Tuğgen Özcivelek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tuğgen Özcivelek has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Fulya Basmaci
Department of Prosthodontics, Faculty of Dentistry, Ankara Yıldırım Beyazıt University, Ankara, Türkiye
3 shared publications - Berna Özcan
Department of Prosthodontics, Gülhane Faculty of Dentistry, University of Health Sciences, Ankara, Turkey
2 shared publications - Mehmet Ali Kılıçarslan
Department of Prosthodontics, Faculty of Dentistry, Ankara University, Ankara 06560, Turkey
2 shared publications - Berna Turgut
Ankara Memorial Hastanesi
1 shared publication - Ebru Tetik
Saglik Bilimleri Universitesi
1 shared publication - Kuddusi Akbulut
Department of Prosthodontics, Faculty of Dentistry, Cappadocia University, Nevşehir, Türkiye
1 shared publication
Latest Publications
- Open Access
- 13 March 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
The effect of muscle examination findings on determining conservative treatment options for temporomandibular joint disorders
Temporomandibular joint disorders are common in the community. Identifying the relationship between specific painful examination sites and the choice of co
- 13 March 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessThe effect of muscle examination findings on determining conservative treatment options for temporomandibular joint disorders
Temporomandibular joint disorders are common in the community. Identifying the relationship between specific painful examination sites and the choice of co
- Open Access
- 24 September 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Bond strength of maxillofacial silicone to various three-dimensional printing resins compared to conventional substructures
Bonding between silicone elastomers and rigid substructures is critical to clinical success of extraoral maxillofacial prostheses. This study aimed to investigate the bond strength of silicone elastomers to conventional and alternative 3-dimensional printing resin materials and the effect of artificial aging. The bond strength of seven resin substructure materials to a maxillofacial silicone was tested using the 180° peel test without artificial aging and after artificial aging in 14 groups. Test specimens composed of a silicone elastomer bonded to a substructure which were prepared according to ASTM D903-98 standard. A total of 70 specimens were prepared with a maxillofacial silicone bonded with a primer to substructures made of chemically polymerized clear acrylic, heat-polymerized clear acrylic and heat-polymerized pink acrylic, 3-dimensional surgical guide, 3-dimensional denture base, 3-dimensional polyetherketoneketone, and 3-dimensional polyetheretherketone resins (n = 10). Half of the specimens (n = 5 per group) were aged in an environmental chamber (Ci4400 Weather-Ometer, Atlas, Inc., USA) to assess the impact of 360 h of accelerated artificial aging. Peel bond strength values were analyzed using two-way ANOVA and post-hoc comparisons with Bonferroni correction (α = 0.05). Bond failures were classified using confocal microscopy. Substructure material, artificial aging, and their interaction significantly affected peel bond strength (p < 0.001). Polyetherketoneketone and polyetheretherketone exhibited significantly lower mean bond strength in non-aged groups (p < 0.05). Within the aged groups, surgical guide and denture base resins demonstrated significantly higher bond strength (p < 0.05). The most common failure type was mixed (71.4%), followed by adhesive (20%), cohesive (9%). Three-dimensional printed surgical guide resin and denture base resin specimens showed higher mean bond strength after artificial aging compared to commonly used conventional resin substructures and three- dimensional printed polyetherketoneketone and polyetheretherketone.
- 24 September 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Open AccessBond strength of maxillofacial silicone to various three-dimensional printing resins compared to conventional substructures
Bonding between silicone elastomers and rigid substructures is critical to clinical success of extraoral maxillofacial prostheses. This study aimed to investigate the bond strength of silicone elastomers to conventional and alternative 3-dimensional printing resin materials and the effect of artificial aging. The bond strength of seven resin substructure materials to a maxillofacial silicone was tested using the 180° peel test without artificial aging and after artificial aging in 14 groups. Test specimens composed of a silicone elastomer bonded to a substructure which were prepared according to ASTM D903-98 standard. A total of 70 specimens were prepared with a maxillofacial silicone bonded with a primer to substructures made of chemically polymerized clear acrylic, heat-polymerized clear acrylic and heat-polymerized pink acrylic, 3-dimensional surgical guide, 3-dimensional denture base, 3-dimensional polyetherketoneketone, and 3-dimensional polyetheretherketone resins (n = 10). Half of the specimens (n = 5 per group) were aged in an environmental chamber (Ci4400 Weather-Ometer, Atlas, Inc., USA) to assess the impact of 360 h of accelerated artificial aging. Peel bond strength values were analyzed using two-way ANOVA and post-hoc comparisons with Bonferroni correction (α = 0.05). Bond failures were classified using confocal microscopy. Substructure material, artificial aging, and their interaction significantly affected peel bond strength (p < 0.001). Polyetherketoneketone and polyetheretherketone exhibited significantly lower mean bond strength in non-aged groups (p < 0.05). Within the aged groups, surgical guide and denture base resins demonstrated significantly higher bond strength (p < 0.05). The most common failure type was mixed (71.4%), followed by adhesive (20%), cohesive (9%). Three-dimensional printed surgical guide resin and denture base resin specimens showed higher mean bond strength after artificial aging compared to commonly used conventional resin substructures and three- dimensional printed polyetherketoneketone and polyetheretherketone.
