YDYude Ding

Yude Ding

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yude Ding has a total of 37 co-authors. Here are the top co-authors by number of shared publications:

  • Fan Yang

    Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People’s Hospital, Affiliated People’s Hospital, Hangzhou Medical College, Hangzhou, China

    7 shared publications
  • Linhong Wang

    Center for Plastic and Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People’s Hospital, Affiliated People’s Hospital, Hangzhou Medical College, Hangzhou, China

    5 shared publications
  • Fan Yang

    Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China

    4 shared publications
  • Jianping Chen

    Attending, Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital), Hangzhou Medical College, Hangzhou, Zhejiang, PR China

    4 shared publications
  • Linhong Wang

    Center for Plastic & Reconstructive Surgery, Department of Stomatology, Zhejiang Provincial People's Hospital, Affiliated People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China

    4 shared publications
  • Runzhi Chen

    Affiliated Hangzhou First People's Hospital, Westlake University School of Medicine, Hangzhou, Zhejiang, China

    4 shared publications

Latest Publications

  • Open Access

    Tooth Transplantation With Sticky Bone for Vertical Bone Defects: A 4‐Year Follow‐Up Case Report

    by Jie Xia, Yuxin Zheng, Runzhi Chen, Fan Yang, Yude Ding

    Background: Severe buccal vertical bone defects accompanied by combined periodontal–endodontic lesions are challenging to manage, and evidence regarding the long‐term outcomes of digitally assisted autotransplantation combined with sticky bone grafting remains limited. We aimed to report a case of digitally assisted tooth autotransplantation combined with autologous alveolar bone and sticky bone grafts for the reconstruction of a severe buccal vertical defect. Case Description: A 23‐year‐old female patient underwent autotransplantation of the right maxillary third molar (#1) to replace the left mandibular first molar (#19) affected by a severe buccal vertical bone defect in July 2020. The autotransplantation procedure involving the donor tooth and the attached autologous alveolar bone from Tooth #1 was simulated using surgical planning software to determine the optimal rotation and angulation of the donor tooth. Buccal bone augmentation for the vertical defect associated with severe furcation involvement was achieved by transplanting the distal alveolar bone of Tooth #1 in combination with sticky bone grafts. The tooth was stabilized with resin fiber tape for 4 weeks. Conclusion: At the 4‐year follow‐up, no clinical or radiographic abnormalities or signs of infection or inflammation were observed. This approach may represent a feasible option for selected cases with severe buccal vertical bone defects.

  • Open Access

    A deep learning based automated maxillary sinus segmentation and bone grafts analysis in CBCT images

    by Fan Yang, Xing Wu, Yukang Zhang, Xinrui Lang, Ying Yang, Leizi Ma, Yude Ding, Linhong Wang

    Precise evaluation of bone gain after maxillary sinus augmentation is critical for optimizing implant therapy yet manual measurements remain time consuming. This study validated a fully automated deep learning system named SA-ai to quantify bone augmentation. A paired CBCT dataset from 85 patients was used to train and test the system which integrates a 2D U-Net for sinus contour and a 3D V-Net for maxilla segmentation. The system achieved a Dice coefficient of 93.2% and registration RMSE of 1.046 mm. Clinical validation against manual measurements showed excellent agreement for bone volume (ICC = 0.993) and other parameters. Bias analysis confirmed measurement stability while workflow efficiency improved over 20-fold compared to manual methods. This registration subtraction paradigm delivers an automated and objective solution for longitudinal monitoring of bone graft volume including one-stage implant cases potentially standardizing clinical evaluation of post augmentation bone dynamics.


  • Open Access

    Evaluation of the accuracy of semi-autonomous robotic system versus dynamic navigation in completely edentulous implant surgery: an in vitro study

    by Jie Xia, Qingwei Tang, Haiyan Liu, Yuchen Zheng, Linhong Wang, Xulan Yang, Jianying Feng, Fan Yang, Yude Ding

