BYBangchu Yang

Bangchu Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bangchu Yang has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    An Optimization Method for an Active Multi-Unit Prosthetic Socket with Dynamic Adaptability in Multi-Task Scenarios

    by Yawen Hu, Li Jiang, Chunying Zou, Bangchu Yang, Tianquan Han, Ming Cheng

    As a core functional component of the prosthetic system, the prosthetic socket’s adaptability to the residual limb is directly correlated with the prosthetic’s performance, comfort level, and safety profile. Although traditional sockets can satisfy basic suspension requirements, they commonly suffer from inherent drawbacks in practical applications, including uneven pressure distribution, poor air permeability, and inadequate adaptability to the morphological variations of individual residual limbs. To enhance socket adaptability across multi-task scenarios, this study proposes an intelligent physiological adaptation-based optimal design method for active upper-limb prosthetic sockets. Specifically, this method first employs a dynamic force optimization algorithm for multi-contact units oriented to prosthetic manipulation tasks, which real-timely optimizes the output force of each unit under varying external loads to achieve stable socket suspension with minimal interface pressure. Second, biomechanical experiments are conducted to obtain the pain threshold distribution characteristics of forearm soft tissues under compressive loads, thereby providing a physiological basis for the spatial layout of the contact units. Furthermore, the mechanical performance of different socket structures is evaluated under various representative task scenarios, with peak normal force, mean normal force, and force distribution variance adopted as the key comfort evaluation indices. The results demonstrate that the proposed active multi-unit socket, particularly the double-layered eight-unit symmetric radial staggered configuration, enables a robust balance between comfort and stability across diverse task scenarios, thereby establishing an effective and scalable design paradigm for long-term adaptive upper-limb prosthetic sockets.


  • Real-Time Tremor Monitoring and Estimation Using Multisensor Fusion for Wearable Active Suppression Systems

    by Kening Gong, Li Jiang, Siyang Qiu, Xiaoran Tang, Wenhao Wu, Bangchu Yang, Weihang Guo, Hong Liu

    Active tremor suppression devices have emerged as an essential treatment option alongside medication and surgical interventions for Parkinson's disease (PD). Rapid and accurate extraction of hand tremor signal features from PD patients is crucial for the effective operation of such devices. However, existing tremor signal monitoring schemes are limited by large real-time errors, high information redundancy, and bulky equipment, hindering practical applications. This study first employed multiple inertial measurement units (IMUs) and a myoelectric armband to perform multidimensional tremor data acquisition on PD patients. Based on the analysis and dimensionality reduction of multi-sensor data, the sensor layout was optimized, resulting in a lightweight and wearable monitoring module for active tremor suppression devices. Using the optimized monitoring module, additional tremor data were collected, and an EMG-guided (EMG-Guided) real-time tremor estimation algorithm was proposed and validated. This algorithm not only improves the real-time prediction accuracy of tremor motion data but also enables real-time recognition of tremor states, enhancing the robustness of monitoring. Experimental results show that the algorithm achieves a real-time estimation accuracy of 81.72% for PD tremor data. Compared to non-EMG-guided estimation schemes, the real-time estimation error is reduced by 34.35%. This study analyzes the hand characteristics of resting tremors in Parkinson's disease and introduces a novel and practical soft-hardware integrated solution, laying a solid foundation for wearable monitoring, diagnosis, and the development of advanced medical rehabilitation robots with active tremor suppression capabilities.


  • IPAS: A Compact Multi-Channel Pneumatic System With Embedded Hierarchical Control for Soft Dexterous Hands

    by Kehan Ding, Ruichen Zhen, Zhengchen Li, Bangchu Yang, Ming Cheng, Li Jiang

    Pneumatically actuated soft dexterous hands, featuring multiple independently actuated degrees of freedom (DoFs), are increasingly employed as robotic end-effectors for versatile manipulation tasks. However, current pneumatic systems are typically bulky with limited system-level integration. They rely on centralized architectures where a single processor handles all control tasks and lack support for large-scale multi-channel control, limiting their applicability to soft dexterous hands. To address these challenges, we present an Integrated Pneumatic Actuation System (IPAS) that integrates 20 independent channels within the wrist space, enabling direct deployment on a robotic arm. Compared to state-of-the-art systems, IPAS achieves a 67$\%$ increase in channel count while reducing system volume by two-thirds. An embedded hierarchical control architecture with a modular hardware-software design enables the coordinated and parallel execution of control, sensing, and valve actuation. Experimental results demonstrate RMSEs of 0.3 kPa in steady-state pressure control and 1.8 kPa in pressure trajectory tracking. The multi-channel actuation capability is further validated through teleoperated and autonomous grasping experiments. The modular design of the IPAS valve array and control units ensures maintainability, scalability, and algorithmic flexibility, providing a general-purpose hardware-software platform for soft dexterous hand control and manipulation research.


