Florian Soyka
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Florian Soyka has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Heinrich Bülthoff
Max Planck Institute for Biological Cybernetics, Tübingen, Germany
8 shared publications Carsten Alteköster
Institute for Occupational Safety and Health of the German Social Accident Insurance Sankt Augustin Germany
4 shared publicationsMichael Barnett-Cowan
Max Planck Institute for Biological Cybernetics, Department: Human Perception, Cognition and Action, Tübingen, Germany
3 shared publicationsPaolo Robuffo Giordano
Department of Human Perception, Cognition and Action, Max Planck Institute for Biological Cybernetics, Tübingen, Germany
3 shared publications- Wout Joseph
Ghent University/IMEC
3 shared publications - Akimasa Hirata
Nagoya Institute of Technology
2 shared publications
Latest Publications
- 21 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (18) , 185003
Evaluation of neuronal activation thresholds for low-frequency electromagnetic exposure using morphologically realistic neuron models
Objective. International guidelines for low-frequency electromagnetic field exposure (LF EMF) are primarily intended to prevent substantiated adverse effects. In these frameworks, limits on internal electric fields are linked to external exposure levels through computational dosimetry. However, the relationship between internal electric fields and these adverse effects remains incompletely understood. In particular, current approaches often overlook the morphological complexity and diversity of cortical neurons, which may limit the realism of neuronal activation estimates used to support these assessments. This study aimed to evaluate LF EMF-induced neural activation using morphologically realistic neuron models representing all cortical layers. Approach. Twenty-five morphologically realistic neuron models were embedded within 11 detailed human head models. The internal electric fields were simulated for uniform magnetic field exposures (100 Hz–100 kHz) along the three anatomical directions, and excitation thresholds were computed using a multi-scale framework combining voxel-based dosimetry with biophysical neuron simulations. A real-world exposure scenario involving a child near an acousto-magnetic article-surveillance deactivator was also analyzed. Main results. Excitation thresholds varied across cell type, morphology, cortical location, subject anatomy, frequency, and exposure direction, with L2/3 pyramidal, L4 basket, and L5 thick-tufted pyramidal cells showing the lowest thresholds. Despite this variability, all simulated thresholds were conservative with respect to the basic restrictions and dosimetric reference limits set by IEEE International Committee on Electromagnetic Safety and International Commission on Non-Ionizing Radiation Protection. The smallest margin occurred at 100 kHz, where the threshold remained a factor of 2.8 above the corresponding limit. Significance. These findings indicate that current LF EMF exposure limits remain conservative when evaluated using highly detailed, morphology-based central nervous system activation models.
- 21 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (18) , 185003
Evaluation of neuronal activation thresholds for low-frequency electromagnetic exposure using morphologically realistic neuron models
Objective. International guidelines for low-frequency electromagnetic field exposure (LF EMF) are primarily intended to prevent substantiated adverse effects. In these frameworks, limits on internal electric fields are linked to external exposure levels through computational dosimetry. However, the relationship between internal electric fields and these adverse effects remains incompletely understood. In particular, current approaches often overlook the morphological complexity and diversity of cortical neurons, which may limit the realism of neuronal activation estimates used to support these assessments. This study aimed to evaluate LF EMF-induced neural activation using morphologically realistic neuron models representing all cortical layers. Approach. Twenty-five morphologically realistic neuron models were embedded within 11 detailed human head models. The internal electric fields were simulated for uniform magnetic field exposures (100 Hz–100 kHz) along the three anatomical directions, and excitation thresholds were computed using a multi-scale framework combining voxel-based dosimetry with biophysical neuron simulations. A real-world exposure scenario involving a child near an acousto-magnetic article-surveillance deactivator was also analyzed. Main results. Excitation thresholds varied across cell type, morphology, cortical location, subject anatomy, frequency, and exposure direction, with L2/3 pyramidal, L4 basket, and L5 thick-tufted pyramidal cells showing the lowest thresholds. Despite this variability, all simulated thresholds were conservative with respect to the basic restrictions and dosimetric reference limits set by IEEE International Committee on Electromagnetic Safety and International Commission on Non-Ionizing Radiation Protection. The smallest margin occurred at 100 kHz, where the threshold remained a factor of 2.8 above the corresponding limit. Significance. These findings indicate that current LF EMF exposure limits remain conservative when evaluated using highly detailed, morphology-based central nervous system activation models.
