SDSvyatoslav O. Doroganov

Svyatoslav O. Doroganov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Svyatoslav O. Doroganov has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Our experience in developing an all-ceramic first carpal-metacarpal joint endoprosthesis

    by Котельников Геннадий Петрович, Gennadiy P. Kotelnikov, Andrey N. Nikolaenko, Николаенко Андрей Николаевич, Svyatoslav O. Doroganov, Дороганов Святослав Олегович, Alexander Р. Borisov, Борисов Александр Павлович

    Introduction. Risarthrosis is one of the common causes of disability in patients. Traditional interventions - trapezectomy and arthrodesis - have a number of serious complications. Therefore, the development of alternative surgical methods is relevant, including the arthroplasty of the first carpal-metacarpal joint (CMC-1). The aim of the work was to develop and experimentally substantiate an individual two-component unrelated whole-ceramic endoprosthesis of the CMC-1 for the surgical treatment of risarthrosis. Methods. For this study, cadaveric material was used: 5 male and 7 female hands, a total of 12 operations were performed. At the Research Institute of Bionics and Personalized Medicine, SamSMU designed and developed a two-component all-ceramic CMC-1 endoprosthesis, as well as special tools for installing implant components. Results. Based on computed tomography data, the design of an individual endoprosthesis was simulated. Further, computer modeling was carried out to create an individual virtual model of the implant. The distal and proximal components of the zirconium ceramic implant were manufactured by machining on numerically controlled machines. The proximal component was positioned on the articular surface of the trapezius bone, the distal component was mounted with an impactor and soft hammering. After installing the components of the endoprosthesis, load tests were CMC-1 performed, while the failure of the implant design due to its proximal component was revealed. Discussion. Currently, none of the surgical treatments for risarthrosis have clear benefits. To continue research for the development of an endoprosthesis, it is necessary to rethink the geometry of the implant leg, introduce additional anchor fixation, test various coatings to increase the coefficient of friction and osteointegration. Conclusion. An individual two-component unbound whole-ceramic design of the CMC-1 endoprosthesis for the surgical treatment of risarthrosis was experimentally substantiated. Despite the successful completion of the design and manufacturing stages, the design turned out to be mechanically untenable due to the ineffective fixation of the proximal component. significant experience was gained in the course of work, which can be used to develop new design options.

  • Testing of friction node simulators for hip prostheses

    by G.P. Kotelnikov, A.N. Nikolaenko, V.V. Ivanov, S.O. Doroganov, I.M. Mikailov, A.P. Borisov

    Objective. To estimate advisability of prototypes of ultra-high molecular weight polyethylene (UHMWPE) in hip arthroplasty. Material and methods. We used 34 UHMWPE specimens for tests and developed a test program consisting of incoming control of specimen geometrical parameters, tribotechnical tests, assessment of liner surface condition and deviation from roundness. Results. Input control of geometrical parameters of specimens showed their heterogeneity. UHMWPE specimens with negative value (Dc—Dh) failed tribotechnical tests. Specimens with value (Dc—Dh) within 0.6—0.8 mm demonstrated lower value of T moment compared to other specimens. Conclusion. About 75% of UHMWPE prototype liners are suitable for arthroplasty.

  • Open Access

    Our experience in the use of revascularized flaps in the surgical treatment of patients with soft tissue sarcomas

    by V. V. Ivanov, O. I. Kaganov, A. E. Orlov, A. N. Nikolaenko, S. O. Doroganov, I. V. Bondarenko

    Introduction. Soft tissue sarcomas (STS) are quite rare malignant tumors of mesenchymal origin. The incidence is up to 2% among all malignant neoplasms. In Russia, about 10,000 new cases of STS are registered annually. For a long time, the main treatment method for patients with soft tissue sarcomas of the extremities was amputation, which led to a decrease in quality of life and disability. Currently, thanks to a multidisciplinary approach, it has been possible to develop optimal tactics in the complex treatment of patients with this pathology. The modern view on the treatment of this group of patients involves drug therapy and adequate excision of the tumor, observing the ablastic principles. A necessary condition is that the distance from the palpable edge of the tumor should be 5-8 cm. Due to this indentation, the question arises of closing extensive post-resection soft tissue defects. This aspect creates certain difficulties in the treatment of patients with tumor localization, mainly in the distal parts, such as the hand and especially the foot. The purpose of this work is to analyze the experience of using revascularized flaps in the surgical treatment of patients with soft tissue sarcomas. The study was conducted at the Center of Oncology-Orthopedics of the Samara Regional Clinical Oncology Center.Object and methods. From 2020 to 2023, our observation included a group of patients of 10 people, 6 women and 4 men, ages from 29 to 64 years. Nosological types were: spindle cell sarcoma, liposarcoma, fibrosarcoma (pT1.2a-bN0M0, GI-III, IAB, IIA-B, stage III). All patients underwent surgical interventions, which included radical removal of the soft tissue tumor and the reconstructive stage of replacing the post-resection defect using revascularized flaps on microvascular anastomoses.Results. The main advantage of the reconstructive stage using microsurgical technology is the rapid restoration of the skin, replenishment of soft tissue deficits, including thickness, the strength of the flap to perform the supporting function, the absence of trophic disorders, the absence of joint contracture, restoration of limb function in the shortest possible time. The follow-up period was 3 years. During this time, the following were noted: relapse – 0, thrombosis of the microvascular anastomosis – 0, marginal necrosis of the flap – 1, joint contracture – 0. The relative disadvantages of using this technique include: the duration of the surgical intervention, the need for simultaneous work of several surgical teams, the constant improvement of the surgeon's manual and practical technique, the labor intensity of such operations and the mandatory availability of special optical equipment and suture material.Conclusion. The use of revascularized flaps in the surgical treatment of patients with soft tissue sarcomas makes it possible to radically remove the tumor and fully replace the post-resection defect, which in turn reduces the risk of relapses and promotes restoration of limb function with a good cosmetic result.

