Wenhao Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Wenhao Wu has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Bangchu Yang
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
4 shared publications - Li Jiang
State Key Laboratory of Robotics and Systems, Harbin Institute of Technology, Harbin, China
3 shared publications - Kening Gong
School of Mechatronics Engineering, Harbin Institute of Technology, Harbin, China
2 shared publications - Hong Liu
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China
1 shared publication Li Jiang
State Key Laboratory of Robotics and System, Harbin Institute of Technology, No. 92, Xidazhi Street, Harbin, China, Harbin, Heilongjiang, 150001, CHINA
1 shared publication- Ming Cheng
State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
1 shared publication
Latest Publications
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Real-Time Tremor Monitoring and Estimation Using Multisensor Fusion for Wearable Active Suppression Systems
Active tremor suppression devices have emerged as an essential treatment option alongside medication and surgical interventions for Parkinson's disease (PD). Rapid and accurate extraction of hand tremor signal features from PD patients is crucial for the effective operation of such devices. However, existing tremor signal monitoring schemes are limited by large real-time errors, high information redundancy, and bulky equipment, hindering practical applications. This study first employed multiple inertial measurement units (IMUs) and a myoelectric armband to perform multidimensional tremor data acquisition on PD patients. Based on the analysis and dimensionality reduction of multi-sensor data, the sensor layout was optimized, resulting in a lightweight and wearable monitoring module for active tremor suppression devices. Using the optimized monitoring module, additional tremor data were collected, and an EMG-guided (EMG-Guided) real-time tremor estimation algorithm was proposed and validated. This algorithm not only improves the real-time prediction accuracy of tremor motion data but also enables real-time recognition of tremor states, enhancing the robustness of monitoring. Experimental results show that the algorithm achieves a real-time estimation accuracy of 81.72% for PD tremor data. Compared to non-EMG-guided estimation schemes, the real-time estimation error is reduced by 34.35%. This study analyzes the hand characteristics of resting tremors in Parkinson's disease and introduces a novel and practical soft-hardware integrated solution, laying a solid foundation for wearable monitoring, diagnosis, and the development of advanced medical rehabilitation robots with active tremor suppression capabilities.
- 11 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Real-Time Tremor Monitoring and Estimation Using Multisensor Fusion for Wearable Active Suppression Systems
Active tremor suppression devices have emerged as an essential treatment option alongside medication and surgical interventions for Parkinson's disease (PD). Rapid and accurate extraction of hand tremor signal features from PD patients is crucial for the effective operation of such devices. However, existing tremor signal monitoring schemes are limited by large real-time errors, high information redundancy, and bulky equipment, hindering practical applications. This study first employed multiple inertial measurement units (IMUs) and a myoelectric armband to perform multidimensional tremor data acquisition on PD patients. Based on the analysis and dimensionality reduction of multi-sensor data, the sensor layout was optimized, resulting in a lightweight and wearable monitoring module for active tremor suppression devices. Using the optimized monitoring module, additional tremor data were collected, and an EMG-guided (EMG-Guided) real-time tremor estimation algorithm was proposed and validated. This algorithm not only improves the real-time prediction accuracy of tremor motion data but also enables real-time recognition of tremor states, enhancing the robustness of monitoring. Experimental results show that the algorithm achieves a real-time estimation accuracy of 81.72% for PD tremor data. Compared to non-EMG-guided estimation schemes, the real-time estimation error is reduced by 34.35%. This study analyzes the hand characteristics of resting tremors in Parkinson's disease and introduces a novel and practical soft-hardware integrated solution, laying a solid foundation for wearable monitoring, diagnosis, and the development of advanced medical rehabilitation robots with active tremor suppression capabilities.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (10) , 8475-8482
Evolving Robotic Hand Morphology Through Grasping and Learning