- Open Access
Evaluation of Neuronal Activation Thresholds for Low-Frequency Electromagnetic Exposure Using Morphologically Realistic Neuron Models
International guidelines for low-frequency electromagnetic field exposure (LF EMF) are primarily intended to prevent substantiated adverse effects. In the frameworks, limits on internal electric fields are linked to external exposure levels through computational dosimetry. However, the relationship between internal electric fields and these adverse effects remains incompletely understood. In particular, current approaches often overlook the morphological complexity and diversity of cortical neurons, which may limit the realism of neuronal activation estimates used to support these assessments. This study evaluates LF EMF-induced neural activation using 25 morphologically realistic neuron models spanning all cortical layers, embedded within 11 detailed human head models. The internal electric fields were simulated for uniform magnetic field exposures (100 Hz–100 kHz) along the three anatomical directions, and excitation thresholds were computed using a multi-scale framework combining voxel-based dosimetry with biophysical neuron simulations. A real-world exposure scenario involving a child near an acousto-magnetic article-surveillance deactivator was also analyzed. Thresholds varied across cell type, morphology, cortical location, subject anatomy, frequency, and exposure direction, with L2/3 pyramidal, L4 basket, and L5 thick-tufted pyramidal cells showing the lowest thresholds. Despite this variability, all simulated thresholds were conservative with respect to the basic restrictions and dosimetric reference limits set by IEEE ICES and ICNIRP. The smallest margin occurred at 100 kHz, where the threshold remained a factor of 2.8 above the corresponding limit. These findings indicate that current LF EMF exposure limits remain conservative when evaluated using highly detailed, morphology-based CNS activation models.
Open AccessEvaluation of Neuronal Activation Thresholds for Low-Frequency Electromagnetic Exposure Using Morphologically Realistic Neuron Models
International guidelines for low-frequency electromagnetic field exposure (LF EMF) are primarily intended to prevent substantiated adverse effects. In the frameworks, limits on internal electric fields are linked to external exposure levels through computational dosimetry. However, the relationship between internal electric fields and these adverse effects remains incompletely understood. In particular, current approaches often overlook the morphological complexity and diversity of cortical neurons, which may limit the realism of neuronal activation estimates used to support these assessments. This study evaluates LF EMF-induced neural activation using 25 morphologically realistic neuron models spanning all cortical layers, embedded within 11 detailed human head models. The internal electric fields were simulated for uniform magnetic field exposures (100 Hz–100 kHz) along the three anatomical directions, and excitation thresholds were computed using a multi-scale framework combining voxel-based dosimetry with biophysical neuron simulations. A real-world exposure scenario involving a child near an acousto-magnetic article-surveillance deactivator was also analyzed. Thresholds varied across cell type, morphology, cortical location, subject anatomy, frequency, and exposure direction, with L2/3 pyramidal, L4 basket, and L5 thick-tufted pyramidal cells showing the lowest thresholds. Despite this variability, all simulated thresholds were conservative with respect to the basic restrictions and dosimetric reference limits set by IEEE ICES and ICNIRP. The smallest margin occurred at 100 kHz, where the threshold remained a factor of 2.8 above the corresponding limit. These findings indicate that current LF EMF exposure limits remain conservative when evaluated using highly detailed, morphology-based CNS activation models.
- Open Access
- 26 March 2026
- Published by Wiley in Bioelectromagnetics
- Vol. 47 (3) , e70051
Why Low‐Frequency EMF Safety Would Benefit From Peak‐Based Limits Instead of RMS Values
Current low‐frequency EMF exposure limits are based on RMS values. However, the hazard at low frequencies, neural and muscular stimulation is driven by instantaneous peak values. Because action potentials follow an all‐or‐nothing threshold, even a single suprathreshold cycle can trigger excitation, whereas long‐term RMS averages can be arbitrarily reduced by inserting pauses into signals. Pulsed or bursty fields—such as those emitted by certain deactivators used in electronic article surveillance—may comply with RMS‐based limits despite containing peaks capable of exceeding physiological thresholds. Reformulating both basic restrictions and reference levels in terms of peak values would align exposure limits with neurophysiological mechanisms and provide clearer guidance for ensuring safety. As ICNIRP revises its 2010 low‐frequency guidelines, this is an opportune moment to adopt peak‐based limits and better protect workers and the general public.