- Top Cited PapersOpen Access
- 31 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Comparative evaluation of responses from DeepSeek-R1, ChatGPT-o1, ChatGPT-4, and dental GPT chatbots to patient inquiries about dental and maxillofacial prostheses
Artificial intelligence chatbots have the potential to inform and guide patients by providing human-like responses to questions about dental and maxillofacial prostheses. Information regarding the accuracy and qualifications of these responses is limited. This in-silico study aimed to evaluate the accuracy, quality, readability, understandability, and actionability of the responses from DeepSeek-R1, ChatGPT-o1, ChatGPT-4, and Dental GPT chatbots. Four chatbots were queried about 35 of the most frequently asked patient questions about their prostheses. The accuracy, quality, understandability, and actionability of the responses were assessed by two prosthodontists using five-point Likert scale, Global Quality Score, and Patient Education Materials Assessment Tool for Printed Materials scales, respectively. Readability was scored using the Flesch-Kincaid Grade Level and Flesch Reading Ease. The agreement was assessed using the Cohen Kappa test. Differences between chatbots were analyzed using the Kruskal-Wallis test, one-way ANOVA, and post-hoc tests. Chatbots showed a significant difference in accuracy and readability (p <.05). Dental GPT recorded the highest accuracy score, whereas ChatGPT-4 had the lowest. DeepSeek-R1 performed best, while Dental GPT had the lowest performance in readability. Quality, understandability, actionability, and reader education scores did not show significant differences. While accuracy may vary among chatbots, the domain-specific trained AI tool and ChatGPT-o1 demonstrated superior accuracy. Even if accuracy is high, misinformation in health care can have significant consequences. Enhancing the readability of the responses is essential, and chatbots should be chosen accordingly. The accuracy and readability of information from chatbots should be monitored for public health.
- 31 May 2025
- Published by Springer Nature in BMC Oral Health
- Vol. 25 (1) , 1-9
Top Cited PapersOpen AccessComparative evaluation of responses from DeepSeek-R1, ChatGPT-o1, ChatGPT-4, and dental GPT chatbots to patient inquiries about dental and maxillofacial prostheses
Artificial intelligence chatbots have the potential to inform and guide patients by providing human-like responses to questions about dental and maxillofacial prostheses. Information regarding the accuracy and qualifications of these responses is limited. This in-silico study aimed to evaluate the accuracy, quality, readability, understandability, and actionability of the responses from DeepSeek-R1, ChatGPT-o1, ChatGPT-4, and Dental GPT chatbots. Four chatbots were queried about 35 of the most frequently asked patient questions about their prostheses. The accuracy, quality, understandability, and actionability of the responses were assessed by two prosthodontists using five-point Likert scale, Global Quality Score, and Patient Education Materials Assessment Tool for Printed Materials scales, respectively. Readability was scored using the Flesch-Kincaid Grade Level and Flesch Reading Ease. The agreement was assessed using the Cohen Kappa test. Differences between chatbots were analyzed using the Kruskal-Wallis test, one-way ANOVA, and post-hoc tests. Chatbots showed a significant difference in accuracy and readability (p <.05). Dental GPT recorded the highest accuracy score, whereas ChatGPT-4 had the lowest. DeepSeek-R1 performed best, while Dental GPT had the lowest performance in readability. Quality, understandability, actionability, and reader education scores did not show significant differences. While accuracy may vary among chatbots, the domain-specific trained AI tool and ChatGPT-o1 demonstrated superior accuracy. Even if accuracy is high, misinformation in health care can have significant consequences. Enhancing the readability of the responses is essential, and chatbots should be chosen accordingly. The accuracy and readability of information from chatbots should be monitored for public health.
