CFChin-Chuan Fu

Chin-Chuan Fu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Chin-Chuan Fu has a total of 49 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparative Cytotoxicity of Commercially Pure Titanium, Silver–Palladium and Nickel–Chromium Alloys on Human Gingival Fibroblasts: An In Vitro Study

    by Passent Ellakany, Zakia AbdelRahman, Chin-Chuan Fu, Noha Abdelsamad, Akram Sayed Ahmed

    Background/Objectives: This study aimed to evaluate the direct effect of elements released from dental casting alloys on human gingival fibroblasts (HGF). Methods: Ten discs each of commercially pure titanium (Ti), silver-palladium (Ag-Pd), and nickel-chromium (Ni-Cr) alloys, measuring 4 mm in diameter and 3 mm in thickness, were fabricated and placed directly on HGF cultures for 72 h. Five discs from each alloy group were incubated in DMEM, whereas the remaining five discs were incubated in artificial saliva. Cytotoxicity was assessed using three in vitro methods: morphological evaluation of HGF, the dye exclusion test (DET), and the methyl-thiazolyl-tetrazolium (MTT) colorimetric assay. Results: HGF directly exposed to cpTi, Ag-Pd, and Ni-Cr discs demonstrated reduced cell density around the alloy specimens compared with untreated control cells after 72 h of incubation in both DMEM and artificial saliva. cpTi alloy exhibited no detectable cytotoxic effects, whereas Ag-Pd and Ni-Cr alloys demonstrated cytotoxicity in both DMEM and artificial saliva under the experimental conditions. Among the tested alloys, Ni-Cr exhibited the highest cytotoxicity. Artificial saliva enhanced the cytotoxic effects of the tested alloys, as evidenced by increased morphological alterations, reduced cell viability, and lower MTT activity compared with DMEM. Conclusions: cpTi alloy exhibited the lowest direct cytotoxic effect on HGF in both DMEM and artificial saliva. In contrast, Ag-Pd and Ni-Cr alloys demonstrated greater cytotoxicity, particularly in the presence of artificial saliva, suggesting that both alloy composition and the surrounding environment influence the biological response of oral soft tissues.

  • Open Access

    Toothbrush Resistance of Resin-Based Stain and Glaze Materials Applied to 3D-Printed Denture Resins

    by Panisa Homyai, Ting-Chia Liu, Princy Thakkar, Chin-Chuan Fu, Nathaniel C. Lawson, Rama Kiran Chavali

    Three-dimensional (3D)-printed dentures are often fabricated from a single tooth-colored resin and externally characterized using stains and glaze coatings to enhance gingival esthetics and surface properties. However, routine toothbrushing may degrade these coatings, potentially affecting surface gloss and roughness. This study evaluated the effects of stain timing and glaze application on the gloss and surface roughness of a 3D-printed denture resin following simulated toothbrushing. Eighty disc-shaped specimens (12 mm × 3 mm) were fabricated and assigned to two staining systems (OPTIGLAZE Color and Palette 2.0), with subgroups based on stain timing (before or after post-curing) and glaze application (with or without glaze) (n = 10). Specimens underwent 20,000 cycles of simulated toothbrushing, and gloss and surface roughness were measured before and after brushing. Data were analyzed using two-way ANOVA (α = 0.05). Glaze application significantly improved gloss retention for both staining systems (p < 0.001), while stain timing had no independent effect. Glaze application with Palette 2.0 demonstrated improved gloss retention when post-cured in a post-curing unit. Toothbrushing increased surface roughness in all groups, with no significant effects of stain timing or glaze. Within the limitations of this study, glaze improves gloss stability, whereas stain timing has minimal influence and does not affect surface roughness.

  • Open Access

    Implementation of a Structured Preclinical Simulation Tool for Locator Housing Pick-Up Training

