Action potential threshold variability for different electrostimulation models and its potential impact on occupational exposure limit values
Open Access
- 3 November 2024
- journal article
- research article
- Published by Wiley in Bioelectromagnetics
- Vol. 46 (1)
Abstract
Occupational exposure limit values (ELVs) for body internal electric fields can be derived from thresholds for action potential generation. These thresholds can be calculated with electrostimulation models. The spatially extended nonlinear node model (SENN) is often used to determine such thresholds. Important parameters of these models are the membrane channel dynamics describing the ionic transmembrane currents as well as the temperature at which the models operate. This work compares action potential thresholds for five different membrane channel dynamics used with the SENN model. Furthermore, two more detailed double‐cable models by Gaines et al. (MRG‐Sensory and MRG‐Motor) are also considered in this work. Thresholds calculated with the SENN model and the MRG models are compared for frequencies between 1 Hz and 100 kHz and temperatures at 22°C and 37°C. Results show that MRG thresholds are lower than SENN thresholds. Deriving alternative ELVs from these thresholds shows that the alternative ELVs can change significantly with different ion channel dynamics (up to a factor of 22). Using the double cable model could lead to approximately ten times lower alternative exposure limit values. On the contrary, using the SENN model with different membrane channel dynamics could also lead to higher alternative exposure limit values. Therefore, future exposure guidelines should take the influence of different electrostimulation models into account when deriving ELVs.Keywords
All Related Versions
Funding Information
- Fonds Wetenschappelijk Onderzoek (1230222N)
This publication has 25 references indexed in Scilit:
- A model of motor and sensory axon activation in the median nerve using surface electrical stimulationJournal of Computational Neuroscience, 2018
- Dependence of excitability indices on membrane channel dynamics, myelin impedance, electrode location and stimulus waveforms in myelinated and unmyelinated fibre modelsMedical & Biological Engineering & Computing, 2018
- Predicting Magnetostimulation Thresholds in the Peripheral Nervous System using Realistic Body ModelsScientific Reports, 2017
- Survey of numerical electrostimulation modelsPhysics in Medicine & Biology, 2016
- Strength–duration relationship for intra- versus extracellular stimulation with microelectrodesNeuroscience, 2012
- Evaluation of a model of the cochlear neural membrane. I. Physiological measurement of membrane characteristics in response to intrameatal electrical stimulationHearing Research, 2000
- Evaluation of a model of the cochlear neural membrane. II: Comparison of model and physiological measures of membrane properties measured in response to intrameatal electrical stimulationHearing Research, 2000
- Applied Bioelectricity1998
- Action potentials and membrane currents in the human node of RanvierPflügers Archiv - European Journal of Physiology, 1995
- Na currents and action potentials in rat myelinated nerve fibres at 20 and 37° CPflügers Archiv - European Journal of Physiology, 1987