- 26 March 2026
- Published by Wiley in Bioelectromagnetics
- Vol. 47 (3) , e70051
Open AccessWhy Low‐Frequency EMF Safety Would Benefit From Peak‐Based Limits Instead of RMS Values
Current low‐frequency EMF exposure limits are based on RMS values. However, the hazard at low frequencies, neural and muscular stimulation is driven by instantaneous peak values. Because action potentials follow an all‐or‐nothing threshold, even a single suprathreshold cycle can trigger excitation, whereas long‐term RMS averages can be arbitrarily reduced by inserting pauses into signals. Pulsed or bursty fields—such as those emitted by certain deactivators used in electronic article surveillance—may comply with RMS‐based limits despite containing peaks capable of exceeding physiological thresholds. Reformulating both basic restrictions and reference levels in terms of peak values would align exposure limits with neurophysiological mechanisms and provide clearer guidance for ensuring safety. As ICNIRP revises its 2010 low‐frequency guidelines, this is an opportune moment to adopt peak‐based limits and better protect workers and the general public.
- Open Access
- 14 February 2025
- Published by Frontiers Media SA in Frontiers in Virtual Reality
- Vol. 6, 1528804
Editorial: Use of AR/MR/VR in the context of occupational safety and health
One of the most significant advantages of XR in OSH is the opportunity to create close-toreality, controllable training environments. VR, for instance, allows employees to experience hazardous situations without real-world risks. One example is the mixed reality simulator for mobile elevating work platforms designed by Gasparello et al. which allows to train operators by confronting them with very risky situations while at the same time avoiding any real danger as a measure for accident prevention. Whether the application of high-risk environment is construction, manufacturing, chemical handling or different, VR simulation of potentially dangerous scenarios allows workers to safely practice safety procedures and emergency responses. For example, Ismael et al. created an AR system known as "SMARTLab" for safety training in hazardous material science laboratories to improve OSH and productivity. Hands-on, immersive experience has the potential to pave the way for better retention of safety protocols as compared to training methods like reading manuals or front-of-class teaching. Despite this, trainees may repeatedly engage in simulations until they master the necessary skills, ensuring they are well-prepared to prevent from real-life hazards.In addition to training, XR technologies enhance hazard identification and risk assessment. Augmented reality, which overlays digital information onto the physical world, can assist workers in identifying hazards in real time. For instance, Feder et al. assessed wearable displays for firefighters using VR with laypersons. Their findings indicate that users find the approach useful and that they would consider using such a system. Such AR technology could also be used to display safety guidelines, highlight dangerous areas, or provide warnings about equipment that requires maintenance. For example, Soyka and Simons (2022) used AR to display magnetic field measurements together with exposure evaluation data and necessary safety distances to facilitate risk assessment. Using a proactive approach can help workers to remain vigilant about potential risks, improving overall system safety. Moreover, AR-based tools could be especially designed to support supervisors in conducting more thorough inspections, identifying risks that might otherwise be overlooked.Another crucial application of XR is in emergency preparedness and response. Workers can be trained through VR simulation scenarios to better handle emergencies, such as fires, equipment malfunctions, or chemical spills. These simulations can mimic real-world conditions, providing workers with the experience of making critical decisions under pressure. This preparedness not only enhances worker confidence but can also reduce response times and minimize the severity of accidents when emergencies occur if interfaces for human-system interaction are designed according to human factors and ergonomics requirements. Additionally, XR applications allow for detailed post-incident analysis, helping organizations refine human-machine interface design, safety protocols and training programs based on simulated outcomes.XR also improves the accessibility of safety training. Workers from different geographic locations can participate in virtual safety workshops and training sessions without the need to be physically present at a training site. This reduces logistical challenges and makes it easier for organizations to provide consistent, high-quality safety training across all of their locations. Furthermore, adaptability of XR may also refer to that training programs can be tailored to individual workers' needs, ensuring that every employee receives the most relevant training for their specific job roles and risks.The concept of the digital twin can also be seen as a MR application. A digital twin is a virtual model or digital replica of a physical object, system, or process, created using real-time data and advanced simulations. It mirrors the characteristics, functions, and performance of its real-world counterpart, allowing for analysis, monitoring, and optimization without directly interacting with the physical entity. Digital twins are commonly used in industries like manufacturing, healthcare, and smart cities to improve efficiency, predict failures, and optimize operations by providing insights based on simulated real-time data and predictive modelling. This concept enables more informed decision-making and enhances the ability to respond to changes dynamically. Casey et al. aimed at reducing the risk of material damage as well as improving OSH by creating a real-time digital twin for active safety in an aircraft hangar. They implemented an active safety system that uses the digital twin to perform realtime path planning, collision prediction, and safety alerts for tow truck drivers and hangar personnel.An evaluation of XR technology including ecological validity of XR simulations is crucial for its effectiveness and real-world applicability. Technology evaluation helps assess whether XR tools meet the intended functional goals and usability requirements for human-system interaction, while ensuring tools function reliably and efficiently within specified contexts. Therefore, De Souza and Tartz investigated visual perception, visual quality, and user experience in video see-through head-mounted displays. Ecological validity, in addition, refers to how well XR simulations replicate real-world environments and user experiences, making them more empathetic for practical use. Without ecological validity, user experiences of XR may remain artificial or disconnected from real-world scenarios, which can limit their utility for design improvements and training. Personeni and Savescu conducted a systematic review assessing ecological validity of VR simulations in workstation health and safety assessment. Together, thorough technology evaluation and ecological validity ensure that XR simulations are both technically...