    by Po-Hsu Chen, Chin-Chuan Fu, Daniel A. Givan

    Background/Objectives: Delivering consistent preclinical instruction for implant attachment procedures can be challenging in large dental cohorts. This report describes the development and implementation of institutionally produced training tools designed to support Locator housing pick-up exercises for second-year predoctoral dental students. Methods: Modified typodont-based simulation tools were integrated into the preclinical curriculum. Clear dentures and gypsum models were fabricated to allow visualization of seating relationships and identification of common interferences. Complete seating of the denture was verified using inspection windows, flange evaluation, and polyvinylsiloxane disclosing materials before housings were incorporated with autopolymerizing acrylic resin. After each session, components were collected, inspected, and prepared for reuse in subsequent cycles. Learner perceptions were obtained through an anonymous voluntary survey. Results: The configuration enabled visualization of seating conditions and identification of misalignment during the exercise. Removal of anterior teeth reduced material use and emphasized posterior stabilization during the pick-up procedure. Of 83 learners, 28 completed the survey (34% response rate), with responses tending toward agreement across items (mean range: 4.5–4.9/5), indicating favorable learner perceptions of the exercise and its organization within the scheduled laboratory period. Across three academic cycles, six dentures required replacement, whereas all gypsum models remained serviceable and no additional fabrication was necessary. Conclusions: This structured simulation approach provided an alternative method for delivering Locator housing pick-up training in a high-volume preclinical environment. The model allowed repeated implementation of the exercise across academic cycles.

  • Open Access

    Fracture resistance of chairside cad/cam advanced lithium disilicate maxillary canine veneers with different incisal edge designs

    by Silvia Rojas-Rueda, Hidehiko Watanabe, Salah Abuhammoud, Carlos A. Jurado, Abdullah Alshehri, Chin-Chuan Fu, Daniel Vegh, Khalid M. Aldosary, Hamad Algamaiah, Abdulrahman Alshabib

    This study aimed to evaluate the fracture resistance of maxillary veneers with feather edge, butt-joint and palatal chamfer and traditional full coverage crowns fabricated out of chairside CAD/CAM advanced lithium disilicate and virgilite. Fifty-two restorations for maxillary right canine were fabricated (n = 13 per group) as follows: veneers with feather edge, veneers with butt-joint, veneers with palatal chamfer and full coverage crowns out of chairside CAD/CAM lithium disilicate and virgilite (Cerec Tessera). The restorations were bonded to 3D printed resin dies with resin cement (Variolink Esthetic LC). The cemented restorations were subjected to 10,000 thermocycles at 5 to 55 °C with a dwell time of 30 s. The specimens were loaded until fracture using a universal testing machine and the resistance was recorded in Newtons. Two-way ANOVA was used to assess the fracture resistance among veneers with different incisal edge designs and between veneers and crowns. Scanning electron microscope (SEM) images of the fractured specimens were taken and descriptive analysis was carried out. Full coverage crowns displayed higher fracture resistance (1496 ± 41 N) than any type of veneers. Veneers with palatal chamfer showed the highest value (842 ± 28 N) among veneers followed by butt joint veneers (661 ± 22 N). Feather edge veneers provided the lowest fracture resistance values (464 ± 23 N). The fracture resistance of CAD/CAM advanced lithium disilicate maxillary veneers are significantly influenced by the incisal edge design. Palatal chamfer veneers displayed higher fracture resistance than feather edge and butt joint veneers. Full coverage crowns offered higher fracture resistance than any type of veneer.


  • Open Access

    The Effect of Zirconia Material and the Height of the Ceramic Coping on the Strength of Hybrid Ti-Ceramic Abutments

    by Aikaterini Anastasaki, Pranit Bora, Stefanos Kourtis, Chin Chuan Fu

    The existing scientific literature lacks comprehensive information regarding the influence of zirconia crown height on debonding and fracture of the ceramic restorations on titanium base abutments. Additionally, there is a lack of comparative studies evaluating different types of zirconia as restorative options for screw-retained restorations. Purpose: The purpose of this study was to assess the fracture strength and the failure modes of the zirconia crown/titanium abutment complex by investigating the impact of increasing the height of zirconia crown and comparing different types of zirconia (3 mol% yttria-stabilized zirconia and translucent 5 mol% yttria-stabilized zirconia). Materials and Methods: Six groups of 10 specimens in each group were fabricated. Three groups of specimens (groups # 1, 2, and 3) were fabricated from 3Y zirconia in corresponding heights of 8, 10, and 12 mm. Three more groups (groups # 4, 5, and 6) were fabricated from 5Y zirconia in the same heights (8, 10 and 12 mm). All copings were bonded to 4 mm high titanium base abutments using dual-polymerization resin cement. The specimens underwent load cycling of 100,000 cycles with a force of 100 N. Subsequently, the specimens were loaded to compression until fracture and the failure mode was visually evaluated. Results: Statistically significant differences in fracture strength were noted among all tested groups. Conclusions: 3Y zirconia showed increased strength compared to 5Y in all heights. Ceramic copings with lower height showed increased strength compared to higher copings in both tested zirconia materials.