    This study compared the accuracy (defined by trueness and precision) of implant placement between a semi-autonomous robotic system (SARS) and a dynamic navigation system (DNS) in completely edentulous models, evaluating the influence of alveolar bone morphology and implant orientation. Thirty-two completely edentulous models were divided by anterior ridge morphology (well-rounded or narrow). Following the All-on-4 protocol, anterior implants were placed vertically, and posterior implants were inserted vertically or at a distal tilt using either SARS or DNS. Planning was conducted virtually, and deviations were assessed postoperatively via CBCT. Mann-Whitney U test and linear mixed model were used for statistical analysis. All 128 implants were placed successfully. Platform global deviations were 0.69 ± 0.29 mm (SARS) and 0.72 ± 0.41 mm (DNS); apical global deviations were 0.74 ± 0.27 mm (SARS) and 0.70 ± 0.40 mm (DNS). SARS achieved significantly lower angular deviation (superior trueness) overall (P < .05), particularly in distally tilted implants (P < .001). On well-rounded ridges, SARS showed smaller global and lateral platform deviations (P < .05). On narrow ridges, SARS had larger platform and apical depth deviations (P < .01) but maintained better angular control (P < .01). Precision analysis revealed that SARS achieved superior platform precision under complex conditions (distally tilted implants and narrow ridges), while on well-rounded ridges, it showed higher apical precision and more consistent angular control. Both SARS and DNS demonstrated excellent accuracy in completely edentulous models. Furthermore, the SARS showed superior angular trueness and platform precision in distally tilted implant placement and complex bone morphology.


  • Injectable light-cured and bioabsorbable silk fibroin/hyaluronic acid (SF-HA) hydrogel tissue barrier for accelerating guided bone regeneration

    by Yuxin Zheng, Wentao Zhang, Runzhi Chen, Linhong Wang, Danni Wu, Zhuoheng Xia, Feng Chen, Fan Yang, Yude Ding


  • Influence of Bone Condition and Implant Design on Accuracy of Semi‐Autonomous Robotic Dental Implant Surgery In Vitro

    by Qingwei Tang, Linhong Wang, Yude Ding, Yuchen Zheng, Xulan Yang, Jie Xia, Fan Yang

    Objectives: This study aimed to evaluate the effects of bone density, cortical bone thickness, and implant design on the accuracy of implant placement using a novel semi‐autonomous robotic‐assisted surgery system (sa‐RASS). Materials and Methods: A total of 160 implants were placed in artificial bone models simulating four bone densities (D1, D2, D3, D4) and three cortical bone thicknesses (0.5, 1, 1.5 mm) using sa‐RASS. Two implant designs (self‐tapping and non‐self‐tapping) were evaluated under standardized cortical bone thickness conditions. The postoperative CBCT data and preoperative surgical plan were superimposed to calculate the deviations of the implant. Deviations were quantified for platform/apex positions (global, horizontal, vertical) and implant angulation. Results: The sa‐RASS achieved mean deviations of 0.58 ± 0.19 mm at platform, 0.60 ± 0.24 mm at apex, and 1.46° ± 0.78° for angulation. Bone density significantly influenced accuracy ( p < 0.05), with maximum deviations in medium‐density (D2/D3) models and minimal errors in high‐density (D1) and low‐density (D4) groups. Cortical thickness exhibited a moderate positive correlation with linear deviations (platform: r = 0.598; apex: r = 0.593; both p < 0.001). Self‐tapping implants demonstrated superior precision compared to non‐self‐tapping designs ( p < 0.05), with reduced deviations at both platform (0.48 ± 0.16 mm) and apex (0.49 ± 0.16 mm). Conclusions: This in vitro study demonstrated that bone condition and implant design significantly influence the accuracy of sa‐RASS. Understanding these factors can help optimize robotic‐assisted implant placement and improve clinical outcomes. Clinical Significance: Bone condition and implant design significantly affect the accuracy of robotic‐assisted implant placement. Preoperative assessment and proper implant selection can enhance precision and improve clinical outcomes.


  • Open Access

    Advances of natural hydrogel-based vascularization strategies for soft tissue repair

    by Zhuoheng Xia, Bin Guo, Danni Wu, Fan Yang, Yude Ding

    Regeneration of soft tissues, especially those requiring complex vascularization, is a major challenge in the field of tissue engineering. The current types of tissue engineering scaffolds include sponges, electric spinning silk, hydrogels, and 3D printed biomaterials. Among them, hydrogels have the unique property of mimicking extracellular matrix (ECM), which can provide a relatively stable microenvironment for cellular activities and facilitate cell adhesion, proliferation, and differentiation; thus, have become a promising scaffold. In this paper, we present a review of the commonly used types of natural hydrogels and their applications as scaffolds in tissue vascularization. First, we enumerate the importance and advantages of several types of commonly used hydrogels of natural origin in terms of fabricating vascularized tissues or organs. Second, we discuss two different formation modalities of blood vessels, as well as natural hydrogel-based vascularization strategies, including carrying growth factors, stem cell delivery, special scaffold structures and pharmaceutical-enhanced strategy. In addition, we describe the crosslinking strategies of hydrogels as scaffolds for regeneration of vascularized soft tissues, as well as the factors affecting it. Finally, new insights are provided for the development of natural hydrogel-based vascularized soft tissue regeneration research.