- 14 February 2025
- Published by Frontiers Media SA in Frontiers in Virtual Reality
- Vol. 6, 1528804
Open AccessEditorial: Use of AR/MR/VR in the context of occupational safety and health
One of the most significant advantages of XR in OSH is the opportunity to create close-toreality, controllable training environments. VR, for instance, allows employees to experience hazardous situations without real-world risks. One example is the mixed reality simulator for mobile elevating work platforms designed by Gasparello et al. which allows to train operators by confronting them with very risky situations while at the same time avoiding any real danger as a measure for accident prevention. Whether the application of high-risk environment is construction, manufacturing, chemical handling or different, VR simulation of potentially dangerous scenarios allows workers to safely practice safety procedures and emergency responses. For example, Ismael et al. created an AR system known as "SMARTLab" for safety training in hazardous material science laboratories to improve OSH and productivity. Hands-on, immersive experience has the potential to pave the way for better retention of safety protocols as compared to training methods like reading manuals or front-of-class teaching. Despite this, trainees may repeatedly engage in simulations until they master the necessary skills, ensuring they are well-prepared to prevent from real-life hazards.In addition to training, XR technologies enhance hazard identification and risk assessment. Augmented reality, which overlays digital information onto the physical world, can assist workers in identifying hazards in real time. For instance, Feder et al. assessed wearable displays for firefighters using VR with laypersons. Their findings indicate that users find the approach useful and that they would consider using such a system. Such AR technology could also be used to display safety guidelines, highlight dangerous areas, or provide warnings about equipment that requires maintenance. For example, Soyka and Simons (2022) used AR to display magnetic field measurements together with exposure evaluation data and necessary safety distances to facilitate risk assessment. Using a proactive approach can help workers to remain vigilant about potential risks, improving overall system safety. Moreover, AR-based tools could be especially designed to support supervisors in conducting more thorough inspections, identifying risks that might otherwise be overlooked.Another crucial application of XR is in emergency preparedness and response. Workers can be trained through VR simulation scenarios to better handle emergencies, such as fires, equipment malfunctions, or chemical spills. These simulations can mimic real-world conditions, providing workers with the experience of making critical decisions under pressure. This preparedness not only enhances worker confidence but can also reduce response times and minimize the severity of accidents when emergencies occur if interfaces for human-system interaction are designed according to human factors and ergonomics requirements. Additionally, XR applications allow for detailed post-incident analysis, helping organizations refine human-machine interface design, safety protocols and training programs based on simulated outcomes.XR also improves the accessibility of safety training. Workers from different geographic locations can participate in virtual safety workshops and training sessions without the need to be physically present at a training site. This reduces logistical challenges and makes it easier for organizations to provide consistent, high-quality safety training across all of their locations. Furthermore, adaptability of XR may also refer to that training programs can be tailored to individual workers' needs, ensuring that every employee receives the most relevant training for their specific job roles and risks.The concept of the digital twin can also be seen as a MR application. A digital twin is a virtual model or digital replica of a physical object, system, or process, created using real-time data and advanced simulations. It mirrors the characteristics, functions, and performance of its real-world counterpart, allowing for analysis, monitoring, and optimization without directly interacting with the physical entity. Digital twins are commonly used in industries like manufacturing, healthcare, and smart cities to improve efficiency, predict failures, and optimize operations by providing insights based on simulated real-time data and predictive modelling. This concept enables more informed decision-making and enhances the ability to respond to changes dynamically. Casey et al. aimed at reducing the risk of material damage as well as improving OSH by creating a real-time digital twin for active safety in an aircraft hangar. They implemented an active safety system that uses the digital twin to perform realtime path planning, collision prediction, and safety alerts for tow truck drivers and hangar personnel.An evaluation of XR