  • Open Access

    Fracture resistance of CAD/CAM milled versus direct hand-made interim laminate veneers

    by Salahaldeen Abuhammoud, Banan Emtier, Chin-Chuan Fu, Silvia Rojas-Rueda, Carlos A. Jurado, Kelvin I. Afrashtehfar

    Background: Comparative studies of interim veneer restorations crafted using subtractive computer-aided manufacturing (s-CAM) milling technology and traditional direct hand-made approaches are needed. Purpose: This comparative in vitro study evaluated the fracture resistance of two types of provisional veneer restorations for maxillary central incisors: milled (s-CAM) and traditional direct hand-made bis-acryl veneers. Materials and methods Fifty maxillary right central incisor veneers (25 specimens per group) were fabricated and divided according to the fabrication method: (1) s-CAM milled (Structure CAD, VOCO Dental); and (2) hand-made (Protemp Plus, 3M). The restorations were cemented onto 3D-printed resin dies using temporary cement and subjected to 1000 cycles of thermal cycling between 5° and 55 °C. These restorations subsequently were subjected to compressive loading until fracture occurred. Images of the fractured samples were captured using a scanning electron microscope (SEM). Statistical analysis was performed using the one-way ANOVA test and the Mann-Whitney U test. Results: Significant differences (p < 0.001) in the fracture resistance were observed between the two groups. s-CAM milled interim veneers displayed higher fracture resistance values (439.60 ± 26 N) compared to the traditional method (149.15 ± 10 N). Conclusion: The manufacturing method significantly influences the fracture resistance of interim veneer restorations. s-CAM interim laminate veneer restorations for maxillary central incisors exhibit a fracture resistance superior to that of the traditional method using bis-acryl. Clinical relevance Clinicians should consider CAD/CAM milled veneers for scenarios demanding long-term interim restoration and the withstanding of high occlusal forces.


  • Fracture resistance of chairside CAD‐CAM lithium disilicate occlusal veneer with various designs after mechanical aging

    by Carlos A Jurado, Akimasa Tsujimoto, Joseph Molisani, Chin‐Chuan Fu, Ramtin Sadid‐Zadeh

    Purpose: This study evaluated the fracture resistance of chairside computer‐aided design and computer‐aided manufacturing (CAD‐CAM) lithium disilicate crown, onlay, and non‐anatomical occlusal veneer (A‐OV) with and without margin fabricated.Materials and Methods: Sixty‐four CAD‐CAM lithium disilicate restorations were designed as (1) complete coverage crown (CCC); (2) A‐OV with margin; (3) non‐A‐OV with margin (NA‐OV‐M); and (4) non‐A‐OV without margin (NA‐OV‐NM), 16 of each. Restorations were crystallized and adhesively luted to resin dies using resin cement. Specimens were then subjected to 400,000 cycles of chewing in a mastication simulator. A universal testing machine was used to apply a compressive load at a crosshead speed of 1 mm/min to the long axis of the tooth with a stainless‐steel sphere until fracture occurred. One‐way ANOVA followed by post hoc tests were used to assess the impact of preparation design on the fracture load of CAD‐CAM lithium disilicate restorations.Results: The highest fracture load was recorded for CAD‐CAM lithium disilicate indirect restorations for non‐A‐OVs preparation with margin (2549 ± 428 N) and onlay (2549 ± 293 N) and the lowest fracture load was recorded for CCCs (2389 ± 428 N); however, there was no significant (p = 0.640) between groups.Conclusions: CAD‐CAM lithium disilicate restorations fabricated for anatomical and non‐A‐OV preparation display a fracture resistance similar to CCCs. Conservative partial coverage restorations may be considered an acceptable approach for posterior teeth.