  • Open Access

    Comparative analysis of dental implant placement accuracy: Semi‐active robotic versus free‐hand techniques: A randomized controlled clinical trial

    by Fan Yang, Jianping Chen, Ruijue Cao, Qingwei Tang, Haiyan Liu, Yuchen Zheng, BeiLei Liu, Min Huang, Zhenshi Wang, Yude Ding, et al.

    Background: Robot‐assisted implant surgery has emerged as a novel digital technology, and the accuracy need further assessment.Purpose: This study aimed to compare the accuracy of single dental implant placement between a novel semi‐active robot‐assisted implant surgery (RAIS) method and the conventional free‐hand implant surgery (FHIS) method through a multicenter, randomized controlled clinical trial.Materials and Methods: Patients requiring single dental implant placement were recruited and randomized into RAIS and FHIS group. Deviations at the platform, apex, and angle between the planned and final implant positions were assessed in both groups. Additionally, the evaluation of instrument and surgical complications was examined.Results: A total of 140 patients (median age: 35.35 ± 12.55 years; 43 males, 97 females) with 140 implants from four different research centers were included, with 70 patients (70 implants) in the RAIS group and 70 patients (70 implants) in the FHIS group. In the RAIS and FHIS groups, the median platform deviations were 0.76 ± 0.36 mm and 1.48 ± 0.93 mm, respectively (p < 0.001); median apex deviations were 0.85 ± 0.48 mm and 2.14 ± 1.25 mm, respectively (p < 0.001); and median angular deviations were 2.05 ± 1.33° and 7.36 ± 4.67°, respectively (p < 0.001). Similar significant difference also presented between RAIS and FHIS group in platform vertical/horizontal deviation, apex vertical/horizontal deviation. Additionally, implants with self‐tapping characteristics exhibited significantly larger deviations compared with those without self‐tapping characteristics in the RAIS group. Both RAIS and FHIS methods demonstrated comparable morbidity and safety pre‐ and post‐operation.Conclusions: The results indicated that the RAIS method demonstrated superior accuracy in single dental implant placement compared with the FHIS method. Specifically, RAIS exhibited significantly smaller deviations in platform, apex, and angular positions, as well as platform and apex vertical/horizontal deviations.This clinical trial was not registered prior to participant recruitment and randomization. https://www.chictr.org.cn/showproj.html?proj=195045.


  • Open Access

    The fabrication and hemostasis of controlled-size chitosan microspheres:A preliminary research

    by Huajun Zhou, Chaojun Wen, Zhuoheng Xia, Yude Ding, Fan Yang

    Extreme bleeding can make therapy challenging or even fatal. Even though several commercial homeostatic medicines have favorable clinical results, there is still a desire to discover materials that are effective, bio-safe, inexpensive, and simple to produce. In this study, regulated and uniformly sized chitosan microspheres (CSM) were fabricated using a simple process and assessed as hemostatic agents. In addition, the diameter criteria for optimal hemostatic effects were evaluated. Precipitation and coaxial airflow shear technique were used to fabricate CSM with a controlled and homogeneous particle size. Secondly, scanning electron microscope and N2 adsorption-desorption isotherm characterization, water absorption experiments, and in vitro coagulation evaluation demonstrated that the CSM produced in this experiment have a porous structure, a high specific surface area, and a high-water absorption capacity. The hemostatic effect was investigated using a rabbit blood coagulation experiment in vitro. To further examine the hemostatic effect using an arterial/venous bleeding model in rats. The results were superior to those in the blank control group. The hemostatic effect is related to the diameter of the microspheres. In these experiments, large diameter chitosan microspheres possessed superior hemostatic effect. Hence, these novel CSM show considerable potential for use in hemostatic events and demonstrated a diameter-dependent hemostatic effect.