technology including ecological validity of XR simulations is crucial for its effectiveness and real-world applicability. Technology evaluation helps assess whether XR tools meet the intended functional goals and usability requirements for human-system interaction, while ensuring tools function reliably and efficiently within specified contexts. Therefore, De Souza and Tartz investigated visual perception, visual quality, and user experience in video see-through head-mounted displays. Ecological validity, in addition, refers to how well XR simulations replicate real-world environments and user experiences, making them more empathetic for practical use. Without ecological validity, user experiences of XR may remain artificial or disconnected from real-world scenarios, which can limit their utility for design improvements and training. Personeni and Savescu conducted a systematic review assessing ecological validity of VR simulations in workstation health and safety assessment. Together, thorough technology evaluation and ecological validity ensure that XR simulations are both technically...
- Open Access
- 3 November 2024
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (1)
Action potential threshold variability for different electrostimulation models and its potential impact on occupational exposure limit values
Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. Important parameters of these models are the membrane channel dynamics describing the ionic transmembrane currents as well as the temperature at which the models operate. This work compares action potential thresholds for five different membrane channel dynamics used with the SENN model. Furthermore, two more detailed double‐cable models by Gaines et al. (MRG‐Sensory and MRG‐Motor) are also considered in this work. Thresholds calculated with the SENN model and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures at 22°C and 37°C. Results show that MRG thresholds are lower than SENN thresholds. Deriving alternative ELVs from these thresholds shows that the alternative ELVs can change significantly with different ion channel dynamics (up to a factor of 22). Using the double cable model could lead to approximately ten times lower alternative exposure limit values. On the contrary, using the SENN model with different membrane channel dynamics could also lead to higher alternative exposure limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs.
- 3 November 2024
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (1)
Open AccessAction potential threshold variability for different electrostimulation models and its potential impact on occupational exposure limit values
Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. Important parameters of these models are the membrane channel dynamics describing the ionic transmembrane currents as well as the temperature at which the models operate. This work compares action potential thresholds for five different membrane channel dynamics used with the SENN model. Furthermore, two more detailed double‐cable models by Gaines et al. (MRG‐Sensory and MRG‐Motor) are also considered in this work. Thresholds calculated with the SENN model and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures at 22°C and 37°C. Results show that MRG thresholds are lower than SENN thresholds. Deriving alternative ELVs from these thresholds shows that the alternative ELVs can change significantly with different ion channel dynamics (up to a factor of 22). Using the double cable model could lead to approximately ten times lower alternative exposure limit values. On the contrary, using the SENN model with different membrane channel dynamics could also lead to higher alternative exposure limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs.
- Open Access
Action Potential Threshold Variability for Different Electrostimulation Models and the Impact on Occupational Exposure Limit Values
Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. An important part of these models are the membrane channel dynamics describing the ionic transmembrane currents. This work shows how ELVs change significantly with different ion channel dynamics (up to a factor of 22). Furthermore, two more detailed double-cable models by Gaines et al. (MRG-Sensory and MRG-Motor) are also considered in this work. Thresholds calculated with the SENN model (with Frankenhaeuser-Huxley membrane channel dynamics) and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures between 22 °C and 37 °C. Results show that MRG thresholds are lower than SENN thresholds. In the context of occupational ELVs, using the double cable model would lead to approximately ten times lower limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs. Highlights Different membrane channel dynamics change derived exposure limit values by more than one order of magnitude. Double-cable models result in a reduction of derived exposure limit values by one order of magnitude. Lower temperatures reduce the action potential thresholds at frequencies below 300 Hz.