  • Open Access

    Evolution of the first metatarsophalangeal joint replacement

    by Г. П. Котельников, A. N. Nikolaenko, I. O. Grankin, V. V. Ivanov, P. Yu. Isaykin, S. O. Doroganov, D. O. Zgirsky, П. Ю. Исайкин

    Introduction The diseases of the first metatarsophalangeal (1 MTP) joint that require surgical treatment include osteoarthritis (69 %), rheumatoid arthritis (26 %), tumors, tumor-like diseases and purulent arthritis (5 %). The treatment of arthritic 1 MTP is aimed at reducing pain and improving function. Joint replacement implants are meant to support body weight, maintain the length of the first metatarsal, provide metatarsal‑sesamoid joint functioning and restore joint motion. The purpose of the work was to analyze data from foreign and domestic literature on endoprosthetics of the 1 MTP, and briefly present analytical data on the results of using various implants.Material and methods The article presents the summary of the Russian and foreign publications on 1 MTP joint replacement. The original literature search was conducted on key resources including PubMed, eLIBRARY, MedLine, Scopus. The search strategy was comprised of keywords: “replacement of the first metatarsophalangeal joint”, “surgical treatment of hallux rigidus”, “osteoarthrosis of the first metatarsophalangeal joint”, “results of endoprosthetics of the 1st metatarsophalangeal joint”, "modernization of implants of the 1st metatarsophalangeal joint". Publications brought out between 1968 and 2022 inclusive were analyzed.Results and discussion The ideal implant should restore functional range of motion, improve function, maintain joint stability, distribute the stress across joint surfaces being wear-resistant. Over the years, various materials have been used to provide simple and reliable designs. Implants have been improved and divided into groups based on material and design, limited degrees of freedom, tribological pair composition, and the amount of articular surface replacement.Conclusion New generation implants have a more durable design, anatomical shape and improved osseointegration. The advances in joint replacement have resulted in greater patient satisfaction and increased service life. The complication rate for replacement of the 1 MTP joint remains high. This indicates the need for continued research and further work to improve implants to make them more effective and easier to use.


  • Ankle replacement for severe post-traumatic deformation of the distal tibia: a case report

    by G.P. Kotelnikov, A.V. Kolsanov, A.N. Nikolaenko, V.V. Ivanov, D.A. Dolgushkin, A.S. Pankratov, D.O. Ogurtsov, S.O. Doroganov, A.D. Stroikova

    Objective. To evaluate the immediate results of ankle replacement with original prosthesis in a patient with severe post-traumatic deformation of the distal tibia. Material and methods. When developing the original design of ankle prosthesis, we considered foreign analogues of classical and revision models of ankle prostheses taking into account their shortcomings. In this case, an integrated approach was used. Extensive work has been carried out to select materials for prosthetic components. Experimental work with mesenchymal stromal cells of bone marrow was aimed at testing cytotoxicity and biological compatibility. The staff of the department of designing biomechanical structures of the Research Institute of Bionics and Personalized Medicine of the Samara State Medical University carefully studied the proposed design of endoprosthesis using the Ansys software. After cadaver tests on full-scale models, we performed surgical intervention in a patient with severe post-traumatic deformity of the lower third of the left tibia. Results. Our studies revealed convenience and certain advantages of intraoperative installation of original ankle prosthesis. Along with this, this clinical example indicated come features that must be taken into account in revision ankle replacement to avoid possible postoperative consequences. Conclusion. Original ankle prosthesis makes it possible to replace the distal tibia and preserve limb function.


