SJSebastiaan A. M. de Jongh

Sebastiaan A. M. de Jongh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Sebastiaan A. M. de Jongh has a total of 25 co-authors. Here are the top co-authors by number of shared publications:

  • Dennis C. J. J. Bergmans

    Department of Intensive Care Medicine, Maastricht University Medical Center+ (MUMC+), Maastricht, the Netherlands; School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, the Netherlands

    3 shared publications
  • Iwan Cornelis Clemens van der Horst

    Albert Schweitzer Hospital, Dordrecht, the Netherlands

    3 shared publications
  • Serge Jan Hubert Heines

    Department of Intensive Care Medicine, Maastricht University Medical Center+ (MUMC+), Maastricht, the Netherlands; School of Nutrition and Translational Research in Metabolism (NUTRIM), Maastricht University, Maastricht, the Netherlands

    3 shared publications
  • Bas C. T. van Bussel

    1 shared publication
  • Bas C. T. van Bussel

    Department of Intensive Care Medicine, Maastricht University Medical Centre+, Maastricht, The Netherlands

    1 shared publication
  • Bas C.T. van Bussel

    Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Maastricht, the Netherlands; Department of Intensive Care Medicine, Maastricht University Medical Centre (MUMC+), Maastricht, the Netherlands; Care and Public Health Research Institute (CAPHRI), Maastricht University, Maastricht, the Netherlands

    1 shared publication

Latest Publications

  • Open Access

    Vulnerabilities of feature clustering in EIT radiomics

    by Maike S.V. Imkamp, Vasco C.G. Prudente, Eda Aydeniz, Frank van Rosmalen, Sebastiaan de Jongh, Sander M.J. van Kuijk, Christof Seiler, Joep Schellens, Mariëlle Driessen, Serge J.H. Heines, et al.

  • Open Access

    A novel positive end-expiratory pressure titration using electrical impedance tomography in spontaneously breathing acute respiratory distress syndrome patients on mechanical ventilation: an observational study from the MaastrICCht cohort

    by S.J.H. Heines, S.A.M. de Jongh, F.H.C. de Jongh, R.P.J. Segers, K.M.H. Gilissen, I.C.C. van der Horst, B.C.T. van Bussel, D.C.J.J. Bergmans

    There is no universally accepted method for positive end expiratory pressure (PEEP) titration approach for patients on spontaneous mechanical ventilation (SMV). Electrical impedance tomography (EIT) guided PEEP-titration has shown promising results in controlled mechanical ventilation (CMV), current implemented algorithm for PEEP titration (based on regional compliance measurements) is not applicable in SMV. Regional peak flow (RPF, defined as the highest inspiratory flow rate based on EIT at a certain PEEP level) is a new method for quantifying regional lung mechanics designed for SMV. The objective is to study whether RPF by EIT is a feasible method for PEEP titration during SMV. Single EIT measurements were performed in COVID-19 ARDS patients on SMV. Clinical (i.e., tidal volume, airway occlusion pressure, end-tidal CO2) and mechanical (cyclic alveolar recruitment, recruitment, cumulative overdistension (OD), cumulative collapse (CL), pendelluft, and PEEP) outcomes were determined by EIT at several pre-defined PEEP thresholds (1–10% CL and the intersection of the OD and CL curves) and outcomes at all thresholds were compared to the outcomes at baseline PEEP. In total, 25 patients were included. No significant and clinically relevant differences were found between thresholds for tidal volume, end-tidal CO2, and P0.1 compared to baseline PEEP; cyclic alveolar recruitment rates changed by -3.9% to -37.9% across thresholds; recruitment rates ranged from − 49.4% to + 79.2%; cumulative overdistension changed from − 75.9% to + 373.4% across thresholds; cumulative collapse changed from 0% to -94.3%; PEEP levels from 10 up to 14 cmH2O were observed across thresholds compared to baseline PEEP of 10 cmH2O. A threshold of approximately 5% cumulative collapse yields the optimum compromise between all clinical and mechanical outcomes. EIT-guided PEEP titration by the RPF approach is feasible and is linked to improved overall lung mechanics) during SMV using a threshold of approximately 5% CL. However, the long-term clinical safety and effect of this approach remain to be determined.


  • Open Access

    Regional peak flow as a novel approach to assess regional pulmonary mechanics by electrical impedance tomography: an observational validation study

    by Sebastiaan A. M. de Jongh, Serge J. H. Heines, Frans H. C. de Jongh, Ruud P. J. Segers, Iwan C. C. van der Horst, Bas C. T. van Bussel, Dennis C. J. J. Bergmans

    Original Article Regional peak flow as a novel approach to assess regional pulmonary mechanics by electrical impedance tomography: an observational validation study Sebastiaan A. M. de Jongh, Serge J. H. Heines, Frans H. C. de Jongh, Ruud P. J. Segers, Iwan C. C. van der Horst, Bas C. T. van Bussel, Dennis C. J. J. Bergmans


  • Open Access

    The global inhomogeneity index assessed by electrical impedance tomography overestimates PEEP requirement in patients with ARDS: an observational study

    by Serge J. H. Heines, Sebastiaan A. M. de Jongh, Ulrich Strauch, Iwan C. C. van der Horst, Marcel C. G. van de Poll, Dennis C. J. J. Bergmans

    Background: Electrical impedance tomography (EIT) visualises alveolar overdistension and alveolar collapse and enables optimisation of ventilator settings by using the best balance between alveolar overdistension and collapse (ODCL). Besides, the global inhomogeneity index (GI), measured by EIT, may also be of added value in determining PEEP. Optimal PEEP is often determined based on the best dynamic compliance without EIT at the bedside. This study aimed to assess the effect of a PEEP trial on ODCL, GI and dynamic compliance in patients with and without ARDS. Secondly, PEEP levels from “optimal PEEP” approaches by ODCL, GI and dynamic compliance are compared. Methods: In 2015–2016, we included patients with ARDS using postoperative cardiothoracic surgery patients as a reference group. A PEEP trial was performed with four consecutive incremental followed by four decremental PEEP steps of 2 cmH2O. Primary outcomes at each step were GI, ODCL and best dynamic compliance. In addition, the agreement between ODCL, GI, and dynamic compliance was determined for the individual patient. Results: Twenty-eight ARDS and 17 postoperative cardiothoracic surgery patients were included. The mean optimal PEEP, according to best compliance, was 10.3 (±2.9) cmH2O in ARDS compared to 9.8 (±2.5) cmH2O in cardiothoracic surgery patients. Optimal PEEP according to ODCL was 10.9 (±2.5) in ARDS and 9.6 (±1.6) in cardiothoracic surgery patients. Optimal PEEP according to GI was 17.1 (±3.9) in ARDS compared to 14.2 (±3.4) in cardiothoracic surgery patients. Conclusions: Currently, no golden standard to titrate PEEP is available. We showed that when using the GI, PEEP requirements are higher compared to ODCL and best dynamic compliance during a PEEP trial in patients with and without ARDS.