- Open Access
- 1 January 2025
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 15 (1) , 226-231
Effect of Hypochlorous Acid on Acrylic Resins in Preventing Cross-infection Between Clinic and Laboratory
Objective: The COVID-19 pandemic and monkeypox disease have highlighted the importance of preventing cross-infection between dental laboratories and clinics. Thus, the aim of this study was to evaluate the effects of hypochlorous acid (HOCL), a natural disinfectant that is effective on bacteria and viruses, on polymethylmetacrylate (PMMA) to prevent cross-infection. Methods: A total of 120 PMMA (60 heat-activated and 60 three dimensionally printed) samples were prepared. The samples were immersed in HOCL and ortophtalaldehyde (OPA) disinfectant twice for 30 minutes to simulate the travel time to clinic and the dental laboratory. 10 samples from each group were kept in deionized water as a control group. Flexural strength and surface roughness measurements of the samples were performed. T-test and Kruskal Wallis H test were used for statistical evaluation (α=0.05). Results: There was no significant difference in flexural strength or Ra values between the HOCL and OPA groups. Conclusion: HOCL PMMA may be considered an alternative disinfectant for preventing cross-infection between dental laboratories and clinics in dentures and orthodontic appliances. Further research is required to evaluate its biological efficacy and long-term use.
- 1 January 2025
- Published by Marmara University in Clinical and Experimental Health Sciences
- Vol. 15 (1) , 226-231
Open AccessEffect of Hypochlorous Acid on Acrylic Resins in Preventing Cross-infection Between Clinic and Laboratory
Objective: The COVID-19 pandemic and monkeypox disease have highlighted the importance of preventing cross-infection between dental laboratories and clinics. Thus, the aim of this study was to evaluate the effects of hypochlorous acid (HOCL), a natural disinfectant that is effective on bacteria and viruses, on polymethylmetacrylate (PMMA) to prevent cross-infection. Methods: A total of 120 PMMA (60 heat-activated and 60 three dimensionally printed) samples were prepared. The samples were immersed in HOCL and ortophtalaldehyde (OPA) disinfectant twice for 30 minutes to simulate the travel time to clinic and the dental laboratory. 10 samples from each group were kept in deionized water as a control group. Flexural strength and surface roughness measurements of the samples were performed. T-test and Kruskal Wallis H test were used for statistical evaluation (α=0.05). Results: There was no significant difference in flexural strength or Ra values between the HOCL and OPA groups. Conclusion: HOCL PMMA may be considered an alternative disinfectant for preventing cross-infection between dental laboratories and clinics in dentures and orthodontic appliances. Further research is required to evaluate its biological efficacy and long-term use.
- Open Access
- 25 April 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 32 (7) , 553-559
Improvement of speech by facial prosthesis in a midfacial defect with a gunshot injury: A case report
Gunshot wounds in the maxillofacial region may cause serious defects that result in functional and esthetic disabilities. A 14‐year‐old male patient was referred to the prosthodontics clinic for provisional prosthetic restoration 5 months after an injury involving the midline midfacial region. An interim extraoral silicone maxillofacial prosthesis (MFP), also known as an epithesis, replacing the nose and upper lip, was fabricated to enhance appearance and speech intelligibility. The effect of the prosthesis insertion on speech outcome was assessed over 6 months. Blood pulse oxygen saturation levels and heart rate were monitored to assess ventilation following the prosthesis insertion. Results of the Assessment of Articulation Subtest revealed the patient produced the target speech sounds of 31 more words correctly at 6 months follow‐up. Bilabial, labiodental, and postalveolar speech sounds in the phonetic inventory improved. Fabrication of an extraoral silicone MFP, modifying substructure design, and prosthesis usage over time contributed to the significant enhancement of speech intelligibility and did not significantly change the blood pulse oxygen saturation levels and heart rate. It led to an improvement in overall aesthetic outcomes and was a useful tool for the patient's social integration.
