Tommi E. Tiihonen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tommi E. Tiihonen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Vesa-Pekka Lehto
Department of Technical Physics, University of Eastern Finland, Kuopio, Finland
4 shared publications - Joakim Riikonen
Department of Technical Physics, University of Eastern Finland , Kuopio
2 shared publications - Petri A. Turhanen
University of Eastern Finland, School of Pharmacy, Biocenter Kuopio, P.O. Box 1627, FIN-70211, Kuopio, Finland
2 shared publications Alireza Rahmani
1 shared publication- Behnam Chameh1 shared publication
- Jarkko Akkanen
Department of Environmental and Biological Sciences, University of Eastern Finland, Joensuu, Finland
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
Toward field‑deployable sediment porewater extraction: A comparative study for environmental trace metal monitoring
Sediment porewater is a key medium for controlling contaminant mobility and bioavailability in aquatic systems. Yet, methodologies to extract porewater from sediment samples differ substantially in their efficiency, reliability, and suitability for field deployment. The present study compared four porewater extraction techniques: Laboratory centrifugation, portable centrifugation, Rhizon samplers, and a novel AeroPress-based extraction device, utilizing silty and sandy sediments from two boreal lakes. Extraction efficiency, sample contamination risks, and operational feasibility for field use were evaluated. Laboratory and portable centrifugation produced the highest porewater recoveries, generally exceeding 25%–50% extraction efficiency, whereas AeroPress and Rhizon samplers yielded lower recoveries. The metal concentrations in the extracted pore water samples varied between the extraction methods and sediment types, with Rhizon samplers and AeroPress yielding higher concentrations of specific trace metals in some cases due to leaching of the metals from the components of the extraction devices, causing sample contamination. No consistent relationship was observed between extraction efficiency and metal concentrations in the extracted water samples. However, Pb showed a strong positive correlation with extraction efficiency, suggesting preferential recovery with higher-volume methods. Portable centrifugation provided the most practical balance between efficiency and field applicability based on both the volume of porewater that can be extracted and ease of use, while AeroPress offers a promising low-energy alternative in power-limited settings. These findings highlight that the porewater extraction method, the filter material, and sediment type affect the metal concentrations in the extracted porewater samples and should be carefully considered when applied for environmental monitoring.
- 23 October 2026
- Published by Oxford University Press (OUP) in Environmental Toxicology and Chemistry
Open AccessToward field‑deployable sediment porewater extraction: A comparative study for environmental trace metal monitoring
Sediment porewater is a key medium for controlling contaminant mobility and bioavailability in aquatic systems. Yet, methodologies to extract porewater from sediment samples differ substantially in their efficiency, reliability, and suitability for field deployment. The present study compared four porewater extraction techniques: Laboratory centrifugation, portable centrifugation, Rhizon samplers, and a novel AeroPress-based extraction device, utilizing silty and sandy sediments from two boreal lakes. Extraction efficiency, sample contamination risks, and operational feasibility for field use were evaluated. Laboratory and portable centrifugation produced the highest porewater recoveries, generally exceeding 25%–50% extraction efficiency, whereas AeroPress and Rhizon samplers yielded lower recoveries. The metal concentrations in the extracted pore water samples varied between the extraction methods and sediment types, with Rhizon samplers and AeroPress yielding higher concentrations of specific trace metals in some cases due to leaching of the metals from the components of the extraction devices, causing sample contamination. No consistent relationship was observed between extraction efficiency and metal concentrations in the extracted water samples. However, Pb showed a strong positive correlation with extraction efficiency, suggesting preferential recovery with higher-volume methods. Portable centrifugation provided the most practical balance between efficiency and field applicability based on both the volume of porewater that can be extracted and ease of use, while AeroPress offers a promising low-energy alternative in power-limited settings. These findings highlight that the porewater extraction method, the filter material, and sediment type affect the metal concentrations in the extracted porewater samples and should be carefully considered when applied for environmental monitoring.
- Open Access
- 15 October 2026
- Published by Elsevier in Electrochimica Acta
- Vol. 582
From barley husk to porous silicon anodes: A bio-based route to lithium-ion batteries
- 15 October 2026
- Published by Elsevier in Electrochimica Acta
- Vol. 582
Open AccessFrom barley husk to porous silicon anodes: A bio-based route to lithium-ion batteries
- Open Access
- 3 November 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (46) , 17020-17027
Simple and User-Friendly Methodology for Crystal Water Determination by Quantitative Proton NMR Spectroscopy in Deuterium Oxide
In drug research and development, knowledge of the precise structure of an active ingredient is crucial. However, it is equally important to know the water content of the drug molecule, particularly the number of crystal waters present in its structure. Such knowledge ensures the avoidance of drug dosage and formulation errors since the number of water molecules affects the physicochemical and pharmaceutical properties of the molecule. Several methods have been used for crystal water measurements of organic compounds, of which thermogravimetry and crystallography may be the most common ones. To the best of our knowledge, solution-state NMR spectroscopy has not been used for crystal water determination in deuterium oxide. Quantitative NMR (qNMR) method will be presented in the paper with a comparison of single-crystal X-ray diffraction and thermogravimetric analysis results. The qNMR method for water content measurement is straightforward, reproducible, and accurate, including measurement of H-1 NMR spectrum before and after the addition of the analyte compound, and the result can be calculated after integration of the reference compound, analyte, and HDO signals using the given equation. In practical terms, there is no need for weighing the samples under study, which makes it simple and is a clear advantage to the current determination methods. In addition, the crystal structures of two model bisphosphonates used herein are reported: that of monopotassium etidronate dihydrate and monosodium zoledronate trihydrate.
