. Understanding these factors can help optimize robotic‐assisted implant placement and improve clinical outcomes. Clinical Significance: Bone condition and implant design significantly affect the accuracy of robotic‐assisted implant placement. Preoperative assessment and proper implant selection can enhance precision and improve clinical outcomes.


  • Top Cited Papers
    Open Access

    A multi-dimensional performance evaluation of large language models in dental implantology: comparison of ChatGPT, DeepSeek, Grok, Gemini and Qwen across diverse clinical scenarios

    by Xing Wu, Guofei Cai, Bin Guo, Leizi Ma, Siqi Shao, Jun Yu, Yuchen Zheng, Linhong Wang, Fan Yang

    Large language models (LLMs) show promise in medicine, but their effectiveness in specialized fields like implant dentistry remains unclear. This study focuses on five recently released LLMs aiming to systematically evaluate their capabilities in clinical implantology scenarios and to investigate their respective strengths and weaknesses thoroughly to guide precise application. A comprehensive multi-dimensional evaluation was conducted using a test set of 40 professional questions (across 8 themes) and 5 complex cases. To ensure response uniformity, all queries were submitted to five LLMs (ChatGPT-o3-mini, DeepSeek-R1, Grok-3, Gemini-2.0-flash-Thinking, and Qwen2.5-max) using a pre-defined prompt. With standardized parameters to ensure a fair comparison, a single response was generated for each query without re-generation. The responses of the five LLMs were scored by three experienced senior experts from five dimensions in two rounds of double-blind. Inter-rater reliability was tested, followed by statistical analyses including Spearman’sρtest, Friedman test, mixed effect model, and principal component analysis. High inter-rater reliability was confirmed among the three experts (ICC for average measures ranged from 0.685 to 0.814, all P < 0.001). Gemini-2.0-flash-thinking achieved the highest overall performance, with a mean score of 21.9 in professional question answering and 22.2 in case analysis. This was significantly higher than ChatGPT-o3-mini (mean score 19.2) in question responses and Qwen2.5-max (mean score 16.9) in case evaluations. Mixed-effects models showed Gemini-2.0-flash-thinking superiority over ChatGPT-o3-mini, while Qwen2.5-max exhibited a decline in performance. DeepSeek-R1 and Qwen2.5-max also showed positive interaction effects in specific themes (such as Theme3). The PCA results further indicate that Gemini-2.0-flash-thinking demonstrated the best comprehensive ability in both types of tasks, and reveal the existing differences in the performance of various LLMs. This study reveals diverse LLMs differentiated capabilities in dental implantology, recommending context-specific model selection to different clinical scenario, as Gemini-2.0-flash-Thinking demonstrates optimal performance, notably for high-level clinical support. The study protocol and the use of clinical case data have been approved by the Medical Ethics Committee of Zhejiang Provincial People’s Hospital (Approval No. QT2025050) on March 4th, 2025. Clinical trial number is not applicable.


  • Open Access

    Accuracy of a Novel Robot‐Assisted System and Dynamic Navigation System for Dental Implant Placement: A Clinical Retrospective Study

    by Jianping Chen, Yude Ding, Ruijue Cao, Yuchen Zheng, Liheng Shen, Linhong Wang, Fan Yang

    Aim: This clinical retrospective study aimed to compare the deviations in single‐tooth implant placement using novel semi‐autonomous robotic‐assisted surgery system (sa‐RASS) and dynamic navigation system (DNS) methods. Materials and Methods: A retrospective analysis of medical records from January to December 2023 was conducted to compare the implantation accuracy of the sa‐RASS and DNS in partially edentulous patients using cone‐beam computed tomography. Platform, apex, and angular deviations were measured and analyzed. The Kolmogorov–Smirnov test was used to check the data distribution, along with t ‐tests or Mann–Whitney U‐tests, where appropriate. Results: Fifty‐seven patients (57 implants) were analyzed: 29 (29 implants) in the sa‐RASS group and 28 (28 implants) in the DNS group. The comparison of platform, apex, and angular deviation between the sa‐RASS group and DNS group were 0.91 ± 0.46 mm vs. 1.26 ± 0.51 mm ( p < 0.001), 1.06 ± 0.60 mm vs. 1.51 ± 0.56 mm ( p < 0.001), and 3.07° ± 1.66° vs. 3.71° ± 1.64° ( p > 0.05), respectively. In addition, there was no significant difference in the accuracy of different implant regions (premolar, molar, maxilla, and mandible) or implant length ( p > 0.05). Conclusions: In the present study, sa‐RASS implant placement showed better positional accuracy than DNS implant placement in platform and apex deviation, although these improvements in accuracy may have limited clinical relevance, suggesting that the sa‐RASS might be advantageous in dental implant surgery. Trial Registration: ClinicalTrials.gov identifier: ChiCTR2400085089


  • Open Access

    Effect of Bone Microstructure Derived From CBCT on the Accuracy of Robot‐Assisted Implant Surgery: A Retrospective Study

    by Wenxi Dong, Linhong Wang, Yuanna Zheng, Xulan Yang, Liheng Shen, Fan Yang, Yuchen Zheng

