The global inhomogeneity index assessed by electrical impedance tomography overestimates PEEP requirement in patients with ARDS: an observational study
Open Access
- 15 August 2022
- journal article
- research article
- Published by Springer Nature in BMC Anesthesiology
- Vol. 22 (1) , 1-12
Abstract
Background: Electrical impedance tomography (EIT) visualises alveolar overdistension and alveolar collapse and enables optimisation of ventilator settings by using the best balance between alveolar overdistension and collapse (ODCL). Besides, the global inhomogeneity index (GI), measured by EIT, may also be of added value in determining PEEP. Optimal PEEP is often determined based on the best dynamic compliance without EIT at the bedside. This study aimed to assess the effect of a PEEP trial on ODCL, GI and dynamic compliance in patients with and without ARDS. Secondly, PEEP levels from “optimal PEEP” approaches by ODCL, GI and dynamic compliance are compared. Methods: In 2015–2016, we included patients with ARDS using postoperative cardiothoracic surgery patients as a reference group. A PEEP trial was performed with four consecutive incremental followed by four decremental PEEP steps of 2 cmH2O. Primary outcomes at each step were GI, ODCL and best dynamic compliance. In addition, the agreement between ODCL, GI, and dynamic compliance was determined for the individual patient. Results: Twenty-eight ARDS and 17 postoperative cardiothoracic surgery patients were included. The mean optimal PEEP, according to best compliance, was 10.3 (±2.9) cmH2O in ARDS compared to 9.8 (±2.5) cmH2O in cardiothoracic surgery patients. Optimal PEEP according to ODCL was 10.9 (±2.5) in ARDS and 9.6 (±1.6) in cardiothoracic surgery patients. Optimal PEEP according to GI was 17.1 (±3.9) in ARDS compared to 14.2 (±3.4) in cardiothoracic surgery patients. Conclusions: Currently, no golden standard to titrate PEEP is available. We showed that when using the GI, PEEP requirements are higher compared to ODCL and best dynamic compliance during a PEEP trial in patients with and without ARDS.Keywords
This publication has 41 references indexed in Scilit:
- Effect of PEEP and Tidal Volume on Ventilation Distribution and End-Expiratory Lung Volume: A Prospective Experimental Animal and Pilot Clinical StudyPLOS ONE, 2013
- Individualized PEEP Setting in Subjects With ARDS: A Randomized Controlled Pilot StudyRespiratory Care, 2013
- Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trialCritical Care, 2011
- Effect of PEEP on regional ventilation during laparoscopic surgery monitored by electrical impedance tomographyActa Anaesthesiologica Scandinavica, 2011
- Regional tidal ventilation and compliance during a stepwise vital capacity manoeuvreIntensive Care Medicine, 2010
- PEEP titration guided by ventilation homogeneity: a feasibility study using electrical impedance tomographyCritical Care, 2010
- Ventilation inhomogeneity is one criterion among many in multidimensional PEEP titrationCritical Care, 2010
- Can heterogeneity in ventilation be good?Critical Care, 2010
- Use of dynamic compliance for open lung positive end-expiratory pressure titration in an experimental studyCritical Care Medicine, 2007
- Ventilation with Lower Tidal Volumes as Compared with Traditional Tidal Volumes for Acute Lung Injury and the Acute Respiratory Distress SyndromeThe New England journal of medicine, 2000