  • Open Access

    Biomechanics of the proximal interphalangeal joint after total joint replacement

    by Г. П. Котельников, A. V. Kolsanov, A. N. Nikolaenko, D. O. Zgirskii, S. O. Doroganov

    Introduction Small joints arthroplasty of the hand including the proximal interphalangeal joint (PIPJ) is associated with the need to create anatomically adapted structures using optimal materials. Introduction of a new medical device requires comprehensive preclinical testing.The objective was to determine a range of loads allowed for the proximal interphalangeal joint after arthroplasty through analyzing the biomechanics to prevent critical conditions and complications.Methods A full-ceramic non-constrained anatomically adapted proximal interphalangeal joint implant was developed between 2016 and 2021 using an integrated approach with preclinical trials and a clinical study of 42 patients (25 males, 17 females) with PIPJ arthritis. A digital endoprosthesis was created with 3D-modelling. Critical conditions for the digital model imitating typical joint movements were explored with the use of finite element method and the findings to be employed in clinical practice.Results A stable biomechanical construct was intact with loads of 5 kilograms and a motion ranging from 0 to 60 degrees, with loads of 20 kilograms and a motion ranging between 0 and 30 degrees. Cortical bone could sustain loads up to 20 kilograms with a motion ranging between 0 and 60 degrees. Discussion Load capacity of the implant was explored considering the strength of bone tissue and zirconium ceramics as a material. The study set a vector for the development of the optimal mode of motor activity early after surgery and indicated the optimal range of motion to be applied after PIPJ arthroplasty.Conclusion The load up to 5 kg was optimal for the patient to be applied early after surgery with the range of flexion measuring less that 90°. The patient could use a load of 5 to 20 kg with flexion in the proximal interphalangeal joint measuring less than 30°. Endoprosthetic components were likely to get dislocated with a load of 20 kg and flexion angle of greater than 30°. Periprosthetic fracture could occur with flexion angle of greater than 60°.


  • Biomechanics of the first metatarsophalangeal joint after replacement

    by A.V. Kolsanov, A.N. Nikolaenko, V.V. Ivanov, I.O. Grankin, P.YU. Isaikin, S.O. Doroganov, D.O. Zgirsky, G.P. Kotelnikov

    Objective. Analysis of biomechanics of the first metatarsophalangeal joint after arthroplasty, interaction between bones and two implants of the first metatarsophalangeal joint using skeletal model of the foot. Material and methods. We developed anatomically adapted all-ceramic non-coupled endoprosthesis of proximal interphalangeal joint between 2016 and 2021. To create a model of the foot, we used diagnostic computed tomography whose images were applied in 3D sculpting system and computer-aided design system for final geometric modeling of the joint. Results. In dorsal flexion of the first metatarsophalangeal joint under 45° with the presence of implant, cortical bone tissue can withstand a load of up to 40 kg. Cortical bone tissue with implant can withstand a load of up to 305 kg without dorsal flexion. Strength of implant elements made of zirconium ceramics significantly exceeds strength of bone tissue within implant-bone tissue connection. Conclusion. Postoperative axial load on the first metatarsophalangeal joint up to 35 kg with maximum dorsal flexion up to 45° is the most appropriate. Higher load and hyperextension over 45° may be followed by postoperative complications such as implant instability, dislocation and periprosthetic fracture.


  • Arthroplasty of the metacarpophalangeal joint (literature review)

    by G.P. Kotelnikov, A.N. Nikolaenko, V.V. Ivanov, S.O. Doroganov, D.O. Zgirsky, P.YU. Isaikin

    Introduction Diseases and injuries that affect the small joints of the hand, the metacarpophalangeal, in particular, lead to a limitated hand function and a reduced quality of life. The high functional demands of the hand impose strict restoration requirements and the development of the new and improvement of the existing surgical treatments of hand joints remains a serious challenge for the medical community. Arthroplasty of the metacarpophalangeal joint is widely used and can help restore function to hand. Despite the long history of arthroplasty procedures there is controversy concerning functional results. Objective Review foreign and Russian literature on metacarpophalangeal joint replacement and analyze the current state of the problem. Material and methods Foreign and Russian scientific publications on the treatment of metacarpophalangeal diseases and injuries were reviewed. Online searching for the articles published in Russian and English in the last five years was performed with the help of GoogleScholar, PubMed, eLIBRARY, PubMedCentral using the keywords "arthroplasty of the metacarpophalangeal joint", "osteoarthritis of the metacarpophalangeal joint", "finger joint replacement". Results and discussion Today, a wide range of total hip prosthesis designs, differing in geometric configurations and features is available with the current trend towards adaptation of the soft tissues to the structural modifications. Major indications for the use of different types of arthroplasty have been identified. Specific design features of implants can show higher failure rates and postoperative complications. Conclusion Arthroplasty is the best surgical treatment option for diseases and injuries of the metacarpophalangeal joint and improved construction solutions and materials for metacarpophalangeal arthroplasty are essential for better outcomes.