    Objective: The aim of this study was to investigate the influence of bone microstructure on the accuracy of robot‐assisted dental implant surgery. Materials and Methods: This retrospective study analyzed 52 patients who received robot‐assisted implant surgery between January 2023 and October 2023. Cone beam computed tomography (CBCT) scans were used to evaluate bone microstructural parameters, including the bone volume (BV), tissue volume (TV), bone volume fraction (BV/TV), bone surface (BS), bone surface fraction (BS/BV), trabecular thickness (Tb.Th), and trabecular separation (Tb.Sp). Preoperative and postoperative CBCT data were used to evaluate implant accuracy, and the relationship between bone microstructure parameters and implant deviation including platform deviation, apex deviation, and angular deviation was statistically analyzed. Results: In robot‐assisted implant surgery, BS/BV was a potential facilitator of several implant deviations, while BV/TV and Tb.Th were potential inhibitors of apex global deviation and angular deviation, respectively. Implant deviations were divided into two groups of large and small deviations by median, and the receiver operating characteristic (ROC) curve analysis showed that Tb.Th had the largest area under the ROC for predicting large apex global deviation, 0.711 ( p < 0.001), with an optimal cutoff value > 0.179, a sensitivity and specificity of 70.37% and 76.92%. Conclusion: The study concluded that bone microstructure might affect the accuracy of dental implant placement in robotic surgeries. Incorporating bone quality assessments into preoperative planning may enhance the precision and outcomes of implant procedures, highlighting the potential for further refinement in robotic‐assisted dental surgery techniques. Trial Registration: ClinicalTrials.gov identifier: ChiCTR2400085813


  • Open Access

    Comparative analysis of dental implant placement accuracy: Semi‐active robotic versus free‐hand techniques: A randomized controlled clinical trial

    by Fan Yang, Jianping Chen, Ruijue Cao, Qingwei Tang, Haiyan Liu, Yuchen Zheng, BeiLei Liu, Min Huang, Zhenshi Wang, Yude Ding, et al.

    Background: Robot‐assisted implant surgery has emerged as a novel digital technology, and the accuracy need further assessment.Purpose: This study aimed to compare the accuracy of single dental implant placement between a novel semi‐active robot‐assisted implant surgery (RAIS) method and the conventional free‐hand implant surgery (FHIS) method through a multicenter, randomized controlled clinical trial.Materials and Methods: Patients requiring single dental implant placement were recruited and randomized into RAIS and FHIS group. Deviations at the platform, apex, and angle between the planned and final implant positions were assessed in both groups. Additionally, the evaluation of instrument and surgical complications was examined.Results: A total of 140 patients (median age: 35.35 ± 12.55 years; 43 males, 97 females) with 140 implants from four different research centers were included, with 70 patients (70 implants) in the RAIS group and 70 patients (70 implants) in the FHIS group. In the RAIS and FHIS groups, the median platform deviations were 0.76 ± 0.36 mm and 1.48 ± 0.93 mm, respectively (p < 0.001); median apex deviations were 0.85 ± 0.48 mm and 2.14 ± 1.25 mm, respectively (p < 0.001); and median angular deviations were 2.05 ± 1.33° and 7.36 ± 4.67°, respectively (p < 0.001). Similar significant difference also presented between RAIS and FHIS group in platform vertical/horizontal deviation, apex vertical/horizontal deviation. Additionally, implants with self‐tapping characteristics exhibited significantly larger deviations compared with those without self‐tapping characteristics in the RAIS group. Both RAIS and FHIS methods demonstrated comparable morbidity and safety pre‐ and post‐operation.Conclusions: The results indicated that the RAIS method demonstrated superior accuracy in single dental implant placement compared with the FHIS method. Specifically, RAIS exhibited significantly smaller deviations in platform, apex, and angular positions, as well as platform and apex vertical/horizontal deviations.This clinical trial was not registered prior to participant recruitment and randomization. https://www.chictr.org.cn/showproj.html?proj=195045.


  • Tunable and fast-cured hyaluronic acid hydrogel inspired on catechol architecture for enhanced adhesion property

    by Fan Yang, Yunlu Chen, Wentao Zhang, Shaochun Gu, Zhenjie Liu, Maohu Chen, Leidan Chen, Feng Chen, Huicong Zhang, Yude Ding, et al.


  • DSIS-DPR:Structured Instance Segmentation and Diffusion Prior Refinement for Dental Anatomy Learning

    by Xianyun Wang, Linhong Wang, Zhenchen Yang, Jiacong Zhou, Yuchen Zheng, Feng Chen, Richang Hong, Jun Yu, Fan Yang

    Instance segmentation in medical imaging plays a crucial role in clinical diagnostic tasks, and have shown promising performance in practical applications. In this paper, we discuss a more fine-grained instance segmentation task: dental structured instance segmentation based on panoramic radiographs. However, direct segmentation of tooth structures encounters inherent challenges. Traditional instance segmentation networks often fall short in capturing intricate internal features, and exacerbated by the frequent blurring found in medical imaging, which can result in the deficiency of anatomical details. To deal with these problems, we propose a novel framework called DSISDPR, which combines a dental structured instance segmentation (DSIS) network with an enhanced diffusion prior refinement (DPR) method. Specifically, our innovatively designed structureaware network leverages fine-grained feature fusion, acquiring a richer representation of internal anatomical structures. With the integration of adversarial learning, the model is primed to deliver holistic and subtle predictions of tooth structures. Furthermore, taking inspiration from dentists’ inherent ability to utilize prior knowledge, such as understanding dental structures to label invisible anatomical structures, we propose a diffusion inpainting to refine the results of DSIS without additional annotations. Equipped with built-in structure learning, DPR is capable of modifying anomalies within each predicted segmentation, resulting in a more robust and complete structured segmentation result. Meanwhile, we ensure rigorous oversight over the reconstruction of areas affected by abnormalities, ensuring that any introduced adjustments minimally disrupt the wellpredicted structured segmentation results. Extensive experiments have demonstrated that our DSIS-DPR outperforms all existing classical instance segmentation networks. The collected dataset is available: https://github.com/Zzz512/TSD .