Creatures can co-evolve their biological structures and behaviors under environmental pressures. Leveraging biomimetic evolution algorithms (referred to as co-design or co-optimization), a diverse range of robots with environmental adaptation has been generated. However, implementing these evolutionary methods or results in real-world robots, especially in the case of robotic hands, was not easy. In this context, this work presents a comprehensive self-optimization scheme for robotic hands that encompasses both software and hardware components. This scheme enables robots to autonomously refine their morphology through the integration of hardware gradients and reinforcement learning within parallel environments, thereby enhancing their adaptability to a variety of grasping tasks. For the hardware aspect, we developed a reconfigurable hand prototype with 37 variable hardware parameters (i.e., joint stiffness, the length of phalanges, finger location, and palm curvature) adjusted by mechanical components. Leveraging the adjustable hardware and 20 motors, this hand achieves full actuation and can dynamically adjust its morphology. The training results indicate that the fitness score of the self-optimizing hand exceeds that of original designs in this instance. The hardware parameters can be further fine-tuned in response to task variations. Moreover, the evolved hardware parameters are transferred to a real-world reconfigurable hand, demonstrating its grasping and adaptivity capabilities.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics and Automation Letters
- Vol. 9 (10) , 8475-8482
Evolving Robotic Hand Morphology Through Grasping and Learning
Creatures can co-evolve their biological structures and behaviors under environmental pressures. Leveraging biomimetic evolution algorithms (referred to as co-design or co-optimization), a diverse range of robots with environmental adaptation has been generated. However, implementing these evolutionary methods or results in real-world robots, especially in the case of robotic hands, was not easy. In this context, this work presents a comprehensive self-optimization scheme for robotic hands that encompasses both software and hardware components. This scheme enables robots to autonomously refine their morphology through the integration of hardware gradients and reinforcement learning within parallel environments, thereby enhancing their adaptability to a variety of grasping tasks. For the hardware aspect, we developed a reconfigurable hand prototype with 37 variable hardware parameters (i.e., joint stiffness, the length of phalanges, finger location, and palm curvature) adjusted by mechanical components. Leveraging the adjustable hardware and 20 motors, this hand achieves full actuation and can dynamically adjust its morphology. The training results indicate that the fitness score of the self-optimizing hand exceeds that of original designs in this instance. The hardware parameters can be further fine-tuned in response to task variations. Moreover, the evolved hardware parameters are transferred to a real-world reconfigurable hand, demonstrating its grasping and adaptivity capabilities.
- 31 May 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (3) , 036026
Decomposition strategy for surface EMG with few channels: a simulation study
Objective. In the specific use of electromyogram (EMG) driven prosthetics, the user’s disability reduces the space available for the electrode array. We propose a framework for EMG decomposition adapted to the condition of a few channels (less than 30 observations), which can elevate the potential of prosthetics in terms of cost and applicability. Approach. The new framework contains a peel-off approach, a refining strategy for motor unit (MU) spike train and MU action potential and a re-subtracting strategy to adapt the framework to few channels environments. Simulated EMG signals were generated to test the framework. In addition, we quantify and analyze the effect of strategies used in the framework. Main results. The results show that the new algorithm has an average improvement of 19.97% in the number of MUs identified compared to the control algorithm. Quantitative analysis of the usage strategies shows that the re-subtracting and refining strategies can effectively improve the performance of the framework under the condition of few channels. Significance. These prove that the new framework can be applied to few channel conditions, providing a optimization space for neural interface design in cost and user adaptation.
- 31 May 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (3) , 036026
Decomposition strategy for surface EMG with few channels: a simulation study
Objective. In the specific use of electromyogram (EMG) driven prosthetics, the user’s disability reduces the space available for the electrode array. We propose a framework for EMG decomposition adapted to the condition of a few channels (less than 30 observations), which can elevate the potential of prosthetics in terms of cost and applicability. Approach. The new framework contains a peel-off approach, a refining strategy for motor unit (MU) spike train and MU action potential and a re-subtracting strategy to adapt the framework to few channels environments. Simulated EMG signals were generated to test the framework. In addition, we quantify and analyze the effect of strategies used in the framework. Main results. The results show that the new algorithm has an average improvement of 19.97% in the number of MUs identified compared to the control algorithm. Quantitative analysis of the usage strategies shows that the re-subtracting and refining strategies can effectively improve the performance of the framework under the condition of few channels. Significance. These prove that the new framework can be applied to few channel conditions, providing a optimization space for neural interface design in cost and user adaptation.