  • Evolving Robotic Hand Morphology Through Grasping and Learning

    by Bangchu Yang, Li Jiang, Wenhao Wu, Ruichen Zhen

    Creatures can co-evolve their biological structures and behaviors under environmental pressures. Leveraging biomimetic evolution algorithms (referred to as co-design or co-optimization), a diverse range of robots with environmental adaptation has been generated. However, implementing these evolutionary methods or results in real-world robots, especially in the case of robotic hands, was not easy. In this context, this work presents a comprehensive self-optimization scheme for robotic hands that encompasses both software and hardware components. This scheme enables robots to autonomously refine their morphology through the integration of hardware gradients and reinforcement learning within parallel environments, thereby enhancing their adaptability to a variety of grasping tasks. For the hardware aspect, we developed a reconfigurable hand prototype with 37 variable hardware parameters (i.e., joint stiffness, the length of phalanges, finger location, and palm curvature) adjusted by mechanical components. Leveraging the adjustable hardware and 20 motors, this hand achieves full actuation and can dynamically adjust its morphology. The training results indicate that the fitness score of the self-optimizing hand exceeds that of original designs in this instance. The hardware parameters can be further fine-tuned in response to task variations. Moreover, the evolved hardware parameters are transferred to a real-world reconfigurable hand, demonstrating its grasping and adaptivity capabilities.


  • Decomposition strategy for surface EMG with few channels: a simulation study

    by Wenhao Wu, Li Jiang, Bangchu Yang

    Objective. In the specific use of electromyogram (EMG) driven prosthetics, the user’s disability reduces the space available for the electrode array. We propose a framework for EMG decomposition adapted to the condition of a few channels (less than 30 observations), which can elevate the potential of prosthetics in terms of cost and applicability. Approach. The new framework contains a peel-off approach, a refining strategy for motor unit (MU) spike train and MU action potential and a re-subtracting strategy to adapt the framework to few channels environments. Simulated EMG signals were generated to test the framework. In addition, we quantify and analyze the effect of strategies used in the framework. Main results. The results show that the new algorithm has an average improvement of 19.97% in the number of MUs identified compared to the control algorithm. Quantitative analysis of the usage strategies shows that the re-subtracting and refining strategies can effectively improve the performance of the framework under the condition of few channels. Significance. These prove that the new framework can be applied to few channel conditions, providing a optimization space for neural interface design in cost and user adaptation.


  • Open Access

    A Semi-Autonomous Hierarchical Control Framework for Prosthetic Hands Inspired by Dual Streams of Human

    by Xuanyi Zhou, Jianhua Zhang, Bangchu Yang, Xiaolong Ma, Hao Fu, Shibo Cai, Guanjun Bao

    The routine use of prosthetic hands significantly enhances amputees’ daily lives, yet it often introduces cognitive load and reduces reaction speed. To address this issue, we introduce a wearable semi-autonomous hierarchical control framework tailored for amputees. Drawing inspiration from the visual processing stream in humans, a fully autonomous bionic controller is integrated into the prosthetic hand control system to offload cognitive burden, complemented by a Human-in-the-Loop (HIL) control method. In the ventral-stream phase, the controller integrates multi-modal information from the user’s hand–eye coordination and biological instincts to analyze the user’s movement intention and manipulate primitive switches in the variable domain of view. Transitioning to the dorsal-stream phase, precise force control is attained through the HIL control strategy, combining feedback from the prosthetic hand’s sensors and the user’s electromyographic (EMG) signals. The effectiveness of the proposed interface is demonstrated by the experimental results. Our approach presents a more effective method of interaction between a robotic control system and the human.


  • Co-optimization of robotic design and skill inspired by human hand evolution

    by Bangchu Yang, Li Jiang, Guanjun Bao, Haoyong Yu, Xuanyi Zhou

    During evolution of the human hand, evolutionary morphology has been closely related to behavior in complicated environments. Numerous researchers have revealed that learned skills have affected hand evolution. Inspired by this phenomenon, a co-optimization approach for underactuated hands is proposed that takes grasping skills and structural parameters into consideration. In our proposal, hand design, especially the underactuated mechanism, can be parameterized and shared with all the local agents. These mechanical parameters can be updated globally by the independent agents. In addition, we also train human-like ‘feeling’ of grasping: grasping stability is estimated in advance before the object drops, which can speed up grasping training. In this paper, our method is instantiated to address the optimization problem for the torsion spring mechanical parameters of an underactuated robotic hand with multi-actuators, and then the optimized results are transferred to the actual physical robotic hand to test the improvement of grasping. This collaborative evolution process leverages the dexterity of the multi-actuators and the adaptivity of the underactuated mechanism.