- 3 November 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (46) , 17020-17027
Open AccessSimple and User-Friendly Methodology for Crystal Water Determination by Quantitative Proton NMR Spectroscopy in Deuterium Oxide
In drug research and development, knowledge of the precise structure of an active ingredient is crucial. However, it is equally important to know the water content of the drug molecule, particularly the number of crystal waters present in its structure. Such knowledge ensures the avoidance of drug dosage and formulation errors since the number of water molecules affects the physicochemical and pharmaceutical properties of the molecule. Several methods have been used for crystal water measurements of organic compounds, of which thermogravimetry and crystallography may be the most common ones. To the best of our knowledge, solution-state NMR spectroscopy has not been used for crystal water determination in deuterium oxide. Quantitative NMR (qNMR) method will be presented in the paper with a comparison of single-crystal X-ray diffraction and thermogravimetric analysis results. The qNMR method for water content measurement is straightforward, reproducible, and accurate, including measurement of H-1 NMR spectrum before and after the addition of the analyte compound, and the result can be calculated after integration of the reference compound, analyte, and HDO signals using the given equation. In practical terms, there is no need for weighing the samples under study, which makes it simple and is a clear advantage to the current determination methods. In addition, the crystal structures of two model bisphosphonates used herein are reported: that of monopotassium etidronate dihydrate and monosodium zoledronate trihydrate.
- Open Access
- 16 August 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (34) , 11739-11744
Real-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
Strict regulations are in place to control the effluents of mining sites and other industries. Heavy metal contamination of aquatic systems caused by leakages is difficult to mitigate as it takes time to detect and localize the leak. Dynamic sampling would drastically reduce the time to locate leakages and allow faster actions to reduce the impact on the environment. The present study introduces a novel portable multielement water analysis system to simultaneously measure Mn, Ni, Cu, Zn, Pb, and U in water samples from natural sources within 15 min from the sampling. The metals are preconcentrated from a 10 mL water sample into a nanoporous filter based on bisphosphonate-modified thermally carbonized porous silicon. The metals can be conveniently analyzed from the filter with a portable XRF analyzer in field conditions. The system was empirically calibrated for a lake water matrix with neutral pH and low alkaline metal concentration. A strong correlation between the XRF intensities and the ICP-MS results was obtained in a concentration range from 50 to 10 000 μg/L. With a DPO-2000C XRF analyzer, the detection limits were 103, 86, 92, 35, 44, and 43 μg/L for Mn, Ni, Cu, Zn, Pb, and U, respectively. The corresponding values with X-MET8000 Expert Geo were 137, 46, 62, 38, 29, and 54. The system was successfully validated with simulated multielement lake water samples and piloted in field conditions. The system provides an efficient way to monitor metals in environmental waters in cases where quick on-site results are needed.
- 16 August 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (34) , 11739-11744
Open AccessReal-Time On-Site Multielement Analysis of Environmental Waters with a Portable X-ray Fluorescence (pXRF) System
Strict regulations are in place to control the effluents of mining sites and other industries. Heavy metal contamination of aquatic systems caused by leakages is difficult to mitigate as it takes time to detect and localize the leak. Dynamic sampling would drastically reduce the time to locate leakages and allow faster actions to reduce the impact on the environment. The present study introduces a novel portable multielement water analysis system to simultaneously measure Mn, Ni, Cu, Zn, Pb, and U in water samples from natural sources within 15 min from the sampling. The metals are preconcentrated from a 10 mL water sample into a nanoporous filter based on bisphosphonate-modified thermally carbonized porous silicon. The metals can be conveniently analyzed from the filter with a portable XRF analyzer in field conditions. The system was empirically calibrated for a lake water matrix with neutral pH and low alkaline metal concentration. A strong correlation between the XRF intensities and the ICP-MS results was obtained in a concentration range from 50 to 10 000 μg/L. With a DPO-2000C XRF analyzer, the detection limits were 103, 86, 92, 35, 44, and 43 μg/L for Mn, Ni, Cu, Zn, Pb, and U, respectively. The corresponding values with X-MET8000 Expert Geo were 137, 46, 62, 38, 29, and 54. The system was successfully validated with simulated multielement lake water samples and piloted in field conditions. The system provides an efficient way to monitor metals in environmental waters in cases where quick on-site results are needed.