- 25 April 2023
- Published by Wiley in Journal of Prosthodontics
- Vol. 32 (7) , 553-559
Open AccessImprovement of speech by facial prosthesis in a midfacial defect with a gunshot injury: A case report
Gunshot wounds in the maxillofacial region may cause serious defects that result in functional and esthetic disabilities. A 14‐year‐old male patient was referred to the prosthodontics clinic for provisional prosthetic restoration 5 months after an injury involving the midline midfacial region. An interim extraoral silicone maxillofacial prosthesis (MFP), also known as an epithesis, replacing the nose and upper lip, was fabricated to enhance appearance and speech intelligibility. The effect of the prosthesis insertion on speech outcome was assessed over 6 months. Blood pulse oxygen saturation levels and heart rate were monitored to assess ventilation following the prosthesis insertion. Results of the Assessment of Articulation Subtest revealed the patient produced the target speech sounds of 31 more words correctly at 6 months follow‐up. Bilabial, labiodental, and postalveolar speech sounds in the phonetic inventory improved. Fabrication of an extraoral silicone MFP, modifying substructure design, and prosthesis usage over time contributed to the significant enhancement of speech intelligibility and did not significantly change the blood pulse oxygen saturation levels and heart rate. It led to an improvement in overall aesthetic outcomes and was a useful tool for the patient's social integration.
- 10 August 2022
- Published by Wiley in Journal of Prosthodontics
- Vol. 31 (9) , 754-760
Perception of orbital epitheses evaluated with eye tracker
Purpose: Orbital epitheses replace a missing eyeball and surrounding soft tissue. Perception of epithesis in public gaze and the attention areas on the face are of interest. This study aimed to examine the differences in perception of orbital epitheses by prosthodontists, dentistry students, and laypeople with an objective evaluation tool that utilized eye‐tracking technology.Materials and methods: Twenty‐four frontal facial images of 12 patients who had orbital epitheses were viewed by 81 observers (prosthodontists, dentistry students, laypeople) in random order for 5 seconds each. Gaze data were analyzed. Kruskal‐Wallis H test with Bonferroni correction was used to compare parameters in groups and areas of interest.Results: First fixation duration at the mouth for symmetrical images were 0.30, 0.28, and 0.25 seconds for prosthodontists, students, and laypeople, respectively. Fixation duration at the mouth for the laypeople (0.27 second) was shorter than students (0.29 second) and prosthodontists (0.31 second) at symmetrical images. Time to the first fixation to epithesis, nose, and eye was significantly lower than the forehead and mouth for all groups. Fixation count at epithesis was 6.36 for prosthodontists, 5.64 for students, and 5.34 for laypeople.Conclusion: Eyes were of most significant interest for all observer groups in symmetrical images. Individuals dealing with dentistry, especially prosthodontists, paid more attention to the mouth region along with the eyes in symmetrical images, considering fixation duration and fixation count. Attention directed to epithesis by all groups was verified with objective and measurable criteria. Prosthodontists’ attention to epithesis and mouth was evident considering the four parameters measured.
- 10 August 2022
- Published by Wiley in Journal of Prosthodontics
- Vol. 31 (9) , 754-760
Perception of orbital epitheses evaluated with eye tracker
Purpose: Orbital epitheses replace a missing eyeball and surrounding soft tissue. Perception of epithesis in public gaze and the attention areas on the face are of interest. This study aimed to examine the differences in perception of orbital epitheses by prosthodontists, dentistry students, and laypeople with an objective evaluation tool that utilized eye‐tracking technology.Materials and methods: Twenty‐four frontal facial images of 12 patients who had orbital epitheses were viewed by 81 observers (prosthodontists, dentistry students, laypeople) in random order for 5 seconds each. Gaze data were analyzed. Kruskal‐Wallis H test with Bonferroni correction was used to compare parameters in groups and areas of interest.Results: First fixation duration at the mouth for symmetrical images were 0.30, 0.28, and 0.25 seconds for prosthodontists, students, and laypeople, respectively. Fixation duration at the mouth for the laypeople (0.27 second) was shorter than students (0.29 second) and prosthodontists (0.31 second) at symmetrical images. Time to the first fixation to epithesis, nose, and eye was significantly lower than the forehead and mouth for all groups. Fixation count at epithesis was 6.36 for prosthodontists, 5.64 for students, and 5.34 for laypeople.Conclusion: Eyes were of most significant interest for all observer groups in symmetrical images. Individuals dealing with dentistry, especially prosthodontists, paid more attention to the mouth region along with the eyes in symmetrical images, considering fixation duration and fixation count. Attention directed to epithesis by all groups was verified with objective and measurable criteria. Prosthodontists’ attention to epithesis and mouth was evident considering the four parameters measured.