  • Open Access

    The Influence of Thickness on Light Transmission for Pre- and Fully Crystallized Chairside CAD/CAM Lithium Disilicate Ceramics

    by Franciele Floriani, Salahaldeen Abuhammoud, Silvia Rojas-Rueda, Amit Unnadkat, Nicholas G. Fischer, Chin-Chuan Fu, Carlos A. Jurado

    Aim: This in vitro study aimed to compare the light-transmission properties of two chairside CAD/CAM lithium disilicate (LD) ceramics (a novel fully crystallized and a traditional pre-crystallized) across varying thicknesses. Materials and Methods: One hundred flat specimens were obtained from precrystallized (e.max CAD, Ivoclar Vivadent, Schaan, Liechtenstein) and fully crystallized (LiSi GC Block; GC, Tokyo, Japan) LD at five different thicknesses (0.5, 0.75, 1.0, 1.50 and 2.0 mm). All specimens were polished with a polishing system for lithium disilicate restorations following recommendations from the manufacturer. Light transmission was evaluated with a radiometer. The statistical analysis between e.max CAD and LiSi GC Block was performed using a Mann–Whitney test for each thickness at a significance level of 0.05 (p < 0.05), followed by a Kruskal–Wallis test to compare the light transmission between the thicknesses of e.max CAD and LiSi GC Block. Results: Light transmittance was significantly affected by ceramic thickness. The 0.5 mm thick specimens exhibited the highest transmittance values compared to all other groups, while a light transmittance of 0.00 was observed in the 2.0 mm thick specimens for both e.max CAD and LiSi GC Block. In the comparison between e.max CAD and LiSi GC Block according to thickness, there was a statistically significant difference exclusively between groups with a thickness of 1.50 mm (p = 0.002). Conclusions: Light transmission for pre- and fully crystallized CAD/CAM lithium disilicate ceramics only showed a statistical difference at the thickness of 1.50 mm (p = 0.002). E.max CAD demonstrated acceptable light transmission up to a thickness of 1.5 mm. Clinical Significance: A thickness of 2 mm for chairside CAD/CAM lithium disilicate ceramics, whether pre-crystallized or fully crystallized, necessitates the use of dual-cure resin luting cement due to reduced light transmission.


  • Open Access

    The Effect of Die Material on the Crown Fracture Strength of Zirconia Crowns

    by Akram Sayed Ahmed, Nathaniel C. Lawson, Chin-Chuan Fu, Pranit V. Bora, Edwin Kee, Amir H. Nejat

    Background: Determination of the eligibility of several tooth analog materials for use in crown fracture testing. Methods: A standardized premolar crown preparation was replicated into three types of resin dies (C&B, low modulus 3D printed resin; OnX, high modulus 3D printed resin composite; and highest modulus milled resin composite). 0.8 mm zirconia crowns were bonded to the dies and the maximum fracture load of the crowns was tested. Twelve extracted human premolars were prepared to a standardized crown preparation, and duplicate dies of the prepared teeth were 3D printed out of C&B. Zirconia crowns were bonded to both the dies and natural teeth, and their fracture load was tested. Results: There was no statistical difference between the fracture load of zirconia crowns bonded to standardized dies of C&B (1084.5 ± 134.2 N), OnX (1112.7 ± 109.8 N) or Lava Ultimate (1137.5 ± 88.7 N) (p = 0.580). There was no statistical difference between the fracture load of crowns bonded to dentin dies (1313 ± 240 N) and a 3D-printed resin die (C&B, 1156 ± 163 N) (p = 0.618). Conclusions: There was no difference in the static fracture load of zirconia crowns bonded to standardized resin dies with different moduli or between a low modulus resin die and natural dentin die.


  • Open Access

    Expediting the Rehabilitation of Severely Resorbed Ridges Using a Combination of CAD-CAM and Analog Techniques: A Case Report

    by Carlos A. Jurado, Francisco X. Azpiazu-Flores, Chin-Chuan Fu, Silvia Rojas-Rueda, Gerardo Guzman-Perez, Franciele Floriani

    With the life expectancy increasing, there is a growing need for prosthetic dental treatments to restore the oral health, function, and quality of life of edentulous patients. Presently, only a few articles are available describing the oral rehabilitation of patients with severely resorbed ridges with milled complete dentures. This clinical case report provides a straightforward protocol consisting of a combination of analog and digital techniques for the rehabilitation of edentulous patients with severely resorbed ridges with milled fixed and removable complete dentures. This technique permits the minimization of the number of appointments, improves patient comfort, allows for the digital archiving of important clinical data, and permits the manufacture of prostheses with improved mechanical properties. These favorable outcomes were achieved by using the patient’s existing PMMA complete denture as a custom tray for a final impression with light-bodied Polyvinylsiloxane. Subsequently, the resulting models were digitized, and a digital complete denture was designed and manufactured in an expedited manner using CAD-CAM techniques. Therefore, this case report highlights the potential of CAD/CAM technology to predictably restabilize oral functions and improve patients’ quality of life.