Open AccessAction Potential Threshold Variability for Different Electrostimulation Models and the Impact on Occupational Exposure Limit Values
Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. An important part of these models are the membrane channel dynamics describing the ionic transmembrane currents. This work shows how ELVs change significantly with different ion channel dynamics (up to a factor of 22). Furthermore, two more detailed double-cable models by Gaines et al. (MRG-Sensory and MRG-Motor) are also considered in this work. Thresholds calculated with the SENN model (with Frankenhaeuser-Huxley membrane channel dynamics) and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures between 22 °C and 37 °C. Results show that MRG thresholds are lower than SENN thresholds. In the context of occupational ELVs, using the double cable model would lead to approximately ten times lower limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs. Highlights Different membrane channel dynamics change derived exposure limit values by more than one order of magnitude. Double-cable models result in a reduction of derived exposure limit values by one order of magnitude. Lower temperatures reduce the action potential thresholds at frequencies below 300 Hz.
- Open Access
- 24 August 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (17) , 10564
Improving the Understanding of Low Frequency Magnetic Field Exposure with Augmented Reality
Low frequency magnetic fields are often present in our everyday life due to the multitude of electronic devices. High magnetic fields can occur in the workplace from a wide variety of machines and systems, which must be measured and evaluated from the point of view of occupational safety. To facilitate the understanding of magnetic fields by supervisors and employees in the workplace, an augmented reality (AR) application was developed to visualize the measured flux densities and the resulting safety distances. The application was deployed on two smartphones, allowing for the simultaneous viewing of the same scene without the use of additional markers. Whether the application creates a better understanding of the exposure situation was evaluated with the help of an online survey. In this survey, participants received either a classic measurement report or a report enhanced by augmented images. The evaluation shows that it subjectively felt less difficult for participants with the augmented report to answer questions about the exposure situation. Furthermore, they also objectively performed better in answering the questions than did the group with the classic report. Therefore, this work shows that AR enhanced images can improve the understanding of an exposure situation, and it describes how such images and videos can be created.
- 24 August 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (17) , 10564
Open AccessImproving the Understanding of Low Frequency Magnetic Field Exposure with Augmented Reality
Low frequency magnetic fields are often present in our everyday life due to the multitude of electronic devices. High magnetic fields can occur in the workplace from a wide variety of machines and systems, which must be measured and evaluated from the point of view of occupational safety. To facilitate the understanding of magnetic fields by supervisors and employees in the workplace, an augmented reality (AR) application was developed to visualize the measured flux densities and the resulting safety distances. The application was deployed on two smartphones, allowing for the simultaneous viewing of the same scene without the use of additional markers. Whether the application creates a better understanding of the exposure situation was evaluated with the help of an online survey. In this survey, participants received either a classic measurement report or a report enhanced by augmented images. The evaluation shows that it subjectively felt less difficult for participants with the augmented report to answer questions about the exposure situation. Furthermore, they also objectively performed better in answering the questions than did the group with the classic report. Therefore, this work shows that AR enhanced images can improve the understanding of an exposure situation, and it describes how such images and videos can be created.
- Open Access
- 2 June 2022
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 10, 875946
Protection of Workers Exposed to Radiofrequency Electromagnetic Fields: A Perspective on Open Questions in the Context of the New ICNIRP 2020 Guidelines
Workers in occupational settings are usually exposed to numerous sources of electromagnetic fields (EMF) and to different physical agents. Risk assessment for industrial workplaces concerning EMF is not only relevant to operators of devices or machinery emitting EMF, but also to support-workers, bystanders, service and maintenance personnel, and even visitors. Radiofrequency EMF guidelines published in 2020 by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) may also be indirectly applied to assess risks emerging from EMF sources at workplaces by technical standards or legislation. To review the applicability and adequacy to assess exposure to EMF in occupational settings in the European Union, the most current ICNIRP guidelines on radiofrequency EMF are reviewed. Relevant ICNIRP fundamentals and principles are introduced, followed by practical aspects of exposure assessment. To conclude, open questions are formulated pointing out gaps between the guidelines' principles and occupational practice, such as the impact of hot and humid environments and physical activity or controversies around ICNIRPS's reduction factors in view of assessment uncertainty in general. Thus, the article aims to provide scientific policy advisors, labor inspectors, or experts developing standards with a profound understanding about ICNIRP guidelines' applicability to assess hazards related to radiofrequency EMF in occupational settings.
- 2 June 2022
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 10, 875946
Open AccessProtection of Workers Exposed to Radiofrequency Electromagnetic Fields: A Perspective on Open Questions in the Context of the New ICNIRP 2020 Guidelines
Workers in occupational settings are usually exposed to numerous sources of electromagnetic fields (EMF) and to different physical agents. Risk assessment for industrial workplaces concerning EMF is not only relevant to operators of devices or machinery emitting EMF, but also to support-workers, bystanders, service and maintenance personnel, and even visitors. Radiofrequency EMF guidelines published in 2020 by the International Commission on Non-Ionizing Radiation Protection (ICNIRP) may also be indirectly applied to assess risks emerging from EMF sources at workplaces by technical standards or legislation. To review the applicability and adequacy to assess exposure to EMF in occupational settings in the European Union, the most current ICNIRP guidelines on radiofrequency EMF are reviewed. Relevant ICNIRP fundamentals and principles are introduced, followed by practical aspects of exposure assessment. To conclude, open questions are formulated pointing out gaps between the guidelines' principles and occupational practice, such as the impact of hot and humid environments and physical activity or controversies around ICNIRPS's reduction factors in view of assessment uncertainty in general. Thus, the article aims to provide scientific policy advisors, labor inspectors, or experts developing standards with a profound understanding about ICNIRP guidelines' applicability to assess hazards related to radiofrequency EMF in occupational settings.
- 28 February 2020
- Published by Erich Schmidt Verlag GmbH & Co. KG in sicher ist sicher
- No. 3
Bewertungsverfahren für gepulste magnetische Felder im Vergleich (Teil 2 von 2)
- 28 February 2020
- Published by Erich Schmidt Verlag GmbH & Co. KG in sicher ist sicher
- No. 3
Bewertungsverfahren für gepulste magnetische Felder im Vergleich (Teil 2 von 2)
- Open Access
- 14 February 2020
- Published by Springer Nature in Experimental Brain Research
- Vol. 238 (3) , 699-711
The role of acceleration and jerk in perception of above-threshold surge motion
Inertial motions may be defined in terms of acceleration and jerk, the time-derivative of acceleration. We investigated the relative contributions of these characteristics to the perceived intensity of motions. Participants were seated on a high-fidelity motion platform, and presented with 25 above-threshold 1 s forward (surge) motions that had acceleration values ranging between 0.5 and 2.5 $$\text {m/s}^2$$ and jerks between 20 and 60 $$\text {m/s}^3$$ , in five steps each. Participants performed two tasks: a magnitude estimation task, where they provided subjective ratings of motion intensity for each motion, and a two-interval forced choice task, where they provided judgments on which motion of a pair was more intense, for all possible combinations of the above motion profiles. Analysis of the data shows that responses on both tasks may be explained by a single model, and that this model should include acceleration only. The finding that perceived motion intensity depends on acceleration only appears inconsistent with previous findings. We show that this discrepancy can be explained by considering the frequency content of the motions, and demonstrate that a linear time-invariant systems model of the otoliths and subsequent processing can account for the present data as well as for previous findings.- 14 February 2020
- Published by Springer Nature in Experimental Brain Research
- Vol. 238 (3) , 699-711
Open AccessThe role of acceleration and jerk in perception of above-threshold surge motion
Inertial motions may be defined in terms of acceleration and jerk, the time-derivative of acceleration. We investigated the relative contributions of these characteristics to the perceived intensity of motions. Participants were seated on a high-fidelity motion platform, and presented with 25 above-threshold 1 s forward (surge) motions that had acceleration values ranging between 0.5 and 2.5 $$\text {m/s}^2$$ and jerks between 20 and 60 $$\text {m/s}^3$$ , in five steps each. Participants performed two tasks: a magnitude estimation task, where they provided subjective ratings of motion intensity for each motion, and a two-interval forced choice task, where they provided judgments on which motion of a pair was more intense, for all possible combinations of the above motion profiles. Analysis of the data shows that responses on both tasks may be explained by a single model, and that this model should include acceleration only. The finding that perceived motion intensity depends on acceleration only appears inconsistent with previous findings. We show that this discrepancy can be explained by considering the frequency content of the motions, and demonstrate that a linear time-invariant systems model of the otoliths and subsequent processing can account for the present data as well as for previous findings.